Loading...
10-988-015GENERAL ELECTRICAL NOTES 1. ALL WORK SHALL CONFORM WITH ALL LOCAL, STATE, FEDERAL ORDINANCES AND BUILDING CODES GOVERNING THE INSTALLATION OF THE ELECTRICAL SYSTEM. IF WORK AS LAID OUT, INDICATED OR SPECIFIED IS CONTRARY TO OR CONFLICTS WITH LOCAL ORDINANCES, BUILDING CODES AND REGULA- TIONS, THE CONTRACTOR SHALL REPORT IN WRITING TO THE ARCHITECT/ ENGINEER BEFORE SUBMITTING A BID. THE ARCHITECT /ENGINEER WILL THEN ISSUE INSTRUCTIONS AS HOW TO PROCEED. 2. THE DRAWING ARE TO BE CONSIDERED DIAGRAMMATIC, NOT NECESSARLY SHOWING IN DETAIL OR TO SCALE ALL OF THE MINOR ITEMS, UNLESS SPECIFIC C C DIMENSIONS ARE SHOWN, THE STRUCTURAL, ARCHITECTURAL AND SITE CONDITIONS SHALL GOVERN THE EXACT LOCATIONS. NTRA T R CO C 0 SHALL FOLLOW DRAWINGS IN LAYING OUT WORK, CHECK DRAWINGS OF ALL TRADES TO VERIFY SPACES IN WHICH WORK WILL BE INSTALLED AND MAINTAIN MAXIMUM HEAD ROOM, R U E D 00 0 SPACE CONDITIONS AT ALL P INT HEAD POINTS. WHERE E E E D ROOM, OR SPACE CONDITIONS APPEAR INADEQUATE, ARCHITECT /ENGINEER SHALL BE NOTIFIED BEFORE PROCEEDING WITH INSTALLATION. THIS CONTRAC- TOR SHALL, WITHOUT EXTRA CHARGE, MAKE FIELD MODIFICATION IN LAYOUT AS NEEDED TO PREVENT CONFLICT WITH WORK OF VARIOUS TRADES OR FOR PROPER EXECUTION OF THE WORK. 1 EXAMINE ALL DRAWINGS CAREFULLY PRIOR TO SUBMITTING A BID. CONTRACTOR WILL BE REQUIRED TO FURNISH, INSTALL AND /OR CONNECT WITH APPROPRIATE ,SERVICES ALL ELECTRICAL ITEMS SHOWN ON ANY OF THE ARCHITECTURAL, PLUMBING, AIR CONDITIONING, SPRINKLER, DRAWINGS WITHOUT ADDITIONAL EXPENSE TO THE OWNER. IF DISCREPANCIES, CONFLICTS, INTERFERENCES OR OMISSIONS OCCUR BETWEEN EEN DRAWINGS NOTIFY IN 8 WRITING THE ARCHITECT/ ENGINEER IN AMPLE TIME TO PERMIT REVISIONS BEFORE THE BIDS ARE U ITT S BM ED . 4. VERIFY SERVICE CHARACTERISTICS, LOCATION AND CONNECTION WITH TELEPHONE AND ELECTRIC UTILITY COMPANIES PERFORM ALL WORK RELATED TO SERVICE IN STRICT ACCORDANCE WITH UTILITY Co. STANDARDS AND REQUIREMENTS. 5. INSTALL MATERIALS AND EQUIPMENT IN A NEAT AND FIRST S WORKMANLIKE CLP S MANNER. THE OWNER RESERVES THE RIGHT TO DIRECT REMOVAL AND REPLACE- MENT OF ITEM WHICH, IN HIS OPINION, DO NOT PRESENT A NEAT AND WORKMAN- LIKE APPEARANCE. REMOVAL AND REPLACEMENT IS TO BE DONE IMMEDIATELY WHEN DIRECTED BY THE OWNER IN WRITING, AT THE SOLE EXPENSE OF CONTRAC- TOR. 6. START OF WORK BY CONTRACTOR SHALL BE CONSIDERED AS ACCEPTANCE BY HIM OF ALL CLAIMS OR QUESTIONS AS TO SUITABILITY OF THE WORK OF OTHER TRADES OR OTHER CONTRACTORS TO RECEIVE HIS WORK. THIS CONTRACTOR SHALL REMOVE AND REPLACE, AT HIS EXPENSE, ALL ELECTRICAL WORK WHICH MAY HAVE TO BE REMOVED BECAUSE OF INTERFERENCE WITH OTHER TRADES. 7. THIS CONTRACTOR SHALL OBTAIN AND PAY ALL INSURANCE, FEES, PERMITS ASSO- CIATION DUES, ROYALTIES, AND TAXES OF WHATEVER NATURE SHALL APPLY TO THIS WORK. HE SHALL ALSO PAY ALL INSPECTION FEES AS MAY BE REQUIRED BY LAW OR ORDINANCE AND SHALL KEEP THE OWNER HARMLESS FROM ANY DAMAGE AND EXPENSE ARISING FROM ANY VIOLATION OF THE LAWS, RULES OR ORDINANCES. 8. ALL WIRE TO BE COPPER, IN RACEWAY, UNLESS OTHERWISE" SPECIFIED ON DRAWINGS. 9. PROVIDE EMPTY RACEWAYS FOR TELEPHONE SYSTEM 10. PROVIDE MEANS "FURNISH AND INSTALL ". 11. COORDINATE WORK WITH WORK OF OTHER TRADES TO AVOID ALL CONFLICTS. 12. DO A COMPLETE JOB, EVERYTHING CONNECTED, READY FOR USE. 13, PROVIDE TEMPORARY WIRING SYSTEM FOR USE OF ALL TRADES, ADEQUATE FOR ENTIRE NEEDS OF THIS PROJECTS. 14, PROVIDE PULL WIRES WHEN EMPTY CONDUITS ARE SHOWN ON THE PLANS. 15. PROVIDE LIGHT FIXTURES AS PER LIGHTING FIXTURE SCHEDULE. 16. PROVIDE EMPTY PVC RACEWAYS (SERVICE ENTRANCE) FOR TELEPHONE Co, AS PER THEIR REQUIREMENTS AND DIRECTIONS. 17, PROVIDE ALL WIRING DEVICES. 18. IDENTIFY CLEARLY ON A TYPE WRITTEN FORM ALL CIRCUITS AND EQUIPMENT TO CORRESPOND WITH THE PLANS AND PANELS SCHEDULE AND ATTACH INSIDE THE PERTAINING PANEL. 19. RACEWAYS: ALL UNDERGROUND RACEWAYS TO BE PVC, INSIDE CONCRETE SLAB EMT WITH APPROVED SET SCREW FITTING, INSIDE PARTITION EPv1T, do ENT. FOR FLOOR PENETRATION USE ONLY EMT. 20. SHOP DRAWINGS: THIS CONTRACTOR SHALL FURNISH THE ENGINEER WITH SHOP DRAWINGS OF EQUIPMENT PRIOR TO PURCHASE FOR APPROVAL. 21. TESTING: THE CONTRACTOR SHALL TEST ALL WORK AND EQUIPMENT AS DIRECTED BY THE ARCHITECT AND BY AUTHORITIES HAVING JURISDICTION, FURNISHING ALL EQUIPMENT AND NECESSARY PERSONNEL AND ELECTRIC POWER. THE ENTIRE INSTALLATION SHALL BE TESTED FOR SHORTS, GROUNDS AND OPEN CIRCUITS, AND ALL DEFECTS SHALL BE DEMONSTRATED TO BE IN PROPER WORKING AND OPERATING CONDITION TO THE COMPLETE SATISFACTION OF THE ENGINEER. 22. GUARANTEES: ALL EQUIPMENT AND MATERIALS SHALL BE GUARANTEED FOR ONE YEAR AFTER THE DATE OF ACCEPTANCE BY OWNER. 23. AT COMPLETION OF JOB THE ELECTRICAL CONTRACTOR SHALL GIVE THE OWNER AN AS- BUILT SET OF REPRODUCTIBLE SEPIAS SHOWING THE EXACT ELECTRICAL INSTALLATION. 24. BEFORE BIDDING THE JOB THE ELECTRICAL CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH ALL EXISTING CONDITIONS. MANUFACTURER: SIEMENS r q n MAINS: M,I_ -O, AIC: 10 K PAN E L- r A MOUNTING: SURFACE BUS RATING: ?OOA LOCATION: ELECTRICAL CLOSET (EXISTING) VOLTAGE: 120Z24OV, 1 PH, 3W CKT. POLE/ KVA DESCRIPTION WIRING & CKT. POLE/ KVA DESCRIPTION WIRING & NO. TRIP KVA DESCRIPTION CONDUIT NO. TRIP KVA DESCRIPTION CONDUIT 1 1/20 0.50 CASH WRAP DED. RECEPTACLE 3 #12 -1/2" 2 1/20 1.40 SALES AREA LIGHTING 3 #12 -1/2" 3 12 0 . 0 50 CASH WRAP DED RECEPTACLE 3�1 ?. -1/2 4 1/2fl 1.04 BACK OF HOUSE LIGHTING 3# 12-1/2" 5 1120 0.50 CASH WRAP DED. RECEPTACLE 3 #12 -1/2" 6 _- - 1120 1.54 SALES AREA LIGHTING 3 #12 -1/2" 7 1/20 0.50 SALES COUNTER DED, RECEPT. 3#12-1/2" 8 1 /20 1.17 BAY AREA LIGHTING 3#12-1/2" 9 1120 1.08 SALES AREA GEN. RECEPTACLE 3 #12 -1/2" 10 1/20 0.00 SPARE - 11 1120 1.08 SALES AREA GEN. RECEPTACLE 3#12-1/2" - 1/20 0.00 SPARE SPARE - 2 1/20 0.00 SPARE 14 1/20 1.40 SALES AREA LIGHTING 3#12-1/2" 15 V30 D.DO SPARE _ - 16 6 18 1/20 1/20 0.60 1.20 EXISTING BATHROOM LIGHTING EDWIN WATTS SIGN EXISTING 3 #12 -1/2" 17 1120 0.70 CLUB REPAIR RECEPTACLE 3 #12 -112" 19 1/20 0.50 DED. COMMUNICATIONS RECEIPT. 3 #12 -1/2'" 20 1120 0.36 SERVICE RECEPTACLE 3 #12 -1/2" 21 1/20 0.50 DED. COMMUNICATIONS RECEIPT. 3 #12 -1/2" 22 1/20 1.50 SHOW WINDOW RECEPTACLE 3#12-1/2" 23 1/20 1.08 SALES AREA GEN. RECEPTACLE 3 #12 -1/2" 24 1/20 1.5_0 SHOW WINDOW RECEPTACLE 3#12-1/2" 25 1/20 0.60 DRINKING FOUNTAINS 3 #12 -1/2" 26 1/20 0.00 SPARE - 27 _ 1 20 0.9 0 CLUB REPAIR RECEPTACLE __. 312 -1/2 28 1/20 0,00 SPARE SPACE 29 1/20 0.90 CLUB REPAIR RECEPTACLE 3 #12 -1/2" 30 1/20 0.00 SPARE - 31 1/2,0 0.00 SPARE - 32 1/20 0.25 EXISTING SECURITY RECEPTACLE EXISTING 33 1120 0.00 SPARE - 34 1120 0.00 SPARE - 35 1/20 0.00 SPARE - 36 1/20 0.00 SPARE - 39 1/20 0.00 SPARE - 38 1/20 - SPACE - 39 1120 0.00 SPARE - 4O 1120 - SPACE - TOTAL 9.34 TOTAL 12.16 TOTAL CONNECTED LOAD = 21.50 KVA = 89.5E AMPS FED VIA EXISTING 24 HOUR 7 DAY TIMECLOCK TO REMAIN. NOTE: THIS EXISTING PANEL IS FED BY EXISTING WITH 3 #310 THHN THWN COPPER WIRES IN 2" CONDUIT VIA A 3/200/200 FUSED DISCONNECT SWITCH LOCATED IN NEARBY COMMON ELECTRICAL ROOM. NO NEW LOADS HAVE BEEN ADDED. ELECTRICAL LEGEND (E) DENOTES EXISTING GFI GROUND FAULT CIRCUIT INTERRUPTER WP WEATHER PROOF WR WEATHER RATED HOMERUN DESIGNATION 20A, 125V, 2P, 3W DUPLEX RECEPTACLE NEMA 5 -2.0R MOUNTED 18" AFF, 20A 125V, 2P, 3W DUPLEX RECEPTACLE NEMA 5--20R MOUNTED 42" AFF, OR 6" ABOVE COUNTER BACKSPLASH 120V 1 POLE QUIET TYPE TOGGLE LIGHT SWITCH (MTD 48" A.F.F.) 120V 2 POLE QUIET TYPE 3 WAY TOGGLE LIGHT SWITCH (MTD 48" A.F.F.) EXISTING 120V 1 POLE QUIET TYPE TOGGLE LIGHT SWITCH (MTD 48" A.F,F.) TO REMAIN. DATA /COMMUNICATIONS OUTLET WITH 3/4' CONDUIT STUBBED TO CEILING SPACE. PROVIDE LV1 LOW VOLTAGE ADAPTER. OUTLET SHALL BE CABLE OF HANDLING UP TO 6 DATA /COMMUNICATIONS PORTS, JUNCTION BOX SINGLE STATION SMOKE DETECTOR /SMOKE ALARM WITH © BATTERY BACKUP AND SOUNDER BASE WIRED TO UNSWITCHED LIGHTING CIRCUIT. LOCATE MIN. OF 3 FEET FROM ANY A/C VENT. was* •e• f • •sr•• •r• • • • • Y r ••s•• was •a• • r • •r•• a • • • • • u • i • • • • r rY• • r • • • • •r• err • Y r •Y • • • • • • • • • s r r • Y Y U • Y ss• • 640f r•!•• ••U •••i r r r • • • • ••r• r •••a• • uYU • r!•r • MANUFACTURER: GOULDS P/'1NEL -nprr MAINS: M.L.O. AIC: 10 K ' �I G CC�i MOUNTING: SURFACE BUS RATING: QOA LOCATION: SALES AREA (EXISTING) VOLTAGE: 120/24OV, 1 PH, 3W - LA PS MBS I TYPE SYMBOL DESCRIPTION MANUFACTURER CKT. NO. POLE/ TRIP KVA DESCRIPTION WIRING & CONDUIT CKT. NO. POLE/ TRIP KVA DESCRIPTION WIRING & CONDUIT 1 1/20 0.90 BAY AREA RECEPTACLE _..._... _.._._._....._. -_� 3 #12 -1/2" 2 X 11.50 EXISTING AHU /CU -1 EXISTING 3 1/20 0.90 _ OFFICE RECEPTACLE -._. --� 3#12-1/2" 4 5 1130 1.26 SALES AREA RECEPTACLE 3 #12 -1/2 "- 6 1/20 0.00 SPARE - 7 1 2 -.- / 0 0.50 N RECEPTACLE 3# 12 -1 /2 E ' 1120 0,00 SPARE - 9 . -- - - - - -_ 1/20 _ .. - .......__ 0.00 SPARE - 10 1/20 0.00 SPARE - 11 1/20 0.00 SPARE - 12 14 1120 1120 0.00 0.00 SPARE SPARE - 13 1/20 0.00 SPARE - 15 1/20 0.00 SPARE - 16 '1 /20 0.00 SPARE - 17 1/20 0.00 SPARE - 18 1120 0.00 SPARE - 19 1/20 0.00 SPARE - 20 ; 1 /20 0.00 SPARE - 21 1/20 0.00 SPARE - 22 1/20 0.00 SPARE - 23 1/20 0.00 SPARE _ 24 1/20 0.00 SPARE - 25 1/20 0.00 SPARE - 26 1/20 0.00 SPARE - 27 - - SPACE - 28 1/20 0.00 SPARE - 29 - 120 SPACE - 30 - - SPACE - 31 - SPACE - 32 FLUORESCENT FIXTURE, - SPACE - 33 _ - SPACE - 34 - - - - SPACE SPACE - - 35 - - SPACE - 36 37 - - SPACE - 38 - - SPACE - 39 - 120 SPACE T -_ .._._ - 40 - - SPACE - 41 - - SPACE - 42 - - ....._.__------------ ..__.- :.. -_._ SPACE _.�.. - TOTAL 3.56 TOTAL 11.50 TOTAL CONNECTED LOAD = 15.06 KVA = 62.75 AMPS NOTE: THIS EXISTING PANEL IS FED BY EXISTING WITH 3 #1 THHN THWN COPPER WIRES IN 1 -1/4" CONDUIT VIA A 2/200/125 FUSED DISCONNECT SWITCH LOCATED IN NEARBY COMMON ELECTRICAL ROOM. NO NEW LOADS HAVE BEEN ADDED. LIGHTING FIXTURE SCHEDULE LA PS MBS TYPE SYMBOL DESCRIPTION MANUFACTURER CAT No VOLTAGE REMARKS N� . TYPE ■ NEW 2X2 LAY IN GRID 9 CEL PARABOLIC FLUORESCENT FIXTURE TO MATCH EXISTING BY OWNER BY OWNER 2 U -32 T8 120 U.L. LISTED B © NEW 2X2 LAY IN GRID 9 CEL PARABOLIC EMERGENCY OWNER EMERGENCY BATTERY BALLAST TO POWER BOTH FLUORESCENT FIXTURE TO MATCH EXISTING BY BY OWNER 2 U -32 T8 120 LAMPS. WIRED TO UNSWITCHED LIGHTING CIRCUIT. U,L. LISTED. EXISTING 2X2 LAY IN GRID 9 CEL PARABOLIC BY OWNER BY FLUORESCENT FIXTURE OWNER 2 U-32 T8 120 U.L. LISTED IT 77 RELOCATED 2X2 LAY IN GRID 9 CEL PARABOLIC LL 41 FLUORESCENT FIXTURE RY OWNER BY OWNER 2 U--32 T8 120 U.L. LISTED RELOCATED 2X2 LAY IN GRID 9 CEL PARABOLIC EMERGENCY BATTERY BALLAST TO POWER BOTH EMERGENCY FLUORESCENT FIXTURE BY OWNER BY OWNER 2 U--32 T8 120 LAMPS. WIRED TO UNSWITCHED LIGHTING CIRCUIT. U.L. LISTED. NEW 2X4 HARD CEILING 18 CEL PARABOLIC BY OWNER BY OWNER FLUORESCENT FIXTURE. 3 F32 -T8 120 U.L. LISTED NEW 2X4 HARD CEILING 18 GEL PARABOLIC EMERGENCY OWNER BY EMERGENCY BATTERY BALLAST TO POWER THREE �=✓ FLUORESCENT FIXTURE, BY OWNER 3 F32 -T8 120 LAMPS. WIRED TO UNSWITCHED LIGHTING CIRCUIT. U.L. LISTED, EXISTING RECESSED HIGH HAT TO REMAIN BY OWNER BY OWNER 1 100W COMP FL 120 U.L, LISTED I 0 RELOCATED RECESSED HIGH HAT BY OWNER BY OWNER 1 10OW COMP FL 120 U.L. LISTED (J EXISTING EMERGENCY LIGHT WALL PACK TO REMAIN BY OWNER BY OWNER 2 26W INC 120 WIRED TO UNSWICHED LIGHTING CIRCUIT. U.L. LISTED. ' EXISTING EMERGENCY EXIT LIGHT TO REMAIN BY OWNER BY OWNER 1 16W INC. 12@ BATTERY PACK WIRED TO UNSWICHED LIGHTING CIRCUIT. U.L. LISTED. RELOCATED EMERGENCY EXIT LIGHT TO REMAIN BY OWNER BY OWNER 2 16W INC. 120 BATTERY PACK WIRED TO UNSWICHED LIGHTING CIRCUIT. U.L. LISTED. D U z z In l0 W LO In W Cl) z Z join CJ Eq Z U' �- �TMZ�Q z ft J o m N O N W rrlQq -1 Wti W LO m 0- T N Z °10N 0 to °o LL W Q � Il1<QU OLD m W _ F- W W W z O ♦_ 0 LL ;. C) w U) uJ u i-- z uJ ' U Cf) Qom.. Lu O >- _ < W 0_ LLJ 0 CV) � w W(v) �- W W r O Z n H 05- , �r w Ft s ll CN- W � r y • i �x M ARC `T UZE, P. E LIC, NO. 59525 Owner of Documents Notice grnwinp anal w,cM est'lene a Irumummnts of som", are the oxclu" rr•p", of T•;,r_f E,n/InWnl CDnauhantm Inc., wt~ the lmr•)•mt forwh*hVW were proper" fe exoculaal an4 awstnxi" er rest Thee eleeumame are hot " be relar•Muceal In arty form am tW arm net M M umd ey t. project owner er eMwr entles an arty Ylher projeolm or for ah ration M the original project, ~ * the wthr a uthorization from Mils Engineer. Revisions No. Date: Jab no. 10008 -ESM Date: 10/13/10 Drawn by: T.E.C. Checked by: T.E.C. SHEET EI�3