10-722-017C-5.8 C.U. #2 UPGRADED 250 AMP U.C. SERVICE BY FPL W/ 0) 250 MCM THWN IN 2 CONDUIT UNDERGROUND GROUND (2) #2\- THWN (CU) IN 1 1/4" CONDUIT (2)5/8x10' CU CwP DRIVEN RODS MIN. 6" APART RISER DIAGRAM Proposed Electrical Plan fI#RfZfZ1IH� ' 1250A MLO INTERIOR PNL'C (3) -250 MCM THWN CU IN 2" CONDUIT NOT TO SCALE SCALE: 1/4"=l'-Om ry 0 Z EQUIP. SCHED. PANEL 'A' 1. RANGE - 8.0 2. DISHWASHER = 1.5 3. DRYER - 5.0 4. CLG. FAN = 1.5 5. RECEPT APPL = 1.5 6. RECEPT APPL - 1.5 7. TANKLESS 1 = 11.8 8. TANKLESS 2 = 11.8 9. OVEN = 8.0 10. REFRIGERATOR = 1.5 11. WASHER - 1.5 TOTAL -56.3 DWELLING UNIT RECEPTACLE OUTLETS SHALL COMPLY WITH NEC 210.52 RESIDENCE LOAD CALCULATIONS PANEL 'C' RESIDENCE 1226 O 3 WATTS /SQ -FT ° 3678 EQUIPMENT 53,600 A/C (NON- COINCIDENTAL)(2 UNITS) (6.0) TOTAL LOAD 57,278 FIRST 10,000 WATTS ° 10,000 WATTS REMAINDER O 40% x 42,278 WATTS 18,911.2 HEAT O 100X 16,800 TOTAL 45,711.2 45.711.2/240- 190.46x1.25- 238.07 USE 250 AMP PANEL 'C' 120/23OV -1 PH- 3W -MLO 250A 42 CIRCUIT CKT DESCRIPTION C.B. POLE WIRE LOAD WIRE POLE C.B. DESCRIPTION CKT 1 Na 1 60 2 2 #6 TF(WN- 3/4 9.6 (3.5) 2#8 THWN-3/4-CU 2 40 C.U. No.1 2 3 4 N 2 30 2 2 #10THWN -3/4 "C 7.2 (2.5) 2 #12 THWN-3/4-CU 2 20 N 2 ELECTRICAL METER CAN 7 8 g RANGE 50 2 2 #6THWN -3/4 "C 8.0 8.0 2 #6 THWN- 3 /4 -CU 2 50 OVEN 10 11 12 13 DRYER 30 2 2#tOTHWN -3/4 "C 5.0 1.5 2 #12 THWN-1/2-CU 1 2D REFRIGERATOR 14 15 1.5 2 #12 THWN RMX. 1 20 WASHER 16 17 DISHWASHER 20 1 2 #12 THWN RMX. 1.5 - 2 #12 THWN RMX. 1 20 RECEPT. 18 19 RECEPTACLES 20 1 2 #12 THWN RMX. - - 2#12 THWN RMX. 1 20 LIGHTS 20 21 CLG. FAN 20 1 2 #12 THWN RMX. 1.5 - 2 #12 THWN RMX. 1 20 SMOKE DETECTOR 22 23 GFI RECEPTACLES 20 1 2 #12 THWN RMX. - 1.5 2}12 THWN RMX. 1 20 RECEPT APPLIANCE 24 25 RECEPT APPLIANCE 20 1 2 #12 THWN RMX. 1.5 - 2 #12 THWN RMX. 1 20 LIGHTS 25 27 RECEPTACLES 20 1 2 #12 THWN RMX. - - 2 #12 THWN RMX. 1 20 RECEPTACLES 28 29 SPARE 20 1 2 #12 THWN RMX. - - 2 #12 THWN RMX. 1 20 SPACE 30 31 TANKLESS WH #1 60 2 2 #12 THWN RMX. 11.8 11.8 3 #6 THWN- 3/4" CU 2 60 TANKLESS WH #2 32 -33.. 34 TOTAL I ELECTRICAL NOTES 1. GENERAL: ALL ELECTRICAL WORK SHALL CONFORM TO THE LATEST EDITION ,OF THE LOCAL BUILDING CODE HAVING,, JURISDICTION AND THE NATIONAL ELECTRICAL CODE. ALL MATERIALS SHALL BEAR UNDERWRITERS LABORATORIES -LABEL OR BE -U.L LISTED., WORKMANSHIP SHALL BE IN ACCORDANCE WITH GOOD, TRADE PRACTICES. ALL. EXCAVATING AND BACKFIWNG REQUIRED FOR , ELECTRICAL WORK SHALL' BE THE 'RESPONSIBILITY OF THE ELECTRICAL SUBCONTRACTOR. ` . 2: CONNEOTIONS TO'- EQUIPMENT: ELECThICAL SUBCONTRACTOR SHALL VERIFY NAMEPLATE DATA OF A/C EQUIPMENT, WATER HEATERS AND OTHER EQUIPMENT TO OBTAIN CORRECT WIRE SIZES AND OVER- CURRENT PROTECTION PRIOR TO INSTALLATION OF ROUGH ELECTRIC WIRING. THE ELECTRICAL SUBCONTRACTOR SHALL MAKE THE ELECTRICAL CONNECTION TO ALL EQUIPMENT REQUIRING CURRENT. ALL CONTROL WIRING SHALL BE CARRIED OUT BY THE ELECTRICAL SUBCONTRACTOR AS DIRECTED BY MECHANICAL CONTRACTORS. 3. OVERHEAD ELECTRIC CONDUCTOR CLEARANCES, HORIZONTAL AND VERTICAL SHALL BE MAINTAINED. 4. ALL LIGHTING SHALL BE ON DIMMERS. 5. BATHROOM, GARAGE AND EXTERIOR RECEPTACLES SHALL BE EQUIPPED WITH GROUND FAULT INTERRUPTERS. 6. ELECTRICAL INSTALLATION DESIGN IS IN COMPLIANCE AS SET FORTH BY THE STATE OF FLORIDA STATUTES MODEL ENERGY EFFICIENY CODES. 7. SMOKE DETECTORS SHALL BE HARD WIRED (110 VOLT) TO A NON - SWITCHABLE KITCHEN OR BATHROOM LIGHTING CIRCUIT AND SHALL NOT BE CONNECTED ONTO THE LOAD SIZE OF A GROUND FAULT INTERRUPTER. S/D SHALL BE INTERNCONNECTED & BATTERY BACK -UP. 8. ALL PANELS SHALL BE ITE OR EQUAL 9. FURNISH AND INSTALL UNDERGROUND RACEWAYS FOR POWER COMPANY SERVICE AND TELEPHONE COMPANY SERVICE AS PER UTILITY COMPANY SPECIFICATIONS AND COORDINATE THE EXACT ROUTING OF THESE RACEWAYS WITH THE UTILITY COMPANY. 10. VERIFY EXACT LOCATION OF ELECTRICAL OUTLETS AND LIGHTS PRIOR TO EXECUTION OF ROUGH IN WORK. 11. ALL RACEWAYS AND NON- CURRENT CARRY METAL ENCLOSURES SHALL BE MECHANICALLY AND ELECTRICALLY GROUNDED. 12. ALL RACEWAYS IN FINISHED AREAS SHALL BE CONCEALED AND ALL OUTLETS IN FINISHED AREAS SHALL BE CONCEALED AND ALL OUTLETS IN FINISHED AREAS SHALL BE MOUNTED FLUSH WITH FINISHED WALLS. 13. ALL WORK SHALL BE RIGIDLY MOUNTED AND SUPPORTED. 14. SWINNING POOL ELECTRICAL INSTALLATION SHALL BE IN STRICT ACCORDANCE WITH LATEST EDITION OF THE NATIONAL ELECTRICAL CODE. 15. ELECTRICAL OUTLETS "RECEPTACLES AND LIGHTING: BELOW BASE FLOOD ELEVATION SHALL BE INSTALLED AT HIGHEST PERMITTED ELEVATION AND SHALL BE INSTALLED ON A "SEPARATE" INDEPENDENT CIRCUIT FROM THOSE IN HABITABLE AREAS. 16. NO APPLIANCE OUTLETS SHALL BE INSTALLED BELOW THE BASE FLOOD ELEVATION. 17. A/C COMPRESSORS SHALL BE INSTALLED ABOVE THE BASE FLOOD ELEVATION. 18. MAIN CIRCUIT BREAKER PANEL SHALL BE INSTALLED ABOVE THE BASE FLOOD ELEVATION. 19. ALL WATER HEATERS SHALL BE MECHANICALLY GROUNDED. 20. NO RECEPTACLES SHALL BE PERMITTED WITHIN 15 FEET OF A SWIMMING POOL ELECTRICAL LEGEND FAN SCHEDULE WALL MOUNT LIGHT BRACKET MANUFACTURER AND MODEL NO. 120 V. DUPLEX OUTLET HP 120 V. G.F.I. DUPLEX OUTLET cF DIMENSIQN3 WxLxH IN. --b}- SWITCH � THREE WAY SWITCH 1500 1/20 E EXISTING R RELOCATED N NEW D DIMMER SWITCH W/P WATER PROOF V/P VAPOR PROOF 120 V. SPECIAL PURPOSE OUTLET ® 240 V. SPECIAL PURPOSE OUTLET 0 RECESSED DOWN LITE SURFACE MOUNTED FIXTURE Q PENDANT LIGHT FIXTURE g ELECTRICAL METER CAN ® MAIN CIRCUIT BREAKER PANEL EXTERIOR FLOOD LIGHTS Ip DISCONNECT SWITCH } EXHAUST FAN THERMOSTAT CABLE ® SMOKE DETECTOR HOMERUN TELEPHONE OUTLET 48 "0 CEILING FAN W /LIGHT FAN SCHEDULE FAN # MANUFACTURER AND MODEL NO. RPM HP CFM 8" S.P. ELECT.ECE VOLTS/PH/Hz DIMENSIQN3 WxLxH IN. WEIGHT LBS. REMARKS BATHROOMS GREENHECK SP -6 -QD 1500 1/20 60 O .125" 120/ 1/ /60 DIRECT 10 CAP S IRDC SCREEN ROOF BACK RAFT DAMPER. •a, GUILLERMO RAMON GO N ZALEZ 9000 S.W. 160TH AV M [AM 1. FL. 33 1 9 5 (305) 484 -8171 GUILLERMO R. GONZALEZ FL. REGIST. # AR139150 PROJECT NAME ZAS LO W REMODELING 6200 SW 78TH ST SOUTH MIAMI, FLA 33143 SHEET TITLE ELECTRICAL FLOOR PLAN DATE: 06/20/10 DRAWN BY: G.G. CHECKED BY: G.G. JOB NO. 03 -0010 SHEET NO. E -1 Y 0 y a , 'G y �s a 0