10-722-017C-5.8
C.U.
#2
UPGRADED 250 AMP
U.C. SERVICE BY FPL
W/ 0) 250 MCM THWN
IN 2 CONDUIT
UNDERGROUND
GROUND (2) #2\-
THWN (CU)
IN 1 1/4" CONDUIT
(2)5/8x10' CU CwP
DRIVEN RODS
MIN. 6" APART
RISER DIAGRAM
Proposed Electrical Plan
fI#RfZfZ1IH�
'
1250A
MLO
INTERIOR PNL'C
(3) -250 MCM THWN CU
IN 2" CONDUIT
NOT TO SCALE
SCALE: 1/4"=l'-Om ry
0
Z
EQUIP. SCHED.
PANEL 'A'
1. RANGE
- 8.0
2. DISHWASHER
= 1.5
3. DRYER
- 5.0
4. CLG. FAN
= 1.5
5. RECEPT APPL
= 1.5
6. RECEPT APPL
- 1.5
7. TANKLESS 1
= 11.8
8. TANKLESS 2
= 11.8
9. OVEN
= 8.0
10. REFRIGERATOR
= 1.5
11. WASHER
- 1.5
TOTAL -56.3
DWELLING UNIT
RECEPTACLE OUTLETS
SHALL COMPLY
WITH NEC 210.52
RESIDENCE LOAD CALCULATIONS
PANEL 'C'
RESIDENCE 1226 O 3 WATTS /SQ -FT ° 3678
EQUIPMENT 53,600
A/C (NON- COINCIDENTAL)(2 UNITS) (6.0)
TOTAL LOAD 57,278
FIRST 10,000 WATTS ° 10,000 WATTS
REMAINDER O 40% x 42,278 WATTS 18,911.2
HEAT O 100X 16,800
TOTAL 45,711.2
45.711.2/240- 190.46x1.25- 238.07
USE 250 AMP
PANEL 'C' 120/23OV -1 PH- 3W -MLO 250A
42 CIRCUIT
CKT
DESCRIPTION
C.B.
POLE
WIRE
LOAD
WIRE
POLE
C.B.
DESCRIPTION
CKT
1
Na 1
60
2
2 #6 TF(WN- 3/4
9.6
(3.5)
2#8 THWN-3/4-CU
2
40
C.U.
No.1
2
3
4
N 2
30
2
2 #10THWN -3/4 "C
7.2
(2.5)
2 #12 THWN-3/4-CU
2
20
N 2
ELECTRICAL METER CAN
7
8
g
RANGE
50
2
2 #6THWN -3/4 "C
8.0
8.0
2 #6 THWN- 3 /4 -CU
2
50
OVEN
10
11
12
13
DRYER
30
2
2#tOTHWN -3/4 "C
5.0
1.5
2 #12 THWN-1/2-CU
1
2D
REFRIGERATOR
14
15
1.5
2 #12 THWN RMX.
1
20
WASHER
16
17
DISHWASHER
20
1
2 #12 THWN RMX.
1.5
-
2 #12 THWN RMX.
1
20
RECEPT.
18
19
RECEPTACLES
20
1
2 #12 THWN RMX.
-
-
2#12 THWN RMX.
1
20
LIGHTS
20
21
CLG. FAN
20
1
2 #12 THWN RMX.
1.5
-
2 #12 THWN RMX.
1
20
SMOKE DETECTOR
22
23
GFI RECEPTACLES
20
1
2 #12 THWN RMX.
-
1.5
2}12 THWN RMX.
1
20
RECEPT APPLIANCE
24
25
RECEPT APPLIANCE
20
1
2 #12 THWN RMX.
1.5
-
2 #12 THWN RMX.
1
20
LIGHTS
25
27
RECEPTACLES
20
1
2 #12 THWN RMX.
-
-
2 #12 THWN RMX.
1
20
RECEPTACLES
28
29
SPARE
20
1
2 #12 THWN RMX.
-
-
2 #12 THWN RMX.
1
20
SPACE
30
31
TANKLESS WH #1
60
2
2 #12 THWN RMX.
11.8
11.8
3 #6 THWN- 3/4" CU
2
60
TANKLESS WH #2
32
-33..
34
TOTAL
I
ELECTRICAL NOTES
1. GENERAL: ALL ELECTRICAL WORK SHALL CONFORM TO THE LATEST EDITION
,OF THE LOCAL BUILDING CODE HAVING,, JURISDICTION AND THE NATIONAL
ELECTRICAL CODE. ALL MATERIALS SHALL BEAR UNDERWRITERS LABORATORIES
-LABEL OR BE -U.L LISTED., WORKMANSHIP SHALL BE IN ACCORDANCE WITH
GOOD, TRADE PRACTICES. ALL. EXCAVATING AND BACKFIWNG REQUIRED FOR
, ELECTRICAL WORK SHALL' BE THE 'RESPONSIBILITY OF THE ELECTRICAL
SUBCONTRACTOR. `
. 2: CONNEOTIONS TO'- EQUIPMENT: ELECThICAL SUBCONTRACTOR SHALL VERIFY
NAMEPLATE DATA OF A/C EQUIPMENT, WATER HEATERS AND OTHER EQUIPMENT
TO OBTAIN CORRECT WIRE SIZES AND OVER- CURRENT PROTECTION PRIOR TO
INSTALLATION OF ROUGH ELECTRIC WIRING. THE ELECTRICAL SUBCONTRACTOR
SHALL MAKE THE ELECTRICAL CONNECTION TO ALL EQUIPMENT REQUIRING
CURRENT. ALL CONTROL WIRING SHALL BE CARRIED OUT BY THE ELECTRICAL
SUBCONTRACTOR AS DIRECTED BY MECHANICAL CONTRACTORS.
3. OVERHEAD ELECTRIC CONDUCTOR CLEARANCES, HORIZONTAL AND VERTICAL
SHALL BE MAINTAINED.
4. ALL LIGHTING SHALL BE ON DIMMERS.
5. BATHROOM, GARAGE AND EXTERIOR RECEPTACLES SHALL BE EQUIPPED WITH
GROUND FAULT INTERRUPTERS.
6. ELECTRICAL INSTALLATION DESIGN IS IN COMPLIANCE AS SET FORTH BY THE
STATE OF FLORIDA STATUTES MODEL ENERGY EFFICIENY CODES.
7. SMOKE DETECTORS SHALL BE HARD WIRED (110 VOLT) TO A NON - SWITCHABLE
KITCHEN OR BATHROOM LIGHTING CIRCUIT AND SHALL NOT BE CONNECTED ONTO
THE LOAD SIZE OF A GROUND FAULT INTERRUPTER. S/D SHALL BE
INTERNCONNECTED & BATTERY BACK -UP.
8. ALL PANELS SHALL BE ITE OR EQUAL
9. FURNISH AND INSTALL UNDERGROUND RACEWAYS FOR POWER COMPANY SERVICE
AND TELEPHONE COMPANY SERVICE AS PER UTILITY COMPANY SPECIFICATIONS
AND COORDINATE THE EXACT ROUTING OF THESE RACEWAYS WITH THE UTILITY
COMPANY.
10. VERIFY EXACT LOCATION OF ELECTRICAL OUTLETS AND LIGHTS PRIOR TO
EXECUTION OF ROUGH IN WORK.
11. ALL RACEWAYS AND NON- CURRENT CARRY METAL ENCLOSURES SHALL BE
MECHANICALLY AND ELECTRICALLY GROUNDED.
12. ALL RACEWAYS IN FINISHED AREAS SHALL BE CONCEALED AND ALL OUTLETS
IN FINISHED AREAS SHALL BE CONCEALED AND ALL OUTLETS IN FINISHED
AREAS SHALL BE MOUNTED FLUSH WITH FINISHED WALLS.
13. ALL WORK SHALL BE RIGIDLY MOUNTED AND SUPPORTED.
14. SWINNING POOL ELECTRICAL INSTALLATION SHALL BE IN STRICT ACCORDANCE
WITH LATEST EDITION OF THE NATIONAL ELECTRICAL CODE.
15. ELECTRICAL OUTLETS "RECEPTACLES AND LIGHTING: BELOW BASE FLOOD
ELEVATION SHALL BE INSTALLED AT HIGHEST PERMITTED ELEVATION AND
SHALL BE INSTALLED ON A "SEPARATE" INDEPENDENT CIRCUIT FROM THOSE
IN HABITABLE AREAS.
16. NO APPLIANCE OUTLETS SHALL BE INSTALLED BELOW THE BASE FLOOD
ELEVATION.
17. A/C COMPRESSORS SHALL BE INSTALLED ABOVE THE BASE FLOOD ELEVATION.
18. MAIN CIRCUIT BREAKER PANEL SHALL BE INSTALLED ABOVE THE BASE FLOOD
ELEVATION.
19. ALL WATER HEATERS SHALL BE MECHANICALLY GROUNDED.
20. NO RECEPTACLES SHALL BE PERMITTED WITHIN 15 FEET OF A SWIMMING POOL
ELECTRICAL LEGEND
FAN SCHEDULE
WALL MOUNT LIGHT BRACKET
MANUFACTURER
AND MODEL NO.
120 V. DUPLEX OUTLET
HP
120 V. G.F.I. DUPLEX OUTLET
cF
DIMENSIQN3
WxLxH IN.
--b}-
SWITCH
�
THREE WAY SWITCH
1500
1/20
E
EXISTING
R
RELOCATED
N
NEW
D
DIMMER SWITCH
W/P
WATER PROOF
V/P
VAPOR PROOF
120 V. SPECIAL PURPOSE OUTLET
®
240 V. SPECIAL PURPOSE OUTLET
0
RECESSED DOWN LITE
SURFACE MOUNTED FIXTURE
Q
PENDANT LIGHT FIXTURE
g
ELECTRICAL METER CAN
®
MAIN CIRCUIT BREAKER PANEL
EXTERIOR FLOOD LIGHTS
Ip
DISCONNECT SWITCH
}
EXHAUST FAN
THERMOSTAT
CABLE
®
SMOKE DETECTOR
HOMERUN
TELEPHONE OUTLET
48 "0 CEILING FAN W /LIGHT
FAN SCHEDULE
FAN #
MANUFACTURER
AND MODEL NO.
RPM
HP
CFM 8" S.P.
ELECT.ECE
VOLTS/PH/Hz
DIMENSIQN3
WxLxH IN.
WEIGHT
LBS.
REMARKS
BATHROOMS
GREENHECK SP -6 -QD
1500
1/20
60 O .125"
120/ 1/ /60
DIRECT
10
CAP S IRDC SCREEN ROOF
BACK RAFT DAMPER.
•a,
GUILLERMO
RAMON
GO N ZALEZ
9000 S.W. 160TH AV
M [AM 1. FL. 33 1 9 5
(305) 484 -8171
GUILLERMO R. GONZALEZ
FL. REGIST. # AR139150
PROJECT NAME
ZAS LO W
REMODELING
6200 SW 78TH ST
SOUTH MIAMI, FLA 33143
SHEET TITLE
ELECTRICAL
FLOOR PLAN
DATE:
06/20/10
DRAWN BY:
G.G.
CHECKED BY:
G.G.
JOB NO.
03 -0010
SHEET NO.
E -1
Y
0
y
a
,
'G
y
�s
a
0