14-384-023GENERAL PLUMBING NOTES I: ALL WORK TO BE IN ACCORDANCE WITH THE 2010 FLORIDA BUILDING CODE. 2: BUILDING DRAINAGE SYSTEM DESIGN BASED ON 1 /8 "/FT. MIN .FAL ANY DEVIATIONS SHALL BE APPROVED ARCHITECT AND ENGINEER. 3: CONTRACTOR TO PROVIDE 3/4" (MIN) WATER PIPE CAPPED AT EVERY ELECTRICAL SWITCHGEAR ROOM DI METER ROOM TO BE USED AS GROUND. 4: ALL VALVES UNDERGROUND TO BE INSTALLED IN PRECAST CONCRETE BOXES "BROOKS" OR EQUAL 5. PLUMBING CONTRACTOR TO FURNISH ALL REQUIRED FLASHINGS FOR PIPES TO ROOFING CONTRACTOR. G.- MATERIALS SHALL BE ALL NEW AND AS FOLLOWS: A) SEWER AND STORM DRAINAGE PIPING: NO HUB CAST IRON, STO. 391 OR PVC -DWV. SCH.49 OR REFER TO F.B.C.2010, TABLE-702.1 (ABOVE-GROUND), TABLE -702.2 (UNDERGROUND) AND TABLE -702.3 (BUILDING SEWEE OTHERS ACCEPTABLES PIPING MATERIALS. B) WATER PIPING: TYPE K COPPER, PIPES COATED WITH ASPHALT. BELOW GROUND: TYPE L OR M COPPER (ABI GROUND) PROVIDE CPVC FOR 2" OF SMALLER CW /HW WITHIN UNITS. C) A/C CONDENSATE DRAIN: PVC SCH.49. EXCEPT IN A/C PLENUM D) PLUMBING FIXTURES: AMERICAN STANDARD, KOHLER, CRANE OR EQUAL E) FLOOR AND ROOF DRAINS, IF USED: JOSAM OR EGUAL F) ELECTRIC WATER HEATERS: GLASSLINED, 5 OR 10 YRS. GUARANTEE, AMERICAN, A.G. SMITH, PVI OR EGUAL G) VALVES: 125 PSI, NIBCO, SCOTT, OR EQUAL H) HOSE BIBBS: CHICAGO # 952 OR EGUAL 1) GAS PIPING: BLACK IRON, SCH. 40. 7.- HORIZONTAL BUILDING DRAINAGE PIPING OF 2" DIAMETER AND LESS SHALL BE INSTALLED WITH A FAIL OF LESS THAN 1 /4 7FT. 8: HORIZONTAL BUILDING DRAINS 3" OR DIAMETER OR LARGER SHALL BE INSTALLED WITH A FALL OF NOT LEI, THAN 1 /8 7FT. 9.- PIPES CONVEYING FIRE LINES AND DOMESTIC WATER LINES SHALL NUT BE INSTALLED UNDERNEATH A CON SLAB ON FILL IN ANY LOCATION INSIDE THE BLDG. WALLS OR BLOGS. ON FILLED GROUND WHERE THE PRESENCI HYDROGEN SULFIDE GAS OR OTHER INJURIOUS ELEMENTS ARE KNOWN TO EXIST, SUCH AS AREAS BEING OR Hi BEEN RECENTLY FILLED BELOW HIGH TIDE AREAS, 10: THE LOOPING OF COPPER ANNEALED -SOFT TUBING AND POLYBUTYLENE WATER PIPING BENEATH THE GROL FLOOR SLAB WILL BE PERMITTED IN SINGLE -STORY BUILDINGS OR MULTI -STORY SINGLE - FAMILY RESIDENCES THE PIPE SHALL BE ENCASED IN PLASTIC PIPE SLEEVES ITS TOTAL LENGTH TO INCLOSE TRHE TURN TO ABOVE TI. SLAB. FILLED BELOW HIGH TIDE AREAS. II: IN MULTI -STORY BUILDINGS, DOMESTIC WATER PIPES OF COPPER OR POLYBUTYLENE MAY BE INSTALLED BI THE GROUND FLOOR PROVIDING THE WATER PIPE DOES NOT EXCEEED 1 -1/2" IN DIAMETER AND IS ENCASED IN A PLASTIC SLEEVE OF PVC SIZED 2" LAARGER THAN THE WATER PIPE ENCASED, AND NOT EXCEEDING 49' -0" OF IT DEVELOPED LENGTH. WITH THE ENCASED WATER - DISTRIBUTION PIPE REMOVABLE FOR REPLACEMENT. 12: SHOULD THIS PROJECT HAVING PARKING FLOURS, THERE SHALL BE NO EXPOSED PVC PIPING WITHIN ANY PARKING LEVELS. PROVIDE COPPER OR CAST -IRON AS REGUIRED. 13: PROVIDE All EXCAVATION, BACKFILL AND COMPACTION REGUIRED BY ALL PLUMBING WORK. AND DEMOLITI EXISTING SLAB REG'D_ 14: PEFORM THE FOLLOWING TESTS: WATER PIPING SHALL BE SUBJECTED TO HYDROSTATIC PRESSURE A) TEST OR 100 PSIG. FOR A PERIOD OR TIME SUFFICIENT TO EXAMINE ENTIRE SYSTEM BUT NOT LESS THAN I B) DRAINAGE PIPING: BEFORE INSTALLATION OF ANY DRAIN, THE ENDS OF SYSTEM SHALL BE CAPPED AND ALL I FILLED W/ INSPECTION IS MADE AND WATER LEVEL REMAINS CONSTANT, C) CORRECT ALL DEFECTS DISCLOSED BY ABOVE TESTS. 15: STERILIZE All WATER LINES WITH A MIXTURE OF (2) POUNDS OF CHLORI -NATED LIME TO EACH 1000 GAL. G WATER (50PPH OF AVAILABLE CHLO- RINE). RETAIN MIXTURE IN PIPES 24 HRS. AND FLUSH THOROUGHLY W /PO WATER BEFORE PLACING IN SERVICE. IB: COMPLETE SERVICE. FIXTURES AND EGUIPMENT SHALL BE GIVEN AN IN -SER -VICE TEST AFTER COMPLETION THE INSTALLATION. 17.- PLUMBING CONTRACTOR SHALL FURNISH A WRITTEN GUARANTEE THAT ALL PLUMBING WORK SHALL BE FREI FROM DEFECTS OR MATERIALS AND WORKMAN SHIP FOR A PERIOD OF I YR. FROM DATE OF FINAL ACCEPTANCE, AND THAT HE WILL AT HIS EXPENSE REPAIR B REPLACE ALL WORK WHI BECOMES DEFECTIVE DURING THE GUARANTEE PERIOD. PLUMBING LEGEND ABBREVIATIONS B SYM PIPING 6 VALVES: 04.23.2014 Drawn by: R,A, �I co A/C CONDENSATE DRAIN AS SHOWN Project No: C.14.1001 Revisions SD STORM DRAINAGE No. Date — - - COLD WATER (CW) ® AD - - HOT WATER (HW) A/C S SANITARY (S) AP --- -V - - -- VENT (V) B/F W WASTE BFP GIN GREASE WASTE VTR I BAIL VALVE WH 1 RD D4 GATE VALVE AD M GLOBE VALVE FD 1-,4 STRAINER PLUMBING FIXTURES -i F- PIPE UNION W N CHECK VALVE D ASME P/T LAV I RELIEF VALVE SK I O— PIPE UP LAV I C PIPE DOWN WC CONNECT TO EXISTING (E) I Em NO PLUMBING WORK (N) I TO BE DONE I CASE I THICKENED I" CLEA /FLOOR SLAB GRADE BEAM OR THICKENED SLAB SLE PLUMBING PIPE ROUTED PERPENDICULAR TO BEAM OR THICKENED SLAB. I uu"i u ll- T u t I- I LU IY V I C0 PERPENDICULAR TO BEAM WHERE THE OUTLET FROM A FLOOR MOUNTED I. WATER CLOSET PASSES THROUGH. OR THICKENED SLAB. THE GRADE BEAM OR THICKENED SLAB THE SLEEVE PIPE SHALL TERMINATE BELOW THE WATER CLOSET FLOOR SEAL DETAIL- PLUMBING THROUGH FOUNDATION SCALE: N.T.S. THESE DESIGNS AND DRAWINGS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF CANDELA + PARTNERS AND MAY NOT BE REPRODUCED EXCEPT WITH SPECIFIC WRITTEN CONSENT OF THE ARCHITECT. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL SITE CONDITIONS, VERIFY ALL DIMENSIONS OF THE JOB AND BE RESPONSIBLE FOR THE SAME, REPORTING ANY DISCREPANCIES TO THE ARCHITECT PRIOR TO PROCEEDING WITH WORK, s MANUEL A. CID, P.E. LIC #45176 STATE OF FLORIDA PROFESSIONAL ENGINEER 14448 SW 173 STREET, MIAMI FL. 33177 PHONE NO. (305) 951 -2080 •..i accc CANDELA + PARTNERS, LLC ARCHITECTURE + PLANNING + INTERIORS H I L A R I O F . CANDELA, F A I A M URICE H. CANDELA . DESIGN 5940 SOUTHWEST 73RD STREET SUITE 200 SOUTH MIAMI, FLORIDA 33143 P.305.666.7788 WWW. CAN DELAANDPARTNERS.COM HILAR10 F. CANDELA, F A I A ARCHITEC.T;-,,AR0004376 ������1<<t1l�tlrrttlld�� ,. 01 sr seal: ° M I RA C L E S P A 6 2 0 8 SOUTH DIXIE HIGHWAY consultant: Date: 04.23.2014 Drawn by: R,A, Checked By: M.C. Scale: AS SHOWN Project No: C.14.1001 Revisions No. Date Description 1. 04.23.2014 Owner Rev. 2. 04.23.2014 Permit Comments P -1.0