GENERAL NOTES & CONDITIONS
SPECIFICATIONS FOR GENERAL CONTRACTORS PERFORMING WORK
FOR PALMETTO BAY VILLAGE CENTER
1.1 UPON COMPLETION OF THE JOB, THE CONTRACTOR
PROVIDE THE TENANT AND LANDLORD WITH:
A. AS -BUILT PLANS.
B. RELEASE OF LIENS FOR ALL SUB - CONTRACTORS.
C. A FINAL RELEASE OF LIENS FROM THE GENERAL
CONTRACTOR.
D. THE ORIGINAL BUILDING PERMIT PLANS WITH THE ORIGINAL
INSPECTOR'S SIGNATURES.
1.2 THE LANDLORD WILL NOT BE RESPONSIBLE FOR:
A. SECURITY OF MATERIALS OF WORK IN PLACE.
B. AIR CONDITIONING WORK NOT BEING PROPERLY
PERFORMED TO ALLOW FOR PROPER COOLING OF THE
LEASED PREMISES UNLESS ALL AIR CONDITIONING WORK
IS DONE IN COORDINATION WITH THE BUILDING
ENGINEERING STAFF.
C. WARRANTY REPAIRS.
D. WINDOW BREAKAGE DURING CONSTRUCTION.
E. WORK STOPPAGES DUE TO WORK INTERFERING WITH
OTHER TENANTS.
F. DELAYS DUE TO CHANGE ORDERS AND
ARCHITECT - CONTRACTOR PROBLEMS.
G. PAYMENT OF ANY DRAW WILL BE SUBJECT TO THE
LANDLORD'S AND OWNER'S REPRESENTATIVES AGREEING
TO THE DEGREE OF COMPLETION, TEN PERCENT (10%)
OF EACH DRAW WILL BE HELD AS A RETAINER UNTIL
THE JOB IS COMPLETED, INCLUDING PUNCH LIST ITEMS,
RELEASES OF LIEN, AND ACCEPTANCE OF THE SPACE
BY BOTH THE TENANT AND LANDLORD.
1.3 THE CONTRACTOR WILL:
SECURE THE NECESSARY BUILDING PERMITS AND INSPECTIONS.
INDEMNIFY AND KEEP HARMLESS THE OWNER FROM ALL
LOSSES, DAMAGES, LIABILITIES, AND EXPENSES WHICH MAY
ARISE OR BE CLAIMED AGAINST LANDLORD AND BE IN FAVOR
OF ANY PERSONS, FIRMS, OR CORPORATIONS FOR ANY
INJURIES OR DAMAGES TO THE PERSON OR PROPERTY OF
ANY PERSONS, FIRMS, OR CORPORATION CONSEQUENT UPON
OR ARISING FROM THE CONSTRUCTION, USE, OR OCCUPANCY
OF LEASED PREMISES BY THE CONTRACTOR OR CONSEQUENT
UPON OR ARISING FROM ANY ACTS, OMISSIONS, NEGLECT OR
FAULT OF THE CONTRACTOR , HIS AGENTS, SERVANTS,
EMPLOYEES, LICENSEES, VISITORS, CUSTOMERS, PATRONS,
OR INVITEES, OR CONSEQUENT UPON OR ARISING FROM THE
CONTRACTOR'S FAILURE TO COMPLY WITH ANY LAWS,
STATUTES, ORDINANCES, CODES, OR REGULATIONS; THAT THE
OWNERS SHALL NOT BE LIABLE TO THE CONTRACTOR FOR
DAMAGES, LOSSES OR INJURIES TO THE PERSONS, FIRMS
OR CORPORATIONS EXCEPT WHEN SUCH INJURY, LOSS, OR
DAMAGE RESULTS FROM NEGLIGENCE OF THE OWNER,
HIS AGENTS, OR EMPLOYEES, AND THAT THE CONTRACTOR
WILL IDEMNIFY AND KEEP HARMLESS THE OWNERS AND
BE IN FAVOR OF ANY PERSONS, FIRMS, OR CORPORATIONS FOR
ANY INJURIES OR DAMAGES TO THE PERSON, OR THE PROPERTY
OF ANY PERSONS, FIRMS OR CORPORATIONS WHERE SAID
INJURIES OR DAMAGES AROSE ABOUT OR UPON THE LEASED
PREMISES AS A RESULT OF THE HE NEGLIGENCE OF THE
CONTRACTOR, HIS AGENTS, EMPLOYEES,SERVANTS, LICENSEES,
VISITORS, CUSTOMERS, PATRONS, AND INVITEES. ALL
PERSONAL PROPERTY PLACED OR MOVED INTO OR OUT OF
THE BUILDING SHALL BE AT THE RISK OF THE CONTRACTOR
OR THE OWNER THEREFORE AND THE OWNERS SHALL NOT
BE LIABLE TO THE CONTRACTOR FOR ANY DAMAGE
TO ANY PERSONAL PROPERTY.
1.4 THE CONTRACTOR WILL CONFINE THE CONSTRUCTION DEBRIS
AND DUST TO THE CONSTRUCTION AREA, AWAY FROM
COMPLETED TENANT SPACE OR COMMON AREAS, ALL AREAS
OF THE BUILDING, ESPECIALLY ACCESS AREAS AND COMMON
AREAS, ARE TO BE MAINTAINED IN A CLEAN AND ORDERLY
FASHION. THE CONTRACTOR IS TO TURN THE IMPROVED
PREMISES OVER THE PROPERTY MANAGER IN A CLEAN
CONDITION, READY FOR OCCUPANCY BY THE TENANT.
1.5 THE CONTRACTOR WILL REMOVE ALL TRASH AND DEBRIS,
INCLUDING EXCESS MATERIALS FROM THE CONSTRUCTION SITE
AND THE BUILDING AND NO UNREASONABLE ACCUMULATION
BE ALLOWED.
1.6 THE CONTRACTOR WILL COORDINATE THE DELIVERY OF
MATERIALS AND THE USE OF THE FREIGHT ELEVATOR AND
REMOVAL OF DEBRIS WITH THE PROPERTY MANAGER
1.7 THE CONTRACTOR IS RESPONSIBLE FOR ALL PARKING
CHARGES OF HIS EMPLOYEES, SUB- CONTRACTORS, AND
VENDORS.
1.8 THE CONTRACTOR WILL SUBMIT ALL CHANGES ORDERS TO
THE CLIENT FOR APPROVAL AND THE DRAWINGS ARE
TO BE REVISED ACCORDINGLY.
1.9 THE CONTRACTOR WILL EXERCISE ALL DUE DILIGENCE IN
MAINTAINING IN A SAFE WORKING ENVIRONMENT AND TO
ABIDE BY ALL OSHA REGULATIONS.
1.10 UPON COMPLETION, THE CONTRACTOR WILL REMOVE ALL
FOREIGN MATERIALS FROM WINDOWS, FLOORS, GLASS,
HARDWARE AND RESTROOM FIXTURES.
1.11 THE CONTRACTOR WILL NOT UNDULY DISTURB THE PEACEFUL
ENJOYMENT OF ANY TENANTS IN THE BUILDING.
ALL DRILLING THROUGH THE CONCRETE FLOOR SLAB IS TO BE
SCHEDULED WITH THE PROPERTY MANAGER. ALL PLUMBING
INSTALLATIONS REQUIRING ACCESS TO OTHER AREAS OF THE
BUILDING WET COLUMN WILL BE COORDINATED WITH THE
PROPERTY MANAGER.
1.12 THE CONTRACTOR WILL INSTALL CONSTRUCTION AIR
CONDITIONING FILTERS IN ALL RETURN AIR DAMPERS IN
THE DEMISING WALLS IN ORDER TO PREVENT CONSTRUCTION
DUST FROM ENTERING THE MAIN AIR CONDITIONING SYSTEM.
1.13 THE CONTRACTOR IS TO PROVIDE FIVE (5) COPIES OF ALL
SHOP DRAWINGS, PRODUCT INFORMATION SUBMITTALS, AND
ALL OTHER SUBMITTALS REQUIRED FOR REVIEW, ETC. AT
LEAST TWO (2) OF THE ABOVE COPIES SHALL BE ORIGINALS.
1.14 THE CONTRACTOR SHALL VISIT THE JOB SITE AND VERIFY
ALL CONDITIONS OF THE WORK PRIOR TO SUBMITTING A BID.
1.15 THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE
FIELD. DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT
PRIOR TO THE COMMENCING OF THE WORK IN THE AREA
IN QUESTION.
1.16 ALL WORK SHALL BE DONE IN ACCORDANCE TO THE LATEST
EDITION OF THE FLORIDA BUILDING CODE 2001 EDITION AND ANY
APLICABLE CODE.
1.17 IMPACT FEES, WATER AND SEWER CONNECTION FEES AND
DEPOSITS FOR PERMANENT UTILITY SERVICES SHALL BE PAID
FOR THE BY OWNER. THE CONTRACTOR SHALL NOTIFY THE
ARCHITECT AND /OR THE OWNER WHEN THESE FEES APPLY
PRIOR TO THE START OF THE CONSTRUCTION OF THIS
PROJECT.
1.18 THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR ALL
PREFABRICATED ITEMS OF THE WORK INCLUDING BUT NOT
LIMITED TO THE FOLLOWING PREFAB STAIR, WHEELCHAIR LIFT,
STOREFRONT DOORS, CABINETS, AIR
CONDITIONING, ETC. THE CONTRACTOR SHALL OBTAIN THE
ARCHITECT'S WRITTEN APPROVAL OF SHOP DRAWINGS PRIOR
TO THEIR FABRICATION. SAMPLES SHALL BE SUBMITTED
UPON REQUEST.
1.19 WHERE EXISTING WALLS, CEILINGS OR FIXTURES ARE
REMOVED: WALLS CEILINGS AND FLOORS SHALL BE PATCHED;
ELECTRIC AND PLUMBING SHALL BE CAPPED.
1.20 PROVIDE 1 -3 ABC RATED FIRE EXTINGUISHER PER 2500
SQ. FT., AND MAXIMUM INTERVALS OF 75' -0". FIRE
EXTINGUISHER SHALL BE BLDG. STANDARD, RECESSED TYPE
CONTRACTOR SHALL VERIFY.
GENERAL NOTES (CONT.
1.21 ANY ITEM OF WORK NECESSARY TO THE PROPER
COMPLETION OF CONSTRUCTION WHICH IS NOT
SPECIFICALLY COVERED IN THESE DOCUMENTS SHALL
BE PERFORMED IN A MATTERS DEEMED GOOD
PRACTICE OF THE TRADE INVOLVED.
1.22 ALL NEWS MATERIALS AND FINISHES SHALL MATCH
EXISTING UNLESS SPECIFIED OTHERWISE, SEE OWNER
AND /OR ARCHITECT FOR APPROVAL OF ALTERNATIVES.
1.23 BUILDING HAS A COMPLETE FIRE SPRINKLER SYSTEM.
SUBMIT SHOP DRAWINGS FOR THE RELOCATION AND
CONDITION OF SPRINKLER HEADS.SPRINKLER HEADS
SHALL MATCH EXISTING.
1.24 NOT USED
1.25 CONTRACTOR SHALL PREPARE EXISTING AND NEW FLOOR
SURFACES FOR PROPER LEVELING TO RECEIVE NEW
NEW PROPOSED FLOOR FINISHES.
1.26 CONTRACTOR IS TO PROVIDE PROPER BACKING AND
BRACING AT ALL AREAS TO RECEIVE MILLWORK
CABINETS, SHELVING, ETC.
1.27 ALL PROPOSED MILLWORK CONSTRUCTION SHALL
COMPLY WTH AN CUSTOM STANDARDS, TYP.
1.28 CONTRACTOR SHALL COORDINATE AT ROUGH FRAMING
PRIOR TO INSTALLATION OF GYPSUM WALL BOARD ALL
PROPOSED CONDUIT TYPES RUNS AND LOCATIONS W/
LOW VOLTAGE VENDOR. TYP.
1.29 USE AND INTERPRETATION OF THIS DRAWING
A. GENERAL CONDITIONS OF THE CONTRACT FOR
CONSTRUCTION, AIA DOCUMENT A201, ARE A PART OF
A CONTRACT DOCUMENT AS DESCRIBE USE AND
INTENT OF THE DRAWINGS. THE CONTRACT DOCUMENTS
INCLUDE NOT ONLY THE DRAWINGS, BUT ALSO THE
OWNER - CONTRACTOR AGREEMENT, CONDITIONS OF THE
CONTRACT, THE SPECIFICATIONS, ADDENDA, AND
MODIFICATIONS ISSUED AFTER EXECUTION OF THE
CONTRACT. THESE CONTRACT DOCUMENTS ARE
COMPLEMENTARY, AND WHAT IS REQUIRED BY ANY
ONE SHALL BE BINDING AS IF REQUIRED BY ALL.
WORK NOT COMPLETELY DELINEATED HEREON SHALL
BE CONSTRUCTED OF THE SAME MATERIALS
AND DETAILED SIMILARLY AS WORK SHOWN MORE
COMPLETELY ELSEWHERE IN THE CONTRACT
DOCUMENTS.
B. BY USE OF THE DRAWINGS FOR CONSTRUCTION OF THE
PROJECT THE OWNER REPRESENTS THAT HE HAS
REVIEWED AND APPROVED THE DRAWNGS, AND THAT
THE CONSTRUCTION DOCUMENT PHASE OF THE PROJECT
IS COMPLETE. THE CONTRACTOR REPRESENTS THAT
HE HAS VISITED THE SITE, FAMILIARIZED HIMSELF
WITH THE LOCAL CONDITIONS, VERIFIED FIELD
DIMENSIONS AND CORRELATED HIS OBSERVATIONS WITH
THE REQUIREMENTS OF THE CONTRACT DOCUMENTS.
C. THE CONTRACT SUM AND THE CONTRACT TIME MAY BE
CHANGED ONLY BY CHANGE ORDER TO THE
CONTRACTOR SIGNED BY THE OWNER AND THE
ARCHITECT. ANY WORK PERFORMED IN VARIANCE WITH
THE CONTRACT DOCUMENTS AND NOT COVERED BY
THE ARCHITECT'S WRITTEN ORDER FOR A MINOR
CHANGE IN THE WORK OR A CHANGE ORDER, WILL
NOT BE ACCEPTED.
D. AS INSTRUMENTS OF SERVICE, ALL DRAWINGS,
SPECIFICATIONS AND COPIES THEREOF FURNISHED BY
THE ARCHITECT ARE HIS SPECIFICATIONS AND
PROPERTY. THEY ARE TO BE USED ONLY FOR THIS
PROJECT AND ARE NOT TO BE USED ON ANY OTHER
PROJECT. CHANGES TO THE DRAWINGS NOT TO BE
USED ON ANY OTHER PROJECT. CHANGES TO THE
DRAWINGS MAY ONLY BE MADE BY THE ARCHITECT.
ANY SUBMISSION OR DISTRIBUTION WITHOUT THE
EXPRESS WRITTEN CONSENT OF THE ARCHITECT
MAY BE CONSTRUED AS DEROGATION OF THE
ARCHITECT COPYRIGHT OR OTHER RESERVED RIGHTS.
1.30 ALL WORK SHALL BE CONSTRUCTED IN ACCORDANCE
WITH ADA ACCESSIBIUTY GUIDELINES AS SET FORTH IN
THE AMERICANS WTH DISABILITIES ACT HANDBOOK.
AS PUBLISHED BY THE EQUAL OPPORTUNITY
COMMISSION AND THE U.S. DEPARTMENT OF JUSTICE ON
OCTOBER 1991. THE CONTRACTOR AND
SUBCONTRACTORS SHALL BE RESPONSIBLE FOR
THE IMPLEMENTATION OF SUCH.
CONSTRUCTION PLAN NOTES
2.1 PRIOR TO START OF CONSTRUCTION, GC SHALL
COORDINATE SCHEDULING OF MEETING WITH HIS
PROJECT PERSONNEL, THE BUILDING /LANDLORD
REP(S), ARCHITECT PROJECT MANAGER, OTHERS, FOR
REVIEW OF PROJECT SCOPE, DESIGN INTENT,
CONSTRUCTION QUALITY EXPECTED, & FINAL
DISCUSSION OF DRAWINGS /DETAILS /QUESTIONS.
2.2 DIMENSIONS ON DRAWINGS ARE FINISH FACE TO
FINISH FACE OF PARTITIONS, COLUMNS, ETC., OR TO
WHERE SHOWN, UNLESS OTHERWISE NOTED.
DO NOT SCALE DRAWINGS
WRITTEN DIMENSIONS TAKE PRECEDENCE OVER
GRAPHIC REPRESENTATION. DETAIL DIMENSIONS
TAKE PRECEDENCE OVER PLAN DIMENSION.
2.3 GC SHALL BE RESPONSIBLE FOR FIELD MEASURING
OF EXISTING CONDITIONS PRIOR TO START OF WORK
AND DURING CONSTRUCTION, AS NECESSARY, TO
ASSURE CONSTRUCTION ADHERENCE TO
DRAWINGS. BY ENTERING INTO A CONSTRUCTION
CONTRACT FOR THIS WORK, GC SHALL INDICATE HIS
FAMILIARITY WTH THE SITE /FIELD, CONDITIONS.
A. ALL 'HOLD' DIMENSIONS SHALL BE MONITORED
TO ASSURE CORRECTNESS.
B. ANY DIMENSION REVISIONS /MODIFICATIONS ARE
TO BE BROUGHT TO ATTENTION OF ARCHITECT
PROJECT MANAGER FOR REVIEW /APPROVAL.
2.4 ALL VERTICAL DIMENSIONS SHALL BE TAKEN FROM
"BENCH MARK" OR OTHER SIMILAR GUIDE ESTABLISHED
PRIOR TO START OF CONSTRUCTION. HIGH POINTS,
LOW POINTS IRREGULARITIES IN FLOOR LOOR SLAB,
PARTICULARLY, WHICH COULD IN ANY WAY AFFECT
FABRICATION /INSTALLATION WORK OF OTHER TRADES
OR VENDORS (E.G., CABINET CONTRACTORS), SHALL
BE BROUGHT TO ATTENTION OF ARCHITECT.
A. VARIATIONS IN FLOOR LEVEL IN EXCESS OF 1/2"
FOR EVERY 10' -0" IN EVERY DIRECTION WILL
REQUIRED LEVELING OF SLAB BY G.C. OR LANDLORD
AS PREDICATED BY FINAL LEASE AGREEMENT.
LEVELING OF SLAB TO BE DONE READY TO RECEIVE
ARCHITECT FLOOR FINISHES, I.E. VINYL TILE FLOORS,
CARPETING, ETC. GENERAL CONTRACTORS TO VERIFY
SLAB CONDITION PRIOR TO BID SUBMISSION.
2.5 GC SHALL DEMOLISH EXISTING PARTITION AND
VARIOUS OTHER ELEMENTS AS INDICATED ON PLAN
AND COORDINATE THE REMOVAL OF ALL RELATED
ELECTRICAL SERVICE, PLUMBING AND ALL OTHER
APPURTENANCES INCLUDED THEREIN, REFER TO GENERAL
DEMOLITION NOTES.
2.6 GC SHALL BE RESPONSIBLE FOR THE REMOVAL OF
ALL CONSTRUCTION DEBRIS AND FOR THE RETURN
OF ANY BUILDING STANDARD COMPONENTS IF
REQUESTED BY THE BUILDING MANAGEMENT
UNLESS OTHERWISE NOTED ON C'D'S
CONSTRUCTION PLAN NOTES(CONT)
2.7 ALL EXISTING DOORS DESIGNATED FOR REMOVAL,
INCLUDING FRAMES, SHALL BE REUSED WHERE
SAME TYPE DOOR IS APPLICABLE AND /OR IS CALLED
FOR IN NEW DESIGN WHENEVER POSSIBLE. ALL
EXISTING HARDWARE SHALL BE RETAINED FOR
REUSE: COORDINATE WITH ARCHITECT PROJECT MANAGER
UNLESS OTHERWISE NOTED ON C'D'S
2.8 ALL CONVENTIONAL DRYWALL CONSTRUCTION,
FURRING, SHEATHING, THIS CONTRACT, SHALL BE
AS DETAILED (REFER TO LEGEND ENTRIES, ON
CONSTRUCTION PLAN). DRYWALL JOINTS SHALL BE
TAPED /SPACKLED LEVEL. EXTERIOR CORNERS
SHALL RECEIVE METAL CORNER REINFORCING BEAD
AND BE SPACKLED IN CONVENTIONAL MANNER. NO
HORIZONTAL DRYWALL JOINTS SHALL BE ACCEPTED
UNLESS APPROVED BY ARCHITECT. BUTTED, UNTAPED
DRYWALL JOINTS ARE NOT ACCEPTABLE. FULL
HEIGHT GYPSUM BOARD SHEETS SHALL BE USED
THROUGHOUT FOR FULL HEIGHT CONSTRUCTION.
A. ALL NEW DRYWALL CONSTRUCTION SHALL BE
PROPERLY PREPARED TO RECEIVE SPECIFIED
FINISH MATERIAL(S) IN MANNER FULLY
ACCEPTABLE TO ARCHITECT.
B. TAPED JOINTS, CORNERS, 'DIMPLES' OR SCREW
HEADS SHALL BE SPACKLED SMOOTH AND
GYPSUM LEVEL WITH ADJACEN T G SU M BOARD
SURFACE. NO BULGING OR UNEVEN FINISHED
DRYWALL WILL BE ACCEPTED.
2.9 ALL EXISTING HOLES /CRACKS IN SLAB AND THOSE
RESULTING FROM THE CONSTRUCTION PROCESS
SHALL BE FILLED /REPAIRED AND THE SURFACE
PATCHED SMOOTH AND LEVEL WTH ADJACENT
FLOOR SURFACE, IN A MANNER ACCEPTABLE TO
THE ARCHITECT.
2.10 ALL NECESSARY WOOD BLOCKING /GROUNDS, ETC.,
ARE TO BE SUPPLIED AS FACTORY TREATED FIRE-
PROOFED ELEMENTS. GC SHALL FULLY COORDINATE
SETTING /PLACEMENT OF THESE ELEMENTS AS REQ'D
BY LOCAL CODE /BUILDING OR SURROUNDING
CONSTRUCTION CONDITIONS.
A. GROUNDS /BLOCKING MAY NOT BE WHOLLY SHOWN
ON DRAWNGS AND GOOD CONSTRUCTION
PRACTICE SHALL GOVERN/ DETERMINE SAID
USE WHERE A QUESTION ARISES.
B. GC TO PAY PARTICULAR ATTENTION TO ALL
LOCATIONS OF DRYWALL PARTITION
CONSTRUCTION THAT ABUT OR RECEIVE
MILLWORK OR CABINETWORK CONSTRUCTION.
INTERNAL WOOD BLOCKING SHALL BE
SUPPLIED FOR STURDY ANCHORAGE AT
INTERSECTIONS OF WOOD /GLASS BORROWED
LIGHT PARTITIONS AND ADJACENT DRYWALL
CONSTRUCTION, AS REQUIRED.
C. BLOCKING FOR ALL MILLWORK INSTALLATIONS,
BUILT -IN FURNITURE, DRAPERY TRACKS AND
PRESENTATION BOARDS SHALL BE PROVIDED
BY GC. REFER TO FURNITURE PLAN
AND FINISH PLAN FOR COMPLETE SCOPE.
REFER TO MECHANICAL PLAN FOR BLOCK
REQUIREMENTS FOR WALL MOUNTED HVAC
EQUIPMENT IN TELEPHONE EQUIPMENT ROOM.
2.11 GC SHALL PROVIDE GENERAL CARPENTRY AS
REQUIRED FOR WORK WHICH MAY NOT FALL INTO
JURISDICTION OF A SPECIFIC TRADE, BUT IS
REQUIRED FOR PROPER JOB EXECUTION AND
COMPLETION OF CONSTRUCTION.
2.12 INSTALL ALL PLUMBING NECESSARY FOR THE
INDICATED PLUMBING FIXTURES /APPURTENANCES.
SAID UNITS SHALL BE AS SPECIFIED. (REFER TO
MECHANICAL PLANS.)
2.13 ANY ACCESS PANELS REQUIRED IN ANY
CONSTRUCTION THIS CONTRACT SHALL BE
APPROVED AS TO SPECIFIC SIZE, LOCATION, FINISH,
ETC., BY ARCHITECT.
2.14 GC, SUBCONTRACTORS, AND ALL VENDORS ARE TO
VERIFY ALL CLEARANCES (CORRIDORS, STAIRS,
ELEVATORS, ETC.) REQUIRED FOR DELIVERIES,
PASSAGE OF ALL JOB MATERIALS /EQUIPMENT.
A. GC SHALL SCHEDULE FOR AND INCLUDE COSTS/
FEES NECESSARY FOR USE OF BUILDING ELEVATOR
OR ANY SPECIAL CARTAGE, RIGGING, HOISTING,
DELIVERIES, TRANSPORTATION, ETC. CONNECTED
WITH CONTRACT WORK.
B. GC SHALL COORDINATE CLOSELY WTH VARIOUS
ARCHITECT VENDORS OR CONTRACTORS, REGARDING
INFORMATION IN PART "A" THIS NOTE ABOVE
REFLECTED CEILING/ MECH.
SYST.NOTES CONT.
3.11 HVAC SUPPLY, RETURN, EXHAUST GRILLES SHALL
BE AS SPECIFIED IN MECHANICAL DRAWINGS OR
"BUILDING STANDARD" IF NOT SPECIFIED. GC TO
VERIFY CONFORMANCE OF SPEC WITH BUILDING
STANDARDS. ALL HVAC ELEMENTS SHALL BE
OFF -WHITE (TO MATCH CEILING) INSTALLED FLUSH
AND TRUE AND CENTERED WITHIN THE CEILING
GRID. LOCATIONS SHALL BE PER APPROVED
MECHANICAL PLANS,UNLESS OTHERWISE NOTED ON CD'S..
3.12 ARCHITECTURAL CEILING PLAN SHALL
GOVERN WTH RESPECT TO LOCATIONS FOR
CEILING PENETRATIONS AS AESTHETIC AND
FUNCTIONAL CONSIDERATIONS DICTATE.
MECHANICAL DOCUMENTS SHALL TAKE
PRECEDENCE WTH RESPECT TO OVERALL SCOPE
OF WORK.
3.13 DUCTWORK, WHEN CONTINUOUS THROUGH MORE
THAN ONE ROOM, SHALL BE ACOUSTICALLY LINED
TO DIMINISH SOUND TRANSMISSION THROUGH
DUCTS.
3.14 CLEARANCES FOR ALL RELATED CEILING PLENUM
THAN ONE ROOM, SHALL BE ACOUSTICALLY LINED
NO ADDITIONAL COST.
3.15 SPECIAL COOLING REQUI REM ENTS/SUPPLEN MENTAL SYSTEM
SHALL BE DESIGNED AND SPECIFIED IN THE MECHANICAL
CD'S CO NTRACTOR SHALL COORDINATE ABOVE CEILING
CONDITIONS FOR THIS INSTALLATION.
3.16 NOT USED
3.17 FIRE PROTECTION SYSTEMS AS SPECIFIED OR
REQUIRED BY CODE, SHALL BE PROVIDED BY GC.
MINIMUM SPRINKLER INSTALLATION MUST MEET
REQUIREMENTS OF NFPA 13.
3.18 SPRINKLER HEAD LOCATION SHALL BE COORDINATED
WTH OTHER TRADES BY GC AND SHALL BE AS
SPECIFIED BY ENGINEER OR AS REQ'D BY CODE.
SPRINKLERS SHALL BE CENTERED WTHIN EACH CEILING
TILE TO PROVIDE A UNIFIED, CONSISTENT AND AESTHETIC
ARRANGEMENT. HEADS SHALL BE WHITE FLUSH TYPE
OR BUILDING STANDARD IF EQUAL OR BETTER.
3.19 LIGHTING FIXTURES, EXIT LIGHTS, SWITCHING, ETC.
SHALL BE PROVIDED BY GC. ARCHITECTURAL PLAN
SHALL GOVERN LOCATION, ENGINEERING PLANS SHALL
PREVAIL IN QUESTIONS OF CIRCUITING AND SCOPE.
3.20 CUT SHEETS FOR ALL FIXTURES SHALL BE
SUBMITTED ARCHITECT SB BY GC FOR REVIEW /APPROVAL.
SUBSTITUTIONS MUST BE APPROVED BY ARCHITECT.
3.21 EMERGENCY LIGHTING AND ANNUNCIATOR / ALARM
SYSTEMS SHALL BE SPECIFIED BY ENGINEER.
3.22 NEW SWITCHES SHALL MATCH EXISTING TYPE USED
WHERE EXISTING SWITCHES ARE TO REMAIN.
3.23 ELECTRICAL WORK SHALL BE PERFORMED IN
ACCORDANCE WITH THE LATEST "NATIONAL
ELECTRICAL CODE' AND ANY AND ALL APPLICABLE
STATE AND LOCAL CODES /ORDINANCES.
3.24 CLEANING: BEFORE JOB COMPLETION, THE FOLLOWING
SHALL BE SATISFIED:
A. ALL LIGHT FIXTURE INTERIORS AND LENSES SHALL
BE WIPED CLEAN OF ALL CONSTRUCTION DUST,
GRIME, FINGERMARKS, ETC., AND BE FULLY
FUNCTIONING, MECHANICALLY AND ELECTRICALLY.
B. ALL LAMPING WILL BE NEW AND FUNCTIONAL.
C. RECESSED INCANDESCENT FIXTURES SHALL BE
SIMILARLY CLEANED AND BE FUNCTIONAL AND
SHALL BE AIMED, IF CALLED FOR, PER REFLECTED
CEILING PLAN.
3.25 PROTECTION: ALL ELECTRICAL ELEMENTS, WHEN
INSTALLED, SHALL BE PROTECTED FROM DAMAGE BY
OTHER TRADES. COVER PLATES SHALL BE
INSTALLED AFTER FINISH MATERIALS HAVE BEEN APPLIED.
3.26 MAINTENANCE CONTRACT FOR SUPPLEMENTAL AIR
CONDITIONING SYSTEMS INSTALLED UNDER THIS
CONTRACT SHALL BE SUBMITTED TO ARCHITECT BY MECH
CONTRACTOR FOR REVIEW. SERVICES TO BE
INCLUDED SHALL BE AS RECOMMENDED BY
MANUFACTURER. CONTRACT TO BE ONE -YEAR
TERM, RENEWABLE FOR ONE YEAR.
3.27 WARRANTIES FOR SUPPLEMENTAL COOLING
EQUIPMENT SHALL BE EXTENDED TO 5 YEARS
ON COMPRESSORS AND WHERE UNITS INCLUDE
A PACKAGED SEALED HERMETIC REFRIGERANT
SYSTEM, SHALL COVER THE ENTIRE SYSTEM.
2.15 EXISTING GYPSUM BOARD IN, ANY AREA OF
Client Name
T (� ,
THIS PROJECT (TO INCLUDE CORE AND PERIMETER
') a4
. t' .
COLUMNS AND WALLS) SHALL BE PATCHED,
1696 NE MIAMI GARDENS DR
ELECTRICAL PLAN NOTES
SPACKLED, AS REQUIRED, IF DAMAGED IN ANY
Scale
N. MIAMI BEACH, FL 33179
MANNER, DURING CONSTRUCTION TO SATISFACTION
y
'
OF ARCHITECT & THE BUILDING.
4,1
SCOPE: GC SHALL PROVIDE ALL ELECTRICAL
2.16 HARDWARE SHALL BE PROVIDED BY GC AS
WORK AS SHOWN OR IMPLIED IN THESE
SPECIFIED. SEE MILLWORK DETAILS AND NOTES
Vk
.��y
,
DRAWINGS AND RELATED ENGINEERING
FOR SCOPE OF WOODWORKING AND HARDWARE.
'' "AR-
DRAWINGS (IF ANY) INCLUDING ALL CONDUIT
2.17 ALL SUBSTITUTIONS, I.E., "EQUALS" MUST BE
RUNS FOR POWER AND SIGNAL; DRAG LINES;
SUBMITTED TO ARCHITECT PROJECT MANAGER FOR
PULL BOXES; WIRING; RECEPTACLES AND
WRITTEN APPROVAL PRIOR TO SUBSTITUTION BEING
SWITCHING DEVICES; CORE DRILLING AND
MADE.
PATCHING; ETC.; AS SPECIFIED OR IMPLIED OR
2.18 GC SHALL REMOVE EXISTING FLOOR COVERING
AS REQUIRED BY CODE OR BUILDING
WHENEVER DESIGNATED FOR REMOVAL.
STANDARDS.
4.2
EQUIPMENT: TELEPHONE AND DATA
2.19 DEMISING PARTITIONS SHALL BE SPECIFIED
EQUIPMENT, TERMINALS, ETC., EXCEPT AS
WITH SOUND ATTENUATION BATTING,
SPECIFICALLY CALLED FOR, SHALL BE
UNLESS NOTED IN CD'S.
PROVIDED BY OTHERS. GC SHALL PROVIDE FOR
2.20 SOUND ATTENUATION BATTING SHALL BE SPECIFIED
COORDINATION WITH VENDORS/ INSTALLERS
AS PER CD'S.
REGARDING DELIVERIES, SCHEDULES, AS
2.21 SOUND ATTENUATION BATTING SHALL BE SPECIFIED
DIRECTED BY ARCHITECT.
AT ALL PARTITIONS AND CEILING FOR NEW RESTROOMS.
4.3
LOCATIONS AND DIMENSIONS SHALL BE PER
ARCHITECTURAL DRAWINGS; ENGINEERING
REFLECTED CEILING AND
DOCUMENTS (IF ANY) SHALL PREVAIL IN CASE OF
VARIATION IN SPECIFICATIONS. DISCREPANCIES
MECHANICAL SYSTEMS NOTES
MUST BE BROUGHT TO THE ATTENTION OF ARCHITECT
BEFORE START OF WORK. FURNITURE
3.1 SCOPE: GC SHALL FURNISH AND INSTALL
INDICATED ON PLANS IS FOR REFERENCE ONLY.
SUSPENDED GRID AND ACOUSTICAL TILE
4.4
VARIATIONS FROM WORK SPECIFIED DUE TO
CEILING MATERIAL AS SPECIFIED AND AS INDICATED
AVAILABILITY OF MATERIALS; FIELD CONDITIONS,
ON PLAN AND PROVIDE CUT OUTS AND OTHER
VARIATIONS IN EQUIPMENT SPECS, ETC., MAY BE
PROVISIONS FOR OTHER TRADES AS REQUIRED.
MADE WITH THE APPROVAL OF ARCHITECT.
3.2 CEILING GRID SYSTEM SHALL BE IN CONFORMANCE WITH
4.5
FIELD VERIFICATIONS: G.C. AND
ASTM C 635 AND WITH GENERAL PRACTICES AND
SUBCONTRACTORS SHALL BE RESPONSIBLE TO
APPLICABLE STATE AND LOCAL ORDINANCES. INSTALLATION
VERIFY FIELD CONDITIONS AND DIMENSIONS
SHALL BE IN CONFORMANCE WITH MANUFACTURERS
BEFORE BEGINNING WORK. SIZES OF CONDUITS
RECOMENDATIONS AND ASTM C 636.
AND PULL BOXES SHALL BE ADEQUATE FOR
CABLES /SERVICE SPECIFIED.
3.3 GC SHALL VERIFY CONFORMANCE WITH LOCAL AND
STATE CODES AND BUILDING STANDARDS BEFORE
4.6
ADJACENT TENANTS: GC SHALL INCLUDE
SUBMITTING FINAL PRICING.
REPAIRS TO ADJACENT TENANT SPACES WHEN
3.4 CEILING PLANE SHALL BE LEVEL AND TRUE, AND IN
WORK AFFECTS THOSE AREAS. WORK IN
ALIGNMENT WITH ALL LIGHTING, SPRINKLER, HVAC AND
ADJACENT TENANT SPACES SHALL NOT BE
OTHER ELEMENTS INCORPORATED IN ITS CONSTRUCTION.
SCHEDULED DURING NORMAL WORKING HOURS.
GRID SHALL BE CONTINUOUS THROUGHOUT THE DEMISED
4,7
COMPLIANCE: ALL WORK SHALL BE PERFORMED
AREA EXCEPT WHERE NOTED ON CDs.
IN COMPLETE COMPLIANCE WITH THE NATIONAL
3.5 PARTITIONS SHALL PENETRATE THE CEILING PLANE
ELECTRICAL CODE AND /ALL STATE OR LOCAL
(SEE CONSTRUCTION PLAN). ACOUSTICAL CONTRACTOR
CODES AND ORDINANCES HAVING JURISDICTION.
SHALL COORDINATE WORK WTH CARPENTRY TRADES
4.8
COMPATIBILITY: ALL DEVICES, WIRING, ETC.
TO PROVIDE FOR A NEAT, LEVEL VISUAL LINE AT THE
SHALL BE COMPATIBLE, EACH WITH ONE
INTERSECTION OF CEILING AND PARTITIONS.
ANOTHER AND WITH EXISTING WORK AND
3.6 FASCIAS /SOFFITS SHALL BE LEVEL AND TRUE, FREE
BUILDING STANDARDS.
OF SURFACE DISTORTION AND DIMENSIONED
4.9
CIRCUITING SHALL BE AS SHOWN ON ENGINEERING
ACCORDING TO DETAILS SHOWN.
DOCUMENTS.
3.7 MECHANICAL, HVAC AND PLUMBING ELEMENTS
4.10
PROTECTION: ALL ELECTRICAL DEVICES, WHEN
SHALL AT NO TIME COME IN CONTACT WITH CEILING
INSTALLED, SHALL BE PROTECTED FROM
CONSTRUCTION EXCEPT AS NECESSARY
DAMAGE BY OTHER TRADES. COVER PLATES
PENETRATIONS MAY REQUIRE.
SHALL BE INSTALLED AFTER FINISH MATERIALS
3.8 ACCESS SHALL BE PROVIDED BY GC AS REQUIRED
HAVE BEEN APPLIED. SEE FINISH PLAN.
FOR INSTALLATION AND MAINTENANCE OF
4.11
FLOOR OUTLETS SHALL BE FLUSH TYPE UNLESS
MECHANICAL, ELECTRICAL AND OTHER ELEMENTS
PROHIBITED BY BUILDING MANAGEMENT. GC.
WITHIN CEIUNG PLENUM AND AS REQUIRED BY
SHALL FURNISH CUT /SAMPLE TO ARCHITECT FOR
CODE. LOCATIONS FOR SPECIAL ACCESS DOORS,
APPROVAL. UNDER CARPET WRING MAY NOT BE
HATCHES, ETC. SHALL BE COORDINATED WTH
USED EXCEPT AS SPECIFIED AND AS LOCAL
OTHER TRADES AND APPROVED BY ARCHITECT. AS -BUILT
CODES AND BUILDING MANAGEMENT PERMITS.
REFERENCE PLANS SHALL BE PROVIDED TO ARCHITECT.
3.9 INSPECTIONS, AS REQUIRED BY LOCAL AUTHORITIES
4.12
SURFACE MOUNTED WRING DEVICES SHALL
SHALL BE COORDINATED BY GC PRIOR TO CLOSING
NOT BE USED BY GC, HIS SUBS OR ANY
OF CEILING.
ELECTRICAL VENDOR OR INSTALLER, EXCEPT AS
3.10 SHOP DRAWINGS FOR ALL RELATED TRADES PLUMBING,
(
SPECIFIED TO COORDINATE WITH FURNITURE
/MILLWORK INSTALLATION.
SPRINKLER, HVAC) SHALL BE SUBMITTED TO ARCHITECT
FOR REVIEW /APPROVAL PRIOR TO MANUFACTURING AND
4.13
COORDINATION OF ELECTRICAL WORK WITH
INSTALLATION. A COORDINATED SHOP DRAWING FOR
HVAC, CABINET WORK, CARPENTRY, FURNITURE,
ALL VISIBLE CEILING ELEMENTS SHALL BE SUBMITTED.
SHALL BE ASSURED BY GC.
ELECTRICAL PLAN NOTES CONT.
4.13 COORDINATION OF ELECTRICAL WORK WITH
HVAC, CABINET WORK, CARPENTRY, FURNITURE,
SHALL BE ASSURED BY GC.
4.14 RACEWAYS PROVIDED BY OTHERS WITHIN
CUSTOM CABINETRY AND MILLWORK OR OFFICE
LANDSCAPE PARTITION SYSTEMS SHALL BE
USED FOR ELECTRICAL INSTALLATIONS.
4.15 OFFICE LANDSCAPE PARTITIONS: MODULAR
POWER WAYS AND RECEPTACLE DEVICES FOR
ELECTRICAL SERVICE IN LANDSCAPE PARTITIONS
SHALL BE PROVIDED BY FURNITURE VENDOR
(EXCEPT WHERE PROHIBITED BY CODE).
ELECTRICAL SUBCONTRACTOR TO PROVIDE
FOR SERVICE TO POINT OF INTERFACE WITH
LANDSCAPE PANELS AND TO INSTALL DEVICES
IN ACCORDANCE WITH MANUFACTURER'S
SPECIFICATIONS.
4.16 AVAILABILITY OF ADEQUATE POWER SERVICE
SHALL BE VERIFIED BY ELECTRICAL
CONTRACTOR. COSTS FOR ADDITIONAL
CIRCUIT PANELS, TRANSFORMERS, ETC., IF
REQUIRED, SHALL BE INCLUDED IN BASE BID.
4.17 CONNECTION OF SERVICES: ELECTRICAL
CONTRACTOR SHALL PROVIDE FOR
CONNECTION OF TENANT TELEPHONE ROOM
WTH BUILDING TELEPHONE CLOSET AS REQ'D.
4.18 EXISTING SIGNAL CABLES, IF IN USE BY RESIDING
TENANTS, MAY NOT BE DISTURBED OR CUT. GC
SHALL BE RESPONSIBLE TO RESTORE ANY SERVICES
WHICH ARE INADVERTENTLY INTERRUPTED.
4.19 RAISED FLOOR AREAS WHEN SPECIFIED SHALL BE
PROVIDED WITH POWER GRID OF JUNCTION BOXES
MOUNTED TO SLAB WITH FLEXIBLE CONNECTIONS
MADE TO FLOOR MOUNTED SERVICE. PROVIDE
SUITABLE RECESSED SERVICE BOX WITH ACCESS
LID TO ACCEPT RECEPTACLE DEVICES AND CABLE
TERMINATION DEVICES.
4.20 REFER TO SCOPE OF MECHANICAL AND HVAC
INSTALLATIONS FOR RELATED ELECTRICAL WORK
TO BE INCLUDED.
4.21 BACK -TO -BACK ELECTRICAL OUTLETS MAY SHARE
COMMON DOUBLE ACCESS SERVICE BOX AND
CONDUIT SIZED FOR DOUBLE USE. (USE 2 -1/4"
EXTENSION COLLAR WTH MUD -RINGS BOTH SIDES.)
4.22 SLEEVES SHALL BE PROVIDED BY GC TO ALLOW
DATA / TELEPHONE CABLES TO PASS THROUGH FIRE
RATED PARTITIONS AND SHALL BE FIRESTOPPED BY G.C.
FURNITURE PLAN NOTES
5.1 SCOPE: ALL FURNITURE SHOWN IS TO BE PROVIDED
BY VENDORS OTHER THAN GC. SCOPE OF WORK BY
GC RELATED TO COORDINATION OF INSTALLATION
WITH VENDORS IS NOTED.
5.2 ALL FURNITURE AND EQUIPMENT IS NEW EXCEPT AS
NOTED.
5.3 FURNITURE SUPPLIER IS TO PROVIDE AND INSTALL
ALL FURNISHINGS SPECIFIED AS SHOWN WTH NO
SUBSTITUTIONS. PRICES ARE TO INCLUDE SHIPPING
AND FREIGHT CHARGES AND FEES, LICENSE,
PERMITS AND INSTALLATION BY QUALIFIED LABOR
DURING NORMAL BUSINESS HOURS. OVERTIME
DELIVERIES, IF REQUIRED BY BUILDING
MANAGEMENT ARE TO BE COORDINATED WTH AND
APPROVED BY ARCHITECT.
5.4 VENDOR SHALL ALLOW FOR ANY BUILDING
ELEVATOR USE FEES, LOADING DOCK FEES, ETC.
AND SHALL COORDINATE DELIVERY SCHEDULES
WITH BUILDING MANAGEMENT AND ARCHITECT.
5.5 VENDOR TO VERIFY CAPACITIES, DIMENSIONS OF
FREIGHT ELEVATORS AND DELIVERY PATH TO
ASSURE ADEQUATE PASSAGE.
5.6 COMPLIANCE WITH LOCAL CODES AND ORDINANCES
SHALL BE THE RESPONSIBILITY OF FURNITURE
Vfta4fIII>?2b9 G PAYMENT OF ANY FINES FOR
5.7 PROTECTION SHALL BE PROVIDED BY VENDOR FOR
ALL SURFACES SUSCEPTIBLE TO DAMAGE DURING
DELIVERY. VENDOR SHALL BE RESPONSIBLE TO
CORRECT ANY DAMAGES CAUSED BY DELIVERY.
5.8 BUILT -IN FILES AND CABINETS REQUIRE
COORDINATION WITH GC AND WORK BY OTHER
TRADES SPECIFIED IN OTHER SECTIONS.
FURNITURE VENDOR SHALL ASSEMBLE, PLACE AND
LEVEL CABINETS WITHIN ENCLOSURES PROVIDED.
(PLATFORMS, REVEAL STRIPS WORKTOPS, ETC., BY
MILLWORK CONTRACTOR.)
5.9 FREESTANDING FILE BANKS SHALL BE
LEVELED AND BOLTED TOGETHER BY VENDOR.
5.10 LOCKS ARE SPECIFIED FOR ALL FILE CABINETS.
CABINETS WTHIN ONE BANK SHALL BE KEYED ALIKE
5.11 LOCKS WHEN SPECIFIED FOR OFFICE SUITES AND
COMPONENT ASSEMBLIES SHALL BE KEYED ALIKE
5.12 TWO KEYS SHALL BE PROVIDED FOR EACH LOCK.
5.13 IDENTIFICATION NUMBERS /TAGS SHALL BE PROVIDED
FOR ALL LOCKS AND KEYS.
5.14 CONTRACTOR SHALL COORDINATE ALL HARDWARE
LOCKING REQUIREMENTS WITH TENANT, AND LANDLORD REP
I FINISH PLAN NOTES I
6.1 ALL FINISH MATERIAL INDICATED TO BE BY GC UNLESS
OTHERWISE NOTED IN FINISH SCHEDULES(S), ON FINISH
PLAN.
6.2 GC AND VENDORS SHALL DETERMINE AVAILABILITY OF
ALL FINISH MATERIALS. ANY DELIVERY SCHEDULE
THAT POTENTIALLY MAY CAUSE COORDINATION
PROBLEMS DURING THE FINAL STAGES OF
CONSTRUCTION /INSTALLATION SHALL BE BROUGHT
TO ATTENTION OF ARCHITECT , EARLY ON, FOR POSSIBLE
REEVALUATION OF MATERIAL DESIGNATION.
6.3 A MINIMUM QUANTITY OF TWO (2) 1' -0" X 1' -0"
FINISH SAMPLES OF ALL SPECIFIED FINISHES AND
CURRENT STOCK CUTTINGS OF ALL SPECIFIED WALL -
COVERINGS SHALL BE PROVIDED FOR APPROVAL
PRIOR TO ORDERING.
6.4 PAINT FOR WALL FINISHES SHALL BE PROVIDED AS A
THREE (3) COAT EGGSHELL LATEX ENAMEL PAINT
APPLICATION [ONE (1) PRIME AND TWO (2) FINISHED
COAT], COLORS AS SPECIFIED. METAL ELEMENTS AND
DOOR AND WINDOW FRAMES SHALL HAVE A THREE
COAT SEMI -GLOSS ALKYD ENAMEL FINISH.
6.5 GC SHALL ASSURE THAT NO ELECTRIC RECEPTACLE
OR TELECOMMUNICATIONS OUTLET COVERPLATES
HAVE BEEN INSTALLED PRIOR TO COMPLETION OF
APPLICATION OF ANY WALL FINISH MATERIALS.
ANY SUCH COVERPLATES OR SURFACE HARDWARE,
ETC., IN PLACE, SHALL BE REMOVED PRIOR TO
WALL FINISH APPLICATION.
6.6 UPON COMPLETION OF FINISH PHASE OF JOB, GC
SHALL REMOVE ALL PAINT, WALLCOVERING PASTE,
ETC., FROM WHERE IT HAS SPILLED, SPLASHED,
OR SPATTERED.
6.7 GC SHALL INSTALL ALL WALLCOVERINGS WHERE
DESIGNATED. ALL WALLCOVERING SHALL BE SMOOTH
WITH NO WRINKLES, BUBBLES, BLISTERS, OR LOOSE
EDGES. ALL EXCESS PASTE SHALL BE THOROUGHLY
REMOVED. WALLCOVERING ADJOINING WOOD OR METAL
PARTITIONS SHALL BE CUT STRAIGHT AND SQUARE.
WALLCOVERING AT ALL REVEALS SHALL RETURN INTO
REVEAL. ALL WORKMANSHIP WHICH IS NOT JUDGED
TO BE FIRST QUALITY BY ARCHITECT WILL NOT BE ACCEPTED.
NO WALLCOVERING SHALL TERMINATE ON A FLAT
SURFACE OR ON AN OUTSIDE CORNER. ALL WALL -
COVERING SHALL TERMINATE AT AN APPROPRIATE
REVEAL /BREAK OR INSIDE CORNER.
FINISH PLAN NOTES CONT.
6.8 ALL WALL SURFACES RECEIVING WALLCOVERING SHALL
BE PRIMED WITH A SUITABLE STRIPPAAI F PRIMING
MATERIAL. NO "ONE STEP" PRIMER /ADHESIVE SHALL
BE USED. SAID PRIMER SHALL BE COMPATIBLE WITH
THE RECOMMENDED ADHESIVE FOR RESPECTIVE WALL -
COVERING BEING USED.
6.9 ALL PARTITIONS SHALL RECEIVE VINYL BASE INSTALL-
ATION EXCEPT WHERE OTHERWISE NOTED. ALL SURFACES
RECEIVING BASE SHALL BE PREPARED AS REQUIRED.
A. AREAS INDICATED AS RECEIVING CARPET FLOOR
FINISH SHALL HAVE STRAIGHT BASE APPLIED,
PRIOR TO CARPET INSTALLATION.
B. AREAS INDICATED AS RECEIVING VINYL
COMPOSITION TILE FLOOR FINISH SHALL HAVE
COVED VINYL BASE APPLIED AFTER VINYL
COMPOSI1ION TILE INSTALLATION.
6.10 VINYL COMPOSITION TILE INSTALLATION SHALL BE
UNI- DIRECTIONAL. SEAMS SHALL BE TIGHT/
INVISIBLE. GC SHALL PROVIDE AND MAINTAIN
ADEQUATE PROTECTION FOR ALL NEW INSTALLED VINYL
COMPOSITION TILE FOR THE DURATION OF CONSTRUCTION
AND REMOVE PROTECTION ONLY IMMEDIATELY BEFORE
JOB COMPLETION, FLOOR WILL BE THOROUGHLY CLEANED
OF ALL ADHESIVE /CONSTRUCTION STAINS AND RECEIVE
APPROPRIATE TWO (2) COATS NON -SUP WAX APPLICATION
WHICH IS TO BE THOROUGHLY MACHINE BUFFED TO
SATISFACTION OF ARCHITECT. (CLEAN WAX BY G.C.)
A. GC TO SUPPLY AND INSTALL VINYL COMPOS111ON
TILE AND BASE; CARPET BY OTHERS. (UNLESS
OTHERWISE NOTED)
6. GC IS RESPONSIBLE FOR ALL FLASH PATCHING
AND TO HAVE FLOOR IN CONDITION TO RECEIVE
EITHER CARPET AND /OR VINYL COMPOSITION TILE.
6.11 GC SHALL PROVIDE AND MAINTAIN COMPLETE
PROTEC1ON FOR ALL NEW INSTALLED FLOOR FINISHES
(INCLUDING CARPET) UNTIL ALL CONSTRUCTION WORK
IS COMPLETE. PROTECTION SHALL BE REMOVED ONLY
IMMEDIATELY PRIOR TO JOB COMPLETION.
6.12 CARPET SUPPLIER /INSTALLER SHALL PROVIDE CURRENT
STOCK SAMPLES OF SPECIFIED CARPET FINISHES FOR
APPROVAL PRIOR TO ORDERING. PROVIDE VINYL
TRANSITION STRIPS AS SPECIFIED OR NECESSARY
(IF NOT SPECIFIED).
6.13 GC, ALL VENDORS /SUBCONTRACTORS ARE RESPONSIBLE
FOR FIELD VERIFICATION OF ALL DIMENSIONS, QUANTITIES
ETC., OF THEIR RESPECTIVE WORK.
6.14 DRAPERIES AND OTHER WINDOW COVERINGS MUST BE
BUILDING STANDARD. G.C. SHALL BE RESPONSIBLE FOR
SUPPLY /INSTALLATION AND BUILDING STANDARD WINDOW
TREATMENT ,WOOD BLOCKING /GROUNDS ABOVE CEILING AS
NECESSARY FOR VERTICAL BLINDS, DRAPERIES, ETC.,
(UNLESS OTHERWISE NOTED)
MILLWORK & CABINETRY NOTES
7.1 DESIGN CRITERIA AS SET FORTH IN SECTIONS 5.1
AND 5.2 SHALL GOVERN DESIGN OF MILLWORK AND
CABINETRY.
7.2 SCOPE: ALL FINISHED MILLWORK WOODWORKING,
AND CABINETRY INCLUDING WOOD DOORS, JAMBS,
FRAMES, WNDOW FRAMES, TRIM, COUNTERS,
PANELS, MOLDINGS, CABINET REVEALS, FILE
PLATFORMS, BLOCKING AND INSTALLATION OF
RELATED HARDWARE IS TO BE COMPLETED BY
MILLWORK CONTRACTOR (MC) AS SUBCONTRACTOR
TO GC UNLESS OTHERWISE NOTED.
7.3 SCHEDULING AND COORDINATION WTH OTHER
TRADES WLL BE THE RESPONSIBILITY OF THE GC
WHETHER MILLWORK IS INCLUDED IN HIS WORK OR
NOT.
7.4 FURNITURE AS SHOWN ON FURNITURE PLAN IS BY
OTHERS. REFER TO FURNITURE PLAN FOR
SCOPE OF WORK RELATED TO FURNITURE
INSTALLATION (FILE PLATFORMS, REVEALS, ETC.)
7.5 DETAILING OF MILLWORK SHALL BE AS SHOWN. GC
SHALL SUBMIT SHOP DRAWNGS AND FINISH SAMPLES
FOR REVIEW TO VERIFY CONFORMANCE TO SPECS.
7.6 FIELD MEASUREMENTS SHALL BE VERIFIED BY GC AS
REQUIRED. ARCHITECT WILL NOT VERIFY FIELD CONDITIONS
AND DIMENSIONS ON SHOP DRAWNGS.
7.7 COORDINATION OF MILLWORK WITH EXISTING AND
NEW CONSTRUCTION AND WITH MECHANICAL,
FURNITURE AND OTHER RELATED ELEMENTS SHALL
BE THE RESPONSIBILITY OF THE GC.
7.8 MATERIALS SHALL BE AS SPECIFIED AND OF HIGHEST
QUALITY BY ACCEPTED COMMERCIAL AND INDUSTRY
STANDARDS.
7.9 SUITABLE MOISTURE RESISTANT /WATERPROOF SUBSTRATE
SHALL BE USED FOR PLASTIC LAMINATE PIECES TO
PREVENT FAILURE DUE TO MOISTURE CONDITIONS.
7.10 SUBSTRATE FOR VENEERED AND LAMINATED
PANELS SHALL BE FURNITURE GRADE PLYWOOD
FOR ALL HORIZONTAL SURFACES AND SHELVES.
(HIGH DENSITY PARTICLE BOARD MAY BE USED FOR
VERTICAL ELEMENTS.)
7.11 EDGES OF VENEERED PANELS SHALL MATCH
SURFACE. EDGES LESS THAN 1" SHALL BE
HARDWOOD.
7.12 WOOD VENEERS SHALL BE SINGLE SHEET 1/20'
THICK WITH NO SPLICES (EXCEPT AS CALLED FOR).
JOINTS AND GRAIN DIRECTION SHALL BE INDICATED
ON SHOP DRAWINGS. ADJACENT JOINTED VENEERS
SHALL BE BOOK MATCHED UNLESS OTHERWISE
NOTED.
7.13 ALL VENEERS SHALL BE STAINED TO MATCH APPROVED
FINISH SAMPLE.
7.14 TYPICAL WOOD FINISH SHALL BE SHOP APPLIED
DEMI -PORE RUBBED LACQUER. ENTRY DOOR AND
FRAME SHALL BE FULL - FILLED RUBBED LACQUER
UNLESS OTHERWISE NOTED. ALL WOOD FINISH
SHALL INCLUDE: WASH COAT, SAND, STAIN, SEALER
(TWO COAT VINYL), TWO COAT TOP -COAT (AN
SYSTEM #2).
7.15 FINISH SAMPLES SHALL BE SUBMITTED FOR APPROVAL
PRIOR TO FABRICATION AND FINISHING PROCESS.
7.16 PLASTIC LAMINATE SHALL BE SHOP APPLIED
ACCORDING TO MANUFACTURERS SPECIFICATIONS.
7.17 PLASTIC LAMINATE SHALL BE ONE SINGLE SHEET ON
ANY ONE SURFACE. JOINTS, IF REQUIRED, SHALL BE
INDICATED ON SHOP DRAWINGS FOR APPROVAL.
ALL JOINTS SHALL BE TIGHT WITH NO SEPARATION.
7.18 WOOD DOOR AND WINDOW FRAMES, ETC., SHALL BE
SECURED TO SOLID WOOD GROUNDS /BLOCKING PROVIDED
AS PART OF CEILING AND WALL CONSTRUCTION.
7.19 DIMENSIONS FOR WOOD FRAMES SHALL BE FIELD
VERIFIED BY GC AFTER RELATED ADJACENT
CONSTRUCTION IS COMPLETE.
7.20 WOOD REVEAL FILLERSTRIPS SHALL BE PROVIDED BY
GC FOR ALL BUILT -IN CABINETS. FILLERS SHALL BE
OF CLOSE GRAINED STOCK, FILLED, SANDED AND
PAINTED (SEMI - GLOSS) TO MATCH ADJACENT
CONSTRUCTION (EXCEPT AS NOTED). FILLERS
SHALL BE INCLUDED FOR ALL BUILT -IN FILES,
STORAGE CABINETS, BOOKCASES, ETC.
7.21 INSTALLATION OF REVEAL STRIPS SHALL BE
EXECUTED IN A NEAT, WORKMAN LIKE MANNER
WITHOUT DAMAGE TO ADJACENT CABINETS OR
SURFACES. PIECES SHALL BE SCRIBED TO FIT AND
FASTENED TO BLOCKING.
7.22 GLASS PANEL SIZES AND JOINTS (INCLUDING JOINT
SEALANT) SHALL BE APPROVED BY ARCHITECT.
7.23 DOOR HARDWARE SHALL BE SUPPLIED AND INSTALLED BY GC.
7.24 HARDWARE WILL BE SPECIFIED BY ARCHITECT. SPECIFICATIONS
SHOULD BE THE BETTER OF BUILDING STANDARD OR
EQUIVALENT IN QUALITY REFER TO HARDWARE SPECS.
7.25 GC SHALL PROVIDE ALL REQUIRED SIGNAGE AND
IDENTIFICATION FOR ALL CABINETS AND EXTINGUISHERS.
GENERAL DEMOLITION NOTES:
8.1 REMOVE EXISTING RECEPTACLES, TELEPHONE, SWITCHES, AND ANY
ELECTRICAL DEVICES IN WALLS TO BE DEMOLISHED. RELOCATE ANY
OF THESE DEVICES AS INDICATED OR REQUIRED BY THE DRAWNGS,
ARCHITECT, OR OWNER REPRESENTATIVE. PROVIDE ARCHITECT WITH
AS -BUILT OF DRAWINGS OF FINAL INSTALLATION FOR RECORD
PURPOSES. CONTRACTOR IS NOTIFIED THAT NOT ALL EXISTING DEVICES
MAY HAVE BEEN INDICATED ON THE DRAWINGS AND THAT SOME
EXISTING ELECTRICAL DEVICES MAY NOT HAVE BEEN SHOWN IN THEIR
ACTUAL LOCATION. CONTRACTOR IS REQUIRED TO VISIT SITE AND
BECOME FAMILIAR WTH THE EXISTING CONDITIONS PRIOR TO
DETERMINING THE WORK THAT NEEDS TO BE ACCOMPLISHED AS PART
OF HIS /HER BID.
8.2 THE WORK SHALL INCLUDE THE FURNISHING OF ALL MATERIALS,
CUTTING, EXTENDING, CONNECTING, REPAIRING, ADAPTING, AND OTHER
WORKCOINCIOENTAL HERETO. TOGETHER WITH SUCH TEMPORARY
INSTALLATIONS AS MAY BE NECESSARY TO SATISFY THE DEMOLITION
PROGRAM. APPROVAL SHALL BE SECURED FROM THE LANDLORD/
ARCHITECT PRIOR TO CUTTING/DRILLING ANY STRUCTURAL SUPPORT.
8.3 ALL BUILDING CONSTRUCTION AFFECTED BY THE REMOVAL,
RELOCATION, INSTALLATION OF ANY PIECE OF EQUIPMENT SHALL BE
REPAIRED AND FINISHED AS REQUIRED TO MATCH EXISTING CONDITION
OR AS DIRECTED BY THE ARCHITECTURAL DRAWINGS, SPECIFICATIONS,
OR OWNER'S REPRESENTATIVE.
8.4 WHEN ELECTRICAL DEVICES ARE INSTALLED IN PARTITIONS OR
CEILINGS TO BE REMOVED, THE ELECTRICAL CONTRACTOR SHALL
DISCONNECT THEM UP TO THE NEXT OUTLET TO REMAIN OR BACK TO THE
FED THROUGH
REMAIN OUTLETS ARE E
PANEL BOARD. IF EXISTING TO E
DEMOLSHED PARTITIONS OR CEILINGS, THE CIRCUIT SHALL BE
REARRANGED TO MAINTAIN CIRCUIT CONTINUITY. WRE SHALL BE
REMOVED BACK TO SOURCE FROM INACCESSIBLE RACEWAYS NOT
REUSED. INSTALL BLANK PLATES ON FLUSH OUTLETS NOT REUSED. PLATE
COLOR SHALL MATCH ADJACENT SURFACE AS NEAR AS POSSIBLE IN
FINISHED AREAS.
8.5 ALL ELECTRICAL EQUIPMENT SHALL BE REMOVED FROM STRUCTURE
OTHER ELECTRICAL ITEMS ASSOCIATED WITH THIS WORK SHALL BE
REMOVED IF NOT REQUIRED FOR NEW EQUIPMENT TO CONTINUE IN
SERVICE.
8.6 CONTRACTOR SHALL DEMOLISH ANY INTERIOR FINISHES TO COMPLETE
THE NECESSARY AND PROPOSED WORK AS DIRECTED BY THE
ARCHITECTURAL DRAWINGS, INTERIOR DESIGN DRAWNGS, SPECIFICATIONS,
OR BY OWNER REPRESENTATIVES.
B.7 EXISTING FIXTURES, EQUIPMENT, AND ALL DEBRIS WHICH ARE
REQUIRED TO BE REMOVED SHALL BE REMOVED BY THE CONTRACTOR.
CONTRACTOR TO COORDINATE WTH OWNER REPRESENTATIVES PRIOR TO
REMOVAL OF SUCH.
9.8 ALL ELECTRICAL AND PLUMBING LINES WHICH REQUIRE REMOVAL OR
ALTERATION ARE TO BE DONE SO BY THE CONTRACTOR. LINES TO BE
CAPPED AND PREPARED FOR REMOVAL OR RE- ROUTING AS SPECIFIED
8.9 REMOVE ALL UTILITIES IN DEMOLITION AREAS AND CONSTRUCTION
AREAS IN A MANNER, AND IN THE TIME, SATISFACTORY TO THE UTILITY
COMPANY. IF UTILITY COMPANY DESIRES TO EFFECT THE REMOVAL OF
THE MATERIALS, THEY SHALL BE PERMITTED TO DO SO.
8.10 COVER ITEMS AS SPECIFIED BY OWNER /OWNER REPRESENTATIVE TO
PROTECT FROM DUST AND DEBRIS.
B.11 SALVAGED MATERIALS SHALL BE REMOVED, CLEANED, AND PREPARED
FOR RE- INSTALLATION. OWNER MAINTAINS OWNERSHIP OF ALL MATERIALS
UNLESS OTHERWSE SPECIFIED.
8.12 WHERE EXISTING WALLS, CEILINGS, AND FIXTURES HAVE BEEN REMOVED,
AREAS SHALL BE PATCHED TO MATCH EXISTING FINISHES, OR FINISHES
TO BE ADDED AS PER PLANS, INTERIOR DESIGNER, OR AS PER OWNER
8.13 WHERE EXISTING ACOUSTICAL CEILING PANELS ARE TO BE REMOVED,
MATERIALS SHALL BE REMOVED IN A MANNER
ACCEPTABLE TO BUILDING ARCHITECT /OWNER. CONTRACTOR SHALL
COORDINATE STORAGE AND /OR DISPOSAL OF SOLID MATERIALS WITH
BUILDING OWNER /REPRESENTATIVE.
B.14 WHERE EXISTING WORK IS DAMAGED IN THE EXECUTION OF THIS
CONTRACT, OR WHERE OPENINGS ARE LEFT DUE TO THE REMOVAL OF
PIPES, EQUIPMENT OR APPARATUS, THE SAME SHALL BE REPAIRED OR
CLOSED UP TO CORRESPOND IN MATERIAL, QUALITY, SHAPE AND FINISH
WITH THAT OF SIMILAR AND ADJOINING WORK, UNLESS OTHERWISE CALLED
FOR. WHERE DAMAGE IS UNREPAIRABLE, NEW ITEMS OR EQUIPMENT
SHALL BE PROVIDED. CONTRACTOR SHALL PROVIDE ALL NECESSARY
WATERPROOFING, FIRE STOPPING AND SEALING OF PENETRATIONS LEFT
FROM REMOVED EQUIPMENT OR PRODUCED BY THIS WORK.
8.15 INTERRUPTION OF EXISTING SERVICES AND /OR OPERATION OF
FACILITIES SHALL BE KEPT TO A MINIMUM. CONTRACTOR SHALL FURNISH
ALL MATERIALS REQUIRED WHENEVER TEMPORARY CONNECTIONS ARE
NECESSARY TO MAINTAIN CONTINUITY OF SERVICE. INTERRUPTION OF
EXISTING SERVICES, THE INSTALLATION OF TEMPORARY FACILITIES, AND
THE WORK OF MAKING FINAL CONNECTIONS TO THE NEW WORK SHALL BE
DONE ONLY AT SUCH TIMES PERMITTED AND SCHEDULED IN ADVANCE
BY THE ARCHITECT /OWNER WITHOUT ADDITIONAL COST. CARE MUST BE
USED IN REMOVING SERVICES TO AREAS BEING DEMOLISHED SO THAT
SERVICES TO OTHER AREAS WHICH MIGHT BE SERVED THROUGH THESE
AREAS WILL NOT BE INTERRUPTED.
8.16 WHERE DEMOLITION WORK REQUIRES TEMPORARY INTERRUPTION OF
ELECTRICAL, TELEPHONE, TV, ALARM OR COMMUNICATION SERVICES,
RESPECTIVE UTILITIES AND /OR COMPANY REPRESENTATIVES SHALL BE
NOTIFIED AS NECESSARY, AND ALL WORK DONE SHALL BE UNDER
SUPERVISION AND THEIR ESTABLISHED STANDARDS.
8.17 ALL LIGHTING FIXTURES, RECEPTACLES, SWTCHES, WRING DEVICES,
SPECIAL OUTLETS, TELEPHONE CABLES, TV CABLES, MISCELLANEOUS
SYSTEM WRING, POWER CONDUCTORS, CONDUITS, ELECTRICAL BOXES,
RACEWAYS AND ANY OTHER ELECTRICAL SYSTEM COMPONENTS
LOCATED IN THE AREAS SHOWN AS BEING DEMOLISHED OR NOT USED
AFTER WORK IS COMPLETED SHALL BE REMOVED UNLESS OTHERWISE
NOTED AS EXISTING TO REMAIN OR BE RELOCATED. CONDUITS RUNNING
IN SLAB AT FINISHED AREAS SHALL BE CUT FLUSH, PLUGGED AND
ABANDONED AFTER CONDUCTORS ARE REMOVED. NO WRING SHALL
BE LEFT ABANDONED AFTER WORK IS COMPLETED.
- - y.
I; :,I
- - G. %)
5
TUl4itl;(L C
`,. >:;
ESIZiN C1,
��3 --
:::. _
- � _ ... ,
:.
r!
_�rfa : r:t.:::: -,
15.1 JEVFLLA A�1ENUE; S_JITE 2GG - -
"
r
r.: ::., .
..
RATIVE
CORAL GABLES, FL 33134
OFFICE: (305) 442 -1188
Client Name
T (� ,
FAX: (305) 445 -1509
') a4
. t' .
WWW. ADCINTERNATIONAL.NET
1696 NE MIAMI GARDENS DR
0 Ir �° . `
SUITE 8
Scale
N. MIAMI BEACH, FL 33179
y
'
(305) 947 -8800
Ys,
.
-(-
,
yC
t ( t
Vk
.��y
,
' ) L.
STATE OF FLORIDA
'' "AR-
0010536
RAYMUNDO FEITO, R.A.
AA- CO01315
Architect • Seal/Signature
............ ............................... ........... ............................... ...................
MRA E XPANSION
SUNSET PROFESSIONAL BLDG
6280 SUNSET DR
SUITE 600
SOUTH MIAMI FL
Date Issue Description Drawn By Checked By
04 -13 -09 LANDLORD REVIEW ER ER
.............................................................. ............................... .
04 -27 -09 PERMIT ISSUE ER ER
Project Number
Client Name
09032
PROMED PROPERTIES
Description
Client Address
1696 NE MIAMI GARDENS DR
SUITE 8
Scale
N. MIAMI BEACH, FL 33179
Client Phone Number
(305) 947 -8800
CAD File Name
GENERAL NOTES
ot)V m1p,ml Consultant • Seal/Signature
Cps( of o14o j)SPT.
au►
00r 0AG SeCT100
,,aPRCNE1D� -D
2 -
A O. 2
3 OF 15