Loading...
12-1058-006TrueAlert7 NON —ADDRE S SABLE MULTI — CANDELA AUDIBLE /VISIBLE NOTIFICATION APPLIANCE PRODUCT INFORMATION FEATURES: (ELECTRONIC HORN W /STROBE) WHEN SURFACE MOUNTING USE • CLASS B (STYLE Y) OPERATION REQUIRES CONNECTION RED SKIRT NO. 4905 -9937 (RED) 4" SQUARE x 1 1/2" DEEP BOX TO A COMPATIBLE SMARTSYNC NAC OR TO WHITE SKIRT NO 4905 -9940 (WHITE)) SMARTSYNC CONTROL MODULE (SCM) 4905 -9938 • CLASS A (STYLE Z) OPERATION WHEN CONNECTED TO THE 4905 -9938 SCM OR 41000 SERIES FIRE ALARM CONTROL PANEL NAGS SPECIFICATIONS: • HOUSING DIMENSIONS (INCLUDING LENS) : 5 1/8 "H X 5" W X 2 3/4 "D • TEMPERATURE RANGE: 32' F TO 122' F (0' TO 50' C) • HUMIDITY RANGE: 10% TO 93% NON— CONDENSING AT 100' F (38' C) • TERMINAL BLOCKS FOR 18 AWG TO 12 AWG; TWO WIRES PER ° TERMINAL FOR IN /OUT WIRING. 4905 -9961 OPTIONAL WIRE GUARD (SHOWN HERE FOR REFERENCE ONLY, CAN BE USED ON OTHER MOUNTING OPTIONS) HORN — SOUND OUTPUT CHARACTERISTICS: 2400 TO 3700 H MODULATED AT 120 Hz RATE HORN SOUND OUTPUT RATINGS ® 10 FT. (3m) VOLTAGE 16 VDC STEADY CODED 24 VDC STEADY CODED 33 VDC STEADY CODED SOUND TYPE REVERBERATE CHAMBER UL 464 TEST 86 dBA 82 dBA 88 dBA 84 dBA 90 dBA 86 dBA ANECHOIC CHAMBER 92 dBA 91 dBA 94 dBA 95 dBA 96 dBA 96 dBA IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE ELECTRICAL BOTTOM OF LENS BOX OUTLINE IS EITHER EVEN WITH OR SLIGHTLY ABOVE BOTTOM OF COMPATIBLE BOXES NFPA 72 REQUIRES THAT 80• THE ENTIRE LENS BE NOT MIN. LESS THAN 80• AND NOT GREATER THAN 96' ABOVE THE FINISHED FLOOR. 2975 -9145 BOX FER PLATE CODED VALUES ARE TYPICAL OF THE OUTPUT MEASURED WITH A TEMPORAL CODED OR A MARCH TIME CODED PULSE AND WITH A SOUND LEVEL METER READING ON A "FAST" SETTING. UNDER THE SAME TEST CONDITIONS, CODED — HORN OUTPUT "PEAK" SOUND LEVEL READINGS ARE TYPICALLY 4 dBA HIGHER. FROM A COMPATIBLE + SIMPLEX SMARTSYNC STROBE NAC OR FROM — RATED VOLTAGE RANGE: UL: REGULATED 24VDC PER UL 1971 SMARTSYNC CONTROL —' ULC: 20VDC TO 3OVDC PER ULC S526 —M878 MODULE (SCM) 4905 -9938 — FLASH RATE: 1 Hz — SYNCHRONIZED MODE NAC LOADING: MAXIMUM OF 35 SYNCHRONIZED STROBES PER NAC CIRCUIT. *rl IRRFNT IIRAWC RFFI FCT STRORF FI ASHINh AND HORN ON- HOUSING LETTERING STROBE MODEL NUMBER COLOR COLOR RATING RMS CURRENT 16 VDC 18 VDC 24 VDG 4906-9127 16 VDC 18 VDC c 4906 -9101 RED m 15cd 60 o 30cd m 40 m m c — m 94 m 110ed --21;5 m 3 mA 190 mA - 165 mA 124 mA c MA 67 mA 50 mA 4906 -9103 WHITE 1 RED I 15cd 30cd mA 103 mA 77 mA c m 196 mA 147 mA c F— —795—MA 253 mA 190 mA r7 TERMINALS 3 & 4 ARE NOT USED I n ° o o t SEMI —FLUSH MOUNTING ALTERNATE BACK BOXES 1. 2 GANG 1 1/2" DEEP BOX 2. SINGLE GANG 1 1/2" DEEP BOX TO ADDITIONAL NOTIFICATION APPLIANCE DEVICE OR RETURN TO FACP FOR STYLE Z APPUCATION — —Z IF LAST DEVICE ON CIRCUIT IN A r r + STYLE Y APPLICATION PLACE A 10K 1/2W END —OF LINE RESISTOR I � INTENSITY SELECTION PLUG, ACCESSIBLE ONLY FROM REAR OF HOUSING FACTORY SETTING IS 15cd STROBE INTENSITY VIEWING SLOT 4099 -9002 IDNet DOUBLE ACTION BREAKGLASS STATION SINGLE GANG EXTENSION RING 3/4" 2 1 8� DEEP BOX (RA 0 NO. 231 OR 23: PRODUCT INFORMATION (RACO NO. 773) OR SPECIFICATIONS MOUNTING INSTRUCTIONS: MOUNTING INSTRUCTIONS: SUPPLIED BY CONTRACTOR SINGLE GANG SWITH BO 1. COVER & BACKPLATE COME ASSEMBLED. 1. COVER & BACKPLATE COME ASSEMBLED. 2 1/2" DEEP 2 UNLOCK STATION, DROP COVER FORWARD 2. UNLOCK STATION, DROP COVER FORWARD O (RACO NO. 500) • . POWER &COMMUNICATIONS: IDNet /MAPNET, 1 ADDRESS PER STATION, UP TO 2500 FT. FROM TO EXPOSE MOUNT ;:IG SCREWS. TO EXPOSE MOUNTING SCREWS. ° OD IRE ALARM CONTROL PANEL, UP TO 10,000 FT. TOTAL KNOCKOUTS FOR 3/4" CONDUIT CONTRACTOR o WIRING DISTANCE (INCLUDING T —TAPS) TOP AND BOTTOM OF BOX o • ADDRESS MEANS: DIP SWITCH, 8 POSITION 4\ 0 0 • WIRE CONNECTIONS: SCREW TERMINAL FOR IN /OUT WIRING, FOR #18 TO #14 AWG WIRE O • UL USTED TEMP. RANGE: 32' F TO 120' F (0' C TO 49' C) 00 INTENDED FOR INDOOR OPERATION 0 o • HUMIDITY RANGE: UP TO 93% RH AT 100' F (38' F) • HOUSING COLOR: RED WITH WHITE RAISED LETTERING • MATERIAL' HOUSING AND PULL LEVER ARE LEXAN POLYCARBONATE • PULL LEVER COLOR: WHITE WITH RED RAISED LETTERING • HOUSING DIMENSIONS: 5" H X 3 -3/4" W X 1" D WIRE NOTES: ❑IDNet LINES ARE TO BE #18 AWG TWISTED PAIR (CONSULT RECOMMENDED. SIMPLEX DED BRANCH FOR EXCEPTIONS) © MAXIMUM ALLOWABLE LINE RUN, FROM F.A.C.P. TO FARTHEST DEVICE, NOT TO EXCEED 2500 FEET. © MAXIMUM TOTAL WIRE (INCLUDING ALL T —TAPS) ON CIRCUIT, FROM F.A.C.P. NOT TO EXCEED 10,000 FEET OR .58uF. ® MAXIMUM QUANTITY OF DEVICES PER CIRCUIT: 250. © SEE INSTALLATION INSTRUCTIONS 574 -332. ® TERMINALS 1 AND 2 FOR FIELD WIRING. TERMINALS 3 AND 4 ARE FACTORY WIRING. M IF SHIELD IS PRESENT, IT SHOULD BE CONNECTED TO THE OUTGOING IDNet SHIELD TO PROVIDE A CONTINUOUS SHIELD OVER THE LENGTH OF THE IDNet CHANNEL SHIELD SHOULD BE INSULATED FROM ELECTRICAL BOX. III 2975 -9178 OR 2975 -9022 BOXES AVAILABLE FROM SIMPLEX WIRE MOLD BOX NO. 57447 SUPPLIED BY CONTRACTOR SURFACE MOUNTING 4 11(116" sQUAF 2099 -9819 (BLACK) OR SUPPLIED BY COI 2099 -9820 (BEIGE) FLUSH ADAPTOR AVAILABLE MOUNTING INSTRUCTIONS: FROM SIMPLEX 1. COVER & BACKPLATE COME ASSEMBLED. 2. UNLOCK STATION, DROP COVER FORWARD p� TO EXPOSE MOUNTING SCREWS. —, /f h FLUSH MOUNTING SEMI —FLUSH MOUNTING DEEP BOX �I► NOTE: BOX MUST BE RECESSED INTO WALL 11" TO 1 1/8'. CUTOUT MUST BE A MINIMUM 6" HIGH BY 5" WIDE S�S SI—S — _ — — — R + IDNet IDNet UNES TO - B — IDNet NEXT DEVICE OR RETURN OPTIONAL TO FACP FOR STYLE 'PULL STATION I I PULL STATION SHIELD 6 OR 7 OPERATION WIRE RBLEGEND: B=ED m ®I I I IDNet LINES mm® I + OPTIONAL SHIELD IDNet IDNet FROM PREVIOUS DEVICE OR F.A.C.P. \ \SCWM1 \DRAFIINC\00- 2003\S011IH YW� FIOSPIGL (WISIER 5TE) \51AH ACC HiPER84RIC CtWIBQt 965293212 REV 00 \SAIH ACC FMPERBIRIC CFIGI�R Z�DWCiuly 24, 2012 DATE PLOTTID: July 25, 2012 DATE SAVED: July 23, 2012 G•L�1��II =1�1 ^ u 4099 -9002 TrueAlertm NON — ADDRESSABLE MULTI — CANDELA VISIBLE NOTIFICATION APPLIANCE PRODUCT INFORMATION WHEN SURFACE MOUNTING USE (WALL MOUNT) RED SKIRT NO. 4905 -9937 OR 4" SQUARE x 1 -1/2" DEEP BOX FEATURES: WHITE SKIRT NO. 4905 -9940 / • UL LISTED TO STANDARD 1971 4905 -9931 ADAPTER PLATE --\ — 2975 -9145 BOX l\ • ADA COMPATIBLE SYNCHRONIZATION FLASH RATE MODE FOR USE WITH: • SEPARATE STROBE SYNCHRONIZATION MODULES THAT ARE AVAILABLE FOR CLASS B OR CLASS A OPERATION • SEPARATE SMARTSYNC CONTROL MODULES (SCMs) THAT PROVIDE CLASS B OR CLASS A OUTPUT FROM CONVENTIONAL NAC INPUTS SPECIFICATIONS: • HOUSING DIMENSIONS: 5 -1/8" H X 5" W X 2 -3/4" D (130mm X 127mm X 70mm) • TEMPERATURE RANGE: 32'F TO 122'F (0 TO 50C) • HUMIDITY RANGE: 10% TO 93% NON— CONDENSING AT 109F (39C) •TERMINAL BLOCKS FOR 18AWG TO 12AWG; TWO WIRES PER TERMINAL FOR IN /OUT WIRING. WIRING: 1. NOTIFICATION APPLIANCES ARE RATED PER INDIVIDUAL NAMEPLATE LABEL 2. MAINTAIN CORRECT POLARITY ON TERMINAL CONNECTIONS. DO NOT LOOP WIRES UNDER TERMINALS. 3. ALL NAC WIRING CONNECTIONS ARE SUPERVISED AND POWER— UMITED. 4. SEE INSTALLATION INSTRUCTIONS (579 -548) FOR ADDITIONAL INFORMATION. STROBE: • RATED VOLTAGE RANGE: UL USTED: 16 VDC TO 33 VDC PER UL 1971 ULC USTED: 20 VDC TO 30 VDC PER ULC S526 —M878 • FLASH RATE: 1 Hz • SYNCHRONIZED MODE NAC LOADING: MAXIMUM OF 35 SYNCHRONIZED STROBES PER NAC CIRCUIT. #CI IRRFNT nRAWS RFFI FCT STRORF FI ASHING MODEL NUMBER HOUSING I COLOR LETTERING COLOR STROBE RATING w W 16 VDC 18 VDC 24 VDC 4906 -9101 RED WHIT 15cd 60 o m 40 m 30cd 94 mA 84 mA 63 mA 75cd 186 mA 165 mA 124 mA 110cd 252 mA 224 mA 168 mA 4906 -9103 WHITE 1 RED I 15cd 1 60 mA 53 mA 40 mA a o Q 30cd 1 94 mA 84 mA 1 63 mA 75cd 1 186 mA 165 mA 1 124 mA 110cd 1 252 mA 1 224 mA 1 168 mA T 'jv_T_'iCA LS IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE ELECTRICAL BOTTOM OF LENS BOX OUTLINE IS EITHER EVEN WITH OR SLIGHTLY ABOVE BOTTOM OF —�— COMPATIBLE BOXES NFPA 72 REQUIRES THAT 80' THE ENTIRE LENS BE NOT MIN. LESS THAN 80' AND NOT GREATER THAN 96" ABOVE THE FINISHED FLOOR. ON ALL FOUR SIDES. FROM A COMPATIBLE SIMPLEX SMARTSYNC NAC OR FROM SMARTSYNC CONTROL MODULE (SCM) 4905 -9938 OR SIMPLEX 4905 -9914 OR 9922 SYNC CUBE WIRE FOR N BE )NTING F;ERMINALS 3 & 4 ARE NOT USED 1 VIII a �t • ALTERNATE BACK BOXES 1. 2 GANG 1 -1/2" DEEP BOX 2. SINGLE GANG 1 -1/2" DEEP BOX SEMI —FLUSH MOUNTING TO ADDITIONAL NOTIFICATION APPUANCE DEVICE OR RETURN TO FACP FOR STYLE Z APPUCATION IF LAST DEVICE ON CIRCUIT IN A — +t STYLE Y APPLICATION PLACE A 10K 1/2W END —OF LINE RESISTOR INTENSITY SELECTION PLUG, ACCESSIBLE ONLY FROM REAR OF HOUSING; FACTORY SETTING IS 15cd STROBE INTENSITY VIEWING SLOT VRAMI DARE CO. FIR( Dr PAP,=1 - 'C o6 y� 2 �-. �i , FL OR1�P,,•� o . ,'1 Y «s, Ott � n'Iv •. , 4.1�, V.;, Y ` .p. •"r w W zQ C4 o w ma: �1 Q I C) aN Z N C Vic) a o Q W_j �_ Lo 2 -�v ~ CD 20)0)) ` U) O � - =Q w IL d LL cl) i.' U Q z fn J im a., ww > zw 2w o �N V � �a z 0 a z 0 a U p 0 w 0 w z U) o_ U o U o: o ILL 0 w o: m U U w N V o � 0 z 0 - r` 111 ° t- 11 w °? ° Q z ¢W 5 o ¢i ° �z awm oao w v w ��o LL w 0 F N ® w `o N LL U n f w F- H U O a Q w z w U) u- Y U w w t LL N T o J w U z o z W z r z z J O p z cO 0 V L) f:• W F- z z Ww U_ w m to U D: w_ ¢ ' U a� U of z •� W _ `L cd 0 w Fi W (7 J < r oW0'_ o = j ?� ! (� z ,—; w 0 U z Q 1- U Q J a -+� U] w z ¢ o �—I o � U co z z Z U �r__q 2~ J � 0 z 20 Q uwi o .� �•�� o 0 W a z0 o C/) (L 9 O w U b z w � o LL o! �o z w 0 x COD z > z d 0 z 0 0 p aJa az P.1 �In oaa �o DRAWN BY: DATE: CCRJR 7/24/12 DESIGNED BY: DATE: CCRJR 7124/12 APPROVED BY: DATE: PROJECT NUMBER: 263 - 410034 / 965293212 SHEET TITLE/ PATH: \ \Sgmiami 1 \D RAFTING \00 - 2003 \SOUTH MIAMI HOSPITAL (MASTER SITE) \SMH ACC HYPERBARIC CHAMBER 965293212 REV 00 SHEET NUMBER: TYP SIZE 0 (24'x78') ,'1 Y «s, Ott � n'Iv •. , 4.1�, V.;, Y ` .p. •"r