12-1192-002AREA OF WORK RESTROOM, REMODELEI LAVATORY REMOVE & CAP PLUMBING PIPES REMOVE & REPLACE FLOOR AND WALL TILE REMOVE & REPLACE COMPARTMENT AS SHOWN REPLACE W.C. AND URINAL SEE SPECS. REPLACE W.C. SEE SPECS. REMOVE & REPLACE COMPARTMENT AS - SHOWN REMOVE & REPLACE FLOOR AND WALL TILE REMOVE LAVATORY & CAP PLUMBING — PIPES REPLACE LAVATORIES & COUNTER, SEE SPECS. REPLACE LAVATORIES & COUNTER, SEE SPECS. ELECTRICAL ROOM MEN MECHANICAL n I ROOM WOMEN � � I � I � ELEVATOF S; ELEVATORS — — — LOBBY s I I I i I I i fl i I � � I RAMP UP RAMP UP min — — — - -- — — Li O O O O O O O O I O O O 0 O 0 29' -0" 28' -0" 28' -0" 28' -0" 27' -6" TYPICAL FLOOR PLAN (FROM 2ND FLOOR TO 8TH FLOOR) NOTE: EGRESS DOOR MUST BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT FBC 2010 NOTE: THE DOOR RELEASING MECHANISM FOR ANY LATCH SHALL BE LOCATED AT LEAST 34" & NOT MORE THAN 48" ABOVE THE FINISHED FLOOR FBC 2010 PENETRATION NOTE: CONTRACTOR SHALL SEAL ALL PENETRATIONS THROUGH EXISTING FIRE RATED PARTITION OR ROOF ASSEMBLY WITH " TREMCO "- FIRESTOP SYSTEM AS DETAILED MEETING ASTM -E814. INSTALL AS PER MANUF. RECOMMENDATION FOR 1, 2, 3, 4 HR. RATINGS. NOTE: THESE PLANS COMPLY WITH NEW F.B.C. 2010 BUILDING CONSTRUCTION CLASIFICATION III -A ALTERATION LEVEL 2 FBC 1033.1.1 ANY DOOR IN A REQUIRED MEANS OF EGRESS FROM AN AREA HAVING AN OCCUPANT OF 100 OR MORE PERSONS MUST BE PERMITTED TO BE PROVIDED WITH A LATCH OR ONLY IF IT IS PANIC HARDWARE OR FIRE EXIT HARDWARE DEMOLITION TYPICAL FLOOR PLAN (FROM 2ND FLOOR TO 8TH FLOOR) SCALE: 118"= l'-o" SCALE: 1/8"= V -0" GNP'lam +�� � `�• ` ry i� ` �,''4'� NOTE: RESTROOM DOOR LOCKS SHALL BE SUCH AS TO PERMIT OPENING OF THE DOOR FROM THE OUTSIDE IN AN EMERGENCY NOTE: ALL DOORS TO BE EQUIPPED WITH HANDICAPPED OPERABLE HANDLESS (I.E. LEVER HANDLESS '.• T',' OF S OILITll I�..ilAMz• }' JILDING DE T. Y' 3T SECTION BUILDING CONSTRUCTION TYPE: (AS PER -FBC 2010 CHAPTER 6 TABLE 601) SPRINKLERED BUILDING CLASSIFICATION: FLAME SPREAD CLASIFICATION MINIMUM INTERIOR FINISH CLASS CLASSIFICATION. INTERIOR WALL AND CEILING FINISH (AS PER -FBC. TABLE 803.5) FLAME SPREAD 0-25 ALTERATIONS -LEVEL 2 (AS PER -FBC 2010 EXISTING BUILDING CHAPTER 7, SECTION 701.1) NOTE: PROVIDE ONE CERTIFIED 2A -10BC FIRE EXTINGHISHER FOR EACH 3000 SQ. FT. AND WITH A MAX. TRAVEL DISTANCE TO REACH 75'. TOP NOT TO EXCEED 5' ABOVE FINISH FLOOR NOTE: - CLOSET DOORS MUST BE OPENABLE FROM INSIDE FBC 436.2 - BATHROOM DOORS MUST BE OPENABLE FROM THE OUTSIDE IN AN EMERGENCY FBC 436.3 NOTE: DOORS MUST BE OPENABLE WITH NOT MORE THAN ONE RELEASING OPERATION FBC 2010 NOTE: ALL DOORS TO BE EQUIPPED WITH HANDICAPPED OPERABLE HANDLESS I.E. LEVER HANDLESS FBC 2010 111 J oO r Z 5 M 0000 O Z 0. M U r7NNZ > � 1 p I N S �Qtl d �ZW ^^ 0 � Zoa0oz F -o W Z a- C) X 0 Ir C) o' ILU �Ln O N U I rmi. 0 co z wd• w0 >M o� W w LLJ O� U� �O zQ 2z U� O �_ o N �- U N = �._. (0 O U) cl) w ai i= N U U N � a_ Q M W ~O F d Z w O n <0 w = U F= -NZ, z w 1 W - Z Q N W zaN N .' 2 0 Z 0 1 0 Z N H Q LLJ U) O Z U w O U 0 aZo W<o Z Of wW w w �' �� O AL REVISIONS DESCRIPTION Project No. 12 -123 Date: 10 -27 -2012 Drawn By: PEDRO PUERTO/LM (305) 262 8075 Approved By: F.G.P. GQM EZ- pl�����i o i 1 \. w • �o : L, CC �: z �CF`SS�O���`� SH'ErT 110. A-2 OF X ELECTRICAL ROOM r MECHANICAL , i ROOM ;I ;•: II' 'sw �� ssu RESTROOM, REMODELEI LAVATORY REMOVE & CAP PLUMBING PIPES REMOVE & REPLACE FLOOR AND WALL TILE REMOVE & REPLACE COMPARTMENT AS SHOWN REPLACE W.C. AND URINAL SEE SPECS. REPLACE W.C. SEE SPECS. REMOVE & REPLACE COMPARTMENT AS - SHOWN REMOVE & REPLACE FLOOR AND WALL TILE REMOVE LAVATORY & CAP PLUMBING — PIPES REPLACE LAVATORIES & COUNTER, SEE SPECS. REPLACE LAVATORIES & COUNTER, SEE SPECS. ELECTRICAL ROOM MEN MECHANICAL n I ROOM WOMEN � � I � I � ELEVATOF S; ELEVATORS — — — LOBBY s I I I i I I i fl i I � � I RAMP UP RAMP UP min — — — - -- — — Li O O O O O O O O I O O O 0 O 0 29' -0" 28' -0" 28' -0" 28' -0" 27' -6" TYPICAL FLOOR PLAN (FROM 2ND FLOOR TO 8TH FLOOR) NOTE: EGRESS DOOR MUST BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT FBC 2010 NOTE: THE DOOR RELEASING MECHANISM FOR ANY LATCH SHALL BE LOCATED AT LEAST 34" & NOT MORE THAN 48" ABOVE THE FINISHED FLOOR FBC 2010 PENETRATION NOTE: CONTRACTOR SHALL SEAL ALL PENETRATIONS THROUGH EXISTING FIRE RATED PARTITION OR ROOF ASSEMBLY WITH " TREMCO "- FIRESTOP SYSTEM AS DETAILED MEETING ASTM -E814. INSTALL AS PER MANUF. RECOMMENDATION FOR 1, 2, 3, 4 HR. RATINGS. NOTE: THESE PLANS COMPLY WITH NEW F.B.C. 2010 BUILDING CONSTRUCTION CLASIFICATION III -A ALTERATION LEVEL 2 FBC 1033.1.1 ANY DOOR IN A REQUIRED MEANS OF EGRESS FROM AN AREA HAVING AN OCCUPANT OF 100 OR MORE PERSONS MUST BE PERMITTED TO BE PROVIDED WITH A LATCH OR ONLY IF IT IS PANIC HARDWARE OR FIRE EXIT HARDWARE DEMOLITION TYPICAL FLOOR PLAN (FROM 2ND FLOOR TO 8TH FLOOR) SCALE: 118"= l'-o" SCALE: 1/8"= V -0" GNP'lam +�� � `�• ` ry i� ` �,''4'� NOTE: RESTROOM DOOR LOCKS SHALL BE SUCH AS TO PERMIT OPENING OF THE DOOR FROM THE OUTSIDE IN AN EMERGENCY NOTE: ALL DOORS TO BE EQUIPPED WITH HANDICAPPED OPERABLE HANDLESS (I.E. LEVER HANDLESS '.• T',' OF S OILITll I�..ilAMz• }' JILDING DE T. Y' 3T SECTION BUILDING CONSTRUCTION TYPE: (AS PER -FBC 2010 CHAPTER 6 TABLE 601) SPRINKLERED BUILDING CLASSIFICATION: FLAME SPREAD CLASIFICATION MINIMUM INTERIOR FINISH CLASS CLASSIFICATION. INTERIOR WALL AND CEILING FINISH (AS PER -FBC. TABLE 803.5) FLAME SPREAD 0-25 ALTERATIONS -LEVEL 2 (AS PER -FBC 2010 EXISTING BUILDING CHAPTER 7, SECTION 701.1) NOTE: PROVIDE ONE CERTIFIED 2A -10BC FIRE EXTINGHISHER FOR EACH 3000 SQ. FT. AND WITH A MAX. TRAVEL DISTANCE TO REACH 75'. TOP NOT TO EXCEED 5' ABOVE FINISH FLOOR NOTE: - CLOSET DOORS MUST BE OPENABLE FROM INSIDE FBC 436.2 - BATHROOM DOORS MUST BE OPENABLE FROM THE OUTSIDE IN AN EMERGENCY FBC 436.3 NOTE: DOORS MUST BE OPENABLE WITH NOT MORE THAN ONE RELEASING OPERATION FBC 2010 NOTE: ALL DOORS TO BE EQUIPPED WITH HANDICAPPED OPERABLE HANDLESS I.E. LEVER HANDLESS FBC 2010 111 J oO r Z 5 M 0000 O Z 0. M U r7NNZ > � 1 p I N S �Qtl d �ZW ^^ 0 � Zoa0oz F -o W Z a- C) X 0 Ir C) o' ILU �Ln O N U I rmi. 0 co z wd• w0 >M o� W w LLJ O� U� �O zQ 2z U� O �_ o N �- U N = �._. (0 O U) cl) w ai i= N U U N � a_ Q M W ~O F d Z w O n <0 w = U F= -NZ, z w 1 W - Z Q N W zaN N .' 2 0 Z 0 1 0 Z N H Q LLJ U) O Z U w O U 0 aZo W<o Z Of wW w w �' �� O AL REVISIONS DESCRIPTION Project No. 12 -123 Date: 10 -27 -2012 Drawn By: PEDRO PUERTO/LM (305) 262 8075 Approved By: F.G.P. GQM EZ- pl�����i o i 1 \. w • �o : L, CC �: z �CF`SS�O���`� SH'ErT 110. A-2 OF X