12-508-011DOOR SCHEDULE
M•AIM
rM
MAIL
VMrM
HEIM
IV=
FIN
FM RATMM
S
R MATL
F. M
%A"
W-#D
TF�10LD
8
001 -1
B
STEEL
2) 3' -O'
7' -0"
1 3/4"
PAIN
Q
3
H.M.
PAINT
4/A -5.1
4/A -5.1
8/A -5.1
MIAMI -DADE NOA **
001 -2
B
WOOD
3' -0"
7' -0"
1 3/4"
STAIN
'C' LABEL
1
H.M.
PAINT
3/A -5.1
3/A -5.1
7/A -5.1
1 1/2 PAIR HINGES
002 -1
A
WOOD
3' -O"
7' -0"
1 3/4"
STAIN
LEVER RHODES
1
H.M.
PAINT
3/A -5.1
3/A -5.1
7/A -5.1
1 WALL STOP
003 -1
B
WOOD
3' -O"
7' -0"
1 314"
STAIN
'C' LABEL
1
H.M.
PAINT
3/A -5.1
3/A -5.1
7/A -5.1
1 1/2 PAIR HINGES
003 -2
B
WOOD
3' -0"
7' -0"
1 3/4"
STAIN
* *AS PER MIAMI -DADE NOA
1
H.M.
PAINT
3/A -5.1
3/A -5.1
7/A -5.1
FAS -SEAL
004-1
A
WOOD
3' -0"
7' -0"
1 3/4"
STAIN
1 EA. CLOSER
2
H.M.
PAINT
3/A -5.1
3/A -5.1
6/A -5.1
COLOR: BUFFSTONE RANGE 3
005 -1
A
WOOD
3' -0"
7' -0"
1 3/4"
STAINI
CT -1
2
H.M.
PAINT
3/A -5.1
3/A -5.1
7/A -5.1
006 -1
A
I WOOD
S -0"
7' -O`
1 3/4"
STAIN
DAL -TILE SEMI GLOSS
COLOR: 1452 CYPRESS 6 "X6"
2
H.M.
PAINT
3/A -5.1
3/A -5.1
7/A -5.1
STRAW
"EXTERIOR DOOR MIAMI -DADE N.O.A. #09- 0528.06
APPROVAL DATE: APRIL 14. 2011
EXPIRATION DATE: APRIL 14, 2016
0
In
VARIES 31-on
/ o
/ I
A /
0
1/4" SAFETY GLASS
\� \\ VISION PANEL
(FIRE RATED SAFETY
- -' i r ---- S_ GLAZING WHERE
L ____ APPUCABLE)
V -0" KICK 1' -0" KICK
PLATE PLATE
NO.
DOOR
HARDWARE
JAMB/HEAD DETAIL
DOOR HARDWARE SET
NO. 1 OFFICES AND
EXAM ROOMS
\4�aIII
S
1 1/2 PAIR HINGES
BB1260
5X4
3 HINGES
US26D HAGER FULL MORTISE
1 LOCKSET
D50PD
F82 -1
LEVER RHODES
DESIGN US26D SCHLAGE KEYED LOCK
1 DOOR STOP
FB13
US26D HAGER
Q
V17-1
1 WALL STOP
409
US26D IVES /60W
GLYNN - JOHNSON
_j
3 SILENCERS
GRAY
RUBBER
CLERK
cr_,
1 CLOSER
4041
LCN
PT -1
PT -1
DOOR HARDWARE SET
NO, 2 (TOILET ROOM/
DRESS ROOM)
W
CT -4, T1
1 1/2 PAIR HINGES
BB1260
5 "X4 W
3 HINGES
US26D HAGER FULL MORTISE
1 LOCKSET
D44S
F82 -1
LEVER RHODES
DESIGN US26D SCHLAGE KEYED LOCK
1 DOOR STOP
FB13
US26D HAGER
STYLE: REFRESH UMP #60539
006
1 WALL STOP
409
US26D IVES /60W
GLYNN- JOHNSON
PT -1
3 SILENCERS
PT -1
RUBBER
DOOR HARDWARE SEr
NO. 3 (EXTERIOR DOOR)
1 1/2 PAIR HINGES
5BB1 /3CB1
4 X" X 4
4 HINGES
* *AS PER MIAMI -DADE NOA
1 EA. EXIT DEVICE
SURFACE VERTICAL
ROD - WS98/9927(F) VON DUPRIN
* *AS PER MIAMI -DADE NOA
1 SPUT ASTRAGAL
328
'ZERO'
* *AS PER MIAMI -DADE NOA
1 EA. DOOR SWEEP
FAS -SEAL
AS NOTED
STEELCRAFT
* *AS PER MIAMI -DADE NOA
EATHERSTRIPPING
PS -074 SELF ADHESIVE
STEELCRAFT
* *AS PER MIAMI -DADE NOA
1 EA. CLOSER
CT -4 DAL -TILE - KEYSTONE D147
"X3"
AS NOTED
FINISH: SATIN (HEALTHCARE PAINT)
0
In
VARIES 31-on
/ o
/ I
A /
0
1/4" SAFETY GLASS
\� \\ VISION PANEL
(FIRE RATED SAFETY
- -' i r ---- S_ GLAZING WHERE
L ____ APPUCABLE)
V -0" KICK 1' -0" KICK
PLATE PLATE
"-tl"
NO.
ROOM NAME
FLOOR
JAMB/HEAD DETAIL
CEILING
JAMB/HEAD DETAIL
\4�aIII
S
E
►4�3II
001
HYPERBARIC ROOM
VT -1
RB -1
"-tl"
5 FRAME PROFILES
A5.1 SCALE N.T.S.
FINISH SCHEDULE
NO.
ROOM NAME
FLOOR
BASE
CEILING
REMARKS
N
S
E
W
001
HYPERBARIC ROOM
VT -1
RB -1
PT -1
z
PT -1
PT -1
ACT
Xn
Q
V17-1
RB -1
PT -1
.-
w
_j
ACT
MILLWORK REVEAL
003
CLERK
cr_,
t1
PT -1
PT -1
PT -1
PT -1
ACT
>
W
CT -4, T1
CTB -1
CT -1, CT -2, CT -3
PT -2
CTB -1
Xn
DRESSING ROOM
CA -2
RB -2
PT -1
PT -1
PT -1
r
ACT
5 FRAME PROFILES
A5.1 SCALE N.T.S.
FINISH SCHEDULE
NO.
ROOM NAME
FLOOR
BASE
CEILING
REMARKS
N
S
E
W
001
HYPERBARIC ROOM
VT -1
RB -1
PT -1
PT -1
PT -1
PT -1
ACT
002
TCM ROOM
V17-1
RB -1
PT -1
PT -1
PT -1
PT -1
ACT
MILLWORK REVEAL
003
CLERK
CA -1
RB -2
PT -1
PT -1
PT -1
PT -1
ACT
004
TOILET ROOM
CT -4, T1
CTB -1
CT -1, CT -2, CT -3
PT -2
CTB -1
005
DRESSING ROOM
CA -2
RB -2
PT -1
PT -1
PT -1
PT -1
ACT
STYLE: REFRESH UMP #60539
006
1 H.C. DRESSING ROOM
CA -2
RB-2
PT -1
PT -1
PT -1
PT -1
ACT
FINISH SCHEDULE AND SPECIFICATION
SCALE; N.T.S.
6
A51
VA DI CC
5"
THRESHOLD DETAIL
►�G>/i
7
A_
THRESHOLD DETAIL
SCALE NTS
r
FLORIDA
CODE"
GENERAL NOTES-_
A. REFER TO FINISH SCHEDULE FOR DOOP- ONISk UNIESS-m
OTHERWISE NOTED. = -
B. FULLY GROUT ALL DOOR FRAMES
C. USE DOUBLE (ATTACHED) 20 GPUG - ME fkt STU45 AT JAMBS
OF ALL DOOR OPENINGS IN MET:kt STUD PARTITION. -
D. SEE FLOOR PLAN FOR EXACT DOOR SWING.
E. ALL GLASS AT INTERIOR DOORS TO BE 1/4- CLEAR FULLY
TEMPERED SAFETY GLASS.
F. EXTERIOR DOORS TO BE IMPACT RESISTANT AND HAVE
MIAMI -DADE N.O.A.
G. ALL ACCESSIBLE H.C. TOILET ROOM DOORS TO BE SELF
CLOSING WITH DELAYED ACTION CLOSER.
H. ALL DOORS SHALL BE PROVIDED WITH SELF- CLOSING
HARDWARE.
I. ALL INTERIOR DOORS SHALL BE SOLID WOOD MAPLE FINISH.
J. REFER TO FINISH SCHEDULE FOR HM FRAME FINISH UNLESS
OTHERWISE NOTED.
K. THE INFORMATION INCLUDED IN THIS DRAWING WAS
PROVIDED BY THE INTERIOR DESIGN DEPT. (SUPPORT
SERVICES DEPT.) AT BAPTIST HEALTH SOUTH FLORIDA.
L. BEFORE INSTALLATION OF ANY FINISHES, CONTRACTOR
MUST SHOW SAMPLE AND GET APPROVAL FROM SOUTH
MIAMI HOSPITAL INTERIOR DESIGN DEPARTMENT BEFORE
PROCEEDING WITH INSTALLA1ION OF ANY FLOORING
MATERIAL.
M. PROVIDE VINYL TRANSITION STRIP BETWEEN CARPET AND
VINYL TILE.
N. SEE ELEVATION (THIS SHEET) FOR TYPICAL TOILET ROOM
WALL TILE PATTERN Q THIS DRAWING.
0. DO NOT SUBSTITUTE PAINT MANUFACTURERS.
P. WHEN PAINTING OVER EXISTING COLORED WALL,
CONTRACTOR TO USE A 'KILLS' PRIMER.
NOTES THIS DRAWING
1 4 1 CAULK PERIMETER BOTH SIDES (TYPICAL)
2 HOLLOW METAL FRAME
3 GROUT ALL JAMBS SOLID TYPE M MORTAR
18 GA 3 5/8" DOUBLE STUDS 0 JAMBS (TYPICAL) W/ 1"
X 3" METAL STRAPS 3 PER JAMB
5 5/8" GYPSUM BOARD. REFER TO WALL TYPES
6 JAMB ANCHOR CLIP WELDED TO FRAME & FASTENED TO
STUDS (3 PER JAMB) TYPICAL
7 DOOR. REFER TO DOOR SCHEDULE
8 FRAME ANCHOR CUP WELDED TO DOOR FRAME (3 PER
JAMB TYP.)
9 VCT OR SHEET VINYL - REFER TO FINISH SCHEDULE
10 CARPET TO VCT RUBBER /VINYL THRESHOLD
11 CARPET - REFER TO FINISH SCHEDULE
12 MARBLE SILL WITH BEVELED EDGES (SLOPE TO MATCH
ADA REQUIREMENTS) - REFER TO FINISH SCHEDULE
13 CERAMIC /PORCELAIN FLOOR TILE - REFER TO FINISH
SCHEDULE
14 CONT PERIMETER SEALANT AND BACKER ROD BEFORE
STUCCO /SECONDARY SEALANT AFTER STUCCO (TYP.)
15 V STUCCO ON THE EXTERIOR TO MATCH EXISTING
16 CORNER BEAD
17 HOLLOW METAL FRAME FILLED WITH GROUT
1 g P.T WOOD BLOCKING
1 g INSULATION
20 ALUMINUM THRESHOLD SET IN MASTIC
21 REFER TO FINISH SCHEDULE FOR FLOORING
ARCHITECT:
BERMELLO AJAMIL & PARTNERS, INC.
Architecture Engineering Planning
Interior Design Landscape Architecture
2601 South Bayshore Drive 10th Floor
Miami, Florida 33133
(305) 859 -2050 Fax (305) 860 -3700
LOUIS J. AGUIRRE & ASSOCIATES. P.A.
Consulting Engineers
9150 South Dadeland Blvd. 4 Suite 900
Miami o Florida 33156 " EB0000924
Telephone 305.670.0141
Facsimile 305.670.0144
1M.1 jgapa.com
k
6.5 7.4 $:
PERMIT SET
4/13/2012
REVISIONS:
PROJECT NAME:
SMH- HYPERBARIC CHAMBER
PROJECT ADDRESS:
7400 S.W. 62nd Ave.
South Miami, Florida 33143
KEY PLAN
10
COMM. NO. 40068
SCALE: AS SHOWN
DATE: 04/13/2012
DRAWN: BZ
CHECKED:
CADD FILE: H:INS1i11003- SMH\ARCfR
DRAWING TITLE:
DOORS, SCHEDULES
AND FINISHES
111111R.Jul
FINISH SPECIFICATIONS
FLOORING
BASE
T1 THRESHOLD (SOLID POYMER),
CORIAN RAFFIA
FLOOR GROUT --
MAPAI EPDXY GROUT
RB -1
JOHNSONITE
AS NOTED
#39 IVORY MARFIL
COLOR: 09 CLAY
RB -2
JOHNSONITE
AS NOTED
CA -1 SHAW CARPET
AS NOTED
MILLWORK REVEAL
STYLE: THAT THE TICKET #59389
COLOR: MW09F
COLOR: EW24
CTB -1
DAL -TILE, SEMI -GLOSS
AS NOTED
CA -2 SHAW CARPET
AS NOTED
COLOR: ALMOND 0135
STYLE: REFRESH UMP #60539
6 "X6"
COLOR: SECRET GARDEN #39300
WALL
VT -1 ARMSTRONG
AS NOTED
ANTIQUE WHITE #58111
PT_ 1
SHERWIN WILLAMS
AS NOTED
SW 6141 SOFTER TAN
CT -4 DAL -TILE - KEYSTONE D147
"X3"
AS NOTED
FINISH: SATIN (HEALTHCARE PAINT)
COLOR: BUFFSTONE RANGE 3
CT -1
DAL -TILE, SEMIGLOSS: ALMOND
0135 ALMOND
WALL. GROUT:
GROUT COLOR:
EPDXY
MAPEI # 94
WALL PROTECTION
6 "X6"
STRAW
(8 ") BUMPER GUARD (SURFACE MOUNTED, MOLDED
PLASTIC), C/S GROUP, ACROVYN,
CT -2
DAL -TILE SEMI GLOSS
COLOR: 1452 CYPRESS 6 "X6"
WALL GROUT:
GROUT COLOR:
EPDXY
MAPEI # 94
SCR -64, COLOR: 103 BEIGE, TEXTURE: PEBBLETTE
TEXTURE
STRAW
CG3 -B2
CT -3
DAL TILE, SEMI -GLOSS
WALL GROUT
EPDXY
(3 ") CORNER GUARD, (SURFACE MOUNTED, MOLDED
PLASTIC), C/S GROUP, ACROVYN,
COLOR: 1/261P2 -1452 1 "X6" PENCIL
GROUT COLOR:
MAPEI # 94
SM -20 SHARP NOSE EDGE, COLOR: 103 BEIGE, TEXTURE: PEBBLETTE TEXTURE
LINER CYPRESS
STRAW
MILLWORK
DOOR
FRAMES
PL -1 VERTICAL SURFACE FORMICA GINGER
ROOT AS NOTED
PT -4
SHERWIN WILLIAMS SW 6142
MAPLE 7288 -58
MACADAMIA
AT ALL NEW DOOR
FRAMES.
PL -2 COUNTERTOP WILSONART PL -2D WILSON ART AS NOTED
FINISH: ENAMEL
HEALTH CARE SPECIFICATION
GREEN SOAPSTONE 4885 -38
DOORS
CEILING
LAMBTON DOOR COMPANY
SPECIES: MAPLE
ACT ARMSTRONG ACOUSTICAL CEILING DUNE # 177 �D
CUT. PS
TEGULAR EDGE 9/16" EXPOSED TEE
SUSPEA
GRADE: AA
FINISH: PLS -100
PT-2 SHERWIN WILLAMS
MATCH: B/B BOOK & BALANCE MATCH
SW 6119 ANTIQUE WHITE
FINISH: FLAT (HEALTHCARE PAINT)
FINISH SCHEDULE AND SPECIFICATION
SCALE; N.T.S.
6
A51
VA DI CC
5"
THRESHOLD DETAIL
►�G>/i
7
A_
THRESHOLD DETAIL
SCALE NTS
r
FLORIDA
CODE"
GENERAL NOTES-_
A. REFER TO FINISH SCHEDULE FOR DOOP- ONISk UNIESS-m
OTHERWISE NOTED. = -
B. FULLY GROUT ALL DOOR FRAMES
C. USE DOUBLE (ATTACHED) 20 GPUG - ME fkt STU45 AT JAMBS
OF ALL DOOR OPENINGS IN MET:kt STUD PARTITION. -
D. SEE FLOOR PLAN FOR EXACT DOOR SWING.
E. ALL GLASS AT INTERIOR DOORS TO BE 1/4- CLEAR FULLY
TEMPERED SAFETY GLASS.
F. EXTERIOR DOORS TO BE IMPACT RESISTANT AND HAVE
MIAMI -DADE N.O.A.
G. ALL ACCESSIBLE H.C. TOILET ROOM DOORS TO BE SELF
CLOSING WITH DELAYED ACTION CLOSER.
H. ALL DOORS SHALL BE PROVIDED WITH SELF- CLOSING
HARDWARE.
I. ALL INTERIOR DOORS SHALL BE SOLID WOOD MAPLE FINISH.
J. REFER TO FINISH SCHEDULE FOR HM FRAME FINISH UNLESS
OTHERWISE NOTED.
K. THE INFORMATION INCLUDED IN THIS DRAWING WAS
PROVIDED BY THE INTERIOR DESIGN DEPT. (SUPPORT
SERVICES DEPT.) AT BAPTIST HEALTH SOUTH FLORIDA.
L. BEFORE INSTALLATION OF ANY FINISHES, CONTRACTOR
MUST SHOW SAMPLE AND GET APPROVAL FROM SOUTH
MIAMI HOSPITAL INTERIOR DESIGN DEPARTMENT BEFORE
PROCEEDING WITH INSTALLA1ION OF ANY FLOORING
MATERIAL.
M. PROVIDE VINYL TRANSITION STRIP BETWEEN CARPET AND
VINYL TILE.
N. SEE ELEVATION (THIS SHEET) FOR TYPICAL TOILET ROOM
WALL TILE PATTERN Q THIS DRAWING.
0. DO NOT SUBSTITUTE PAINT MANUFACTURERS.
P. WHEN PAINTING OVER EXISTING COLORED WALL,
CONTRACTOR TO USE A 'KILLS' PRIMER.
NOTES THIS DRAWING
1 4 1 CAULK PERIMETER BOTH SIDES (TYPICAL)
2 HOLLOW METAL FRAME
3 GROUT ALL JAMBS SOLID TYPE M MORTAR
18 GA 3 5/8" DOUBLE STUDS 0 JAMBS (TYPICAL) W/ 1"
X 3" METAL STRAPS 3 PER JAMB
5 5/8" GYPSUM BOARD. REFER TO WALL TYPES
6 JAMB ANCHOR CLIP WELDED TO FRAME & FASTENED TO
STUDS (3 PER JAMB) TYPICAL
7 DOOR. REFER TO DOOR SCHEDULE
8 FRAME ANCHOR CUP WELDED TO DOOR FRAME (3 PER
JAMB TYP.)
9 VCT OR SHEET VINYL - REFER TO FINISH SCHEDULE
10 CARPET TO VCT RUBBER /VINYL THRESHOLD
11 CARPET - REFER TO FINISH SCHEDULE
12 MARBLE SILL WITH BEVELED EDGES (SLOPE TO MATCH
ADA REQUIREMENTS) - REFER TO FINISH SCHEDULE
13 CERAMIC /PORCELAIN FLOOR TILE - REFER TO FINISH
SCHEDULE
14 CONT PERIMETER SEALANT AND BACKER ROD BEFORE
STUCCO /SECONDARY SEALANT AFTER STUCCO (TYP.)
15 V STUCCO ON THE EXTERIOR TO MATCH EXISTING
16 CORNER BEAD
17 HOLLOW METAL FRAME FILLED WITH GROUT
1 g P.T WOOD BLOCKING
1 g INSULATION
20 ALUMINUM THRESHOLD SET IN MASTIC
21 REFER TO FINISH SCHEDULE FOR FLOORING
ARCHITECT:
BERMELLO AJAMIL & PARTNERS, INC.
Architecture Engineering Planning
Interior Design Landscape Architecture
2601 South Bayshore Drive 10th Floor
Miami, Florida 33133
(305) 859 -2050 Fax (305) 860 -3700
LOUIS J. AGUIRRE & ASSOCIATES. P.A.
Consulting Engineers
9150 South Dadeland Blvd. 4 Suite 900
Miami o Florida 33156 " EB0000924
Telephone 305.670.0141
Facsimile 305.670.0144
1M.1 jgapa.com
k
6.5 7.4 $:
PERMIT SET
4/13/2012
REVISIONS:
PROJECT NAME:
SMH- HYPERBARIC CHAMBER
PROJECT ADDRESS:
7400 S.W. 62nd Ave.
South Miami, Florida 33143
KEY PLAN
10
COMM. NO. 40068
SCALE: AS SHOWN
DATE: 04/13/2012
DRAWN: BZ
CHECKED:
CADD FILE: H:INS1i11003- SMH\ARCfR
DRAWING TITLE:
DOORS, SCHEDULES
AND FINISHES
111111R.Jul