Loading...
12-508-022D1 O 00 O O O O O ---------- --------------------- LIGHTING PLAN NOTES: 1. NEW FIXTURES SHALL BE CONNECTED TO 277 VOLT CIRCUITS LEFT SPARE BY DEMOLITION. PROVIDE NEW CONDUITMIRING AS REQUIRED. 2. PROVIDE WHERE INDICATED NEW THREE -WAY SWITCHES TO CONTROL EXISTING CORRIDOR LIGHTS AFFECTED BY NETWORK LAYOUT. 3. NEW EXIT SIGNS SHALL BE CONNECTED TO EXISTING EXIT SIGN CIRCUIT LEFT SPARE BY DEMOLITION. 1 OVERALL FLOOR PLAN LIGHTING - ELECTRICAL E1.1 SCALE: 3 /16 " =1' -0" I 5-A ARCHITECT: BERMELLO AJAMIL & PARTNERS, INC. Architecture Engineering Planning Interior Design Landscape Architecture 2601 South Bayshore Drive 10th Floor Miami, Florida 33133 (305) 859 -2050 Fax (305) 860 -3700 li LOUIS J. AGUIRRE & ASSOCIATES. P.A. Consulting Engineers 9150 South Dadeland Blvd. • Suite 900 Miami • Florida 33156 • E80000924 Telephone 305.670.0141 Facsimile 305.670.0144 www.1igapa.com Project No.: 22007 PERMIT SET 4/13/2612 REVISIONS: PROJECT PROJECT ADDRESS: 7400 S.W. 62nd Ave. South Miami, Florida 33143 COMM. NO. 40068 SCALE: AS SHOWN DATE: 04/13/2011 DRAWN: AP CHECKED: CADD FILE: v/22007 -MEP DRAWING TITLE: OVERALL FLOOR PLAN LIGHTING ELECTRICAL SHEET NO. E1.1 LAMPS FIXTURE MANUFACTURER & CATALOG No. TYPE MOUNTING REMARKS SERVICE TOTAL (OR APPROVED EQUIVALENT) NO. TYPE WATTS VOLTS WATTS LIGHTOLIER RECESSED 2 F28TBXLL 28 UNIV 49 2 X4 RECESSED DIRECT/ INDIRECT H952GLR232UNVVP2 ALTO 841 LIGHTOLIER OB SURFACE 1 F28TB 28 UNIV 29 4' STRIP IN LIGHT COVE ST4WA132UNVP2 �C LIGHTOLIER RECESSED 1 PLT 18 UNIV 19 DOWNUTE - ROUND 1101 F1842U -1177S H LIGHTOLIER OX UNIV - INCLUDED - 277 - ARROWS AS PER LIGHTING PLAN EXSERIES REMARKS: 1. PROVIDE ELECTRONIC BALLAST AND IN -LINE FUSE TO ALL FLOURESCENT FIXTURE. LIGHTING PLAN NOTES: 1. NEW FIXTURES SHALL BE CONNECTED TO 277 VOLT CIRCUITS LEFT SPARE BY DEMOLITION. PROVIDE NEW CONDUITMIRING AS REQUIRED. 2. PROVIDE WHERE INDICATED NEW THREE -WAY SWITCHES TO CONTROL EXISTING CORRIDOR LIGHTS AFFECTED BY NETWORK LAYOUT. 3. NEW EXIT SIGNS SHALL BE CONNECTED TO EXISTING EXIT SIGN CIRCUIT LEFT SPARE BY DEMOLITION. 1 OVERALL FLOOR PLAN LIGHTING - ELECTRICAL E1.1 SCALE: 3 /16 " =1' -0" I 5-A ARCHITECT: BERMELLO AJAMIL & PARTNERS, INC. Architecture Engineering Planning Interior Design Landscape Architecture 2601 South Bayshore Drive 10th Floor Miami, Florida 33133 (305) 859 -2050 Fax (305) 860 -3700 li LOUIS J. AGUIRRE & ASSOCIATES. P.A. Consulting Engineers 9150 South Dadeland Blvd. • Suite 900 Miami • Florida 33156 • E80000924 Telephone 305.670.0141 Facsimile 305.670.0144 www.1igapa.com Project No.: 22007 PERMIT SET 4/13/2612 REVISIONS: PROJECT PROJECT ADDRESS: 7400 S.W. 62nd Ave. South Miami, Florida 33143 COMM. NO. 40068 SCALE: AS SHOWN DATE: 04/13/2011 DRAWN: AP CHECKED: CADD FILE: v/22007 -MEP DRAWING TITLE: OVERALL FLOOR PLAN LIGHTING ELECTRICAL SHEET NO. E1.1