Loading...
09-424-003<; �,, ( Y `A I.3 ... 3 .... ) CJ :.3 Kr y,-'� - , .- 4 ....> U) i ? Wr, :: a _. ai a ' j C:) i.r - . - ` C. ..3 . " , %1 __ _a w 3 ....a :..,., t:_ = i; . „, 'i p � ' iii L'_`. < ,. >- :'..:•:. r' .`, - -? .):., ; :..� :r ... . 1 :.:i.. ­1` :a ._ GENERAL NOTES & CONDITIONS SPECIFICATIONS FOR GENERAL CONTRACTORS PERFORMING WORK FOR PALMETTO BAY VILLAGE CENTER 1.1 UPON COMPLETION OF THE JOB, THE CONTRACTOR PROVIDE THE TENANT AND LANDLORD WITH: A. AS -BUILT PLANS. B. RELEASE OF LIENS FOR ALL SUB - CONTRACTORS. C. A FINAL RELEASE OF LIENS FROM THE GENERAL CONTRACTOR. D. THE ORIGINAL BUILDING PERMIT PLANS WITH THE ORIGINAL INSPECTOR'S SIGNATURES. 1.2 THE LANDLORD WILL NOT BE RESPONSIBLE FOR: A. SECURITY OF MATERIALS OF WORK IN PLACE. B. AIR CONDITIONING WORK NOT BEING PROPERLY PERFORMED TO ALLOW FOR PROPER COOLING OF THE LEASED PREMISES UNLESS ALL AIR CONDITIONING WORK IS DONE IN COORDINATION WITH THE BUILDING ENGINEERING STAFF. C. WARRANTY REPAIRS. D. WINDOW BREAKAGE DURING CONSTRUCTION. E. WORK STOPPAGES DUE TO WORK INTERFERING WITH OTHER TENANTS. F. DELAYS DUE TO CHANGE ORDERS AND ARCHITECT - CONTRACTOR PROBLEMS. G. PAYMENT OF ANY DRAW WILL BE SUBJECT TO THE LANDLORD'S AND OWNER'S REPRESENTATIVES AGREEING TO THE DEGREE OF COMPLETION, TEN PERCENT (10%) OF EACH DRAW WILL BE HELD AS A RETAINER UNTIL THE JOB IS COMPLETED, INCLUDING PUNCH LIST ITEMS, RELEASES OF LIEN, AND ACCEPTANCE OF THE SPACE BY BOTH THE TENANT AND LANDLORD. 1.3 THE CONTRACTOR WILL: SECURE THE NECESSARY BUILDING PERMITS AND INSPECTIONS. INDEMNIFY AND KEEP HARMLESS THE OWNER FROM ALL LOSSES, DAMAGES, LIABILITIES, AND EXPENSES WHICH MAY ARISE OR BE CLAIMED AGAINST LANDLORD AND BE IN FAVOR OF ANY PERSONS, FIRMS, OR CORPORATIONS FOR ANY INJURIES OR DAMAGES TO THE PERSON OR PROPERTY OF ANY PERSONS, FIRMS, OR CORPORATION CONSEQUENT UPON OR ARISING FROM THE CONSTRUCTION, USE, OR OCCUPANCY OF LEASED PREMISES BY THE CONTRACTOR OR CONSEQUENT UPON OR ARISING FROM ANY ACTS, OMISSIONS, NEGLECT OR FAULT OF THE CONTRACTOR , HIS AGENTS, SERVANTS, EMPLOYEES, LICENSEES, VISITORS, CUSTOMERS, PATRONS, OR INVITEES, OR CONSEQUENT UPON OR ARISING FROM THE CONTRACTOR'S FAILURE TO COMPLY WITH ANY LAWS, STATUTES, ORDINANCES, CODES, OR REGULATIONS; THAT THE OWNERS SHALL NOT BE LIABLE TO THE CONTRACTOR FOR DAMAGES, LOSSES OR INJURIES TO THE PERSONS, FIRMS OR CORPORATIONS EXCEPT WHEN SUCH INJURY, LOSS, OR DAMAGE RESULTS FROM NEGLIGENCE OF THE OWNER, HIS AGENTS, OR EMPLOYEES, AND THAT THE CONTRACTOR WILL IDEMNIFY AND KEEP HARMLESS THE OWNERS AND BE IN FAVOR OF ANY PERSONS, FIRMS, OR CORPORATIONS FOR ANY INJURIES OR DAMAGES TO THE PERSON, OR THE PROPERTY OF ANY PERSONS, FIRMS OR CORPORATIONS WHERE SAID INJURIES OR DAMAGES AROSE ABOUT OR UPON THE LEASED PREMISES AS A RESULT OF THE HE NEGLIGENCE OF THE CONTRACTOR, HIS AGENTS, EMPLOYEES,SERVANTS, LICENSEES, VISITORS, CUSTOMERS, PATRONS, AND INVITEES. ALL PERSONAL PROPERTY PLACED OR MOVED INTO OR OUT OF THE BUILDING SHALL BE AT THE RISK OF THE CONTRACTOR OR THE OWNER THEREFORE AND THE OWNERS SHALL NOT BE LIABLE TO THE CONTRACTOR FOR ANY DAMAGE TO ANY PERSONAL PROPERTY. 1.4 THE CONTRACTOR WILL CONFINE THE CONSTRUCTION DEBRIS AND DUST TO THE CONSTRUCTION AREA, AWAY FROM COMPLETED TENANT SPACE OR COMMON AREAS, ALL AREAS OF THE BUILDING, ESPECIALLY ACCESS AREAS AND COMMON AREAS, ARE TO BE MAINTAINED IN A CLEAN AND ORDERLY FASHION. THE CONTRACTOR IS TO TURN THE IMPROVED PREMISES OVER THE PROPERTY MANAGER IN A CLEAN CONDITION, READY FOR OCCUPANCY BY THE TENANT. 1.5 THE CONTRACTOR WILL REMOVE ALL TRASH AND DEBRIS, INCLUDING EXCESS MATERIALS FROM THE CONSTRUCTION SITE AND THE BUILDING AND NO UNREASONABLE ACCUMULATION BE ALLOWED. 1.6 THE CONTRACTOR WILL COORDINATE THE DELIVERY OF MATERIALS AND THE USE OF THE FREIGHT ELEVATOR AND REMOVAL OF DEBRIS WITH THE PROPERTY MANAGER 1.7 THE CONTRACTOR IS RESPONSIBLE FOR ALL PARKING CHARGES OF HIS EMPLOYEES, SUB- CONTRACTORS, AND VENDORS. 1.8 THE CONTRACTOR WILL SUBMIT ALL CHANGES ORDERS TO THE CLIENT FOR APPROVAL AND THE DRAWINGS ARE TO BE REVISED ACCORDINGLY. 1.9 THE CONTRACTOR WILL EXERCISE ALL DUE DILIGENCE IN MAINTAINING IN A SAFE WORKING ENVIRONMENT AND TO ABIDE BY ALL OSHA REGULATIONS. 1.10 UPON COMPLETION, THE CONTRACTOR WILL REMOVE ALL FOREIGN MATERIALS FROM WINDOWS, FLOORS, GLASS, HARDWARE AND RESTROOM FIXTURES. 1.11 THE CONTRACTOR WILL NOT UNDULY DISTURB THE PEACEFUL ENJOYMENT OF ANY TENANTS IN THE BUILDING. ALL DRILLING THROUGH THE CONCRETE FLOOR SLAB IS TO BE SCHEDULED WITH THE PROPERTY MANAGER. ALL PLUMBING INSTALLATIONS REQUIRING ACCESS TO OTHER AREAS OF THE BUILDING WET COLUMN WILL BE COORDINATED WITH THE PROPERTY MANAGER. 1.12 THE CONTRACTOR WILL INSTALL CONSTRUCTION AIR CONDITIONING FILTERS IN ALL RETURN AIR DAMPERS IN THE DEMISING WALLS IN ORDER TO PREVENT CONSTRUCTION DUST FROM ENTERING THE MAIN AIR CONDITIONING SYSTEM. 1.13 THE CONTRACTOR IS TO PROVIDE FIVE (5) COPIES OF ALL SHOP DRAWINGS, PRODUCT INFORMATION SUBMITTALS, AND ALL OTHER SUBMITTALS REQUIRED FOR REVIEW, ETC. AT LEAST TWO (2) OF THE ABOVE COPIES SHALL BE ORIGINALS. 1.14 THE CONTRACTOR SHALL VISIT THE JOB SITE AND VERIFY ALL CONDITIONS OF THE WORK PRIOR TO SUBMITTING A BID. 1.15 THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD. DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO THE COMMENCING OF THE WORK IN THE AREA IN QUESTION. 1.16 ALL WORK SHALL BE DONE IN ACCORDANCE TO THE LATEST EDITION OF THE FLORIDA BUILDING CODE 2001 EDITION AND ANY APLICABLE CODE. 1.17 IMPACT FEES, WATER AND SEWER CONNECTION FEES AND DEPOSITS FOR PERMANENT UTILITY SERVICES SHALL BE PAID FOR THE BY OWNER. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND /OR THE OWNER WHEN THESE FEES APPLY PRIOR TO THE START OF THE CONSTRUCTION OF THIS PROJECT. 1.18 THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR ALL PREFABRICATED ITEMS OF THE WORK INCLUDING BUT NOT LIMITED TO THE FOLLOWING PREFAB STAIR, WHEELCHAIR LIFT, STOREFRONT DOORS, CABINETS, AIR CONDITIONING, ETC. THE CONTRACTOR SHALL OBTAIN THE ARCHITECT'S WRITTEN APPROVAL OF SHOP DRAWINGS PRIOR TO THEIR FABRICATION. SAMPLES SHALL BE SUBMITTED UPON REQUEST. 1.19 WHERE EXISTING WALLS, CEILINGS OR FIXTURES ARE REMOVED: WALLS CEILINGS AND FLOORS SHALL BE PATCHED; ELECTRIC AND PLUMBING SHALL BE CAPPED. 1.20 PROVIDE 1 -3 ABC RATED FIRE EXTINGUISHER PER 2500 SQ. FT., AND MAXIMUM INTERVALS OF 75' -0". FIRE EXTINGUISHER SHALL BE BLDG. STANDARD, RECESSED TYPE CONTRACTOR SHALL VERIFY. GENERAL NOTES (CONT. 1.21 ANY ITEM OF WORK NECESSARY TO THE PROPER COMPLETION OF CONSTRUCTION WHICH IS NOT SPECIFICALLY COVERED IN THESE DOCUMENTS SHALL BE PERFORMED IN A MATTERS DEEMED GOOD PRACTICE OF THE TRADE INVOLVED. 1.22 ALL NEWS MATERIALS AND FINISHES SHALL MATCH EXISTING UNLESS SPECIFIED OTHERWISE, SEE OWNER AND /OR ARCHITECT FOR APPROVAL OF ALTERNATIVES. 1.23 BUILDING HAS A COMPLETE FIRE SPRINKLER SYSTEM. SUBMIT SHOP DRAWINGS FOR THE RELOCATION AND CONDITION OF SPRINKLER HEADS.SPRINKLER HEADS SHALL MATCH EXISTING. 1.24 NOT USED 1.25 CONTRACTOR SHALL PREPARE EXISTING AND NEW FLOOR SURFACES FOR PROPER LEVELING TO RECEIVE NEW NEW PROPOSED FLOOR FINISHES. 1.26 CONTRACTOR IS TO PROVIDE PROPER BACKING AND BRACING AT ALL AREAS TO RECEIVE MILLWORK CABINETS, SHELVING, ETC. 1.27 ALL PROPOSED MILLWORK CONSTRUCTION SHALL COMPLY WTH AN CUSTOM STANDARDS, TYP. 1.28 CONTRACTOR SHALL COORDINATE AT ROUGH FRAMING PRIOR TO INSTALLATION OF GYPSUM WALL BOARD ALL PROPOSED CONDUIT TYPES RUNS AND LOCATIONS W/ LOW VOLTAGE VENDOR. TYP. 1.29 USE AND INTERPRETATION OF THIS DRAWING A. GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION, AIA DOCUMENT A201, ARE A PART OF A CONTRACT DOCUMENT AS DESCRIBE USE AND INTENT OF THE DRAWINGS. THE CONTRACT DOCUMENTS INCLUDE NOT ONLY THE DRAWINGS, BUT ALSO THE OWNER - CONTRACTOR AGREEMENT, CONDITIONS OF THE CONTRACT, THE SPECIFICATIONS, ADDENDA, AND MODIFICATIONS ISSUED AFTER EXECUTION OF THE CONTRACT. THESE CONTRACT DOCUMENTS ARE COMPLEMENTARY, AND WHAT IS REQUIRED BY ANY ONE SHALL BE BINDING AS IF REQUIRED BY ALL. WORK NOT COMPLETELY DELINEATED HEREON SHALL BE CONSTRUCTED OF THE SAME MATERIALS AND DETAILED SIMILARLY AS WORK SHOWN MORE COMPLETELY ELSEWHERE IN THE CONTRACT DOCUMENTS. B. BY USE OF THE DRAWINGS FOR CONSTRUCTION OF THE PROJECT THE OWNER REPRESENTS THAT HE HAS REVIEWED AND APPROVED THE DRAWNGS, AND THAT THE CONSTRUCTION DOCUMENT PHASE OF THE PROJECT IS COMPLETE. THE CONTRACTOR REPRESENTS THAT HE HAS VISITED THE SITE, FAMILIARIZED HIMSELF WITH THE LOCAL CONDITIONS, VERIFIED FIELD DIMENSIONS AND CORRELATED HIS OBSERVATIONS WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. C. THE CONTRACT SUM AND THE CONTRACT TIME MAY BE CHANGED ONLY BY CHANGE ORDER TO THE CONTRACTOR SIGNED BY THE OWNER AND THE ARCHITECT. ANY WORK PERFORMED IN VARIANCE WITH THE CONTRACT DOCUMENTS AND NOT COVERED BY THE ARCHITECT'S WRITTEN ORDER FOR A MINOR CHANGE IN THE WORK OR A CHANGE ORDER, WILL NOT BE ACCEPTED. D. AS INSTRUMENTS OF SERVICE, ALL DRAWINGS, SPECIFICATIONS AND COPIES THEREOF FURNISHED BY THE ARCHITECT ARE HIS SPECIFICATIONS AND PROPERTY. THEY ARE TO BE USED ONLY FOR THIS PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT. CHANGES TO THE DRAWINGS NOT TO BE USED ON ANY OTHER PROJECT. CHANGES TO THE DRAWINGS MAY ONLY BE MADE BY THE ARCHITECT. ANY SUBMISSION OR DISTRIBUTION WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT MAY BE CONSTRUED AS DEROGATION OF THE ARCHITECT COPYRIGHT OR OTHER RESERVED RIGHTS. 1.30 ALL WORK SHALL BE CONSTRUCTED IN ACCORDANCE WITH ADA ACCESSIBIUTY GUIDELINES AS SET FORTH IN THE AMERICANS WTH DISABILITIES ACT HANDBOOK. AS PUBLISHED BY THE EQUAL OPPORTUNITY COMMISSION AND THE U.S. DEPARTMENT OF JUSTICE ON OCTOBER 1991. THE CONTRACTOR AND SUBCONTRACTORS SHALL BE RESPONSIBLE FOR THE IMPLEMENTATION OF SUCH. CONSTRUCTION PLAN NOTES 2.1 PRIOR TO START OF CONSTRUCTION, GC SHALL COORDINATE SCHEDULING OF MEETING WITH HIS PROJECT PERSONNEL, THE BUILDING /LANDLORD REP(S), ARCHITECT PROJECT MANAGER, OTHERS, FOR REVIEW OF PROJECT SCOPE, DESIGN INTENT, CONSTRUCTION QUALITY EXPECTED, & FINAL DISCUSSION OF DRAWINGS /DETAILS /QUESTIONS. 2.2 DIMENSIONS ON DRAWINGS ARE FINISH FACE TO FINISH FACE OF PARTITIONS, COLUMNS, ETC., OR TO WHERE SHOWN, UNLESS OTHERWISE NOTED. DO NOT SCALE DRAWINGS WRITTEN DIMENSIONS TAKE PRECEDENCE OVER GRAPHIC REPRESENTATION. DETAIL DIMENSIONS TAKE PRECEDENCE OVER PLAN DIMENSION. 2.3 GC SHALL BE RESPONSIBLE FOR FIELD MEASURING OF EXISTING CONDITIONS PRIOR TO START OF WORK AND DURING CONSTRUCTION, AS NECESSARY, TO ASSURE CONSTRUCTION ADHERENCE TO DRAWINGS. BY ENTERING INTO A CONSTRUCTION CONTRACT FOR THIS WORK, GC SHALL INDICATE HIS FAMILIARITY WTH THE SITE /FIELD, CONDITIONS. A. ALL 'HOLD' DIMENSIONS SHALL BE MONITORED TO ASSURE CORRECTNESS. B. ANY DIMENSION REVISIONS /MODIFICATIONS ARE TO BE BROUGHT TO ATTENTION OF ARCHITECT PROJECT MANAGER FOR REVIEW /APPROVAL. 2.4 ALL VERTICAL DIMENSIONS SHALL BE TAKEN FROM "BENCH MARK" OR OTHER SIMILAR GUIDE ESTABLISHED PRIOR TO START OF CONSTRUCTION. HIGH POINTS, LOW POINTS IRREGULARITIES IN FLOOR LOOR SLAB, PARTICULARLY, WHICH COULD IN ANY WAY AFFECT FABRICATION /INSTALLATION WORK OF OTHER TRADES OR VENDORS (E.G., CABINET CONTRACTORS), SHALL BE BROUGHT TO ATTENTION OF ARCHITECT. A. VARIATIONS IN FLOOR LEVEL IN EXCESS OF 1/2" FOR EVERY 10' -0" IN EVERY DIRECTION WILL REQUIRED LEVELING OF SLAB BY G.C. OR LANDLORD AS PREDICATED BY FINAL LEASE AGREEMENT. LEVELING OF SLAB TO BE DONE READY TO RECEIVE ARCHITECT FLOOR FINISHES, I.E. VINYL TILE FLOORS, CARPETING, ETC. GENERAL CONTRACTORS TO VERIFY SLAB CONDITION PRIOR TO BID SUBMISSION. 2.5 GC SHALL DEMOLISH EXISTING PARTITION AND VARIOUS OTHER ELEMENTS AS INDICATED ON PLAN AND COORDINATE THE REMOVAL OF ALL RELATED ELECTRICAL SERVICE, PLUMBING AND ALL OTHER APPURTENANCES INCLUDED THEREIN, REFER TO GENERAL DEMOLITION NOTES. 2.6 GC SHALL BE RESPONSIBLE FOR THE REMOVAL OF ALL CONSTRUCTION DEBRIS AND FOR THE RETURN OF ANY BUILDING STANDARD COMPONENTS IF REQUESTED BY THE BUILDING MANAGEMENT UNLESS OTHERWISE NOTED ON C'D'S CONSTRUCTION PLAN NOTES(CONT) 2.7 ALL EXISTING DOORS DESIGNATED FOR REMOVAL, INCLUDING FRAMES, SHALL BE REUSED WHERE SAME TYPE DOOR IS APPLICABLE AND /OR IS CALLED FOR IN NEW DESIGN WHENEVER POSSIBLE. ALL EXISTING HARDWARE SHALL BE RETAINED FOR REUSE: COORDINATE WITH ARCHITECT PROJECT MANAGER UNLESS OTHERWISE NOTED ON C'D'S 2.8 ALL CONVENTIONAL DRYWALL CONSTRUCTION, FURRING, SHEATHING, THIS CONTRACT, SHALL BE AS DETAILED (REFER TO LEGEND ENTRIES, ON CONSTRUCTION PLAN). DRYWALL JOINTS SHALL BE TAPED /SPACKLED LEVEL. EXTERIOR CORNERS SHALL RECEIVE METAL CORNER REINFORCING BEAD AND BE SPACKLED IN CONVENTIONAL MANNER. NO HORIZONTAL DRYWALL JOINTS SHALL BE ACCEPTED UNLESS APPROVED BY ARCHITECT. BUTTED, UNTAPED DRYWALL JOINTS ARE NOT ACCEPTABLE. FULL HEIGHT GYPSUM BOARD SHEETS SHALL BE USED THROUGHOUT FOR FULL HEIGHT CONSTRUCTION. A. ALL NEW DRYWALL CONSTRUCTION SHALL BE PROPERLY PREPARED TO RECEIVE SPECIFIED FINISH MATERIAL(S) IN MANNER FULLY ACCEPTABLE TO ARCHITECT. B. TAPED JOINTS, CORNERS, 'DIMPLES' OR SCREW HEADS SHALL BE SPACKLED SMOOTH AND GYPSUM LEVEL WITH ADJACEN T G SU M BOARD SURFACE. NO BULGING OR UNEVEN FINISHED DRYWALL WILL BE ACCEPTED. 2.9 ALL EXISTING HOLES /CRACKS IN SLAB AND THOSE RESULTING FROM THE CONSTRUCTION PROCESS SHALL BE FILLED /REPAIRED AND THE SURFACE PATCHED SMOOTH AND LEVEL WTH ADJACENT FLOOR SURFACE, IN A MANNER ACCEPTABLE TO THE ARCHITECT. 2.10 ALL NECESSARY WOOD BLOCKING /GROUNDS, ETC., ARE TO BE SUPPLIED AS FACTORY TREATED FIRE- PROOFED ELEMENTS. GC SHALL FULLY COORDINATE SETTING /PLACEMENT OF THESE ELEMENTS AS REQ'D BY LOCAL CODE /BUILDING OR SURROUNDING CONSTRUCTION CONDITIONS. A. GROUNDS /BLOCKING MAY NOT BE WHOLLY SHOWN ON DRAWNGS AND GOOD CONSTRUCTION PRACTICE SHALL GOVERN/ DETERMINE SAID USE WHERE A QUESTION ARISES. B. GC TO PAY PARTICULAR ATTENTION TO ALL LOCATIONS OF DRYWALL PARTITION CONSTRUCTION THAT ABUT OR RECEIVE MILLWORK OR CABINETWORK CONSTRUCTION. INTERNAL WOOD BLOCKING SHALL BE SUPPLIED FOR STURDY ANCHORAGE AT INTERSECTIONS OF WOOD /GLASS BORROWED LIGHT PARTITIONS AND ADJACENT DRYWALL CONSTRUCTION, AS REQUIRED. C. BLOCKING FOR ALL MILLWORK INSTALLATIONS, BUILT -IN FURNITURE, DRAPERY TRACKS AND PRESENTATION BOARDS SHALL BE PROVIDED BY GC. REFER TO FURNITURE PLAN AND FINISH PLAN FOR COMPLETE SCOPE. REFER TO MECHANICAL PLAN FOR BLOCK REQUIREMENTS FOR WALL MOUNTED HVAC EQUIPMENT IN TELEPHONE EQUIPMENT ROOM. 2.11 GC SHALL PROVIDE GENERAL CARPENTRY AS REQUIRED FOR WORK WHICH MAY NOT FALL INTO JURISDICTION OF A SPECIFIC TRADE, BUT IS REQUIRED FOR PROPER JOB EXECUTION AND COMPLETION OF CONSTRUCTION. 2.12 INSTALL ALL PLUMBING NECESSARY FOR THE INDICATED PLUMBING FIXTURES /APPURTENANCES. SAID UNITS SHALL BE AS SPECIFIED. (REFER TO MECHANICAL PLANS.) 2.13 ANY ACCESS PANELS REQUIRED IN ANY CONSTRUCTION THIS CONTRACT SHALL BE APPROVED AS TO SPECIFIC SIZE, LOCATION, FINISH, ETC., BY ARCHITECT. 2.14 GC, SUBCONTRACTORS, AND ALL VENDORS ARE TO VERIFY ALL CLEARANCES (CORRIDORS, STAIRS, ELEVATORS, ETC.) REQUIRED FOR DELIVERIES, PASSAGE OF ALL JOB MATERIALS /EQUIPMENT. A. GC SHALL SCHEDULE FOR AND INCLUDE COSTS/ FEES NECESSARY FOR USE OF BUILDING ELEVATOR OR ANY SPECIAL CARTAGE, RIGGING, HOISTING, DELIVERIES, TRANSPORTATION, ETC. CONNECTED WITH CONTRACT WORK. B. GC SHALL COORDINATE CLOSELY WTH VARIOUS ARCHITECT VENDORS OR CONTRACTORS, REGARDING INFORMATION IN PART "A" THIS NOTE ABOVE REFLECTED CEILING/ MECH. SYST.NOTES CONT. 3.11 HVAC SUPPLY, RETURN, EXHAUST GRILLES SHALL BE AS SPECIFIED IN MECHANICAL DRAWINGS OR "BUILDING STANDARD" IF NOT SPECIFIED. GC TO VERIFY CONFORMANCE OF SPEC WITH BUILDING STANDARDS. ALL HVAC ELEMENTS SHALL BE OFF -WHITE (TO MATCH CEILING) INSTALLED FLUSH AND TRUE AND CENTERED WITHIN THE CEILING GRID. LOCATIONS SHALL BE PER APPROVED MECHANICAL PLANS,UNLESS OTHERWISE NOTED ON CD'S.. 3.12 ARCHITECTURAL CEILING PLAN SHALL GOVERN WTH RESPECT TO LOCATIONS FOR CEILING PENETRATIONS AS AESTHETIC AND FUNCTIONAL CONSIDERATIONS DICTATE. MECHANICAL DOCUMENTS SHALL TAKE PRECEDENCE WTH RESPECT TO OVERALL SCOPE OF WORK. 3.13 DUCTWORK, WHEN CONTINUOUS THROUGH MORE THAN ONE ROOM, SHALL BE ACOUSTICALLY LINED TO DIMINISH SOUND TRANSMISSION THROUGH DUCTS. 3.14 CLEARANCES FOR ALL RELATED CEILING PLENUM THAN ONE ROOM, SHALL BE ACOUSTICALLY LINED NO ADDITIONAL COST. 3.15 SPECIAL COOLING REQUI REM ENTS/SUPPLEN MENTAL SYSTEM SHALL BE DESIGNED AND SPECIFIED IN THE MECHANICAL CD'S CO NTRACTOR SHALL COORDINATE ABOVE CEILING CONDITIONS FOR THIS INSTALLATION. 3.16 NOT USED 3.17 FIRE PROTECTION SYSTEMS AS SPECIFIED OR REQUIRED BY CODE, SHALL BE PROVIDED BY GC. MINIMUM SPRINKLER INSTALLATION MUST MEET REQUIREMENTS OF NFPA 13. 3.18 SPRINKLER HEAD LOCATION SHALL BE COORDINATED WTH OTHER TRADES BY GC AND SHALL BE AS SPECIFIED BY ENGINEER OR AS REQ'D BY CODE. SPRINKLERS SHALL BE CENTERED WTHIN EACH CEILING TILE TO PROVIDE A UNIFIED, CONSISTENT AND AESTHETIC ARRANGEMENT. HEADS SHALL BE WHITE FLUSH TYPE OR BUILDING STANDARD IF EQUAL OR BETTER. 3.19 LIGHTING FIXTURES, EXIT LIGHTS, SWITCHING, ETC. SHALL BE PROVIDED BY GC. ARCHITECTURAL PLAN SHALL GOVERN LOCATION, ENGINEERING PLANS SHALL PREVAIL IN QUESTIONS OF CIRCUITING AND SCOPE. 3.20 CUT SHEETS FOR ALL FIXTURES SHALL BE SUBMITTED ARCHITECT SB BY GC FOR REVIEW /APPROVAL. SUBSTITUTIONS MUST BE APPROVED BY ARCHITECT. 3.21 EMERGENCY LIGHTING AND ANNUNCIATOR / ALARM SYSTEMS SHALL BE SPECIFIED BY ENGINEER. 3.22 NEW SWITCHES SHALL MATCH EXISTING TYPE USED WHERE EXISTING SWITCHES ARE TO REMAIN. 3.23 ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST "NATIONAL ELECTRICAL CODE' AND ANY AND ALL APPLICABLE STATE AND LOCAL CODES /ORDINANCES. 3.24 CLEANING: BEFORE JOB COMPLETION, THE FOLLOWING SHALL BE SATISFIED: A. ALL LIGHT FIXTURE INTERIORS AND LENSES SHALL BE WIPED CLEAN OF ALL CONSTRUCTION DUST, GRIME, FINGERMARKS, ETC., AND BE FULLY FUNCTIONING, MECHANICALLY AND ELECTRICALLY. B. ALL LAMPING WILL BE NEW AND FUNCTIONAL. C. RECESSED INCANDESCENT FIXTURES SHALL BE SIMILARLY CLEANED AND BE FUNCTIONAL AND SHALL BE AIMED, IF CALLED FOR, PER REFLECTED CEILING PLAN. 3.25 PROTECTION: ALL ELECTRICAL ELEMENTS, WHEN INSTALLED, SHALL BE PROTECTED FROM DAMAGE BY OTHER TRADES. COVER PLATES SHALL BE INSTALLED AFTER FINISH MATERIALS HAVE BEEN APPLIED. 3.26 MAINTENANCE CONTRACT FOR SUPPLEMENTAL AIR CONDITIONING SYSTEMS INSTALLED UNDER THIS CONTRACT SHALL BE SUBMITTED TO ARCHITECT BY MECH CONTRACTOR FOR REVIEW. SERVICES TO BE INCLUDED SHALL BE AS RECOMMENDED BY MANUFACTURER. CONTRACT TO BE ONE -YEAR TERM, RENEWABLE FOR ONE YEAR. 3.27 WARRANTIES FOR SUPPLEMENTAL COOLING EQUIPMENT SHALL BE EXTENDED TO 5 YEARS ON COMPRESSORS AND WHERE UNITS INCLUDE A PACKAGED SEALED HERMETIC REFRIGERANT SYSTEM, SHALL COVER THE ENTIRE SYSTEM. 2.15 EXISTING GYPSUM BOARD IN, ANY AREA OF Client Name T (� , THIS PROJECT (TO INCLUDE CORE AND PERIMETER ') a4 . t' . COLUMNS AND WALLS) SHALL BE PATCHED, 1696 NE MIAMI GARDENS DR ELECTRICAL PLAN NOTES SPACKLED, AS REQUIRED, IF DAMAGED IN ANY Scale N. MIAMI BEACH, FL 33179 MANNER, DURING CONSTRUCTION TO SATISFACTION y ' OF ARCHITECT & THE BUILDING. 4,1 SCOPE: GC SHALL PROVIDE ALL ELECTRICAL 2.16 HARDWARE SHALL BE PROVIDED BY GC AS WORK AS SHOWN OR IMPLIED IN THESE SPECIFIED. SEE MILLWORK DETAILS AND NOTES Vk .��y , DRAWINGS AND RELATED ENGINEERING FOR SCOPE OF WOODWORKING AND HARDWARE. '' "AR- DRAWINGS (IF ANY) INCLUDING ALL CONDUIT 2.17 ALL SUBSTITUTIONS, I.E., "EQUALS" MUST BE RUNS FOR POWER AND SIGNAL; DRAG LINES; SUBMITTED TO ARCHITECT PROJECT MANAGER FOR PULL BOXES; WIRING; RECEPTACLES AND WRITTEN APPROVAL PRIOR TO SUBSTITUTION BEING SWITCHING DEVICES; CORE DRILLING AND MADE. PATCHING; ETC.; AS SPECIFIED OR IMPLIED OR 2.18 GC SHALL REMOVE EXISTING FLOOR COVERING AS REQUIRED BY CODE OR BUILDING WHENEVER DESIGNATED FOR REMOVAL. STANDARDS. 4.2 EQUIPMENT: TELEPHONE AND DATA 2.19 DEMISING PARTITIONS SHALL BE SPECIFIED EQUIPMENT, TERMINALS, ETC., EXCEPT AS WITH SOUND ATTENUATION BATTING, SPECIFICALLY CALLED FOR, SHALL BE UNLESS NOTED IN CD'S. PROVIDED BY OTHERS. GC SHALL PROVIDE FOR 2.20 SOUND ATTENUATION BATTING SHALL BE SPECIFIED COORDINATION WITH VENDORS/ INSTALLERS AS PER CD'S. REGARDING DELIVERIES, SCHEDULES, AS 2.21 SOUND ATTENUATION BATTING SHALL BE SPECIFIED DIRECTED BY ARCHITECT. AT ALL PARTITIONS AND CEILING FOR NEW RESTROOMS. 4.3 LOCATIONS AND DIMENSIONS SHALL BE PER ARCHITECTURAL DRAWINGS; ENGINEERING REFLECTED CEILING AND DOCUMENTS (IF ANY) SHALL PREVAIL IN CASE OF VARIATION IN SPECIFICATIONS. DISCREPANCIES MECHANICAL SYSTEMS NOTES MUST BE BROUGHT TO THE ATTENTION OF ARCHITECT BEFORE START OF WORK. FURNITURE 3.1 SCOPE: GC SHALL FURNISH AND INSTALL INDICATED ON PLANS IS FOR REFERENCE ONLY. SUSPENDED GRID AND ACOUSTICAL TILE 4.4 VARIATIONS FROM WORK SPECIFIED DUE TO CEILING MATERIAL AS SPECIFIED AND AS INDICATED AVAILABILITY OF MATERIALS; FIELD CONDITIONS, ON PLAN AND PROVIDE CUT OUTS AND OTHER VARIATIONS IN EQUIPMENT SPECS, ETC., MAY BE PROVISIONS FOR OTHER TRADES AS REQUIRED. MADE WITH THE APPROVAL OF ARCHITECT. 3.2 CEILING GRID SYSTEM SHALL BE IN CONFORMANCE WITH 4.5 FIELD VERIFICATIONS: G.C. AND ASTM C 635 AND WITH GENERAL PRACTICES AND SUBCONTRACTORS SHALL BE RESPONSIBLE TO APPLICABLE STATE AND LOCAL ORDINANCES. INSTALLATION VERIFY FIELD CONDITIONS AND DIMENSIONS SHALL BE IN CONFORMANCE WITH MANUFACTURERS BEFORE BEGINNING WORK. SIZES OF CONDUITS RECOMENDATIONS AND ASTM C 636. AND PULL BOXES SHALL BE ADEQUATE FOR CABLES /SERVICE SPECIFIED. 3.3 GC SHALL VERIFY CONFORMANCE WITH LOCAL AND STATE CODES AND BUILDING STANDARDS BEFORE 4.6 ADJACENT TENANTS: GC SHALL INCLUDE SUBMITTING FINAL PRICING. REPAIRS TO ADJACENT TENANT SPACES WHEN 3.4 CEILING PLANE SHALL BE LEVEL AND TRUE, AND IN WORK AFFECTS THOSE AREAS. WORK IN ALIGNMENT WITH ALL LIGHTING, SPRINKLER, HVAC AND ADJACENT TENANT SPACES SHALL NOT BE OTHER ELEMENTS INCORPORATED IN ITS CONSTRUCTION. SCHEDULED DURING NORMAL WORKING HOURS. GRID SHALL BE CONTINUOUS THROUGHOUT THE DEMISED 4,7 COMPLIANCE: ALL WORK SHALL BE PERFORMED AREA EXCEPT WHERE NOTED ON CDs. IN COMPLETE COMPLIANCE WITH THE NATIONAL 3.5 PARTITIONS SHALL PENETRATE THE CEILING PLANE ELECTRICAL CODE AND /ALL STATE OR LOCAL (SEE CONSTRUCTION PLAN). ACOUSTICAL CONTRACTOR CODES AND ORDINANCES HAVING JURISDICTION. SHALL COORDINATE WORK WTH CARPENTRY TRADES 4.8 COMPATIBILITY: ALL DEVICES, WIRING, ETC. TO PROVIDE FOR A NEAT, LEVEL VISUAL LINE AT THE SHALL BE COMPATIBLE, EACH WITH ONE INTERSECTION OF CEILING AND PARTITIONS. ANOTHER AND WITH EXISTING WORK AND 3.6 FASCIAS /SOFFITS SHALL BE LEVEL AND TRUE, FREE BUILDING STANDARDS. OF SURFACE DISTORTION AND DIMENSIONED 4.9 CIRCUITING SHALL BE AS SHOWN ON ENGINEERING ACCORDING TO DETAILS SHOWN. DOCUMENTS. 3.7 MECHANICAL, HVAC AND PLUMBING ELEMENTS 4.10 PROTECTION: ALL ELECTRICAL DEVICES, WHEN SHALL AT NO TIME COME IN CONTACT WITH CEILING INSTALLED, SHALL BE PROTECTED FROM CONSTRUCTION EXCEPT AS NECESSARY DAMAGE BY OTHER TRADES. COVER PLATES PENETRATIONS MAY REQUIRE. SHALL BE INSTALLED AFTER FINISH MATERIALS 3.8 ACCESS SHALL BE PROVIDED BY GC AS REQUIRED HAVE BEEN APPLIED. SEE FINISH PLAN. FOR INSTALLATION AND MAINTENANCE OF 4.11 FLOOR OUTLETS SHALL BE FLUSH TYPE UNLESS MECHANICAL, ELECTRICAL AND OTHER ELEMENTS PROHIBITED BY BUILDING MANAGEMENT. GC. WITHIN CEIUNG PLENUM AND AS REQUIRED BY SHALL FURNISH CUT /SAMPLE TO ARCHITECT FOR CODE. LOCATIONS FOR SPECIAL ACCESS DOORS, APPROVAL. UNDER CARPET WRING MAY NOT BE HATCHES, ETC. SHALL BE COORDINATED WTH USED EXCEPT AS SPECIFIED AND AS LOCAL OTHER TRADES AND APPROVED BY ARCHITECT. AS -BUILT CODES AND BUILDING MANAGEMENT PERMITS. REFERENCE PLANS SHALL BE PROVIDED TO ARCHITECT. 3.9 INSPECTIONS, AS REQUIRED BY LOCAL AUTHORITIES 4.12 SURFACE MOUNTED WRING DEVICES SHALL SHALL BE COORDINATED BY GC PRIOR TO CLOSING NOT BE USED BY GC, HIS SUBS OR ANY OF CEILING. ELECTRICAL VENDOR OR INSTALLER, EXCEPT AS 3.10 SHOP DRAWINGS FOR ALL RELATED TRADES PLUMBING, ( SPECIFIED TO COORDINATE WITH FURNITURE /MILLWORK INSTALLATION. SPRINKLER, HVAC) SHALL BE SUBMITTED TO ARCHITECT FOR REVIEW /APPROVAL PRIOR TO MANUFACTURING AND 4.13 COORDINATION OF ELECTRICAL WORK WITH INSTALLATION. A COORDINATED SHOP DRAWING FOR HVAC, CABINET WORK, CARPENTRY, FURNITURE, ALL VISIBLE CEILING ELEMENTS SHALL BE SUBMITTED. SHALL BE ASSURED BY GC. ELECTRICAL PLAN NOTES CONT. 4.13 COORDINATION OF ELECTRICAL WORK WITH HVAC, CABINET WORK, CARPENTRY, FURNITURE, SHALL BE ASSURED BY GC. 4.14 RACEWAYS PROVIDED BY OTHERS WITHIN CUSTOM CABINETRY AND MILLWORK OR OFFICE LANDSCAPE PARTITION SYSTEMS SHALL BE USED FOR ELECTRICAL INSTALLATIONS. 4.15 OFFICE LANDSCAPE PARTITIONS: MODULAR POWER WAYS AND RECEPTACLE DEVICES FOR ELECTRICAL SERVICE IN LANDSCAPE PARTITIONS SHALL BE PROVIDED BY FURNITURE VENDOR (EXCEPT WHERE PROHIBITED BY CODE). ELECTRICAL SUBCONTRACTOR TO PROVIDE FOR SERVICE TO POINT OF INTERFACE WITH LANDSCAPE PANELS AND TO INSTALL DEVICES IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 4.16 AVAILABILITY OF ADEQUATE POWER SERVICE SHALL BE VERIFIED BY ELECTRICAL CONTRACTOR. COSTS FOR ADDITIONAL CIRCUIT PANELS, TRANSFORMERS, ETC., IF REQUIRED, SHALL BE INCLUDED IN BASE BID. 4.17 CONNECTION OF SERVICES: ELECTRICAL CONTRACTOR SHALL PROVIDE FOR CONNECTION OF TENANT TELEPHONE ROOM WTH BUILDING TELEPHONE CLOSET AS REQ'D. 4.18 EXISTING SIGNAL CABLES, IF IN USE BY RESIDING TENANTS, MAY NOT BE DISTURBED OR CUT. GC SHALL BE RESPONSIBLE TO RESTORE ANY SERVICES WHICH ARE INADVERTENTLY INTERRUPTED. 4.19 RAISED FLOOR AREAS WHEN SPECIFIED SHALL BE PROVIDED WITH POWER GRID OF JUNCTION BOXES MOUNTED TO SLAB WITH FLEXIBLE CONNECTIONS MADE TO FLOOR MOUNTED SERVICE. PROVIDE SUITABLE RECESSED SERVICE BOX WITH ACCESS LID TO ACCEPT RECEPTACLE DEVICES AND CABLE TERMINATION DEVICES. 4.20 REFER TO SCOPE OF MECHANICAL AND HVAC INSTALLATIONS FOR RELATED ELECTRICAL WORK TO BE INCLUDED. 4.21 BACK -TO -BACK ELECTRICAL OUTLETS MAY SHARE COMMON DOUBLE ACCESS SERVICE BOX AND CONDUIT SIZED FOR DOUBLE USE. (USE 2 -1/4" EXTENSION COLLAR WTH MUD -RINGS BOTH SIDES.) 4.22 SLEEVES SHALL BE PROVIDED BY GC TO ALLOW DATA / TELEPHONE CABLES TO PASS THROUGH FIRE RATED PARTITIONS AND SHALL BE FIRESTOPPED BY G.C. FURNITURE PLAN NOTES 5.1 SCOPE: ALL FURNITURE SHOWN IS TO BE PROVIDED BY VENDORS OTHER THAN GC. SCOPE OF WORK BY GC RELATED TO COORDINATION OF INSTALLATION WITH VENDORS IS NOTED. 5.2 ALL FURNITURE AND EQUIPMENT IS NEW EXCEPT AS NOTED. 5.3 FURNITURE SUPPLIER IS TO PROVIDE AND INSTALL ALL FURNISHINGS SPECIFIED AS SHOWN WTH NO SUBSTITUTIONS. PRICES ARE TO INCLUDE SHIPPING AND FREIGHT CHARGES AND FEES, LICENSE, PERMITS AND INSTALLATION BY QUALIFIED LABOR DURING NORMAL BUSINESS HOURS. OVERTIME DELIVERIES, IF REQUIRED BY BUILDING MANAGEMENT ARE TO BE COORDINATED WTH AND APPROVED BY ARCHITECT. 5.4 VENDOR SHALL ALLOW FOR ANY BUILDING ELEVATOR USE FEES, LOADING DOCK FEES, ETC. AND SHALL COORDINATE DELIVERY SCHEDULES WITH BUILDING MANAGEMENT AND ARCHITECT. 5.5 VENDOR TO VERIFY CAPACITIES, DIMENSIONS OF FREIGHT ELEVATORS AND DELIVERY PATH TO ASSURE ADEQUATE PASSAGE. 5.6 COMPLIANCE WITH LOCAL CODES AND ORDINANCES SHALL BE THE RESPONSIBILITY OF FURNITURE Vfta4fIII>?2b9 G PAYMENT OF ANY FINES FOR 5.7 PROTECTION SHALL BE PROVIDED BY VENDOR FOR ALL SURFACES SUSCEPTIBLE TO DAMAGE DURING DELIVERY. VENDOR SHALL BE RESPONSIBLE TO CORRECT ANY DAMAGES CAUSED BY DELIVERY. 5.8 BUILT -IN FILES AND CABINETS REQUIRE COORDINATION WITH GC AND WORK BY OTHER TRADES SPECIFIED IN OTHER SECTIONS. FURNITURE VENDOR SHALL ASSEMBLE, PLACE AND LEVEL CABINETS WITHIN ENCLOSURES PROVIDED. (PLATFORMS, REVEAL STRIPS WORKTOPS, ETC., BY MILLWORK CONTRACTOR.) 5.9 FREESTANDING FILE BANKS SHALL BE LEVELED AND BOLTED TOGETHER BY VENDOR. 5.10 LOCKS ARE SPECIFIED FOR ALL FILE CABINETS. CABINETS WTHIN ONE BANK SHALL BE KEYED ALIKE 5.11 LOCKS WHEN SPECIFIED FOR OFFICE SUITES AND COMPONENT ASSEMBLIES SHALL BE KEYED ALIKE 5.12 TWO KEYS SHALL BE PROVIDED FOR EACH LOCK. 5.13 IDENTIFICATION NUMBERS /TAGS SHALL BE PROVIDED FOR ALL LOCKS AND KEYS. 5.14 CONTRACTOR SHALL COORDINATE ALL HARDWARE LOCKING REQUIREMENTS WITH TENANT, AND LANDLORD REP I FINISH PLAN NOTES I 6.1 ALL FINISH MATERIAL INDICATED TO BE BY GC UNLESS OTHERWISE NOTED IN FINISH SCHEDULES(S), ON FINISH PLAN. 6.2 GC AND VENDORS SHALL DETERMINE AVAILABILITY OF ALL FINISH MATERIALS. ANY DELIVERY SCHEDULE THAT POTENTIALLY MAY CAUSE COORDINATION PROBLEMS DURING THE FINAL STAGES OF CONSTRUCTION /INSTALLATION SHALL BE BROUGHT TO ATTENTION OF ARCHITECT , EARLY ON, FOR POSSIBLE REEVALUATION OF MATERIAL DESIGNATION. 6.3 A MINIMUM QUANTITY OF TWO (2) 1' -0" X 1' -0" FINISH SAMPLES OF ALL SPECIFIED FINISHES AND CURRENT STOCK CUTTINGS OF ALL SPECIFIED WALL - COVERINGS SHALL BE PROVIDED FOR APPROVAL PRIOR TO ORDERING. 6.4 PAINT FOR WALL FINISHES SHALL BE PROVIDED AS A THREE (3) COAT EGGSHELL LATEX ENAMEL PAINT APPLICATION [ONE (1) PRIME AND TWO (2) FINISHED COAT], COLORS AS SPECIFIED. METAL ELEMENTS AND DOOR AND WINDOW FRAMES SHALL HAVE A THREE COAT SEMI -GLOSS ALKYD ENAMEL FINISH. 6.5 GC SHALL ASSURE THAT NO ELECTRIC RECEPTACLE OR TELECOMMUNICATIONS OUTLET COVERPLATES HAVE BEEN INSTALLED PRIOR TO COMPLETION OF APPLICATION OF ANY WALL FINISH MATERIALS. ANY SUCH COVERPLATES OR SURFACE HARDWARE, ETC., IN PLACE, SHALL BE REMOVED PRIOR TO WALL FINISH APPLICATION. 6.6 UPON COMPLETION OF FINISH PHASE OF JOB, GC SHALL REMOVE ALL PAINT, WALLCOVERING PASTE, ETC., FROM WHERE IT HAS SPILLED, SPLASHED, OR SPATTERED. 6.7 GC SHALL INSTALL ALL WALLCOVERINGS WHERE DESIGNATED. ALL WALLCOVERING SHALL BE SMOOTH WITH NO WRINKLES, BUBBLES, BLISTERS, OR LOOSE EDGES. ALL EXCESS PASTE SHALL BE THOROUGHLY REMOVED. WALLCOVERING ADJOINING WOOD OR METAL PARTITIONS SHALL BE CUT STRAIGHT AND SQUARE. WALLCOVERING AT ALL REVEALS SHALL RETURN INTO REVEAL. ALL WORKMANSHIP WHICH IS NOT JUDGED TO BE FIRST QUALITY BY ARCHITECT WILL NOT BE ACCEPTED. NO WALLCOVERING SHALL TERMINATE ON A FLAT SURFACE OR ON AN OUTSIDE CORNER. ALL WALL - COVERING SHALL TERMINATE AT AN APPROPRIATE REVEAL /BREAK OR INSIDE CORNER. FINISH PLAN NOTES CONT. 6.8 ALL WALL SURFACES RECEIVING WALLCOVERING SHALL BE PRIMED WITH A SUITABLE STRIPPAAI F PRIMING MATERIAL. NO "ONE STEP" PRIMER /ADHESIVE SHALL BE USED. SAID PRIMER SHALL BE COMPATIBLE WITH THE RECOMMENDED ADHESIVE FOR RESPECTIVE WALL - COVERING BEING USED. 6.9 ALL PARTITIONS SHALL RECEIVE VINYL BASE INSTALL- ATION EXCEPT WHERE OTHERWISE NOTED. ALL SURFACES RECEIVING BASE SHALL BE PREPARED AS REQUIRED. A. AREAS INDICATED AS RECEIVING CARPET FLOOR FINISH SHALL HAVE STRAIGHT BASE APPLIED, PRIOR TO CARPET INSTALLATION. B. AREAS INDICATED AS RECEIVING VINYL COMPOSITION TILE FLOOR FINISH SHALL HAVE COVED VINYL BASE APPLIED AFTER VINYL COMPOSI1ION TILE INSTALLATION. 6.10 VINYL COMPOSITION TILE INSTALLATION SHALL BE UNI- DIRECTIONAL. SEAMS SHALL BE TIGHT/ INVISIBLE. GC SHALL PROVIDE AND MAINTAIN ADEQUATE PROTECTION FOR ALL NEW INSTALLED VINYL COMPOSITION TILE FOR THE DURATION OF CONSTRUCTION AND REMOVE PROTECTION ONLY IMMEDIATELY BEFORE JOB COMPLETION, FLOOR WILL BE THOROUGHLY CLEANED OF ALL ADHESIVE /CONSTRUCTION STAINS AND RECEIVE APPROPRIATE TWO (2) COATS NON -SUP WAX APPLICATION WHICH IS TO BE THOROUGHLY MACHINE BUFFED TO SATISFACTION OF ARCHITECT. (CLEAN WAX BY G.C.) A. GC TO SUPPLY AND INSTALL VINYL COMPOS111ON TILE AND BASE; CARPET BY OTHERS. (UNLESS OTHERWISE NOTED) 6. GC IS RESPONSIBLE FOR ALL FLASH PATCHING AND TO HAVE FLOOR IN CONDITION TO RECEIVE EITHER CARPET AND /OR VINYL COMPOSITION TILE. 6.11 GC SHALL PROVIDE AND MAINTAIN COMPLETE PROTEC1ON FOR ALL NEW INSTALLED FLOOR FINISHES (INCLUDING CARPET) UNTIL ALL CONSTRUCTION WORK IS COMPLETE. PROTECTION SHALL BE REMOVED ONLY IMMEDIATELY PRIOR TO JOB COMPLETION. 6.12 CARPET SUPPLIER /INSTALLER SHALL PROVIDE CURRENT STOCK SAMPLES OF SPECIFIED CARPET FINISHES FOR APPROVAL PRIOR TO ORDERING. PROVIDE VINYL TRANSITION STRIPS AS SPECIFIED OR NECESSARY (IF NOT SPECIFIED). 6.13 GC, ALL VENDORS /SUBCONTRACTORS ARE RESPONSIBLE FOR FIELD VERIFICATION OF ALL DIMENSIONS, QUANTITIES ETC., OF THEIR RESPECTIVE WORK. 6.14 DRAPERIES AND OTHER WINDOW COVERINGS MUST BE BUILDING STANDARD. G.C. SHALL BE RESPONSIBLE FOR SUPPLY /INSTALLATION AND BUILDING STANDARD WINDOW TREATMENT ,WOOD BLOCKING /GROUNDS ABOVE CEILING AS NECESSARY FOR VERTICAL BLINDS, DRAPERIES, ETC., (UNLESS OTHERWISE NOTED) MILLWORK & CABINETRY NOTES 7.1 DESIGN CRITERIA AS SET FORTH IN SECTIONS 5.1 AND 5.2 SHALL GOVERN DESIGN OF MILLWORK AND CABINETRY. 7.2 SCOPE: ALL FINISHED MILLWORK WOODWORKING, AND CABINETRY INCLUDING WOOD DOORS, JAMBS, FRAMES, WNDOW FRAMES, TRIM, COUNTERS, PANELS, MOLDINGS, CABINET REVEALS, FILE PLATFORMS, BLOCKING AND INSTALLATION OF RELATED HARDWARE IS TO BE COMPLETED BY MILLWORK CONTRACTOR (MC) AS SUBCONTRACTOR TO GC UNLESS OTHERWISE NOTED. 7.3 SCHEDULING AND COORDINATION WTH OTHER TRADES WLL BE THE RESPONSIBILITY OF THE GC WHETHER MILLWORK IS INCLUDED IN HIS WORK OR NOT. 7.4 FURNITURE AS SHOWN ON FURNITURE PLAN IS BY OTHERS. REFER TO FURNITURE PLAN FOR SCOPE OF WORK RELATED TO FURNITURE INSTALLATION (FILE PLATFORMS, REVEALS, ETC.) 7.5 DETAILING OF MILLWORK SHALL BE AS SHOWN. GC SHALL SUBMIT SHOP DRAWNGS AND FINISH SAMPLES FOR REVIEW TO VERIFY CONFORMANCE TO SPECS. 7.6 FIELD MEASUREMENTS SHALL BE VERIFIED BY GC AS REQUIRED. ARCHITECT WILL NOT VERIFY FIELD CONDITIONS AND DIMENSIONS ON SHOP DRAWNGS. 7.7 COORDINATION OF MILLWORK WITH EXISTING AND NEW CONSTRUCTION AND WITH MECHANICAL, FURNITURE AND OTHER RELATED ELEMENTS SHALL BE THE RESPONSIBILITY OF THE GC. 7.8 MATERIALS SHALL BE AS SPECIFIED AND OF HIGHEST QUALITY BY ACCEPTED COMMERCIAL AND INDUSTRY STANDARDS. 7.9 SUITABLE MOISTURE RESISTANT /WATERPROOF SUBSTRATE SHALL BE USED FOR PLASTIC LAMINATE PIECES TO PREVENT FAILURE DUE TO MOISTURE CONDITIONS. 7.10 SUBSTRATE FOR VENEERED AND LAMINATED PANELS SHALL BE FURNITURE GRADE PLYWOOD FOR ALL HORIZONTAL SURFACES AND SHELVES. (HIGH DENSITY PARTICLE BOARD MAY BE USED FOR VERTICAL ELEMENTS.) 7.11 EDGES OF VENEERED PANELS SHALL MATCH SURFACE. EDGES LESS THAN 1" SHALL BE HARDWOOD. 7.12 WOOD VENEERS SHALL BE SINGLE SHEET 1/20' THICK WITH NO SPLICES (EXCEPT AS CALLED FOR). JOINTS AND GRAIN DIRECTION SHALL BE INDICATED ON SHOP DRAWINGS. ADJACENT JOINTED VENEERS SHALL BE BOOK MATCHED UNLESS OTHERWISE NOTED. 7.13 ALL VENEERS SHALL BE STAINED TO MATCH APPROVED FINISH SAMPLE. 7.14 TYPICAL WOOD FINISH SHALL BE SHOP APPLIED DEMI -PORE RUBBED LACQUER. ENTRY DOOR AND FRAME SHALL BE FULL - FILLED RUBBED LACQUER UNLESS OTHERWISE NOTED. ALL WOOD FINISH SHALL INCLUDE: WASH COAT, SAND, STAIN, SEALER (TWO COAT VINYL), TWO COAT TOP -COAT (AN SYSTEM #2). 7.15 FINISH SAMPLES SHALL BE SUBMITTED FOR APPROVAL PRIOR TO FABRICATION AND FINISHING PROCESS. 7.16 PLASTIC LAMINATE SHALL BE SHOP APPLIED ACCORDING TO MANUFACTURERS SPECIFICATIONS. 7.17 PLASTIC LAMINATE SHALL BE ONE SINGLE SHEET ON ANY ONE SURFACE. JOINTS, IF REQUIRED, SHALL BE INDICATED ON SHOP DRAWINGS FOR APPROVAL. ALL JOINTS SHALL BE TIGHT WITH NO SEPARATION. 7.18 WOOD DOOR AND WINDOW FRAMES, ETC., SHALL BE SECURED TO SOLID WOOD GROUNDS /BLOCKING PROVIDED AS PART OF CEILING AND WALL CONSTRUCTION. 7.19 DIMENSIONS FOR WOOD FRAMES SHALL BE FIELD VERIFIED BY GC AFTER RELATED ADJACENT CONSTRUCTION IS COMPLETE. 7.20 WOOD REVEAL FILLERSTRIPS SHALL BE PROVIDED BY GC FOR ALL BUILT -IN CABINETS. FILLERS SHALL BE OF CLOSE GRAINED STOCK, FILLED, SANDED AND PAINTED (SEMI - GLOSS) TO MATCH ADJACENT CONSTRUCTION (EXCEPT AS NOTED). FILLERS SHALL BE INCLUDED FOR ALL BUILT -IN FILES, STORAGE CABINETS, BOOKCASES, ETC. 7.21 INSTALLATION OF REVEAL STRIPS SHALL BE EXECUTED IN A NEAT, WORKMAN LIKE MANNER WITHOUT DAMAGE TO ADJACENT CABINETS OR SURFACES. PIECES SHALL BE SCRIBED TO FIT AND FASTENED TO BLOCKING. 7.22 GLASS PANEL SIZES AND JOINTS (INCLUDING JOINT SEALANT) SHALL BE APPROVED BY ARCHITECT. 7.23 DOOR HARDWARE SHALL BE SUPPLIED AND INSTALLED BY GC. 7.24 HARDWARE WILL BE SPECIFIED BY ARCHITECT. SPECIFICATIONS SHOULD BE THE BETTER OF BUILDING STANDARD OR EQUIVALENT IN QUALITY REFER TO HARDWARE SPECS. 7.25 GC SHALL PROVIDE ALL REQUIRED SIGNAGE AND IDENTIFICATION FOR ALL CABINETS AND EXTINGUISHERS. GENERAL DEMOLITION NOTES: 8.1 REMOVE EXISTING RECEPTACLES, TELEPHONE, SWITCHES, AND ANY ELECTRICAL DEVICES IN WALLS TO BE DEMOLISHED. RELOCATE ANY OF THESE DEVICES AS INDICATED OR REQUIRED BY THE DRAWNGS, ARCHITECT, OR OWNER REPRESENTATIVE. PROVIDE ARCHITECT WITH AS -BUILT OF DRAWINGS OF FINAL INSTALLATION FOR RECORD PURPOSES. CONTRACTOR IS NOTIFIED THAT NOT ALL EXISTING DEVICES MAY HAVE BEEN INDICATED ON THE DRAWINGS AND THAT SOME EXISTING ELECTRICAL DEVICES MAY NOT HAVE BEEN SHOWN IN THEIR ACTUAL LOCATION. CONTRACTOR IS REQUIRED TO VISIT SITE AND BECOME FAMILIAR WTH THE EXISTING CONDITIONS PRIOR TO DETERMINING THE WORK THAT NEEDS TO BE ACCOMPLISHED AS PART OF HIS /HER BID. 8.2 THE WORK SHALL INCLUDE THE FURNISHING OF ALL MATERIALS, CUTTING, EXTENDING, CONNECTING, REPAIRING, ADAPTING, AND OTHER WORKCOINCIOENTAL HERETO. TOGETHER WITH SUCH TEMPORARY INSTALLATIONS AS MAY BE NECESSARY TO SATISFY THE DEMOLITION PROGRAM. APPROVAL SHALL BE SECURED FROM THE LANDLORD/ ARCHITECT PRIOR TO CUTTING/DRILLING ANY STRUCTURAL SUPPORT. 8.3 ALL BUILDING CONSTRUCTION AFFECTED BY THE REMOVAL, RELOCATION, INSTALLATION OF ANY PIECE OF EQUIPMENT SHALL BE REPAIRED AND FINISHED AS REQUIRED TO MATCH EXISTING CONDITION OR AS DIRECTED BY THE ARCHITECTURAL DRAWINGS, SPECIFICATIONS, OR OWNER'S REPRESENTATIVE. 8.4 WHEN ELECTRICAL DEVICES ARE INSTALLED IN PARTITIONS OR CEILINGS TO BE REMOVED, THE ELECTRICAL CONTRACTOR SHALL DISCONNECT THEM UP TO THE NEXT OUTLET TO REMAIN OR BACK TO THE FED THROUGH REMAIN OUTLETS ARE E PANEL BOARD. IF EXISTING TO E DEMOLSHED PARTITIONS OR CEILINGS, THE CIRCUIT SHALL BE REARRANGED TO MAINTAIN CIRCUIT CONTINUITY. WRE SHALL BE REMOVED BACK TO SOURCE FROM INACCESSIBLE RACEWAYS NOT REUSED. INSTALL BLANK PLATES ON FLUSH OUTLETS NOT REUSED. PLATE COLOR SHALL MATCH ADJACENT SURFACE AS NEAR AS POSSIBLE IN FINISHED AREAS. 8.5 ALL ELECTRICAL EQUIPMENT SHALL BE REMOVED FROM STRUCTURE OTHER ELECTRICAL ITEMS ASSOCIATED WITH THIS WORK SHALL BE REMOVED IF NOT REQUIRED FOR NEW EQUIPMENT TO CONTINUE IN SERVICE. 8.6 CONTRACTOR SHALL DEMOLISH ANY INTERIOR FINISHES TO COMPLETE THE NECESSARY AND PROPOSED WORK AS DIRECTED BY THE ARCHITECTURAL DRAWINGS, INTERIOR DESIGN DRAWNGS, SPECIFICATIONS, OR BY OWNER REPRESENTATIVES. B.7 EXISTING FIXTURES, EQUIPMENT, AND ALL DEBRIS WHICH ARE REQUIRED TO BE REMOVED SHALL BE REMOVED BY THE CONTRACTOR. CONTRACTOR TO COORDINATE WTH OWNER REPRESENTATIVES PRIOR TO REMOVAL OF SUCH. 9.8 ALL ELECTRICAL AND PLUMBING LINES WHICH REQUIRE REMOVAL OR ALTERATION ARE TO BE DONE SO BY THE CONTRACTOR. LINES TO BE CAPPED AND PREPARED FOR REMOVAL OR RE- ROUTING AS SPECIFIED 8.9 REMOVE ALL UTILITIES IN DEMOLITION AREAS AND CONSTRUCTION AREAS IN A MANNER, AND IN THE TIME, SATISFACTORY TO THE UTILITY COMPANY. IF UTILITY COMPANY DESIRES TO EFFECT THE REMOVAL OF THE MATERIALS, THEY SHALL BE PERMITTED TO DO SO. 8.10 COVER ITEMS AS SPECIFIED BY OWNER /OWNER REPRESENTATIVE TO PROTECT FROM DUST AND DEBRIS. B.11 SALVAGED MATERIALS SHALL BE REMOVED, CLEANED, AND PREPARED FOR RE- INSTALLATION. OWNER MAINTAINS OWNERSHIP OF ALL MATERIALS UNLESS OTHERWSE SPECIFIED. 8.12 WHERE EXISTING WALLS, CEILINGS, AND FIXTURES HAVE BEEN REMOVED, AREAS SHALL BE PATCHED TO MATCH EXISTING FINISHES, OR FINISHES TO BE ADDED AS PER PLANS, INTERIOR DESIGNER, OR AS PER OWNER 8.13 WHERE EXISTING ACOUSTICAL CEILING PANELS ARE TO BE REMOVED, MATERIALS SHALL BE REMOVED IN A MANNER ACCEPTABLE TO BUILDING ARCHITECT /OWNER. CONTRACTOR SHALL COORDINATE STORAGE AND /OR DISPOSAL OF SOLID MATERIALS WITH BUILDING OWNER /REPRESENTATIVE. B.14 WHERE EXISTING WORK IS DAMAGED IN THE EXECUTION OF THIS CONTRACT, OR WHERE OPENINGS ARE LEFT DUE TO THE REMOVAL OF PIPES, EQUIPMENT OR APPARATUS, THE SAME SHALL BE REPAIRED OR CLOSED UP TO CORRESPOND IN MATERIAL, QUALITY, SHAPE AND FINISH WITH THAT OF SIMILAR AND ADJOINING WORK, UNLESS OTHERWISE CALLED FOR. WHERE DAMAGE IS UNREPAIRABLE, NEW ITEMS OR EQUIPMENT SHALL BE PROVIDED. CONTRACTOR SHALL PROVIDE ALL NECESSARY WATERPROOFING, FIRE STOPPING AND SEALING OF PENETRATIONS LEFT FROM REMOVED EQUIPMENT OR PRODUCED BY THIS WORK. 8.15 INTERRUPTION OF EXISTING SERVICES AND /OR OPERATION OF FACILITIES SHALL BE KEPT TO A MINIMUM. CONTRACTOR SHALL FURNISH ALL MATERIALS REQUIRED WHENEVER TEMPORARY CONNECTIONS ARE NECESSARY TO MAINTAIN CONTINUITY OF SERVICE. INTERRUPTION OF EXISTING SERVICES, THE INSTALLATION OF TEMPORARY FACILITIES, AND THE WORK OF MAKING FINAL CONNECTIONS TO THE NEW WORK SHALL BE DONE ONLY AT SUCH TIMES PERMITTED AND SCHEDULED IN ADVANCE BY THE ARCHITECT /OWNER WITHOUT ADDITIONAL COST. CARE MUST BE USED IN REMOVING SERVICES TO AREAS BEING DEMOLISHED SO THAT SERVICES TO OTHER AREAS WHICH MIGHT BE SERVED THROUGH THESE AREAS WILL NOT BE INTERRUPTED. 8.16 WHERE DEMOLITION WORK REQUIRES TEMPORARY INTERRUPTION OF ELECTRICAL, TELEPHONE, TV, ALARM OR COMMUNICATION SERVICES, RESPECTIVE UTILITIES AND /OR COMPANY REPRESENTATIVES SHALL BE NOTIFIED AS NECESSARY, AND ALL WORK DONE SHALL BE UNDER SUPERVISION AND THEIR ESTABLISHED STANDARDS. 8.17 ALL LIGHTING FIXTURES, RECEPTACLES, SWTCHES, WRING DEVICES, SPECIAL OUTLETS, TELEPHONE CABLES, TV CABLES, MISCELLANEOUS SYSTEM WRING, POWER CONDUCTORS, CONDUITS, ELECTRICAL BOXES, RACEWAYS AND ANY OTHER ELECTRICAL SYSTEM COMPONENTS LOCATED IN THE AREAS SHOWN AS BEING DEMOLISHED OR NOT USED AFTER WORK IS COMPLETED SHALL BE REMOVED UNLESS OTHERWISE NOTED AS EXISTING TO REMAIN OR BE RELOCATED. CONDUITS RUNNING IN SLAB AT FINISHED AREAS SHALL BE CUT FLUSH, PLUGGED AND ABANDONED AFTER CONDUCTORS ARE REMOVED. NO WRING SHALL BE LEFT ABANDONED AFTER WORK IS COMPLETED. - - y. I; :,I - - G. %) 5 TUl4itl;(L C `,. >:; ESIZiN C1, ��3 -- :::. _ - � _ ... , :. r! _�rfa : r:t.:::: -, 15.1 JEVFLLA A�1ENUE; S_JITE 2GG - - " r r.: ::., . .. RATIVE CORAL GABLES, FL 33134 OFFICE: (305) 442 -1188 Client Name T (� , FAX: (305) 445 -1509 ') a4 . t' . WWW. ADCINTERNATIONAL.NET 1696 NE MIAMI GARDENS DR 0 Ir �° . ` SUITE 8 Scale N. MIAMI BEACH, FL 33179 y ' (305) 947 -8800 Ys, . -(- , yC t ( t Vk .��y , ' ) L. STATE OF FLORIDA '' "AR- 0010536 RAYMUNDO FEITO, R.A. AA- CO01315 Architect • Seal/Signature ............ ............................... ........... ............................... ................... MRA E XPANSION SUNSET PROFESSIONAL BLDG 6280 SUNSET DR SUITE 600 SOUTH MIAMI FL Date Issue Description Drawn By Checked By 04 -13 -09 LANDLORD REVIEW ER ER .............................................................. ............................... . 04 -27 -09 PERMIT ISSUE ER ER Project Number Client Name 09032 PROMED PROPERTIES Description Client Address 1696 NE MIAMI GARDENS DR SUITE 8 Scale N. MIAMI BEACH, FL 33179 Client Phone Number (305) 947 -8800 CAD File Name GENERAL NOTES ot)V m1p,ml Consultant • Seal/Signature Cps( of o14o j)SPT. au► 00r 0AG SeCT100 ,,aPRCNE1D� -D 2 - A O. 2 3 OF 15 r