12-986-001IX6YT I. (~lr)ry Only to (Tod EGRESS AND SECURITY NOTES - F.B.C. 2010 RESIDENTIAL 1. HEAD ROOM : MEANS OF EGRESS SHALL BE DESIGNED AND MAINTAINED TO PROVIDE A MINIMUM HEADROOM OF 7 FT WITH PROJECTION FROM THE CEILING AT LEAST 8' -0" ABOVE THE FINISH FLOOR. F.B.C.R305 2. LOCKS: A NIGHT LATCH, DEAD BOLT OR SECURITY DEVICE MAY BE USED ON EXIT DOOR FROM A DWELLING UNIT, PROVIDE SUCH DEVICES ARE OPEN ABLE FROM THE INSIDE WITH- OUT THE USE OF A KEY, TOOL, SPECIAL KNOWLEDGE OR EFFORT F.B.C. R311.4.4 3. WINDOWS : REQUIRED IN ALL HABITABLE ROOM FOR LIGHT AND VENTILATION AND SHALL BE SO CONSTRUCTED THAT WHEN FULLY OPENED THE TOTAL OPEN SPACE SHALL BE NO LESS THAN 4 PERCENT OF THE ROOM FLOOR AREA. F.B.C. R303.1 4. AREA OF THE WINDOWS FOR LIGHT AND VENTILATION MUST BE AT LEAST 8 % OF ROOM FLOOR AREA FBC- R303.1 5. TOILET ROOM WINDOWS MUST BE AT LEAST 3 SQ. FT. 1/2 OF WHICH MUST BE OPEN ABLE OR SHALL HAVE AN APPROVED EQUIVALENT MECHANICAL VENT. F.B.C. R303.3 6. MINIMUM EXIT DOOR SHALL BE 3 FEET IN WIDTH AND 6' -8" IN HEIGHT F.B.C. R311.4.2 7. AT LEAST ONE BATHROOM DOOR MUST PROVIDE A MIN. CLEAR OF 29" FOR HANDICAP ACCESS F.B.C. R322.1.1 8. GLASS DOORS AND GLASS PANEL ADJACENT TO DOORS MUST BE CATEGORY II SAFETY GLASS. F.B.C. R308 9. DIFFERENCE IN FLOOR LEVEL BETWEEN OPPOSITE SIDES OF EXTERIOR DOOR CAN BE MAXIMUM OF 7[ IN. F.B.C. R311.4.3 10. A LEVEL AREA AT LEAST AS DEEP AS THE DOOR WIDE MUST BE MAINTAINED ON BOTH SIDE OF THE DOOR. MIN. 36 IN. F.B.C. R311.4.3 11. THE MINIMUM WIDTH OF A HALLWAY SHALL BE NO LESS THAN 3 FEET F.B.C. R311.3 TERMITE PROTECTION AS PER FBC R320 ALL BUILDINGS SHALL HAVE PRE CONSTRUCTION TREATMENT PROTECTION AGAINST SUBTERRANEAN TERMITES AS PER F.B.C. R320. A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT :" THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT IS IN ACCOR- DANCE WITH THE RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRI- CULTURE AND CONSUMER SERVICES." EMERGENCY ESCAPE AND RESCUE OPENING F.B.C. R310 1. EVERY SLEEPING ROOM MUST HAVE AT LEAST ONE EMERGENCY ESCAPE AND RESCUE OPENING. F.B.C. R310.1 2. EMERGENCY ESCAPE AND RESCUE OPENING SHALL HAVE A SILL HEIGHT OF NO MORE THAN 44 IN. ABOVE THE FLOOR F.B.C. R310.1 3. EMERGENCY ESCAPE AND RESCUE OPENING SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET F.B.C. R310.1.1 4. EMERGENCY ESCAPE AND RESCUE OPENING SHALL HAVE A MINIMUM NET CLEAR OPENING HEIGHT OF 24 IN. F.B.C. R310.1.2 5. EMERGENCY ESCAPE AND RESCUE OPENING SHALL HAVE A MINIMUM NET CLEAR OPENING WIDTH OF 20 IN. F.B.C. R310.1.3 6. EMERGENCY ESCAPE AND RESCUE OPENING SHALL BE OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT THE USE OF TOOLS F.B.C. R310.1.4 INTERIOR ENVIRONMENTAL NOTES - F.B.C. 2010 RES. 1. AT LEAST ONE ROOM MUST BE A MINIMUM OF 120 SQ. FT. IN GROSS AREA. F.B.C. R304.14 2. NO HABITABLE ROOM OTHER THAN KITCHEN SHOULD BE LESS THAN 7 FT. IN ANY HORI- ZONTAL DIMENSION . F.B.C. R304.3 3. OTHER HABITABLE ROOMS SHALL HAVE A NET AREA OF NOT LESS THAN 70 SQ. FT. F.B.C. R304.2 GENERAL CONSTRUCTION NOTES - F.B.C. 2010 RES. 1. SHOWERS COMPARTMENTS SHALL HAVE FLOORS AND WALLS CONSTRUCTED OF SMOOTH, CORROSION RESISTANT AND NONABSORBENT WATER RESISTANT MATERIALS TO A HEIGHT OF NO LESS THAN 6 FT. ABOVE THE FLOOR. F.B.C. R307.2 2. ATTIC ACCESS REQUIRED IN WOOD ROOF TO BE AT LEAST 20 "X36" MINIMUM. FLAME SPREAD AND SMOKE DENSITY - FBC R315 R315.1 Wall and ceiling. Wall and ceiling finishes shall have a flame- spread classification of not greater than 200. R315.2 Smoke - developed index. Wall and ceiling finishes shall have a smoke - developed index of not greater than 450. C K C.L. SW. 58 STREET SITE PLAN SC: 1/16" LEGAL DESCRIPTION LOTS 9 AND 10 BLOCK 9 OF CAMBRIDGE LAWNS AS RECORDED IN PLAT BOOK 20 AT PAGE 48 OF THE PUBLIC RECORDS OF MIAMI DADE COUNTY FLORIDA FOLIO NUMBER: 09- 4025 - 018 -0220 LOT AREA = 13000 S.F. 0.29 ACRES MORE OR LEES ZONING : RS -3 SINGLE FAMILY LOW DENSITY SCOPE OF WORK: GARAGE CONVERTION INTO ONE BEDROOM, ONE BATHROOM, ONE CLOSET. REMOVE GARAGE DOOR BLOCK OPENING TO INSTALL NEW IMPACT RESISTANT WINDOW. RISE FLOOR TO MATCH EXISTING. AIR CONDITION AND ELECTRICAL SERVICE TO REMAIN UNCHANGED. LEVEL OF ALTERATION II AS PER FBC EXISTING BUILDINGS DEMOLITION PLAN DEMOLITION NOTES FBC -2010 SC: 1/4" 1302.1 Remodeling and additions. Required exits, existing structural elements, fire protection devices and sanitary safeguards shall be maintained at all times during remodeling, alterations, repairs or additions to any building or structure. 1302.2 Manner of removal. Waste materials shall be removed in a manner which prevents injury or damage to persons, adjoining properties and public rights -of -way. 1303.5 Water accumulation. Provision shall be made to prevent the accumulation of water or damage to any foundations on the premises 1303.6 Utility connections. Service utility connections shall be discontinued and capped in accordance with the approved rules and the requirements of the authority having jurisdiction. 1304.1.2 Surcharge. No fill or other surcharge loads shall be placed adjacent to any building or structure unless such building or structure is capable of withstanding the additional loads caused by the fill or surcharge. Existing footings or foundations which can be affected by any excavation shall be underpinned adequately or otherwise protected against settlement and shall be protected against later movement. 1305.1 Facilities required. Sanitary facilities shall be provided during construction, remodeling or demolition activities in accordance with the Florida Building Code, Plumbing . 1307.1 Protection required. Adjoining public and private property shall be protected from damage during construction, remodeling and demolition work. Protection must be provided for footings, foundations, party walls, chimneys, skylights and roofs. Provisions shall be made to control water runoff and erosion during construction or demolition activities. 1309.1 Where required. All structures under construction, alteration or demolition shall be provided with not less than one approved portable fire extinguisher 1310.2 Maintenance of exits. Required means of egress shall be maintained at all times during construction, demolition, remodeling or alterations and additions to any building. ' :IsYOF Sou 11.1M s,I_iILD{NG DEPT s i l; A SECTI 0SCARIP0 ADA ARCHITECT AR 0016550 9231 SW 12 ST. Miami F1. 33174 305 -554 1094 786 - 6835155 Fax: 305 - 5541134 ARENCO ®AOL.COM REVISION BY ARRANGEMENTS, TIONS ARE OWNED )F THIS OFFICE LVED AND DEVEL- BE Drawn by M -DaAe 10- 10- 10 File Many Lariga Scale AS SHOWN Job No M N L,J 1 PLAN Q � Q Z z CD CO Z Q LLJ = H W LLJ Q I- `0 = o� I- N Ld I L,J ° U o H Z LD Q ry Q LLJ z ° = CC) In 3 cl� ° z H 0 ClJ Q CLJ Z `0 Z ARRANGEMENTS, TIONS ARE OWNED )F THIS OFFICE LVED AND DEVEL- BE Drawn by o•P -DaAe 10- 10- 10 File Many Lariga Scale AS SHOWN Job No 2010012 Sheet A SITE 1 PLAN 0 F P-1 r� "moo j -7 e L n V ,Y J Co �� ., acs_ _7• j �� s� @.,! pp �� Y;: b is �•