GENERAL PLUMBING NOTE
1. A. ALL WORK SHALL BE DONE in accordance with }lorida
Building Code and with all applicable regulations.
B. DRAWINGS: Refer to all drawings for coordinationthe
plumbing work.
C. ARRANGE AND PAY for all permits, licenses, inspins
and tests. Obtain the required certificates and ent
to owner.
D. GUARANTEE: The completed installation shall be 1
guaranteed against defective materials and /or imer
workmanship for a minimum of one year for mat and
labor.
E. ALL HORIZONTAL SANITARY PIPING shall slope at linch
per foot minimum for 3" and larger and at 1/4 ")e
for 2 1/2" pipes and smaller.
F. ALL materials shall be new, free of defects and cetly
labeled with their appropriate listing agency.
2. SHOP DRAWINGS: Contractor shall submit for approval,hin
30 days of signing contract, a minimum of five copiesfully
descriptive literature, including but not limited to: wate
heaters, and plumbing fixtures. No work shall proceed thout
the approval of these submittals.
3. PLUMBING FIXTURES: Fixtures shall be as selected by or
and shall be furnished and installed by this contractor.ixtures
shall be complete with drains, traps, supplies and any er
accessory required. Fixtures and faucets shall comply H the
FBC Water saving standards.
4. MATERIALS:
A. PIPING:
a. Soil, waste and vent, and storm: Sanitary pipe,'C, DWV,
Schedule 40 under ground, and above ground.
All no HUB connections shall be with cast iron oling.
All piping in return plenums shall be cast iron.
b. Domestic water: CPVC pipe and fittings.
c. Domestic water supply assembly. Chrome finish Ing
with angle shut off valves in exposed areas.
d. P & T Relief lines: CPVC pipe and fittings
e. Drain Pan lines: DWV PVC pipe and fittings.
f. Insulated all hot water and condensate drain pipin5
5. PIPING TEST AND DISINFECTION&
A. Test: All sanitary and domestic water supply piping sl
be tested for leaks before piping is concealed or conned
to equipment and plumbing fixtures.
B. Disinfection: All domestic water piping shall be
disinfected by introducing a solution of calcium
hypochlorite of 50 parts per million of chloride and as
per AWWA Standards.
6. VALVES: Domestic water valves shall be of bronze body,
sweat ends.
7. CONTRACTOR SHALL COORDINATE exact location of all plumbin
system piping before starting any work. Notify
Architect /Engineer of any deviations from design drawings.
8. CONTRACTOR SHALL provide all necessary labor and materials
for a complete "turn -key" plumbing system.
9. CONTRACTOR SHALL keep accurate as -built dwgs on the field id provid(
them to owner once job is complete.
10. CONTRACTOR SHALL familiarize himself with job site and with I
construction documents including architectural, electrical. HVAC, d
structural dwgs, prior to bidding. Adjustments in the plumbing sy+m to
accommodate other disciplines should be expected, and shall not present
additional costs to owner. Notify Arch itect /Enigneer of any discrencies
prior to commencement of work.
11. Provide wall cleanouts at the base of every stack.
12. CONTRACTOR SHALL obtain insurance protect against public bility and
property damage for the duration of work.
16. CONTRACTOR SHALL use dimensions in architectural drawings )
rough -in plumbing work.
COVER SEURED
WITH SREWS
THREADED C, ❑,PLUG
r-FIN, GRDE
4 X 6' DIA, CONCRETE -
PAD FLUSH W /FIN, GRADE
eqPLUMBING FLOOR PLAN
,A'Nhp, SCALE: 1/4" = P-0"
TYPICAL CLEAN OU T DETAIL
EXTERIOR TYPE
ADJUSTABLE C ❑LL
THREADED C,O. P
FIN. FLOOR-7
SLIP JOINT
FLOOR
WALL
FACE OF WALL
STAINLESS STEEL COVER
SCREWED TO THREADED
C.O. PLUG.
PLUMBING SYMBOL LEGEND
SYMBOL
DESCRIPTION
FIXTURE
UNITS
SANITARY LINE
— — — — -
VENT LINE
SD
STORM DRAIN LINE
—� —�
SAFEWASTE LINE
CD
CONDENSATE LINE
P -2
GATE VALVE
-
COLD WATER LINE
--
HOT WATER LINE
P-
PLUMBING FIXTURE DESIGNATION
AAV
AIR ADMITANCE VALVE
FC❑
FLOOR CLEAN OUT
I
FLOOR PENETRATI ❑N
I
MECHANICAL SHOCK
1/2'
ARRESTOR
WC❑
WALL CLEAN ❑UT
VTR
VENT THRU ROOF
PLUMBING FIXTURE SCHEDULE
MARK
DESCRIPTI ❑N
FIXTURE
UNITS
HOT
WATER
WATER
WATER
REMARKS
P -1
WATER CLOSET
3
- --
1/2'
- - --
P -2
LAVATORY
1
1/2'
1/2'
P -3
SHOWER
2
1/2'
1/2'
W /ANTI -SCALD VALVE
P -4
KITCHEN SINK
2
1/2'
1/2'
U)
P -5
TDISHWASHER
- - --
1/2•
- - --
V SAFE WASTE
1) FIXTURES TO COMPLY W /FBC 2007 Plumbing Sections
709.1, 603,1, 604.3, & Sections 406 Through 421
2) ANTI -SCALD VALVE,
ALL SHOWERS & BATH /SHOWER COMBINATIONS SHALL
BE PROTECTED WITH A CONTROL VALVE OF THE
PRESSURE BALANCE, THERM❑STSTIC MIXING OR CDM-
BINATI ❑N TYPE SET. HANDLE POSITI ❑N STOPS PER
MANUFACTURERS INSTRUCTIONS AT TIME OF INSTALLATI ❑N
TO A MAXIMUM MIXED WATER OUTLET TEMPERATURE OF 110' F.
MAXIMUM FLOW RATES AND CONSUMPTION
TABLE 604.4
PLUMBING FIXTURE
OR FIXTURE FITTING
FLOW RATE
(gpm)
FLOW PRESSURE
(psi)
LAVATORY, PRIVATE
1.0
60
SHOWER HEAD
1.50
60
WATER CLOSET
1.28 gallons per
flushing cycle
- - --
LAND PLANNING
780 TAMIAMI CANAL RD.
CONSTRUCTION MANAGEMENT
CONSULTANTS
Miami, Florida 33144
n-= AND
CONTRACTOR
STING WATER
,�1
JUGS F. UII - IJu (�
•,
GLIERRERO /GONZA�V— I
ENGINEERS, INC. --/
,,.
Michael C. Guerrero, P.E.
MIAMI, FLORIDA 33186
MG echanical Eng. tic. $1525:
F. (305) 278 -7473
WWW.BELLONMILANES.COM
Rafael L Gonzalez, P.E ;
Electrical Eng. Lie. /11057"
ARCHITECTURE
LAND PLANNING
780 TAMIAMI CANAL RD.
CONSTRUCTION MANAGEMENT
CONSULTANTS
Miami, Florida 33144
Tel. (305) 262 -3944, Fax (305),
W
E —mail: PROJECTSOGUERREROGON ENO
CA# 0007612 ,. \.'
,r
'A
W
a rch itects
planners@
12485 S.W. 137 AVE. SUITE 103
MIAMI, FLORIDA 33186
T. (305) 278 -7776
F. (305) 278 -7473
WWW.BELLONMILANES.COM
AA- 0003505
ARCHITECTURE
LAND PLANNING
INTERIORS
CONSTRUCTION MANAGEMENT
CONSULTANTS
U -
NO
0L
W
F_
Z
W
Q
H 0
Z N � O
t.J.�
LL
Q
W
o W
5IQ
U)
_
W ct
N
n/ O 0
L.L N O
A�
W
Q
z
J
Q
01
1126/12
BDC
MARK
DATE
I DESCRIPTION
A.B. AS —BUILT
R.A.P. REVISION AFTER PERMIT
B D.C. BUILDING DEPT. COMMENTS
C.C. COORDINATION CHANGES
P.S. PERMIT SET
D.D. DESIGN DEVELOPMENT
P.H. PUBLIC HEARING
S.P.R. SITE PLAN REVIEW
PROJECT No. 1104
DRAWN BY: DNM
CHECKED BY: LB
LEOPOLDO BELLON, AIA
AR- 008737
ANGEL MILANES, AIA
AR- 0015845
SHEET TITLE
PLUMBING PLAN
P -1
SHEET 1 OF 1