14-384-002ALTERATION - LEVEL 2
SECTION 404
ALTERATION -LEVEL 2
404.1 Scope, Level 2 alterations include the reconfiguration of
space, the addition or elimination of any door or window, the
reconfiguration or extension of any system, or the installation of
any additional equipment.
404.2 Application. Level 2 alterations shall comply with the
provisions of Chapter 6 for Level 1 alterations as well as the
provisions of Chapter 7.
1A;:3'�I 01 K>G.+ Iii 1 � t�.b o►,.i � of i c tt txt
Utz. Gum � :. A y I Awllllo”
�? 6W S =vr- uot. vv_ awmw�Ac
6208 i t
SOUTH i•D
FOLIO No.: 09-4036-035-0011',
YEAR BUILT: 1952
LEGAL DESCRIPTION:
36 54 40 5.44 AC M/L PALM MIAMI HGTS AMD PB 38 -52 BEG AT A PT
136.53FTN OF SE COR TR 2 PB 38 -52 FOR POB TH RUN W305FT N151.07FT
W103.16FT NWLY195.86FT TO ELY R /W /L OF US
ZONING SUMMARY:
ZONING LAND USE: COMMERCIAL
ADJUSTABLE SQUARE FOOTAGE: 71,668 SF
LOT SIZE: 5.44 ACRES
SETBACKS:
SETBACKS
REQUIRED
AUTHORITY:
PROVIDED
FRONT
0' -0°
0'
-0" (EXISTING)
INTERIOR SIDE (WEST)
0' -0"
0'
-0" (EXISTING)
INTERIOR SIDE (EAST)
0' -0"
0'
-0" (EXISTING)
REAR
0' -0"
0'
-0" (EXISTING)
SITE PLAN LEGEND
I
t• t ii
CODE REVIEW
PROJECT DESCRIPTION:
EXISTING COMMERCIAL TENANT RENOVATION
AUTHORITY:
CITY OF SOUTH MIAMI PLANNING AND BUILDING DEPARTMENT
Checked By:
PH. 305 663 -6355
ZONING:
GR
FLOOD ZONE :
X
BUILDING CODE:
2010 FLORIDA BUILDING CODE
AMENDMENTS:
STATE AND LOCAL
PLUMBING CODE:
2010 FLORIDA PLUMBING CODE
MECHANICAL CODE:
2010 FLORIDA MECHANICAL CODE
GAS CODE:
2010 FLORIDA FUEL GAS CODE
ELECTRICAL CODE:
2008 NATIONAL ELECTRIC CODE
i. iy •. i ii � 1 i
BUILDING # •• • 1
NUMBER OF STORIES: ONE
NOTE:
6208 SOUTH DIXIE HIGHWAY IS SINGLE TENANT OCCUPANCY,
RATED EXISTING FIRE TENANT SEPARATION y BETWEEN ARE TO REMAIN.
y,
o�
I
n�• 4 a a. Y „�.`�. n. w
THESE DESIGNS AND DRAWINGS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF CANDELA + PARTNERS AND MAY NOT BE REPRODUCED EXCEPT WITH SPECIFIC WRITTEN CONSENT OF THE ARCHITECT. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL SITE CONDITIONS, VERIFY ALL DIMENSIONS OF THE JOB AND BE RESPONSIBLE FOR THE SAME, REPORTING ANY DISCREPANCIES TO THE ARCHITECT PRIOR TO PROCEEDING WITH WORK.
i
CANDELA + PARTNERS, LLC
ARCHITECTURE + PLANNING + INTERIORS
H I L A R I O F . C A N D E L A , F A I A
M URICE H. CANDELA . DESIGN
5940 SOUTHWEST73RD STREET SUITE 200
SOUTH MIAMI, FLORIDA 33143 P.305.666.7766
WWW. CAN DELAANDPARTNERS.00M
H I L A R 1 0 F. C A N D E L A, F A I A
ARCHITECT:..m AR'00`0,4376
c,
4r A
. x
seal:
i A
i
SOUTH
consultant:
Date:
04.23.2014
Drawn by:
R.A.
Checked By:
M.C.
Scale:
AS SHOWN
Project No:
C.14.1001
Revisions
No. Date Description
1. 04.23.2014 Owner Rev.
2. 04.23.2014 Permit Comments
BUILDING DATA +
LOCATION PLAN
7'0_lwc�