14-384R-008FIRE RESISTANT JOINT
SYSTEM AT FIRE RATED
WALLS
UNDERSIDE OF STRUCTURE
CONT. COMPRESSIBLE
FILLER MATERIAL
WALL TOP ANCHORS
AT 4' —O" O.C.
FILL SOLID WITH GROUT
I
1
E
=tee
-t
k
'Wolin i 40111""
CEMENT PLASTER
�CLAC�MiPlItATION D-2
i6
G.W.B. TAPE i SPACKLE
CEMENTITIOUS ALL JOINTS USE 1/2"
BACKER BOARD
CERAMIC AT
(SEE NOTES , 15 AND 18)
1161min r• -
BASE
FIRE RATING REQUIREMENTS (AS INDICATED ON WALL TYPE TAG):
( —) NO FIRE RATING REQUIRED
(1) ONE —HOUR FIRE RATING REQUIRED AS PER UL DESIGN NO. U905
(2) TWO —HOUR FIRE RATING REQUIRED AS PER UL DESIGN NO. U905
NOTE: SIMILAR CONDITION APPLY TO CONCRETE WALL
I
0 .p
t[rl zr7 ■�I 6 IN 00
RATING FIRE (AS INDICATED ON WALL TYPE
NO i RATING REQUIRED
ri r
1 2 3
MARK
WIDTH
HEIGHT
THK
ELEV
TYPE
MAT'L
DESCRIPTION
ROOM NAME
NOTES
1
2' -0"
6' -8"
1 -3/4"
A
SWING
METAL
FLUSH
EXISTING TO REMAIN
2
5' -6"
8' -4"
1/2"
B
SLIDING
GLASS
FLUSH
MATERIAL
CLEAR
3
3' -0"
9' -0"
1 -3/8"
C
HIDDEN
WOOD
FLUSH
FRAMLESS
4
3' -0"
9' -0"
1 -3/8"
C
HIDDEN
WOOD
FLUSH
102
FRAMLESS
5
3' -0"
9' -0"
1 -3/8"
C
HIDDEN
WOOD
FLUSH
DRYWALL
FRAMLESS
6
3' -0"
9' -0"
1 -3/8"
C
HIDDEN
WOOD
FLUSH
FRAMLESS
7
3' -0"
9' -0"
1 -3/8"
C
HIDDEN
WOOD
FLUSH
104
FRAMLESS
8
3' -0"
9' -0"
1 -3/8"
C
HIDDEN
WOOD
FLUSH
DRYWALL
FRAMLESS
9
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
10
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
106
N.A.
11
3' -0"
8'-0"
1 -3/8"
D
PIVOT
WOOD
FLUSH
DRYWALL
12
3' -0"
8' -0"
1 -3/8"
D
PIVOT
WOOD
FLUSH
DRYWALL
13
3' -0"
8' -0"
1 -3/8"
D
PIVOT
WOOD
FLUSH
108
TRTMNT RM #4
14
2' -6"
8' -0"
1 -3/8"
E
POCKET
WOOD
LOUVER
DRYWALL
15
3' -0"
6' -8"
1 -3/4"
F
SWING
METAL
FLUSH
EXISTING TO REMAIN
16
2' -6"
8' -0"
1 -3/8"
G
PIVOT
WOOD
FLUSH
110
TRTMNT RM #6
17
=-6-8-4'
WOOD
1 -3/8"
H
POCKET
WOOD
FLUSH
DRYWALL
r••` •
WALLS & CEILINGS:
NOTE #1: ALL DOOR ASSEMBLIES SHALL BE PRE —HUNG.
NEW DOOR HARDWARE SHALL BE EQUAL TO SCHLAGE "E" SERIES LIGHT COMMERCIAL LEVERED HARDWARE.
NOTE #2: DOOR CLOSER SHALL BE EQUAL TO NUPRIN — LIGHT COMMERCIAL SERIES.
r r
A
.0
FINISH NOTES
WALLS & CEILINGS:
NOTE #1: GDW: 5/8" GYPSUM DRYWALL — LEVEL 4 FINISH
NOTE #2: MRGDW: 5/8" MOISTURE RESISTANT GYPSUM DRYWALL — LEVEL 4 FINISH
THESE DESIGNS AND DRAWINGS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF CANDELA + PARTNERS AND MAY NOT BE REPRODUCED EXCEPT WITH SPECIFIC WRITTEN CONSENT OF THE ARCHITECT. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL SITE CONDITIONS, VERIFY ALL DIMENSIONS OF THE JOB AND BE RESPONSIBLE FOR THE SAME, REPORTING ANY DISCREPANCIES TO THE ARCHITECT PRIOR TO PROCEEDING WITH WORK.
_ A
04.23.2014
Mu
ROOM FINISH SHEDULE
Checked By:
M.C.
Scale:
ROOM No.
ROOM NAME
C.14.1001
FLOOR FINISH
WALL
FINISH
CEILING FINISH
NOTES
FLOOR
BASE
MATERIAL
FINISH
MATERIAL
FINISH
101
RECEPTION
TILE
WOOD
DRYWALL & TILE
TILE & PAINT
DRYWALL
PAINT
SEE NOTE #1
102
WAITNG
TILE
WOOD
DRYWALL
PAINT
DRYWALL
PAINT
SEE NOTE #1
103
MANICURE
TILE
WOOD
DRYWALL
WOOD PANELING
DRYWALL
PAINT
SEE NOTE #1
104
GALLERY
TILE
WOOD
DRYWALL
TILE & PAINT
DRYWALL
PAINT
SEE NOTE #1
105
TRTMNT RM #1
TILE
WOOD
DRYWALL
PAINT
DRYWALL
PAINT
SEE NOTE #1
106
TRTMNT RM #2
TILE
WOOD
DRYWALL
PAINT
DRYWALL
PAINT
SEE NOTE #1
107
TRTMNT RM #3
TILE
WOOD
DRYWALL
PAINT
DRYWALL
PAINT
SEE NOTE #1
108
TRTMNT RM #4
TILE
WOOD
DRYWALL
PAINT
DRYWALL
PAINT
SEE NOTE #1
109
TRTMNT RM #5
TILE
WOOD
DRYWALL
PAINT
DRYWALL
PAINT
SEE NOTE #1
110
TRTMNT RM #6
TILE
WOOD
DRYWALL
PAINT
DRYWALL
PAINT
SEE NOTE #1
111
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
112
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
113
HALLWAY
TILE
WOOD
DRYWALL
PAINT
DRYWALL
PAINT
SEE NOTE #1
114
LOUNGE
TILE
WOOD
DRYWALL
PAINT
DRYWALL
PAINT
SEE NOTE #2
115
ALCOVE
TILE
WOOD
DRYWALL
PAINT
DRYWALL
PAINT
SEE NOTE #1
116
RESTROOM
TILE
WOOD
DRYWALL & TILE
TILE & PAINT
DRYWALL
PAINT
SEE NOTE #2
117
MECHANICAL
CONCRETE
N.A.
DRYWALL
PAINT
DRYWALL
PAINT
SEE NOTE #1
FINISH NOTES
WALLS & CEILINGS:
NOTE #1: GDW: 5/8" GYPSUM DRYWALL — LEVEL 4 FINISH
NOTE #2: MRGDW: 5/8" MOISTURE RESISTANT GYPSUM DRYWALL — LEVEL 4 FINISH
THESE DESIGNS AND DRAWINGS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF CANDELA + PARTNERS AND MAY NOT BE REPRODUCED EXCEPT WITH SPECIFIC WRITTEN CONSENT OF THE ARCHITECT. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL SITE CONDITIONS, VERIFY ALL DIMENSIONS OF THE JOB AND BE RESPONSIBLE FOR THE SAME, REPORTING ANY DISCREPANCIES TO THE ARCHITECT PRIOR TO PROCEEDING WITH WORK.
_ A
04.23.2014
Mu
;g
L1
a
X11
s r, ;
my
i
CANDELA + PARTNERS, LLC
ARCHITECTURE + PLANNING + INTERIORS
H I L A R I O F . C A N D E L A , F A I A
M URICE H. CANDELA . DESIGN
5940 SOUTHWEST 73RD STREET SUITE 200
SOUTH MIAMI, FLORIDA 33943 P,305.666J786
WWW.CANDELAANDPARTNERS.COM
H I L A R 1 0 F. C A N D E L A, F A I A
A R C H I T E C T,: -'A R 0 0 0 4 3 7 6
seal:
• 2 0 '
•
DIXIE SOUTH
A
consultant:
Date:
04.23.2014
Drawn by:
R.A.
Checked By:
M.C.
Scale:
AS SHOWN
Project No:
C.14.1001
Revisions
No. Date Description
1. 04.23.2014 Owner Rev.
2. 04.23.2014 Permit Comments
3. 08.26.2014 Owner Rev.
SCAED11LES ARr
PARTITION
Im � 1% T
I 1WEC-1�111L7_1