Loading...
09-424-005w� z.; C.) '•� ; f 3 a r ILI V z 3 COMMON CORRIDOR ('FII INC. F)FMnI ITInN CEILING DEMOLITION NOTES 1. CONTRACTOR IS RESPONSIBLE FOR THE DEMOLITION OF ALL PARTITIONS, CEILING GRID AND TILE, ELECTRICAL, LOW VOLTAGE WIRING, ETC. 2. LANDLORD TO PROVIDE ASBESTOS SURVEY FOR DERM APPROVAL. WALL LEGEND L DEMOLITION LEGEND EXISTING BUILDING COLUMN TO REMAIN. EXISTING WALL TO REMAIN, TYP. EXISTING INTERIOR PARTITION TO BE REMOVED EXISTING 24 "x48" GRID & CEILING TILE TO BE REMOVED & DISCARDED I I I F___---i I II II EXISTING 24 "x48" PRISMATIC LIGHT FIXTURE TO BE REMOVED & RELOCATED (REFER TO ENGINEERING) L = = =A lFv — 7 II �� II EXISTING 24 "x24" HVAC AIR SUPPLY GRILLE. GRILLE TO BE REMOVED & RELOCATED (REFER TO ENGINEERING) L—JI PROJECT NOTES: 10 EXISTING BUILDING STRUCTURE TO REMAIN (TYP) O2 EXISTING EXTERIOR GLASS CURTAIN WALL TO REMAIN, TYP. O3 EXISTING AREAS TO REMAIN (NIC) ® REMOVE EXISTING 24 "x48" CEILING GRID & TILES AND/ OR DRYWALL CEILING THROUGHOUT AND DISCARD O5 REMOVE & RELOCATE ALL EXISTING 24 "x48" PRISMATIC LIGHT FIXTURES WHERE INDICATED (REFER TO A4.0). GC TO CLEAN & REFURBISH AS NECESSARY © REMOVE & RELOCATE EXISTING SPRINKLER HEADS (REFER TO ENGINEERING) Q REMOVE EXISTING GWB CEILING & LIGHT FIXTURES WHERE INDICATED (REFER TO ENGINEERING). RETURN EXISTING LIGHT FIXTURE TO TENANT ® REMOVE & RELOCATE EXISTING T —STAT (REFER TO ENGINEERING) O9 REMOVE EXISTING FIRE ALARM DEVICE (REFER TO ENGINEERING) REMOVE EXISTING SPEAKER & DISCARD 11 REMOVE & RELOCATE ALL EXISTING 24 "x24" HVAC SUPPLY AND /OR RETURN AIR GRILLES (REFER TO ENGINEERING). GC TO CLEAN & REFURBISH AS NECESSARY 1� REMOVE & RELOCATE EXISTING EXIT SIGNS (REFER TO ENGINEERING). GC TO CLEAN & REFURBISH AS NECESSARY 1� REMOVE EXISTING LIGHT SWITCH AND/ OR LIGHT SWITCH BANK 14 GC TO REMOVE ALL ABANDONED CONDUITS, CABLES, ETC IN PLENUM THROUGHOUT; CLEAN PLENUM OF ALL LOOSE DEBRIS C L� 1 151- SEVILLA: ,VENUE, SUITE-26o CORAL GABLES, FL 33134 OFFICE: (305) 442 -1188 FAX: (305) 445 -1509 WWW. ADCINTERNATIONAL.NET t Elf() t t 1 STATE OF FLORIDA AR- 0010536 RAYMUNDO FEITO, R.A. AA- CO01315 Architect • Seal/Signature ..... ...................................................................... ............................... MRA EXPANSION SUNSET PROFESSIONAL BLDG 6280 SUNSET DR SUITE 600 SOUTH MIAMI FL Date Issue Description Drawn By Checked By 04 -13 -09 LANDLORD REVIEW ER ER ....................................................................................................................................................... ............................... 04 -27 -09 PERMIT ISSUE ER ER Date & Issue Description Drawn By Checked By ........................................................................................................................................... Project Number ............................... Client Name 09032 PROMED PROPERTIES Description Client Address 1696 NE MIAMI GARDENS DR SUITE 8 Scale N. MIAMI BEACH, FL 33179 X.' = 1 - -0" Client Phone Number (305) 947 -8800 CAD File Name CEILING DEMOLITION PLAN Consultant. Seal/Signature CiTBU OF SOUT�A LDING DEPT. X111 $ UILDING SECTION APPROVED 8Y 0 a1_oc, NAM � IF _ II "\ II EXISTING 24 "x24 "' HVAC AIR RETURN GRILLE. GRILLE TO BE REMOVED & RELOCATED (REFER TO ENGINEERING) L —A Al,, SPRINKLER HEAD TO BE REMOVED & RELOCATED (REFER TO ENGINEERING) 5 OF 15