12-986-004IX6YT HVAC GENERAL NOTES 1. ALL WORK SHALL CONFORM WITH ALL LOCAL, STATE, FEDERAL ORDINANCES AND BUILDING 9. SHOP DRAWINGS: CONTRACTOR SHALL FURNISH THE ENGINEER WITH SHOP DRAWINGS OF CODES GOVERNING THE INSTALLATION OF THE MECHANICAL SYSTEM. IF WORK AS LAID OUT, EQUIPMENT PRIOR TO PURCHASE FOR APPROVAL. INDICATED OR SPECIFIED IS CONTRARY TO OR CONFLICTS WITH FIELD CONDITIONS, LOCAL SA, S.A., ORDINANCES, BUILDING CODES AND REGULATIONS, THE CONTRACTOR SHALL REPORT IN 10. AT COMPLETION OF JOB THE MECHANICAL CONTRACTOR SHALL GIVE THE OWNER AN WRITING TO THE ARCHITECT /ENGINEER BEFORE SUBMITTING A BID OR PROCEEDING WITH AS —BUILT SET OF REPRODUCIBLE DRAWINGS SHOWING THE EXACT LOCATION OF ALL WORK. THE ARCHITECT /ENGINEER WILL THEN ISSUE INSTRUCTIONS AS HOW TO PROCEED. INSTALLATIONS. 2. THE DRAWINGS ARE TO BE CONSIDERED DIAGRAMMATIC, NOT NECESSARILY SHOWING IN 11. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL AND EQUIPMENT DETAIL OR TO SCALE ALL OF THE MINOR ITEMS. UNLESS SPECIFIC DIMENSIONS ARE SHOWN, FOR A COMPLETE H.V.A.C. SYSTEM IN ACCORDANCE WITH THESE DRAWINGS. THE FLORIDA THE STRUCTURAL, ARCHITECTURAL AND SITE CONDITIONS SHALL GOVERN THE EXACT BUILDING CODE AND THE LATEST EDITION OF THE FOLLOWING LOCATIONS. CONTRACTOR SHALL FOLLOW DRAWINGS IN LAYING OUT WORK, CHECK DRAWINGS PUBLICATIONS: OF ALL TRADES TO VERIFY SPACES IN WHICH WORK WILL BE INSTALLED AND MAINTAIN a) ANS B91. MECHANICAL REFRIGERATION MAXIMUM HEAD ROOM, AND SPACE CONDITIONS AT ALL POINTS. COORDINATE LOCATION OF b) NFPA PAMPHLETS 90A & 91 DUCTWORK WITH OTHER TRADES, PARTICULARLY WHERE DUCTS RUN THROUGH STRUCTURAL c) SMACNA ELEMENTS. PROVIDE ALL NECESSARY SLEEVES BEFORE CONCRETE IS POURED. WHERE HEAD d) ASHRAE ROOM, OR SPACE CONDITIONS APPEAR INADEQUATE, ARCHITECT/ ENGINEER SHALL BE N NOTIFIED BEFORE PROCEEDING WITH INSTALLATION. THIS CONTRACTOR SHALL, WITHOUT EXTRA 12. ALL SUPPLY AIR CONDITIONING DUCTWORK SHALL BE 1%" STANDARD DUTY (R -6) FULL CHARGE, MAKE FIELD MODIFICATION IN LAYOUT AS NEEDED TO PREVENT CONFLICT WITH WORK REINFORCED FIBERGLASS WITH MANUFACTURE LOGO PRINTED ON THE VAPOR BARRIER WHEN OF VARIOUS TRADES OR FOR PROPER EXECUTION OF THE WORK. IN UNCONDITIONED SPACE, AND 3/4" STANDARD DUTY FOIL REINFORCED FIBERGLASS (R -4) NO WITH MANUFACTURE LOGO PRINTED ON THE VAPOR BARRIER IN CONDITIONED SPACE OR 3. EXAMINE ALL DRAWINGS CAREFULLY PRIOR TO SUBMITTING A BID. CONTRACTOR WILL BE RETURN PLENUM SPACE. R -6 FLEXIBLE DUCTS ARE ACCEPTABLE AS SHOWN ON DRAWINGS. REQUIRED TO FURNISH, INSTALL AND /OR CONNECT WITH APPROPRIATE SERVICES ALL � ED z PLUMBING ITEMS SHOWN ON ANY OF THE ARCHITECTURAL, AIR CONDITIONING, ELECTRICAL AND 13. ALL EXHAUST AIR DUCTWORK SHALL BE CODE GAGE GALVANIZED SHEET METAL. SPRINKLER DRAWINGS WITHOUT ADDITIONAL EXPENSE TO THE OWNER. IF DISCREPANCIES, Q CONFLICTS, INTERFERENCE OR OMISSIONS OCCUR BETWEEN DRAWINGS, NOTIFY IN WRITING THE 14. DUCT SIZES SHOWN ARE NET FREE AREA. ARCHITECT /ENGINEER IN AMPLE TIME TO PERMIT REVISIONS BEFORE THE BIDS ARE F-1 SUBMITTED. 15. ALL AIR DEVICES (DIFFUSERS, REGISTERS, AND GRILLES) SHALL BE ALL CD ALUMINUM CONSTRUCTION, WITH EXPOSED SURFACE CHEMICALLY TREATED TO 4. INSTALL MATERIALS AND EQUIPMENT IN A NEAT AND FIRST CLASS WORKMANLIKE MANNER. RECEIVE PAINT TO MATCH COLOR OF AIRGUIDE OR APPROVED EQUAL. THE OWNER RESERVES THE RIGHT TO DIRECT REMOVAL AND REPLACEMENT OF ITEMS WHICH, IN HIS OPINION, DO NOT PRESENT A NEAT AND WORKMANLIKE APPEARANCE. REMOVAL AND 16. PROVIDE TURNING VANES AT ALL ELBOWS. PROVIDE MULTIPLE VANE EXTRACTORS OR REPLACEMENT IS TO BE DONE IMMEDIATELY WHEN DIRECTED BY THE OWNER IN WRITING, SPLITTERS WITH CONTROL RODS AT ALL OUTLETS CONNECTED CLOSER THAN TWO DUCT AT THE SOLE EXPENSE OF CONTRACTOR. DIAMETERS TO MAIN SUPPLY DUCT AND WHERE SHOWN ON DRAWINGS. PROVIDE ALL `0 NECESSARY ACCESS PANELS TO CONTROL VALVES, DAMPERS, ETC. 5. START OF WORK BY CONTRACTOR SHALL BE CONSIDERED AS ACCEPTANCE BY HIM OF ALL CLAIMS OR QUESTIONS AS TO SUITABILITY OF THE WORK OF OTHER. TRADES OR OTHER 17. REFRIGERANT PIPING SHALL BE SEAMLESS COPPER TYPE "L" HARD OR SOFT DRAWN OR CONTRACTORS TO RECEIVE HIS WORK. THIS CONTRACTOR SHALL REMOVE AND REPLACE, AT ACR COPPER TUBING WITH WROUGHT COPPER SOLDER JOINT FITTINGS. SOLDER SHALL BE HIS EXPENSE, ALL MECHANICAL WORK WHICH MAY HAVE TO BE REMOVED BECAUSE OF 95/5, APPLIED WITH SUITABLE FLUX. INSULATE REFRIGERANT SUCTION PIPING WITH 3/4" INTERFERENCE WITH OTHER TRADES. FIRE RESISTANT FOAM PLASTIC OR CLOSED CELL POLYETHYLENE PRE — MOLDED PIPE 6. THIS CONTRACTOR SHALL OBTAIN AND PAY ALL INSURANCE, FEES, PERMITS, ASSOCIATION INSULATION. DUES, ROYALTIES AND TAXES OF WHATEVER NATURE SHALL APPLY TO THIS WORK. HE SHALL 18. ALL CONTROL WIRING SHALL BE THE RESPONSIBILITY OF THE MECHANICAL ALSO PAID ALL THE INSPECTION FEES AS MAY BE REQUIRED BY LAW OR ORDINANCE AND SUB — CONTRACTOR. MECHANICAL SUB CONTRACTOR TO FURNISH ALL MOTORS, STARTERS, SHALL KEEP THE OWNER HARMLESS FROM ANY DAMAGE AND EXPENSE ARISING FROM ANY AND RELAYS, ETC. VIOLATION OF LAWS, RULES OR ORDINANCES. 7. PROVIDE MEANS "FURNISH AND INSTALL ". 19. FOR INSTALLATION OF ANY ROOF OR WALL MOUNTED EQUIPMENT REFER TO ARCHITECTURAL STRUCTURAL ENGINEERING DRAWINGS. 8. DO A COMPLETE JOB, EVERYTHING CONNECTED, READY FOR USE. 1 IV 1 VI \L It 1 . VLI 1\11 11 IL L/\IJ IIIYV V/'ll \r\VL flll\ JVI 1 L-1 PICTURE # 2 : HOUSE RETURN AIR GRILL CClory on1V to Cued HVAC LEGEND ® F SUPPLY AIR DIFFUSERS (SEE SCHEDULE) DUCT TO MATCH NECK SIZE TYP. toxe NEW DUCT (WIDTH X DEPTH) pT PROGRAMMABLE THERMOSTAT AIR FLOW DIRECTION (ARROWS DENOTE 1 WAY, 2 WAY, ETC., SEE PLANS) RETURN OR EXHAUST, SEE PLANS. EXHAUST FAN E EXISTING TO REMAIN R EXISTING TO BE RELOCATED AHU AIR HANDLING UNIT CU SCHEDULE CONDENSING UNIT RA, R.A., R/A RETURN AIR SA, S.A., S/A SUPPLY AIR TA, T.A., T/A TRANSFER AIR UC BROAN DOOR UNDERCUT (1" TYP.) RAG S50U RETURN AIR GRILLE SAG 50 SUPPLY AIR GRILLE FAN SCHEDULE FAN DESIGNATION 10- 10- 10 EF -1 AREA SERVED W TOILET LOCATION Q J � CEILING MANUFACTURER BROAN MODEL NO. CD � CO S50U TOTAL AIR (CFM) 50 E.S.P. INCHES OF WATER 0.125 SONES I— 0.5 H.P. (A =AMP - W =WATTS `D 0.15 VOLT -PH -HZ N 120 -1 -60 DRIVE D DIRECT BACKDRAFT DAMPER a U NO INTERLOCK L0 ° LIGHT SWITCH REMARKS: 1. ALTERNATE MANUFACTURERS OF EQUAL OR BETTER QUALITY MAY BE SUBMITTED FOR APPROVAL. 2. UNLESS OTHERWISE NOTED ALL FANS SHALL BE EQUIPPED WITH SAFETY DISCONNECT SWITCH. NEW 3' THEMOFIN TO 1 SOFFIT VENT THR MECHANICAL PLAN SC: 1/4" OSCARIP08ADA ARCHITECT AR 0016550 9231 SW 12 ST. Miami Fl. 33174 305 -554 1094 786- 6835155 Fax: 305 - 5541134 ARENCO@AOL.COM REVISION BY ALL CONCEPTS, DESIGNS, ARRANGEMENTS, DRAWINGS AND SPECIFICATIONS ARE OWNED AND ARE THE PROPERTY OF THIS OFFICE AND WERE CREATED, INVOLVED AND DEVEL- OPED FOR USE ON AND IN CONJUCTION WITH THE SPECIFIC PROJECT. NO IDEA, DESIGN, ARRANGEMENT OR PLAN SHALL BE USE BY OR DISCLOSE TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WITHOUT THE WRITTEN PERMISSION OF: OSCAR A. POSADA ARCHITECT. Drawn by O.P N 10- 10- 10 File Many Lariga W AS SHOWN Job No Q J � Q Z Z � Q W = CD � CO F-i Q W I— _ `D Q� I— N LIJ D L�J I a U ED _ I- ly 2: : L0 ° Ld 0 Q Q 00 Lr) 3 � ED z L,J o L3 Q CL F-1 CD ci� (LI `0 ALL CONCEPTS, DESIGNS, ARRANGEMENTS, DRAWINGS AND SPECIFICATIONS ARE OWNED AND ARE THE PROPERTY OF THIS OFFICE AND WERE CREATED, INVOLVED AND DEVEL- OPED FOR USE ON AND IN CONJUCTION WITH THE SPECIFIC PROJECT. NO IDEA, DESIGN, ARRANGEMENT OR PLAN SHALL BE USE BY OR DISCLOSE TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WITHOUT THE WRITTEN PERMISSION OF: OSCAR A. POSADA ARCHITECT. Drawn by O.P Date 10- 10- 10 File Many Lariga Scale AS SHOWN Job No 2010012 Sheet M 1 MECHANICAL PLAN ° ° °�pQODODDD00p00 o° 0 F FL 0 A 0 °0000000 � ° �° v °° p ° 45v .0 06N 00 o �o 7-tA � 00 ca E * ° O /° a o . o ti °e o ° 2a o ° V o s° � o AR. 0018550 �o °° o 00 0 � O °00.00000 ° °°o��EDD D o g o ° °oo