Loading...
12-07-003M ETAL PIPE OR CONDUIT PLUMBING LEGEND SYMBOL DESCRIPTION 2. SANITARY PIPE PIPE @ 1/4" - - - - - -- EXIST. SANITARY PIPE - - - - - - - VENT LINE - COLD WATER LINE -- HOT WATER LINE CTG CLEAN -OUT TO GRADE WCO � I 0-ii WCO WALL CLEAN -OUT ' BALANCING VALVE ® FD FLOOR DRAIN JILVTR VENT THRU ROOF CD CONDENSATE DRAINAGE LINE -♦]o- GATE VALVE • F.EX FIRE EXTINGUISHER ON WALL BRACKET HB -I D HOSE BIBB W/TAMPER VACUUM BREAKER FEC FIRE EXTINGUISHER IN CABINET 2 PIPE FLOOR PENETRATION VB VACUUM BREAKER VIV VALVE IN VERTICAL VTR VENT THRU ROOF AFF ABOVE FINISHED FLOOR LEVEL 0- FLOOR CLEAN OUT PT PRESS. & TEMP. RELIEF LINE 1- 1/2 " @1 /4 " /FT. GAS PIPE �-C- WATER HAMMER ARRESTOR GAS COCK VALVE CONSTRUCTION GENERAL NOTES: 1., RUN 1-1/2" PIPE ® 1/4" FT. FIXTURE ARM 2. RUN 2" PIPE @ 1/4" FT. 3. RUN 3" PIPE 0 1/8" FT. 4. RUN 4" PIPE @ 1/8" FT. 5. PROVIDE CLEANOUT AT BASE OF EACH SOIL OF AND WASTE STACK. 1 " 6. INSTALL 1 /2 "CW AT RIGHT SIDE OF FIXTURES. INSTALLATION PROVIDE AIR CHAMBER. TUB 7. INSTALL 1 /2 "HW AT LEFT SIDE OF FIXTURES. PROVIDE AIR CHAMBER. 8, FLOOR DRAINS MUST BE PLACED WHERE THEY NOT INTERFERE WITH WEEL CHAIR TRAFFIC. FILL GAP COMPLETELY AROUND PIPE WITH CP -25 S /L/ CAULK (SEE NOTES 3 -5) 1 2 3 OR 4 J DAMMING MATERIAL: HOUR FIRE RATED (FIBERGLASS •INSULATION, CONCRETE FLOOR Lj BACKER ROD OR MINERAL SLAB WOOL) ENOUGH TO SUPPORT WEIGHT OF CP -25 S/L CAULK SECTION VIEW (SLAB) 1, 2, 3 OR 4 HOUR FIRE RATED DAMMING BLOCK WALL OR MATERIAL------------ SOLID CONCRETE WALL (SEE NOTE 1) PIPE OR CONDUIT CP -25 N/S CAULK BOTH SIDES OF WALL (SEE NOTE) SECTION VIEW (WALL) PIPE PENETRATION NTS 11 NOTES: WATER HAMMER ARRESTER SCHEDULE MARK * P.D.I. SIZE CONN. SIZE AO A ( 1 - 11 F.U.) 1/2" OB (12 - 32 F.U.) 3/4" OC (33 - 60 F.U.) 1 " OD (61 - 11.3 F.U.) 1 OE (114 - 154 F.U.) 1" OF (155 - 330 F.U.) 1 " * PLUMBING AND DRAINAGE INSTITUTE STANDARD WH -201 PLUMBING GENERAL NOTES: 1. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS AND EQUIPMENT NECESSARY FOR THE INSTAUAT10N OF A COMPLETE PLUMBING SYSTEM IN ACCORDANCE WITH THESE DRAWINGS, THE APPLICABLE EDITION OF THE FLORIDA BUILDING CODE 2001, AND ALL OTHER APPLICABLE STATE, COUNTY AND LOCAL CODES AND ORDINANCES. 2. THE CONTRACTOR SHALL PAY ALL COSTS OF PERMIT, INSPECTIONS AND ALL OTHER COSTS INCIDENTAL TO THE COMPLETION AND TESTING OF THIS WORK. UPON FINAL ACCEPTANCE, A CERTIFICATE FROM THE LOCAL INSPECTION AUTHORITY SHALL BE FURNISHED TO THE OWNER. 3. ALL MATERIALS AND EQUIPMENTS SHALL BE NEW, OF U.S. MANUFACTURER AND OF GOOD QUALITY OF RESPECTIVE KIND AND GRADE, AND MUST BE FURNISHED SO AS TO PREVENT ANY DELAY IN THE PROGRESS OF THE WORK. ALL WORK THROUGHOUT SHALL BE PERFORMED IN A WORKMAN- LIKE MANNER BY SUFFICIENT NUMBER OF SKILLED WORKMEN. 4. CONTRACTOR SHALL VISIT THE SITE AND REVIEW ALL PERTINENT UTILITY DRAWINGS TO FAMILIARIZE HIMSELF WITH THE LOCATION OF ALL EXISTING AND /OR PROPOSED UTILITY STUB OUTS, PIPING, EQUIPMENT, ETC., AND MAKE DUE ALLOWANCES FOR ANY CONDITION AFFECTING HIS WORK. 5. ALL UNDERGROUND SANITARY & STORM DRAINAGE PIPING AND FITTINGS SHALL BE PVC -DWV (ASTM D- 2662/D- 3034). 6. ALL ABOVE GROUND SANITARY & STORM DRAINAGE BRANCH & VENT PIPES AND FITTINGS SHALL BE PVC -DWV (ASTM D- 2662/D- 3034). 7. ALL UNDERGROUND WATER PIPING SHALL BE COPPER TYPE "K" (ASTM B -306). ALL ABOVE GROUND PIPING SHALL BE COPPER TYPE (ASTM (ASTM B -306). 8. ALL HOT WATER PRESSURE AND TEMPERATURE RELIEF PIPING SHALL BE COPPER TYPE "K" (ASTM B -306). 9. ALL AIR CONDITIONING CONDENSATE DRAINAGE PIPING SHALL BE SCH. 40 PVC (ASTM D- 2662), EXCEPT WHEN INSTALLED IN RETURN AIR PLENUM WHERE COPPER TYPE "DWV" OR EQUIVALENT MUST BE USED. 10. ALL PLUMBING FIXTURES SHALL BE PROVIDED WITH ALL NECESSARY ACCESSORIES SUCH AS STOP VALVES, 'P" TRAPS, SUPPORTS, P & T VALVES, ETC., AS REQUIRED. ALL EXPOSED PIPING AT FIXTURES AND EQUIPMENT SHALL BE CHROME PLATED BRASS PIPE OR TUBE. PROVIDE SHUT OFF VALVES AND UNIONS TO ALL FIXTURES, ETC., REQUIRING WATER SUPPLY. PROVIDE DIELECTRIC COUPLINGS AS REQUIRED. FOR ALL COPPER PIPING CONTRACTOR MUST USE 95/5 SOLDER. PROVIDE WATER HAMMER ARRESTOR TO EACH FIXTURE AS REQUIRED. 11. PROVIDE CLIANOUTS (WITH CHROME PLATED WALL OR FLOOR ACCESS FRAMES AND COVERS AS REQUIRED) AT THE BASE OF ALL WASTE AND /OR VENT STACKS. PROVIDE PITCH PANS & LEADS FLASHING FOR ALL SANITARY SYSTEM VENTS. 12. ALL HORIZONTAL WASTE PIPING SHALL BE SLOPPED AT 1/8 PER FOOT, UNLESS OTHERWISE NOTED. 13 CONTRACTOR SHALL VERIFY SLOPE AND DEPTHS AND LOCATIONS OF CONNECTION POINTS TO EXISTING PRESSURE OR DRAINAGE LINES BEFORE STARTING WORK. 14 E.W.C. SHALL BE INSTALLED BEFORE TENANT OBTAINS HIS OCCUPATIONAL LICENSE.- PLUMBING CONTRACTOR TO PROVIDE ROUGH -IN FOR FUTURE INSTALLATION.- (TYPICAL AT ALL BAYS) PLUMBING FIXTURE CONNECTION SCHEDULE No. DESCRIPTION DRAIN WATER RATING 0 & SLOPE REMARKS FU COLD HOT WC WATER CLOSET 4" 1/2" N/A 3 " &4 " ®1 /8 " /FT. HOURS 4 L LAVATORY 1-1/2" 1/2" 1/2" 1-1/2-@1/4"/FT. INSTALLATION 2 T TUB 1-1/2" 1/2" 1/2" 1-1/2"@1/4"/FF. 2 SH SHOWER 2" 1/2" 1/2" 2 " ®1 /4 " /FT. 2 SK KITCHEN SINK 1 -1/2" 1/2" 1/2" 1- 1/2 " @1 /4 " /FT. 2 WM WASHING MACHINE 1 -1/2" 1/2" 1/2" 1- 1/2 " @1 /4 " /FT. 4 USE CP -25 S/L SELF - LEVELING CAULK ON HORIZONTAL SURFACES WHEN FILLING GAPS FROM ABOVE THE PENETRATION. USE CP -25 N/S NO SAG CAULK ON VERTICAL SURFACES AND ON HORIZONTAL SURFACES WHEN FILLING GAPS FROM BELOW NOTES: 1. FOR SOLID CONCRETE WALLS, CENTER CP -25 N/S CAULK WITHIN WALL WITH DAMMING MATERIAL ON ONE SIDE 2. RECOMMENDATIONS BASED ON PRODUCT PERFORMANCE PER ASTM E -814 (UL -1479) FIRE TEST AND UL CLASSIFICATION FIRE STOP SYSTEM 49 3. WET INSTALLED DEPTH OF CP -25 CAULKS DEPENDS ON TYPE AND SIZE OF PIPE AND DESIRED RATING WET PIPE FIRE DEPTH SIZE RATING 1/2" MAX 8" 1 -2 13 mm) (203mm) HOURS 1 " MAX 8" 3 -4 (25mm) (203mm) HOURS 4. UP TO 40% SHRINKAGE OF CP -25 N/S OR S/L CAULK IS ACCEPTABLE AFTER INITIAL WET DEPTH INSTALLATION 5. MAXIMUM ANNULAR SPACE TO BE FILLED IS 2 1/2" (64mm) FIRESTOP DETAIL g+ LL AZWNALI YAVtMtNI C.L STREET PLUMBING SITE PLAN SCALE 1/32" SCOPE OF WORK INTERIOR RENOVATION TO CONVERT EXISTING BATHROOM INTO TWO SMALL BATHROOMS AND TO CONVERT EXISTING LAUNDRY ROOM INTO A BATHROOM AND A LAUNDRY ROOM LAUNDRY) REVISIONS: BY CONTRACTOR SHALL VERIFY ALL DIMENSIONS AT SITE SHALL ANY DISCREPANCY IS FOUND, SWILL STOP THE WORK AND NOTIFY THE ARCHITECT/ENGINEER BEFORE PROCEEDING WITH THE WORK. CONTRACTOR SHALL DETERMINE LOCATION OF ANY AND ALL EXISTING SUBTERRANEAN UTILITIES OR CONSTRUCTION IN AREA OF PROPOSED NEW WORK PRIOR TO COMMEN- CEMENT OF NEW WORK IN ORDER TO AVOID DAMAGE TO SAID EXISTING UTILITIES OR CONSTRUCTION These drawings and copies thereof fumished z the Architect are his property, they are t to be used on other work and are to be returned upon demand at the completion of work. If this drawing or any port thereof in used in any manner without the consent of the Architect, the user thereof becomes indebted of the Architect for full commission F-�-1 � A .) tD .• � I � `..J CID M"•�1 co U a 0 Cq °o �w� 0 U .o Q) 0 cc Q V) U rd Cd �yw E" f ..7 � Cd w M o4 1 Cq U P. W Q 0 mo C L ��ED DATE e o 12 -14 -2011 O O W z DRAWN � ° I CDR > a 3132 SHEET � o W 2 SHEETS -. z z o N 0 DATE Cl) � 12 -14 -2011 O O W z DRAWN � ° I CDR > a 3132 SHEET � o W 2 SHEETS -. o N 0 O N W o o� O z Q z o z T Er W 0 ::j z W r7 O LI- Q z 0 J Oa_j LL_ W I_ Q�� >u.Q z 0 W LLI N CN WZwN W z Q M� W O� W +, C° � v W J z 0 NLd z DATE 12 -14 -2011 SCALE AS SHOWN DRAWN CDR JOB 3132 SHEET P -1 OF 2 SHEETS