Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
09-424-009
0 08 0 SUPPORT WIRE (REFER TO LINE 5 BELOW) LAY IN ACOUSTICAL CEILING TILE REFER TO FINISH SCHEDULE CEILING MAIN CROSS RUNNER REFER TO FINISH SCHEDULE ACOUSTICAL CEILINGS NON RATED) 1. SEE ARCHITECTURAL DRAWINGS FOR EXTENT OF WORK, DETAILS AND SPECIFICATIONS. 2. THE ACOUSTICAL CEILINGS SHALL BE INSTALLED COMPLETE WITH SUSPENDED EXPOSED 'T' GRID AND LAY -IN CEILING TILES. 3. INSTALL SUSPENSION SYSTEMS IN ACCORDANCE WITH MANUFACTURES PRINTED INSTRUCTIONS, AND TO COMPLY WITH ASTI C635, MEDIUM DUTY SYSTEM. 4. COORDINATE INSTALLATION WITH ELECTRICAL AND MECHANICAL WORK. 5. SUSPENSION SYSTEM: PROVIDE HUNG SUSPENSION SYSTEM. GRILLAGE SHALL CONSIST OF MAIN RUNNERS, CROSS RUNNERS AND STABILIZER BARS AS REQUIRED. HANGER WIRES SHALL BE NOT LESS THAN 12 GAUGE GALVANIZED SOFT ANNEALED MILD STEEL WIRE. WIRES SHALL BE WRAPPED AT LEAST (4) COMPLETE TURNS AROUND SUPPORTS. WIRE SPACING TO BE AX OF 48" O.C. ALONG MAIN RUNNERS (PROVIDE 12 GAUGE WIRE SUPPORTS SPLAYED IN FOUR DIRECTIONS FOR DIAGONAL BRACING. MAINTAIN AN ANGLE OF 45' ON STEEPER & 6" MIN. CLEAR TO ALL HORIZONTAL PIPING OR DUCTWORK. ONLY IN SCHEMATIC ZONES, 6. MOLDINGS: PROVIDE MANUFACTURES STANDARD 'L' SHAPED MOLDINGS TOP MATCH 'T' - MINIMUM LENGTH OF 18 ". 7. CONTRACTOR SHALL FIELD CHECK THE PREMISES AND VERIFY ALL CLEARANCES AS REQUIRED FOR ALL LIGHTING FIXTURES BEFORE PROCEEDING WITH ANY INSTALLATION REPORT ANY DISCREPANCIES TO THE ARCHITECT. 8. ALL FIXTURE TRIM (LIGHTING, SPEAKERS, HVAC, GRILLES, ETC.) SHALL BE METAL AND PAINTED TO MATCH ADJACENT FINISH. PLASTIC TRIM IS NOT ACCEPTABLE UNLESS APPROVED BY ARCHITECT. 9. LEVEL CEILING TO WITHIN 1/8" IN 12' -0" IN ANY DIRECTION. LEVEL WITH HANGER WIRE TAUGHT AND PLUMB, WITHOUT KINKING OR BENDING HANGER WIRES. CEILING HEIGHT SHALL MATCH EXISTING U.O.N. 10. PROVIDE 5% ATTIC STOCK OF ACOUSTICAL TILE MATERIAL USED. 11. SUBMIT ONE FULL SAMPLE OF ACOUSTICAL MATERIAL AND ONE OF EACH TYPE SUSPENSION MEMBER, MOLDING AND HANGER FOR REVIEW BY ARCHITECT. ON i:✓ V, try j :t: C.- _ .. U-5, r,. �.... :Y" _7 y EXIST. DRYWALL CEILING TO REMAIN. PROTECT AT ALL TIMES DURING CONSTRUCTION (FIELD VERIFY) NEW /EXIST. SUSPENDED ACCOUSTICAL -TILE CEILING SYSTEM (FIELD VERIFY) CEILING SECTION EXSTG GWB TO NEW ACT SCALE: NTS EXIST. DECK ABOVE I 3%" 25 GA STUDS ® 24" O.C. (TYP) FASTENED TO DECK F %" GWB FASTENED TO 3Y8" 25 GA MTL STUD CEILING SECTION- NEW GWB TO NEW ACT SCALE: N.T.S. REFLECTED CEILING PLAN LEGEND (REFER TO ENGINEERING) SINGLE POLE SWITCH (REFER TO ENGINEERING) 3 THREE WAY SWITCH (REFER TO ENGINEERING) DIMMER SWITCH (REFER TO ENGINEERING) NEW 24"x48" ARMSTRONG "FINE FISSURED" #1755 (WHITE) ACOUSTICAL LAY -IN TILE W/ 1516" GRID GYP BOARD CEILING COMMON CORRIDOR -A if 151 EVILLA AVENUE, SUITE 200 CORAL GABLES, FL 33134 OFFICE: (305) 442 -1188 FAX: (305) 445 -1509 VVWVV. ADCINTERNATIONAL.NET C' c, i 1` 1\ STATE OF FLORIDA AR- 0010536 RAYMUNDO FEITO, R.A. AA— CO01315 Architect • Seal/Signature ....................................................................................... ............................... MRA EXPANSION SUNSET PROFESSIONAL BLDG 6280 SUNSET DR SUITE 600 SOUTH MIAMI FL Date Issue Description Drawn By Checked By 3 -16 -09 TENANT REVIEW ER ER .................................................................................................................................................. ............................... 3 -23 -09 TENANT REVIEW ER ER _. ....___._..__._...__ ... _ ..... . 04 -13 -09 LANDLORD REVIEW ER ER 04 -27 -09 PERMIT ISSUE ER ER NLI— LLL I tU ULILIINV IJLAIN SCHEDULE OF LIGHTING EQUIPMENT \ / x DESCRIPTION MAKE / MODEL REMARKS LIGHTING FIXTURES </ x� `� �� EXIST. DECK ABOVE i \ l \ .� PATCH AND REPAIR EXSTG LYTECASTER 1102P1 SERIES ? '>% DRYWALL SOFFIT AS NECESSARY RECESSED DOWNLIGHTS W/ MATTE BLACK STEP BAFFLE REFLECTOR (1105) OO 4" FLUORESCENT MATCH EXISTING RECESSED DOWNLIGHTS '��; LIGHTOLIER (OR APPROVED EQUAL) r •� LYTECASTER 1102P1 SERIES EXIST. DRYWALL CEILING TO REMAIN. PROTECT AT ALL TIMES DURING CONSTRUCTION (FIELD VERIFY) NEW /EXIST. SUSPENDED ACCOUSTICAL -TILE CEILING SYSTEM (FIELD VERIFY) CEILING SECTION EXSTG GWB TO NEW ACT SCALE: NTS EXIST. DECK ABOVE I 3%" 25 GA STUDS ® 24" O.C. (TYP) FASTENED TO DECK F %" GWB FASTENED TO 3Y8" 25 GA MTL STUD CEILING SECTION- NEW GWB TO NEW ACT SCALE: N.T.S. REFLECTED CEILING PLAN LEGEND (REFER TO ENGINEERING) SINGLE POLE SWITCH (REFER TO ENGINEERING) 3 THREE WAY SWITCH (REFER TO ENGINEERING) DIMMER SWITCH (REFER TO ENGINEERING) NEW 24"x48" ARMSTRONG "FINE FISSURED" #1755 (WHITE) ACOUSTICAL LAY -IN TILE W/ 1516" GRID GYP BOARD CEILING COMMON CORRIDOR -A if 151 EVILLA AVENUE, SUITE 200 CORAL GABLES, FL 33134 OFFICE: (305) 442 -1188 FAX: (305) 445 -1509 VVWVV. ADCINTERNATIONAL.NET C' c, i 1` 1\ STATE OF FLORIDA AR- 0010536 RAYMUNDO FEITO, R.A. AA— CO01315 Architect • Seal/Signature ....................................................................................... ............................... MRA EXPANSION SUNSET PROFESSIONAL BLDG 6280 SUNSET DR SUITE 600 SOUTH MIAMI FL Date Issue Description Drawn By Checked By 3 -16 -09 TENANT REVIEW ER ER .................................................................................................................................................. ............................... 3 -23 -09 TENANT REVIEW ER ER _. ....___._..__._...__ ... _ ..... . 04 -13 -09 LANDLORD REVIEW ER ER 04 -27 -09 PERMIT ISSUE ER ER NLI— LLL I tU ULILIINV IJLAIN SCHEDULE OF LIGHTING EQUIPMENT ITEM DESCRIPTION MAKE / MODEL REMARKS LIGHTING FIXTURES LIGHTOLIER (OR APPROVED EQUAL) O 6" FLUORESCENT LYTECASTER 1102P1 SERIES RECESSED DOWNLIGHTS W/ MATTE BLACK STEP BAFFLE REFLECTOR (1105) OO 4" FLUORESCENT MATCH EXISTING RECESSED DOWNLIGHTS (WITH MATTE BLACK STEP BAFFLE REFLECTOR) LIGHTOLIER (OR APPROVED EQUAL) VP VAPOR PROOF SHOWER DOWNLIGHT LYTECASTER 1102P1 SERIES W/ LEXAN DIFFUSER (1177SH) 2 X 4 PRISMATIC RELOCATED FLUORESCENT FIXTURE WALL SCONCE PROGRESS LIGHTING SUPPLIED BY TENANT; INSTALLED BY GC HIDE -A -LIGHT XENON UNDERCABINET LIGHT #PG -P7034 SUPPLIED BY TENANT; INSTALLED BY GC WALL SCONCE RESTROOM WALL SCONE WALL LEGEND EEXISTING BUILDING COLUMN TO REMAIN. EXISTING WALL TO REMAIN, TYP. NEW CORRIDOR SMOKE PARTITION (FILL IN) NEW INTERIOR PARTITION TO 6" ABOVE GRID REFER TO SECTION 1, SHEET A5.0 PROJECT NOTES: 1O RELOCATED 2'X4' PRISMATIC FLUORESCENT FIXTURE, TYP. O NEW 2'X4' ACOUSTICAL CEILING TILE AND GRID SYSTEM. CONTRACTOR SHALL INSTALL ACOUSTICAL CEILING TILE AND GRID SYSTEM ACCORDING TO MANUFACTURERS RECOMMENDATIONS O3 NEW 6" FLOURESCENT DOWNLIGHTS W/ BAFFLE, TYP. (REFER TO LIGHTING LEGEND FOR SPECIFICATIONS) ® NEW 4" FLOURESCENT DOWNLIGHTS W/ BAFFEL TO MATCH EXISTING O5 NEW DRYWALL CEILING PAINTED P4 (REFER TO A3.0 FOR FINISH LEGEND) © GC TO INSTALL TENANT SUPPLIED WALL SCONCE IN ADA BATHROOM O7 NEW EXHAUST FAN (REFER TO ENGINEERING) ® NEW VAPOR PROOF SHOWER DOWNLIGHT (REFER TO ENGINEERING) O9 NEW BUILDING STANDARD EXIT SIGN (REFER TO ENGINEERING) 1� EXSTG CEILING TO REMAIN (NIC) 11 NEW DOWNLIGHTS IN OPEN AREA TO BE CONTROLLED BY NEW NURSE STATION (TYP) 1� NEW PRISMATIC LIGHT FIXTURES IN OPEN AREA TO BE CONTROLLED BY NEW NURSE STATION (TYP) 1� NEW GWB HEADER (PAINTED P4) TO BE FLUSH W/ ACOUSTICAL TILE (9' -0" AFF) 14 GC TO REMOVE ALL ABANDONED CONDUITS, CABLES, ETC IN PLENUM THROUGHOUT; CLEAN PLENUM OF ALL LOOSE DEBRIS Project Number 09032 Description Scale Y4" = 1' -0'. CAD File Name REFLECTED CEILING PLAN Consultant • Seal/Signature Client Name PROMED PROPERTIES Client Address 1696 NE MIAMI GARDENS DR SUITE 8 N. MIAMI BEACH, FL 33179 Client Phone Number (305) 947 -8800 CITY OF SOUTH f6 J -AAv;i BUILDING DEPT. BUILDING SECTION APPROVED BY• �^ x-05 &TE• ✓r-� A4.0 Pxolml-i