GENERAL PLUMBING NOTES:
1. A. ALL WORK SHALL BE DONE in accordance with the Florida
Building Code (2007) and with all applicable regulations.
B. DRAWINGS: Refer to all drawings for coordination of the
plumbing work.
C. ARRANGE AND PAY for all permits, licenses, inspections
and tests. Obtain the required certificates and present
to owner.
D. GUARANTEE: The completed installation shall be fully
guaranteed against defective materials and /or improper
workmanship for a minimum of one year for material and
labor.
E. ALL HORIZONTAL SANITARY PIPING 2" or smaller shall slope at
1/4" per foot minimum, 3" or larger shall slope at a
1/8" per foot minimum.
2. SHOP DRAWINGS: Contractor shall submit for approval, within
30 days of signing contract, a minimum of five copies of fully
descriptive literature, including but not limited to: water
heaters, drains, piping and plumbing fixtures. No work shall proceed
without the approval of these submittals.
3. PLUMBING FIXTURES: Fixtures shall be as specified and shall be
fumished and installed by contractor. Fixtures shall be
complete with drains, traps, supplies and any other accessory
required.
4. MATERIALS:
A. PIPING:
a. Soil, waste and vent, and storm: Sanitary pipe, PVC
DWV, Sch 40.
b. Domestic water. Copper pipe, Type L with sweat wrought
copper fittings. Type "M" in concealed spaces is
acceptable. Isolate piping from concrete with insulating
material.
c. Condensate drain: DWC PVC, except use DWV Copper pipe and
fittings in a/c closets.
d. Domestic water supply assembly: Chrome finish tubing
with angle shut off valves.
B. INSULATION
a. Insulate oil handing hot water and hot water return
piping with 1/2 thick expanded closed cell polyethilene
compound similar to Armacell Tubolite
b. Insulate condensate drain pipes with 1/2 in. thick fire
rated foam plastic.
5. PIPING TEST AND DISINFECTION&
A. All sanitary and domestic water supply piping shall be
tested for leaks before piping is concealed or connected
to equipment and plumbing fixtures.
B. Gas system shall be tested as per FBC Fuel Gas 2007
Section 406 and NFPA -54 Chapter 8 requirements.
C. Disinfection: All domestic water piping shall be
disinfected by introducing a solution of calcium
hypochlorite of 50 parts per million of chloride and as
per AWWA Standards.
6. VALVES: Domestic water valves shall be of bronze body,
sweat ends.
7. HOSE BIBBS: Shall be 3/4 inch. rough brass construction with
shut off valve and vacuum breaker.
8. ALL OUTDOORS FLOOR dean outs shall be terminated up to grade
and sholl be marked.
9. CONTRACTOR SHALL COORDINATE exact location of sanitary,
and domestic water piping before starting any work. Notify
Architect /Engineer of any deviations from design drawings.
10. CONTRACTOR SHALL PAY for any engineering services related
to the revision of drawings as a result of any changes
originated by the contractor.
Z
w
a
n
a
7i
Ln
N
G7
N
O�
N
/1
V
1^�
Q
3
7
M
a
CL
W
N
+-1
r.8
co
J
0.
C7
Z
w
N
s
3
d
r
r■
lEgggib:
SYMBOL
DESCRIPTI ❑N
DESCRIPTION
SANITARY LINE
— — — --
VENT LINE
--- .-
SAFE & INDIRECT WASTE LINE
R
RELIEF LINES
CD
CONDENSATE LINE
DP
PAN DRAIN LINE
DRAINS, GUTTERS, ETC)
COLD WATER LINE
--
HOT WATER LINE
-HWR -- - - —
HOT WATER RETURN LINE
FC❑
FLUSH CLEAN OUT
CO
CLEAN OUT
VTR
VENT THRU ROOF
C❑ ❑G
CLEAN ❑UT ON GRADE
SAIPROCESSED. MOUNTED WITH WALL BRACKET
GATE VALVE
--�y—
CHECK VALVE
P_
PLUMBING FIXTURE
O
DESIGNATION
O
FLOOR PENETRATI ❑N
�i
WATER HAMMER ARRESTOR
HB —04-+
HOSE BIBB W/ SHUT-OFF VALVE
OVERFLOW
AND VACUUM BREAKER
WH
WALL HYDRANT
RECIRCULATING PUMP
Manufacturer, Mode �
DESCRIPTION
rurrcrUP-1 4EI7
r.
•r
, w Hz I!
PERFORATED
VENT CAP
SLOPE
12" MIN.
3/4"
3 i— "
CONDENSATE TRAP DETAIL
N.T.S.
SCHEDULE PLUMBING FIXTURE CONNECTION
DESCRIPTION
•
O
•r
1 1
Q
WATER CLOSET FLUSH TANK
FLOOR DISCHARGE
PREVENTION
DRAINS, GUTTERS, ETC)
fw�
OWNER SELECTION
LAVATORY (COUNTER
O
TBR
®
FLOAT
13
US
REGULATOR
SAIPROCESSED. MOUNTED WITH WALL BRACKET
OWNER SELECTION
viii
• +"
-®
O
REMAINNING WATER FROM VORTEX FILTER TO
O
# SELECTION/ SPECIFICATIONS
14
;SHOWER (NOTE 3)
GAUGE
OVERFLOW
KITCHEN SINK (ONE COMP.)
O
SMOOTHING INLET - STAINLESS STEEL
O
OWNER SELECT10N
15
LAUNDRY SINK (ONE COMP.)
FLOW CALMING" DEVICE TO ELIMINATE
OWNER SELECTION
•
®'
TURBULENCE THE INCOMING WATER
PURIFICATION KIT
OWNER
'
DISHWASHING M �
ENERGY STAR RATED
AS IT ENTERS THE TANK
r r
IIII 1,
REFRIGERAT OR
O
FLOATING STAINLESS STEEL SUCTION FILTER
11
DOMESTIC WATER
BY OWNER, R r CONTROL
RECESSED BOX (SIOUX CHIEF OX OR SIMILAR)
REQUIREMENTS
WASHER (ENERGY STAR RATED)
SUPPLY
FOR INSTALLATION
BY OWNER, PROVIDE CONTROL VALVES W/
RECESSED BOX r OR
SOLAR COLLECTORZWATER HEATER DETAIL
i
! ili 2—WAY SYSTEM
AC UNIT
IIm
EMA "i
TO
aNSU�M -ERs
WATER HEATER SCHEDULE
�I III
�� r i L�I � I�• _ � ' 4.5 II I�I II 2I I�Ir� V L r • �
11" CONCRETE ROUND
12" DIAMETER
PLASTIC PIPE
C14 CONDENSATE DRAIN
UNE FROM BUILDING
a ® SEE PLAN FOR SIZE.
Q
CONDENSATE DR. DRYWELL i
Li
F__1
( � I
L__J
PLAN VIEW
JRltlr��14-Alf
%$'Ts ,t
<C• :Z"
cL • "
••••.AF ELF� ••L . • s}
JOB NO. 11 -126
O
C 0 j POINT (ROOF
OO
Q
BACKF
PREVENTION
DRAINS, GUTTERS, ETC)
fw�
OPE ATING��T 45 PSIMP
DEVICELOW
O
TBR
7O
FLOAT
13
US
REGULATOR
SAIPROCESSED. MOUNTED WITH WALL BRACKET
FOR PUMPRPROTECTIONL(
VALVE T
AT 30
O
REMAINNING WATER FROM VORTEX FILTER TO
O
OVERFLOW
14
PRESSURE
GAUGE
OVERFLOW
O
SMOOTHING INLET - STAINLESS STEEL
O
CHECK VALVE
15
CHECK VALVE
FLOW CALMING" DEVICE TO ELIMINATE
TURBULENCE THE INCOMING WATER
PURIFICATION KIT
AS IT ENTERS THE TANK
O
FLOATING STAINLESS STEEL SUCTION FILTER
11
DOMESTIC WATER
REFER TO MANUFACTURER'S
REQUIREMENTS
SUPPLY
FOR INSTALLATION
AND FOR
EQUIPMENTS
SPECS. (RMS- RAINWATER
MANAGEMENT
RAINWATER HARVESTING SYSTEM DE7AIL
SOLUTIONS)
N.T.S.
WATER HEATER SCHEDULE
�I III
�� r i L�I � I�• _ � ' 4.5 II I�I II 2I I�Ir� V L r • �
11" CONCRETE ROUND
12" DIAMETER
PLASTIC PIPE
C14 CONDENSATE DRAIN
UNE FROM BUILDING
a ® SEE PLAN FOR SIZE.
Q
CONDENSATE DR. DRYWELL i
Li
F__1
( � I
L__J
PLAN VIEW
JRltlr��14-Alf
%$'Ts ,t
<C• :Z"
cL • "
••••.AF ELF� ••L . • s}
JOB NO. 11 -126
PROPOSM PROJECT FOR:
THE MOR141 ES RESIDENCE
6740 S.W. 64th COURT.. SOUTH
FORM GROUP,
US SWIRL" AM" COM CMA FL 3M
t. <<r
•1+• E
ARM= OF: M=M CMM hDRAW
WU
KTA
♦ .M
CLAIIIIIM NM
P-3.0 -
fw�
PROPOSM PROJECT FOR:
THE MOR141 ES RESIDENCE
6740 S.W. 64th COURT.. SOUTH
FORM GROUP,
US SWIRL" AM" COM CMA FL 3M
t. <<r
•1+• E
ARM= OF: M=M CMM hDRAW
WU
KTA
♦ .M
CLAIIIIIM NM
P-3.0 -