Loading...
09-424-018w Q U 5 LLJ w ¢Mcn N U L� w Z 8 Z ~ o Z z ow�LV13 QJ W z O � CD N a. ow¢� W J N LLJ =5 W S � oo� a.: z°"'-r W O J N V)F--- �LwiL� QE O U O O0 �O La U Z z w C7 Z w � U N (D Z W off �N —pQ- ()Qviww = w w CD MmZ Q N���Cr W ry W J LLJ I n _ O¢Oa - cn Q 1 OR 2 -HOUR FIRE RATED GYPSUM WALLBOARD /STUD ASSEMBLY. ® STEEL SLEEVE. SCH 40(OR HEAVIER) STEEL PIPE WITH LENGTH AS SAME AS FLOOR /WALL THICKNESS PLUS 1 TO 4 IN. ® A) STEEL PIPE - 6" DIA. (OR SMALLER) SCH. 40 (OR HEAVIER) STEEL B) CONDUIT - 4" DIAM. (OR SMALLER) EMT OR RIGID STEEL. ® COMPLETELY FILL ANNULAR SPACE AND THICKNESS OF FLOOR OR WALL WITH FYRE- SHIELD. FILL MATERIAL SHALL BE DOMED ON BOTH SIDES OF ASSEMBLY TO A 1/2" HEIGHT IN ADDITION TO THICKNESS REQUIRED FOR OPENING. UL -1479 SINGLE METAL PIPE THRU ONE, TWO HOUR GYPSUM WALLBOARD /STUD ASSEMBLY RATED WALL N.T.S DETAIL Q FLOOR OR WALL ASSEMBLY = 2.5" THICK CONCRETE ® STEEL SLEEVE. SCH 40( OR HEAVIER) STEEL PIPE WITH LENGTH AS SAME AS FLOOR /WALL THICKNESS PLUS 1 TO 4 IN. Q • STEEL PIPE : MAX. 6" STEEL. • EMT: MAX. 4" ELECTRICAL METALLIC TUBING. ® COMPLETELY FILL ANNULAR SPACE AND THICKNESS AS FLOOR OR WALL WITH FYRE- SHIELD. FILL MATERIAL SHALL BE DOMED ON BOTH SIDES OF ASSEMBLY TO A 1/2" HEIGHT IN ADDITION TO THICKNESS REQUIRED FOR OPENING. UL -1479 SINGLE METAL PIPE THRU ONE AND TWO HOUR CONCRETE RATED WALL N.T.S DETAIL II GENERAL NOTES 1- INSTALLATION SHALL BE DONE IN STRICT ACCORDANCE WITH THE FLORIDA BUILDING CODE 2007 AND NEC 2005. 2- ALL CONDUCTORS SHALL BE COPPER, THWN TYPE RATED AT 75-C. 3- ALL CONDUITS SHALL BE E.M.T. UNLESS INDICATED OTHERWISE. 4- ALL RECEPTACLES SHALL HAVE AN ENGRAVED BRANCH CIRCUIT IDENTIFICATION PLATE INDICATING PANEL AND CIRCUIT NUMBER. 5- PROVIDE TYPED CIRCUIT INDEX FOR ALL NEW AND EXISTING PANELBOARDS. 6- PROVIDE ALL REQUIRED PERMITS AND PAY ALL FEES. 7- ALL BOXES SHALL BE METALLIC. 8- ALL RECEPTACLES SHALL BE 18" A.F.F. UNLESS INDICATED OTHERWISE. 9- PROVIDE A GREEN GIRD. WIRE TO ALL RECEPTACLES, AND FIXED EQUIPMENT. 10- CONTRACTOR MUST VISIT SITE TO BECOME FAMILIAR WITH EXISTING CONDITIONS BEFORE BIDDING THIS JOB. 11- CONTRACTOR SHALL INSTALL ALL ELECTRICAL EQUIPMENT FURNISHED BY THE OWNER OR OTHER CONTRACTOR. 12- ALL CONDUITS SHALL RUN CONCEALED U.I.O. 13- PROVIDE COVER PLATES FOR ALL OUTLETS. 14- ALL CONDUIT PENETRATIONS OF FIRE -RATED WALLS, FLOORS, AND CEILINGS SHALL BE SEALED IN ACCORDANCE WITH REQUIREMENTS OF NEC ARTICLE 300 -21 AND DETAILS I AND II ON THIS SHEET. 15- PROVIDE ALL THE REQUIRED WIRING AND CONDUIT. 16- CONTRACTOR SHALL PROVIDE SHOP DRAWINGS OF THE FOLLOWING FOR ENGINEER APPROVAL. A) LIGHTING FIXTURES, INCLUDING LAMPS. B) ALL ELECTRICAL COMPONENTS SWITCHES, RECEPTACLES, CONDUITS, PANELBOARDS, TRANSFORMERS CIRCUIT BREAKERS /FUSES, ETC C) NEW FIRE ALARM COMPONENTS (CUT SHEETS AND WIRING DIAGRAM) 17- ALL ELECTRICAL SWITCHES SHALL BE 48" A.F.F. UNLESS INDICATED OTHERWISE. 18- ALL LIGHT SWITCHES SHALL HAVE AN ENGRAVED BRANCH CIRCUIT IDENTIFICATION PLATE INDICATING PANEL AND CIRCUIT NUMBER. 19- COORDINATE MOUNTING HEIGHT OF ALL LIGHTING FIXTURES WITH ARCHITECT. 20- SHEETS WITH NOTES IN HEXAGON ARE FOR SPECIFIC LOCATIONS. NOTES WITHOUT HEXAGON ARE GENERAL NOTES FOR THAT SHEET. 21- ALL FLUORESCENT FIXTURES SHALL USE ENERGY CONSERVATION BALLAST AND LAMPS LAMPS (GE OR SYLVANIA) 22- FOR ALL DISCONNECTS PROVIDE NEMA 1 ENCLOSURE INDOORS AND NEMA 3R ENCLOSURE OUTDOOR. 23- ALL CONDUITS RUNNING UNDERGROUND BE PVC SCHEDULE 40 1" MINIMUM. 24- ALL CONDUITS RUNNING EXPOSED IN EXTERIOR AREAS UP TO 8' -0" HIGH TO BE RIGID METALLIC CONDUIT. 25- ALL CONDUITS RUNNING CONCELEAD TO BE EMT TYPE. 26- ALL ELECTRICAL COMPONENTS INCLUDING CONDUCTORS, BOXES AND EQUIF­ NTS LOCATED IN WET AND DAMP LOCATIONS EXPOSED TO GASES, FUMES, VAPORS, LIQUIDS OR OTHE' DETERIORATING AGENTS SHALL BE APPROVED FOR THAT PURPOSE. w ABBREVIATIONS A.F.F. ABOVE FINISHED FLOOR BKR. BREAKER A.I.C. AMPERE INTERRUPTING CAPACITY C.B. CIRCUIT BREAKER C. CONDUIT CKT. CIRCUIT CLG. CEILING CL. CLOSET COM. COMMUNICATION C.T. CURRENT TRANSFORMER DR. DOOR EL/ELECT. ELECTRIC /ELECTRICAL E.FF. EXHAUST FAN E.C. EMPTY CONDUIT EL. CL. ELECTRICAL CLOSET EM. EMERGENCY EMT ELECTRICAL METALLIC CONDUIT EQ EQUIPMENT E.W.C. ELECTRIC WATER COOLER EX EXISTING EXP EXPLOSION GEN. GENERATOR FBC FLORIDA BUILDING CODE FLUOR. FLUORESCENT GND. GROUND G.F.I. GROUND FAULT INTERRUPTER G.T.B. GROUND TERMINAL BOX HT. HEIGHT H.P. HORSE POWER HTR. HEATER J.B. JUNCTION BOX K.V.A. KILOVOLT AMPERES K.V. KILOVOLT K.W. KILOWATT MAX. MAXIMUM MIN. MINIMUM M.C.B. MAIN CIRCUIT BREAKER MFR. MANUFACTURER MOD. MODEL MTD. MOUNTED NEC NATIONAL ELECTRICAL CODE LTG. LIGHTING WPO• UNLESS INDICATED OTHERWISE WEATHERPROOF OR NEMA 3R UL UNDERWRITERS LABORATORIES NOTE: ALL ABBREVIATIONS SHOWN ARE NOT NECESSARILY USED FOR THIS PROJECT. LIST OF DRAWINGS E -1 SYMBOL LEGEND SCHEDULES & ABBREVIATIONS. E -2 NEW LIGHTING PLAN. E -3 NEW POWER PLAN. E -4 PARTIAL POWER RISER DIAGRAM AND PANEL SCHEDULES. SYMBOL LEGEND SYMBOL I DESCRIPTION I FLUORESCENT LIGHTING FIXTURE CEILING MTD IN NORMAL POWER. TYPE AS SPECIFIED. ® FLUORESCENT DOWNLIGHT CEILING MTD. TYPE AS SPECIFIED. CEILING /WALL MTD. EXIT LIGHT. CEILING /WALL MTD. COMBINAYION EMERGENCY /EXIT LIGHT. CEILING /WALL MTD. EMERGENCY LIGHT. DATA /TELEPHONE OUTLET MTD 18" AFF.,U.1.0 a TELEPHONE OUTLET MTD. 18" A.F.F.,U.1.0 F14-1 DATA /TELEPHONE OUTLET FLOOR MTD Sn FIRE ALARM SYSTEM PHOTOELECTRIC SMOKE DETECTOR ADDRESSABLE TYPE. 6D FIRE ALARM SYSTEM DUCT SMOKE DETECTOR ADDRESSABLE TYPE FIRE ALARM SYSTEM HEAT DETECTOR. FIRE ALARM "SYSTEM COMBINATION HORN /STROBE LIGHT (75 Cd) 04 MTD. AT 80 MEASURED FROM FINISHED FLOOR TO BOTTON OF DEVICE. 20A, 125V, 3 WIRE GROUND FAULT INTERRUPTER DUPLEX RECEPTACLE, 6" ABOVE COUNTERS OR 42" A.F.F., U.I.O. FO 20A, 125V, 3 WIRE GROUNDING TYPE SPECIFICATION GRADE DUPLEX RECEPTACLE, FLOOR MTD. CONDUIT RUN CONCEALED UNLESS INDICATED OTHERWISE - — — — - UNDERGROUND CONDUIT, 2' -0" MINIMUM BELOW GRADE CONDUIT TURNED UP CONDUIT TURN DOWN HOME RUN PANEL LPI, CIRCUIT # 3, TICK MARKS DENOTE NUMBER OF WIRES: (U.I.O. # 12 IN 3/4" C). LONG MARKS NEUTRAL, SHORT MARKS LP1 -3 HOT OR SWITCH LEGS, DOT MARKS GREEN GROUND WIRE. 0 MOTOR, NUMBER IN CIRCLE DENOTES HORSE POWER RATING Q /40 CEILING OR WALL MTD. JUNCTION BOX PB PULL BOX, SIZE AS PER NEC SURFACE WALL MTD. PANELBOARD FLUSH MTD. PANELBOARD 3-3-0- 1�� SAFETY DISCONNECT SWITCH, 30= SWITCH SIZE, 3 =No. OF POLES, 150-1 �� 15 =FUSE SIZE, O =NON FUSED C.R. CARD READER r___1 DOOR CHIME D.B. DOOR BELL Da CEILING / WALL MOUNTED VIDEO CAMERA (EMPTY CONDUIT SYSTEM, EQUIPMENT BY OWNER) NOTE: 1. ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED FOR THIS PROJECT. 2. ALL FIRE ALARM SYSTEM COMPONENTS MUST BE ADDRESSABLE AND MEET ADA REQUIREMENTS. 151 SEVILLAAVENLIE,- tiLJiTE20a- - - CORAL GABLES, FL 33134 OFFICE: (305) 442 -1188 FAX: (305) 445 -1509 WWW. ADCINTERNATIONAL.NET bw STATE OF FLORIDA AR- 0010536 RAYMUNDO FEITO, R.A. AA— CO01315 Architect • Seal/Signature MRA EXI"ANSION SUNSET PROFESSIONAL BLDG 6280 SUNSET DR SUITE 600 SOUTH MIAMI FL Key Plan - Scope of Work Area Z KPV PI AN I FCaFNn AREA AT WHICH / i THE SCOPE OF WORK WILL BE 'T' PERFORMED. N.I.C. AREA CONSTRUCTION NOTE FAFINSEDSFLOR O TF EE TD. AT 80" MEASURED ROMFI ODVIC FINISHED OTBOTON Q FIRE ALARM SYSTEM CEILING MOUNTED SPEAKER. F.A.C.P FIRE ALARM SYSTEM CONTROL PANEL $M MOTOR RATED SWITCH I 20A, 120/277VAC SINGLE POLE TOGGLE SWITCH, SPECIFICATION GRADE THE WORK. THE GENERAL AND 4'-0 „ A.F.F. $3 THREE WAY SWITCH, SAME AS ABOVE i 20A, 125V, 3 WIRE GROUNDING TYPE SPECIFICATION GRADE DUPLEX ARE NOT RESTRICTED TO THOSE RECEPTACLE, MTD. 18” A.F.F., U.I.O. ' Date $ Issue Description Drawn By Checked By 20 A. 125V. 3 WIRES GROUND TYPE SPECIFICATION GRADE QUADRUPLEX RECEPT. MTD. 18" A.F.F., U.I.O. 20A, 125V, 3 WIRE GROUND FAULT INTERRUPTER DUPLEX RECEPTACLE, 6" ABOVE COUNTERS OR 42" A.F.F., U.I.O. FO 20A, 125V, 3 WIRE GROUNDING TYPE SPECIFICATION GRADE DUPLEX RECEPTACLE, FLOOR MTD. CONDUIT RUN CONCEALED UNLESS INDICATED OTHERWISE - — — — - UNDERGROUND CONDUIT, 2' -0" MINIMUM BELOW GRADE CONDUIT TURNED UP CONDUIT TURN DOWN HOME RUN PANEL LPI, CIRCUIT # 3, TICK MARKS DENOTE NUMBER OF WIRES: (U.I.O. # 12 IN 3/4" C). LONG MARKS NEUTRAL, SHORT MARKS LP1 -3 HOT OR SWITCH LEGS, DOT MARKS GREEN GROUND WIRE. 0 MOTOR, NUMBER IN CIRCLE DENOTES HORSE POWER RATING Q /40 CEILING OR WALL MTD. JUNCTION BOX PB PULL BOX, SIZE AS PER NEC SURFACE WALL MTD. PANELBOARD FLUSH MTD. PANELBOARD 3-3-0- 1�� SAFETY DISCONNECT SWITCH, 30= SWITCH SIZE, 3 =No. OF POLES, 150-1 �� 15 =FUSE SIZE, O =NON FUSED C.R. CARD READER r___1 DOOR CHIME D.B. DOOR BELL Da CEILING / WALL MOUNTED VIDEO CAMERA (EMPTY CONDUIT SYSTEM, EQUIPMENT BY OWNER) NOTE: 1. ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED FOR THIS PROJECT. 2. ALL FIRE ALARM SYSTEM COMPONENTS MUST BE ADDRESSABLE AND MEET ADA REQUIREMENTS. 151 SEVILLAAVENLIE,- tiLJiTE20a- - - CORAL GABLES, FL 33134 OFFICE: (305) 442 -1188 FAX: (305) 445 -1509 WWW. ADCINTERNATIONAL.NET bw STATE OF FLORIDA AR- 0010536 RAYMUNDO FEITO, R.A. AA— CO01315 Architect • Seal/Signature MRA EXI"ANSION SUNSET PROFESSIONAL BLDG 6280 SUNSET DR SUITE 600 SOUTH MIAMI FL Key Plan - Scope of Work Area Z KPV PI AN I FCaFNn AREA AT WHICH / i THE SCOPE OF WORK WILL BE 'T' PERFORMED. N.I.C. AREA CONSTRUCTION NOTE WConsultant a Seal/Signature z ENGINEERING DEiSI ' a, GR. CORP. J ' 0 U 21 SW 102 Ct. Mia 174 Office: (786) 863- Fax: (305) 220 -51 pgengineerdesign ®bellsouth.net U w E=1 m0 .J WSTATE OF FLORIDA LUIS O. PEREZ, PE P.E. No. 62586 THE CONTRACTOR, BY VIRTUE OF SIGNING THE CONTRACT, ACKNOWLEDGES THAT HEAND I ALL HIS SUBCONTRACTORS HAVE SATISFIED THEMSELVES AS TO I THE NATURE AND LOCATION OF I THE WORK. THE GENERAL AND LOCAL CONDITIONS INCLUDE, BUT i ARE NOT RESTRICTED TO THOSE ' Date $ Issue Description Drawn By Checked By BEARING UPON; ACCESS POINTS AND POINTS OF CONNECTION TO THE SITE; THE CONFORMATION AND CONDITIONS OF THE WORK AREA; AND THE CHARACTER OF EQUIPMENT AND DEVICES NEEDED PRELIMINARY TO AND DURING THE PERFORMANCE OF THE WORK. i FAILURE ON THE PART OF THE I `� CONTRACTOR TO COMPLETELYOR .` PROPERLY EVALUATE ANY FACTORS OF COSTS PRIOR TO BIDDING SHALL NOT FORMA BASIS FOR ADDITIONAL COMPENSATION IF HE IS AWARDED THE CONTRACT. IADate S Issue Description Drawn By Checked By WConsultant a Seal/Signature z ENGINEERING DEiSI ' a, GR. CORP. J ' 0 U 21 SW 102 Ct. Mia 174 Office: (786) 863- Fax: (305) 220 -51 pgengineerdesign ®bellsouth.net U w E=1 m0 .J WSTATE OF FLORIDA LUIS O. PEREZ, PE P.E. No. 62586 I I I i ' Date $ Issue Description Drawn By Checked By Project Number Client Name 09032 PROMI) PROPERTIES Description Client Address ELECTRICAL PLAN 16% NE MIAMI GARDENS DR SUITE 8 Scale N. MIAMI BEACH, FL 33119 AS SHOWN Client Phone Number (305) 941 -8800 CAD File Name C:V2 Projects 112200SItADCI /2MRA EXPANSION WConsultant a Seal/Signature z ENGINEERING DEiSI ' a, GR. CORP. J ' 0 U 21 SW 102 Ct. Mia 174 Office: (786) 863- Fax: (305) 220 -51 pgengineerdesign ®bellsouth.net U w E=1 m0 .J WSTATE OF FLORIDA LUIS O. PEREZ, PE P.E. No. 62586