12-986R-001.3>C ELECTRICAL 1.- OVERALL INSTALLATION: THE INSTALLATION SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE (NEC), THE FLORIDA BUILDING CODE (FBC), AND ANY OTHER APPLICABLE FEDERAL, STATE AND LOCAL CODES. 2.- COMPLIANCE: WORKMANSHIP, MATERIALS AND INSTALLATION SHALL BE IN STRICT ACCORDANCE WITH THE APPLICABLE EDITION OF THE NEC, NFPA, NEMA, ASTM, OSHA, HRS HEALTH AGENCIES, AND OTHER APPLICABLE NATIONAL, STATE, AND LOCAL CODES AND PERTAINING REGULATIONS ESTABLISHED BY THE RULING AUTHORITY HAVING JURISDICTION. CONTRACTORS SHALL ALSO MEET THE REQUIREMENTS OF OTHER STANDARDS WHERE SUCH REQUIREMENTS ARE MORE STRICT THAN THOSE STANDARDS CITED ABOVE. 3.- MATERIALS: CONTRACTOR SHALL PROVIDE ALL NEW MATERIALS OF AMERICAN MANUFACTURE, BEARING THE UNDERWRITER'S LABORATORY (UL) LABEL AS APPLICABLE. 4.- PERMITS AND INSURANCE: CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, TAXES, INSPECTIONS, TESTS, FINES AND OTHER ITEMS AS REQUIRED FOR THE INSTALLATION OF THE COMPLETE ELECTRICAL SYSTEMS AS OUTLINED HEREIN AND SHOWN ON PLANS. CONTRACTOR SHALL PROVIDE ALL REQUIRED INSURANCE FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK. 5.- EXISTING CONDITIONS: BEFORE BIDDING, THE CONTRACTOR SHALL VISIT THE JOB SITE AND ASCERTAIN ALL EXISTING CONDITIONS WHICH WILL AFFECT HIS WORK. FAILURE TO DO SO WILL NOT BE ACCEPTED AS A REASON FOR REQUESTING EXTRA PAY WHERE THE EXISTING CONDITIONS RESULT IN EXTRA MATERIALS OR ANY EXISTING CONDITIONS FOUND BY THE CONTRACTOR WHICH WILL ADVERSELY AFFECT THE WORK SHALL BE IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE ARCHITECT /ENGINEER. CORRECTION OF ANY DEFECTS SHALL BE COMPLETELY WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENTS OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED THEREBY. 6.- CUTTING AND PATCHING: MAJOR CUTTING, PATCHING & PAINTING REQUIRED BY THIS CONTRACT WILL BE PERFORMED IN A NEAT AND WORKMANLIKE MANNER. ALL SURFACES SHALL BE RETURNED TO ORIGINAL CONDITIONS AFTER THE INSTALLATION OF THE EQUIPMENT. 7. -THE ELECTRICAL INSTALLATION SHALL MEET ALL STANDARD REQUIREMENTS OF THE LOCAL ELECTRIC UTILITY AND THE TELEPHONE COMPANY. 8. -LOAD DATA IS BASED ON INFORMATION PROVIDED TO THE ENGINEER AT THE TIME OF DESIGN. ALL EQUIPMENT AND PANEL SIZES SHALL BE VERIFIED BEFORE ORDERING. 9.- CIRCUITS SHOWN ON PLANS ARE USED TO DETERMINE LOAD DATA AND PANEL SIZES. THE CONTRACTOR SHALL PROVIDE CIRCUIT ROUTING TO SUIT THE JOB CONDITIONS. 10.- FURNISH AND INSTALL ALL FIXTURES AS CALLED FOR ON THE PLANS OR AS SELECTED BY OWNER /ARCHITECT. 11. -ALL CONDUCTORS SHALL BE RUN IN CONDUIT, U.O.N. 12.- INSTALL 1/2" EMPTY CONDUIT TO ALL TELEPHONE /DATA OUTLETS. PROVIDE PULL WIRE. 13.- INTERFERENCE: THE CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER TRADES SO THAT INTERFERENCE WITH EXISTING CONDITIONS, CONDUITS, PIPING, EQUIPMENT, ARCHITECTURAL AND STRUCTURAL MEMBERS BE AVOIDED. 14.- PLANS: DRAWINGS ARE BASICALLY DIAGRAMS INTENDED TO DEPICT APPROXIMATELY EQUIPMENT LOCATIONS AND ARRANGEMENTS, NOT TO SHOW EVERY MINOR DETAIL. PLANS SHALL NOT BE SCALED TO DETERMINE EXACT LOCATION AND DIMENSIONS. ELECTRICAL LEGEND 20 A., 120., V., DUPLEX RECEPTACLE,GROUNDING TYPE, U.O.N. MOUNTED 18" A.F.F. OR AS DIRECTED BY ARCHITECT. $ 20A, 120V GFI DUPLEX RECEPTACLE. ® 250V SPECIAL PURPOSE RECEPTACLE. *09- LIGHTING SWITCH ® 48" AFF. � 3 -WAY LIGHTING SWITCH ® 48" AFF. � SWITCH MOTOR RATE (60AMP). 0 PUSH BUTTON GARAGE OPENER. [:1 SAFETY DISCONNECT SWITCH. O ELECTRIC PANEL. M EXHAUST FAN. O SINGLE STATION SMOKE /CARBON MONOXIDE DETECTOR W /BATTE BACKUP AND INTERCONNECTED. TIE TO BATHROOM CIRCUIT. Tv TV OUTLET. = PHONE OUTLET. PROVIDE MUD RING AND 3/4 "C STUBBED ABOVE CEILING. - SURFACE OR PENDANT MOUNTED FIXTURE. WALL /PEDESTAL MOUNTED LIGHT. c = ABOVE THE COUNTER. WP = WEATHER PROOF. E = EXISTING TO REMAIN. TRory only to Cod GENERAL NO TES 15. -ALL ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN ACCESIBLE AREAS ONLY AND ABOVE BASE FLOOD ELEVATION. 16.- CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL WIRING, BREAKER AND FUSES SIZES IN ACCORDANCE WITH A/C EQUIPMENT NAMEPLATES, IF DIFFERENT FROM THOSE SPECIFIED ON DRAWINGS, AS WELL AS ANY FEEDER CHANGES BEING AFFECTED BY THIS CHANGE. CONTRACTOR SHALL MAKE ABOVE MENTIONED CHANGES AT NO EXTRA COST. 17.- ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL CONTRACTOR TO PROVIDE ALL REQUIRED J -BOXES AND CONDUITS FOR INSTALLATION OF CONTROL WIRING. LOW VOLTAGE CONTROL WIRING AND THEIR TERMINATION IS THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR. 18.- ELECTRICAL METER AND PANEL LOCATIONS SHOWN MAY VARY DEPENDING ON SERVICE ENTRANCE LOCATION. 19. -ALL LIGHTING FIXTURES TO BE SELECTED BY THE OWNER /ARCHITECT, U.O.N. AND SHALL BE INSTALLED BY THIS CONTRACTOR. 20.- BALANCE ALL PHASES AT EACH PANEL AND MDP /SERVICE MAINS. 21. -CHECK AVAILABLE ELECTRICAL SERVICE CHARACTERISTICS WITH THE LOCAL POWER COMPANY PRIOR TO ORDERING ANY EQUIPMENT. INFORM THE ARCH /ENGINEER IF IT IS DIFFERENT FROM WHAT IS SHOWN ON PLANS. 22.- ELECTRICAL CONTRACTOR SHALL ASSURE THAT ALL FEATURES OF SERVICE COMPLY WITH THE POWER COMPANY'S REQUIREMENTS AND SHALL MAKE ALL NECESSARY ARRANGEMENTS WITH POWER COMPANY FOR SERVICE. ALL EQUIPMENT NOT FURNISHED AND /OR INSTALLED BY THE POWER CO. IS TO BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. 23.- U.O.N., COORDINATE REQUIRED A.I.C. RATINGS WITH POWER COMPANY. 24. -WHERE MORE THAN ONE DEVICE IS INDICATED AT ANY LOCATION, THESE SHALL BE GANGED UNDER ONE COMMON COVER. 25.- QUANTITY AND LOCATION OF ELECTRICAL, TELEPHONE /DATA & TV OUTLETS, LIGHTS AND LIGHT CONTROLS, SHALL BE ADJUSTED TO SUIT THE OWNER'S REQUIREMENTS AS PER OWNER /ARCHITECT INSTRUCTIONS. SAID ARRANGEMENTS SHALL NOT BE IN CONFLICT WITH APPLICABLE CODES. 26.- ELECTRICAL CONTRACTOR SHALL VERIFY REQUIREMENTS, EXACT LOCATIONS, TYPE AND ARRANGEMENT OF OUTLETS FOR ALL ELECTRICAL FIXTURES, APPLIANCES AND EQUIPMENT, PRIOR TO INSTALLATION. 27.- PROVIDE A TYPEWRITTEN DIRECTORY FOR EACH ELECTRICAL PANEL. 28.- CONTRACTOR SHALL FURNISH AS -BUILT DRAWINGS TO THE OWNER UPON COMPLETION OF WORK AND PRIOR TO FINAL PAYMENT. 29.- OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY WITH THREADED HUBS IN WET /DAMP LOCATIONS AND SPECIAL ENCLOSURES AS REQUIRED FOR OTHER CLASSIFIED AREAS AND SHALL CONFORM TO NEMA STANDARDS. PLASTIC BOXES MAY BE USED WHERE PERMITTED UNDER APPLICABLE CODES AND ORDINANCES. 30. -ALL DISCONNECT SWITCHES SHALL BE SIZED BY NEC REQUIREMENTS TO ACCOMODATE THE EQUIPMENT SERVED, INCLUDING REJECTION CLIPS AND FUSES, WHEN APPLICABLE. SWITCHES SHALL BE HP RATED, QUICK -MAKE, QUICK - BREAK, IN NEMA 1 ENCLOSURES FOR INDOOR AND NEMA 3R FOR OUTDOOR. CIRCUIT SEE PLAN WIRE 12 BRKR 20 AMP SMOKE DETECTOR -� KITCHEN OR BATHROOM LIGHT SWITCH 120V PHASE CONDUCTOR SMOKE DETECTOR CONNECTION DETAIL PHASE: 10 BY - �1 2 -20 -13 OPL NEW SUBPANEL "Bn Many Lariga Scale MAKE: SIEMENS MAKE: SIEMENS VOLTAGE: 120/240 v VOLTAGE: 120/240 v Q J L'- Q Z Z Q TYPE: G203OLl150CU ° `0 00 TYPE: G203OLl150CU PANEL AMPS: 70 Amps (BRANCH BREAKERS TYPE QP, 10KAIC) (BRANCH BREAKERS TYPE QP, 10KAIC) MAIN BREAKER: 125 AMP Ckt No. MAIN BREAKER: 70 AMP SPEC Ckt USE SPEC VOLT BKR WIRE COND VA PH VA COND WIRE BKR VOLT SPEC USE Ckt q B No. 120 20 12 AMP AWG SIZE Q 1,500 SIZE AWG AMP 120 SMALL APPLIANCE No. 1 A.H.U. #1 ** 240 50 6 RM 8,184 4,186 3/4 10 25 240 NCL C.U. 1 ** 2 3 .l. 41 ry - 11, 1 •L 4 5 NEW BEDROOM LIGHTS & RECEPTACLES 120 15 14 RM s * RM 14 15 120 NEW BEDROOM LIGHTS & RECEPTACLES 6 7 INEW BEDROOM LIGHTS & RECEPTACLES 120 15 14 RM * 1,500 RM 12 20 120 SPACE 8 9 1 240 30 8 RM 5,000 1,500 RM 12 20 120 REFRIGERATOR 10 * SEE Load CALCULATION 41 .L * ** VERIFY NAME PLATE 14 15 120 GENERAL RECEPTACLES 14 15 GENERAL UGHTS & RECEPTACLES 120 GFI = GROUND FAULT INTERRUPTER. 14 RM * 1,500 RM 12 20 120 NCL = NON CONCURRENT LOAD. SMALL APPLIANCES 16 17 GENERAL UGHTS & RECEPTACLES 120 15 14 RM * RM = ROMEX. 5,000 RM 10 30 240 CLOTHES DRYER 18 19 NOTE -1: ALL 120 -VOLT, SINGLE - PHASE, 15- AND 20- AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS,PARLORS, LIBRARIES, DENS, BEDROOMS, SUN ROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC FAULT CIRCUITINTERRUPTER, COMBINATION -TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT. (2008 NEC. 210.12B NOTE -2: IN ALL AREAS SPECIFIED IN NOTE -1, ALL 125 -VOLT, 15 AND 20 AMPERE RECEPTACLES SHALL BE LISTED TAMPER RESISTANT RECEPTACLES. ELECTRICAL PLAN SC: 1/4 if PHASE: 10 BY - �1 2 -20 -13 OPL EXISTING PANEL ��A�� Many Lariga Scale MAKE: SIEMENS Job No VOLTAGE: 120/240 v Sheet E 1 ELECTRICAL PLAN Q J L'- Q Z Z Q TYPE: G203OLl150CU ° `0 00 PANEL AMPS: 125 Amps z (BRANCH BREAKERS TYPE QP, 10KAIC) MAIN BREAKER: 125 AMP Ckt No. USE SPEC VOLT BKR AMP WIRE AWG COND SIZE VA Mn N VA COND SIZE WIRE AWG BKR AMP VOLT SPEC USE Ckt No. A B 1 GENERAL UGHTS & RECEPTACLES L,J LD Q � Q 120 20 12 RM 1,200 Q 1,500 RM 12 20 120 SMALL APPLIANCE 2 3 RANGE ** 240 60 6 RM 9,600 s RM 4 70 240 `D SUBPANEL "8" ** 4 5 .f, N!, ry 11, 1 11, 6 7 1 DISHWASHER ** 120 20 12 RM 1,200 * RM 14 15 120 GENERAL RECEPTACLES 8 9 GENERAL UGHTS 120 15 14 RM * 1,500 RM 12 20 120 SMALL APPLIANCES 10 11 WATER HEATER 240 30 8 RM 5,000 1,500 RM 12 20 120 REFRIGERATOR 12 13 41 .L * RM 14 15 120 GENERAL RECEPTACLES 14 15 GENERAL UGHTS & RECEPTACLES 120 15 14 RM * 1,500 RM 12 20 120 SMALL APPLIANCES 16 17 GENERAL UGHTS & RECEPTACLES 120 15 14 RM * 5,000 RM 10 30 240 CLOTHES DRYER 18 19 CLOTH WASHER 120 20 12 RM 1,500 11, 14, 20 21 SPACE 1,000 * RM 12 20 120 NEW BATHROOM RECEPTACLE GFI 22 23 24 * SEE Load CALCULATION Load Calculation Calculation ** VERIFY NAME PLATE As per N.E.0 Art. 220.30 Section B. GFI = GROUND FAULT INTERRUPTER. 1,657 sqf x 3 va /sqf = 4,971 va Other Loads = 26,800 va NCL = NON CONCURRENT LOAD. Subtotal = 31,771 va RM = ROMEX. First 10,000 va ® 100% = 10,000 va Rest 21,771 va ® 40% = 8,708 va Subtotal = 18,708 va A/C Load = 8,184 va Total VA = 26,892 va Panel Load = 26,892/240 = 112 Amps A/C CALCULATIONS 240V -10 \ ►' COMPRESSOR: 16.7 AMP HEATER: 7,200 VA CONDENSER FAN: 0.74 AMP EVAP. BLOWER: 4.1 AMP EVAP. BLOWER: 4.1 A x 240 V = 980 VA 21.54 AMP TOTAL VA = 21.54 A x 240 V = 5,170 VA TOTAL HEATER = 8,184 VA SELECT LARGER NON CONCURRENT A/C LOAD: 8,184VA .r` OSCRRIPOSRDA ARCHITECT AR 0016550 9231 SW 12 ST. Miami Fl. 33174 305 -554 1094 786- 6835155 Fax: 305 - 5541134 ARENCO ®AOL.COM REVISION BY - �1 2 -20 -13 OPL File Many Lariga DESIGNS, ARRANGEMENTS, SPECIFICATIONS ARE OWNED ROPERTY OF THIS OFFICE 1TED, INVOLVED AND DEVEL- BE USE BY OR DISCLOSE FIRM OR CORPORATIO: WITHOUT THE wRriTEl OSCAR A. POSADA Drawn by O•P N 10- 10- 10 File Many Lariga Scale Li Job No 2010012 Sheet E 1 ELECTRICAL PLAN Q J L'- Q Z Z Q r1l L,_J = ° `0 00 z L U S W F- N L,J D L d I .y Z ED U O 0 - F-- r � Q n ° L,J LD Q � Q 00 In 3 o Z LLJ z � = L7 Q c-- H ° N `D ry DESIGNS, ARRANGEMENTS, SPECIFICATIONS ARE OWNED ROPERTY OF THIS OFFICE 1TED, INVOLVED AND DEVEL- BE USE BY OR DISCLOSE FIRM OR CORPORATIO: WITHOUT THE wRriTEl OSCAR A. POSADA Drawn by O•P Date 10- 10- 10 File Many Lariga Scale AS SHOWN Job No 2010012 Sheet E 1 ELECTRICAL PLAN ° °0000aooac0000 o �o �� o °000000O 0� °° o ° °�,� A' POS °° o ell 0 0. o� o V 9 0 o O GO o I o *0 A o 0 0 o ° a e vA 0 0 94 ° ° 0r 0 ° . 21850 ° AR 00 5 O rs °o o° ��V p o° °o�� Op °Op0000 °° � �O ° °ooC�REDu o 0 0�0 ° ° °00 t�