09-696-014PLUMBING GENERAL NOTES 1. not used 2. THE ENGINEER SHALL BE THE FINAL INTERPRETER OF THE WORK PROVIDED UNDER THE ENGINEER'S CONTRACT WITH THE ARCHITECT. 3. ANY COST ESTIMATION FOR THIS WORK SHALL BE BASED ON THE BUILDING DEPARTMENT APPROVED DOCUMENTS. 4. ANY AND ALL INTENDED CHANGES TO THE PLANS SHALL FIRST BE COMMUNICATED TO THE ARCHITECT IN WRITTEN FORM USING CHANGE ORDER FORMAT. CHANGE ORDERS SHALL BE INITIATED BY THE OWNER ONLY. 4.1 EQUIPMENT SPECIFIED SHALL BE ADHERED TO. HOWEVER, OWNER HAS THE FINAL DECISION ON THE TYPE AND QUALITY OF EQUIPMENT TO BE SUPLLIED. CONTRACTOR SHALL OBTAIN WRITTEN PERMISSION FROM THE OWNER PRIOR TO PURCHASING SUBSTITUTING EQUIPMENT. CONTRACTOR SHALL BEAR THE COST OF ALL ENGINEERING WORK RELATED TO SUBSTfTUDED EQUIPMENT. 5. PRIOR TO COMMENCEMENT OF WORK, VERIFY MEASUREMENTS AT BUILDING SITE. SUBMIT DESCREPANCIES AND DIFFERENCES TO ARCHITECT /ENGINEER FOR CONSIDERATION AND DECISION BEFORE PROCEEDING. 6. PROVIDE ACCURATE LAYOUT, GRADES AND ELEVATIONS, SET SLEEVES AND OPENINGS IN AMPLE TIME, TAKE PROPER PRECAUTIONS TO PROTECT WORK AND EQUIPMENT FROM DAMAGE. 7. DO ALL TRENCHING, EXCAVATING AND BACKFILLING NECESSARY TO ACCOMODATE THE WORK UNDER THIS DIVISION. TRENCH WIDTHS TO BE ADEQUATE TO PERMIT INSTALLATION ALLOWING A MINIMUM OF 8' CLEARANCE ON EACH SIDE OF PIPE. BOTTOM OF TRENCH TO BE TAMPERED FIRM AND EVENLY GRADED TO PROVIDE SPECIFIED PITCH. SHEATH AND BRACE TRENCHES AND EXCAVATIONS. AFTER TESTING AND INSPECTION, BACKFILL WITH CLEAN EARTH. BACKFILLING AND REMOVAL OF ANY SHEATHING AND BRACING TO BE DONE WITHOUT DISTURBING INSTALLED PIPING. 8. EQUIPMENT SCHEDULES ON THE DRAWINGS WERE USED TO ARRIVE AT SPACE AND SERVICE REQUIREMENTS. 9. ANY SUBSTITUTE EQUIPMENT MUST BE EQUAL IN ALL RESPECTS AND WILL BE ALLOWED ONLY UPON WRITTEN APPROVAL BY ENGINEER PRIOR TO SUBMISSION OF BIDS. 10. SHOP DRAWINGS TO BE SUBMITTED FOR THE FOLLOWING ITEMS: DRAINAGE SPECIALITIES, FIRE PROTECTION EQUIPMENT, PLUMBING FIXTURES, PRESSURE CONTROL SYSTEMS, VALVES, VIBRATION ISOLATION EQUIPMENT. 11. DRAWINGS, ARE APPROXIMATE ONLY AND ARE UNDERSTOOD TO BE SUBJECT TO SUCH REVISIONS AS MAY PROVE NECESSARY OR DESIRABLE AT THE TIME THE WORK IS INSTALLED. EACH CONTRACTOR WILL BE REQUIRED TO INSTALL HIS WORK WITH RELATION TO EXISTING BUILDING CONDITIONS AND WILL BE ENTIRELY RESPONSIBLE FOR FINISH ELEVATIONS, ETC. EXTERIOR UTILITIES SHOWN ON DRAWINGS ARE DIAGRAMMATIC ONLY, THEIR EXACT LOCATIONS, DEPTHS AND INVERT ELEVATIONS ARE AS REQUIRED FOR PROPER FLOW AND COORDINATION WITH OTHER TRADES (REFER TO CIVIL ENGINEER PLANS). 12. DRAWING SHOW ARRANGEMENT OF PIPING AND EQUIPMENT. SHOULD LOCAL CONDITIONS NECESSITATE ANY REARRANGMENT, OR IF THE PIPING CAN BE INSTALLED TO BETTER ADVANTAGE IN A DIFFERENT MANAGER, THE CONTRACTOR SHALL BEFORE PROCEEDING WITH WORK, SUBMIT 2 COPIES OF DRAWINGS OF PROPOSED ARRANGEMENT FOR ENGINEER TO REVIEW. 13. IF CONTRACTOR PROPOSED TO INSTALL EQUIPMENT. INCLUDING PIPING REQUIRING SPACE CONDITIONS OTHER THAN THOSE SHOWN, OR TO REARRANGE EQUIPMENTS, HE SHALL ASSUME FULL RESPONSIBILITY FOR REARRANGEMENT OF SPACE AND SHALL HAVE ARCHITECT REVIEW CHANGES BEFORE PROCEEDING WITH THE WORK. REQUEST FOR SUCH CHANGES SHALL BE ACCOMPNIED BY SHOP DRAWINGS OF SPACE IN QUESTION. 14. EACH CONTRACTOR IS RESPONSIBLE FOR THE PROPER LOCATION AND SIZE OF SLOTS, HOLES OR OPENINGS IN BUILDING STRUCTURE PERTAINING TO HIS WORK AND FOR CORRECT LOCATION OF PIPE SLEEVES. 15. EACH CONTRACTOR SHALL SO HARMONIZE HIS WORK WITH THAT OF THE SEVERAL OTHER TRADES SO THAT IT MAY BE INSTAALLED IN A MOST DIRECT AND WORKMANLIKE MANNER WITHOUT HINDERING OR HANDICAPPING OTHER TRADES. PIPING INTERFERENCES SHALL BE HANDLED BY GIVING PRECEDENCE TO PIPELINES WHICH REQUIRE A STATED GRADE FOR PROPER OPERATION. SEWER LINES SHALL TAKE PRECEDENCE OVER WATER LINES REQUIRING STATED GRADE FOR THEIR PROPER OPERATIONS SHALL HAVE PRECEDENCE OVER ELECTRICAL CONDUIT AND DUCTWORK. 16. UNLESS SEPIAS OF THE DRAWINGS ARE TO BE FURNISHED BY THE ARCHITECT /ENGINEER FOR PREPARATION OF RECORD DRAWINGS. FURNISH ARCHITECT /ENGINEER WITH 2 SETS OF ACCURATELY MARKED COPIES OF THE DRAWINGS, INDICATING ALL CHANGES FROM ORIGINALS AS INSTALLED. 17. FURNISH OWNER WITH ALL GUARANTEES FOR EQUIPMENT OR MATERIALS EXTENDING BEYOND THE GUARANTEE PERIOD SPECIFIED IN THE GENERAL CONDITIONS OF THESE SPECIFICATIONS. 18. PLUMBING SYSTEMS SHALL BE PROVIDED COMPLETE. SHOULD A SYSTEM OR ANY PART THEREOF FAIL TO MEET PERFORMANCE REQUIREMENTS, NECESSARY REPLACEMENTS, ALTERATIONS OR REPAIRS AS REQUIRED BY THE ARCHITECTURE /ENGINEER, SHALL BE MADE TO BRING PERFORMANCE UP TO SPECIFIED REQUIREMEMTS AND ALL BUILDING CONSTRUCTION AND FINISHES DAMAGED OR MARRED BY SUCH REPLACEMENTS, ALTERATIONS OR REPAIRS SHALL BE RESTORED TO PRIOR CONDITION AT NO ADDITIONAL COST TO OWNER. 19. PLUMBING CONTRACTOR SHALL INCLUDE IN HIS BID, PROVISION FOR PROVIDING TEMPORARY WATER FOR USE DURING CONSTRUCTION AS REQUIRED. 20. SUB - CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGES TO THE WORK OF OTHER SUB - CONTRACTORS, OR TO THE BUILDING, OR TO ITS CONTENTS. PEOPLE, ETC.; CAUSED BY LEAKS IN ANY OF THE EQUIPMENT, OR MATERIAL FAILURES. OR DISCONNECTED PIPES, FITTINGS OR BY OVERFLOWS, AND SHALL MAKE AT HIS OWN EXPENSE, ALL REPAIRS TO MATERIALS AND EQUIPMENT SO DAMAGED. 21. ALL WORK, EQUIPMENT AND MATERIALS SHALL BE PROTECTED AT ALL TIMES TO PREVENT OBSTRUCTION, DAMAGE, OR BREAKAGE. ALL PIPE OPENINGS SHALL BE CLOSED WITH CAPS OR PLUGS. 22. PLUMBING FIXTURES SHALL BE TESTED FOR PROPER OPERATION AND ALL FLUSH VALVES ADJUSTED. 23. A CLEANOUT SHALL BE PROVIDED AT THE BASE OF EACH SOIL AND WASTE PIPE. 24. A MINIMUM PITCH OF ALL HORIZONTAL BRANCHES AND SEWER LINES SHALL BE 1/4- PER LINEAL FOOT FOR 2- AND SMALLER PIPE SIZES AND 1/8' PER FT. MIN. FOR 3- AND LARGER PIPE SIZES. 25. ALL UNDERGROUND PIPING SHALL BE COPPER TYPE L ALL OTHER WATER PIPING SHALL BE COPPER TYPE M. 26. IN GENERAL ALL WORK OF THIS TRADE MUST COMPLY WITH THE FLORIDA PLUMBING BUILDING CODE AND ALL OTHER CODES IN EFFECT. 27. PROVIDE SAFEWASTE FOR AIR CONDITIONING UNIT CONDENSATE WITH TRAP. 28. PROVIDE PAN DRAINS TO BUILDING EXTERIOR 6' ABOVE GRADE TURNED DOWN (EACH SEPARATEDLY). 29. ALL HOSE BIBBS SHALL BE PROVIDED WITH VACUUM BREAKERS (WATTS 8A) AND SHUT OFF VALVE. 30. ALL OUTSIDE CLEANOUT SHALL BE BROUGHT TO GRADE WITH COVER. 31. PROVIDE CLEANOUT EVERY 75 FEET INSIDE BUILDING. 32. WHERE PERMITTED BY CODE AN IN APPROPRIATELY RATED CHASES AND AS APPROVED PRIOR TO SIGNING OF THIS SUBCONTRACT BY OWNER AND ENGINEER, PVC PIPE, DWV PIPE AND FITTINGS ARE ACCEPTED. 33. INSULATE ALL HOT & COLD WATER CONNECTIONS AT WATER HEATERS AND UP TO 8 FT. THEREAFTER WITH 1 IN. THICK SELF - SEALING TYPE INSULATION (R -4.2 MIN.) 34. APPLY A WATER PRESSURE TEST TO ALL PARTS OF THE WATER SUPPLY AND DRAINAGE SYSTEMS BEFORE THE PIPING IS CONCEALED AND BEFORE THE FIXTURES AND EQUIPMENT ARE CONNECTED. FOR THE WATER SYSTEM USE A HYDRO- STATIC PRESSURE OF NOT LESS THAN 150 PSIG OR 1.25 TIMES THE SYSTEM WORKING PRESSURE, APPLIED TO THE SYSTEM FOR A PERIOD OF 4 HOURS. THERE SHALL BE NO LEAKS AT ANY POINT IN THE SYSTEM AT THIS PRESSURE. FOR THE DRAINAGE SYSTEM USE NOT LESS THAN 10 FT. OF HYDROSTATIC HEAD. LEAVE THE WATER IN THE SYSTEM FOR NOT LESS THAN 30 MINUTES, AFTER WHICH TIME NO LEAKS AT ANY POINT OR LOWERING OF THE WATER LEVEL AT THE OVERFLOW SHALL BE VISIBLE. LEAVE CONCEALED WORK UNCOVERED UNTIL REQUIRE TESTS HAVE BEEN COMPLETED. MAKE REPAIRS OF DEFECTS THAT ARE DISCOVERED WITH NEW MATERIALS. CAULKING OF SCREW JOINTS, CRACKS OR HOLES WILL NOT BE ACCEPTED. REPEAT TESTS AFTER DEFECTS HAVE BEEN ELIMINATED. 35. PROVIDE DIELECTRIC FITTINGS WHEN JOINING DISSIMILAR METALS. ARER STpR Q A ��ER JI - I , 50V d8 pv gr. �p W/5 r exec U) 3 fo Or st 5 1000, - 1/2- BACK FLOW '_PREVENTOR AIN SOV 3/4" HB W /SOV & VB SEE SITE PLAN FO CONTINUATION. L� WATER RISER P -1 NTS 4 ., r