Loading...
14-384-018TYP. SECURE W/ 1/8" STAINLESS STEEL CABLE OR STRAPS ANCHOR TO SLAB IN A CRISSCROSS PATTERN OVER UNIT. 3/8" BOLTS, NUTS 8 WASHERS SEE DETAIL "B" WEATHER HOOD PIPE INSULATION PITCH PAN BUILT-UP ROOF 20"x 31/2" REFRIG. PIPES ONDENSING UNITS ALUMA STAND, AL. PIPE FRAME 9 SUPPORT DADE CO. PROD. APP. 98-1206.01 FLASH AND SEAL TO ROOF (BY ROOF CONTRACTOR) WELD REF. LINES DOWN TO AIR HANDLER -BOLT THRU CONC, W/ 1/2" BOLTS, NUTS 8 IN CHASE WASHERS 8 STEEL PLATE 1/4" THICK TO STAND WINDS OVER 150 MPH CONDENSING UNIT INSTALLATION DETAIL SCHEME N.T.S. GALV. SHEET METAL HOOD W/ WEATHERTIGHT SEAMS AND WELDED SKIRT GALV. SHEET METAL OR FLEX-TUBE COLLAR SLOPE PIPES AWAY FROM HOOD GALV. FASTENERS APPROX. 6" D.C. NOTE: PIPING HOOD PROVIDED BY THIS CONTRACTOR FLASHING BY ROOFING CONTRACTOR. ROOF PENETRATION DETAIL FOR REFRIGERANT PIPES N.T.S. STRUCT JO SEE DETAIL HANGER STRAP 11/2". FOR DUCTS OVER 48" WIDE, FASTEN UNDER BOTTOM OF DUCT CONCRETE BEAM OR CONCRETE SLAB. LOW PRESSURE DUCT DUCT SIZE HANGER SIZE MAX. SPACING UP THRU 2 S.F. 11/2" x 1/16" 81-011 2 THRU 4 S.F. 11/2" x 1/8" 81-01, 4 THRU ID S.F. 111/2" x 1/8" 6,-D" OVER 10 S.F. 111/2" x 1/8" 4'-D" ti EZ-TRAP SERIES 200 FLOAT SWITCH TO SHUT-DOWN PVC OVERFLOW EQUIP. AS PER FMC. 301.13 DRAIN LINE REMOVABLE CAP 314" PERFORATED !! _F VENT CAP —IA SLOPE 1/8"/ SLOPE 12"MIN. UNION A/C UNIT DRAIN PAN 3/4" MIN. fiO3'MIN. CONDENSATE DRAIN TRAP DETAIL. N.T.S -11/2" MIN. STRAP, 26 G. offli 11117 mull" EXPANSION SHIELDS (2" EMBEDMENT) N.T.S. ,HANGER STRAPS GO" MAXIMUM UNLESS FOOT OF STRAP IS PLACED UNDER A BOTTOM REINFORCEMENT I SCREWS '—" SCREWS MAY BE OMITTED IF HANGER LOOPS P k 7' 7- T7 i (7 m P' 17 r',- T. L17- AF,(�""CT. T HE C­,JTRb S Rz�:"r-_ WCIO OR MODEL B-100 L OR 0-68 WALL CAP BACKDRAFT DAMPER 1/4" BIRD SCREEN RUST RESISTANT MIN. EL V. 10'-0" ABOVE GRADE PROPOSED B"ff EXHAUST G.M.D. (26 GAUGE) TO A NON CORROSIVE WALL CAP. (300 CFM) MIAMI TECH, INC. MN-ASWCB OR APPROVED EGUALPROVIDE INSECT SCREEN AND BACK DR- Ak F T DA MPER. ----------- - PROPOSED 4"H EXHAUST G.M.D. \ (Z,B GAUGE} - --T dMN 0 4 -E-- DR. Rb SI V E Wk CAP. (50 CFM) MI AM[ TECH, INC. MWASIVE Obi - --------- APPROVED EgUAL OV16E INSECT SCREEN AND BACK D A , AMPER. 4"OIA. S/M 26 GA. EXHAUST DUCT STRUCTURE CEILING FAN. CEILING WN / GRILLE\ � I 103 1, Fill 163 m 1111.1111 -2 5T 5T _\ REFRIGERANT LINES-- THRU ATTIC SPACE (SUCTION- .......... 40 91 B" O/A GMD UP TO ROOF -GAP. PROVIDE BIRD SCREEN ----- - ------ - ,AND BACKDRAFT DAMPER. OUTSIDE AIR INTAKE SHALL BE LOCATED A MINIMUM OF IDA" HORIZONTALLY FROM ANY HAZARDOUS OR NOXIOUS CONTAMINANT SOURCE. SUCH AS VENTS, STREETS, ALLEYS, PARKING LOTS AND LOADING DOCKS PROPOSED SITE/ROOF PLAN MANUEL A. CID, P.E. LIC. #45176 STATE OF FLORIDA PROFESSIONAL ENGINEER 14448 SW 173 STREET, MIAMI FL. 33177 PHONE NO. (305) 951-2080 0:10 CANDELA + PARTNERS, LLC ARCHITECTURE + PLANNING + INTERIORS H I L A R 1 0 F. C A N D E L A, F A I A MAURICE H. CANDELA . DESIGN 5940 SOUTHWEST 73RD STREET SUITE 200 SOUTH MIAMI, FLORIDA 33143 P.305.666,7788 WWW. CA N D E LAAN D PA R T N E R S , C 0 M H I L A R 1 0 F. CAN DELA, FAIA A R C H I T E C T: A R 0 0 0 4 3 7 6 seal: MIRACLE S P A 6 2 0 8 SOUTH DIXIE H I G H W A Y consultant: Date: 01.13.2014 Drawn by: R.A. Checked By: M.C. Scale: AS SHOWN Project No: C.14.1001 Revisions No. Date Description