Loading...
10-722-016SUPPLY AIR DUCT TURNING VANED NEOPRENE PAD VIBRATION ISOLATER PROVIDE 3 "x3" GALVANIZED ANGG ANGLE W / #8 SCREWS ® 6" O.C. TO DUCT MECHANICAL ATTACHED A.H.U. AS PER FBCR- M 1601.6.2.2 AIR HANDLER UNIT- FLOAT SWIM DRAIN PAN RETURN AIR FL00 R--i SUPPLY AIR GAS LINE AND LIQUID LINE TO CONDENSING UNIT ,TI►G7�1:7:�G FILTER METAL STAND CONDENSATE DRAIN TO TERMINATE 6" ABOVE GRADE, OR TO DRAIN AHU MOUNTING DETAIL AIR CONDITIONING SYSTEM GENERAL NOTES (IF APPLICABLE) 1. WORK INCLUDED: PROVIDING HEAT. VENTILATION, AND AIR CONDITIONING SYSTEMS WHERE SHOWN ON THE DRAWING, AS SPECIFIED HEREIN, AND AS NEEDED FOR A COMPLETE AND PROPER INSTALLATION INCLUDING, BUT NOT NECESSARILY LIMITED TO • AIR CONDITIONING SUPPLY AND RETURN DUCTWORK SYSTEM WITH GRILLES. DIFFUSERS. AND REGISTERS. • AIR CONDITIONING UNITS, PIPING AND COMPONENTS, OPERATING AND SAFETY CONTROLS, BLOWERS, MOTORS, FILTERS. AND RELATED ITEM. * EXHAUST SYSTEMS INCLUDING TOILET FANS. MOTORS. DUCTWORK. FRILLES. REGISTERS. CONTROLS. AND REGISTERS. • TEMPERATURE CONTROL SYSTEM INCLUDING LOW VOLTAGE WIRING. • THERMAL INSULATION OF DUCTS AND PIPING. 2. KNAUF AIR DUCT TYPE EI -475 FIBERGLASS WITH VAPOR BARRIER. DUCT WORK BETWEEN FLOORS, ENCLOSED ATTACHED GARAGES, UNCONDITIONED BASEMENT, UNCONDIRIONED INTERIOR SPACES, AND ROOF WITH MIN R -12 INSULATION SHALL BE R -4.3 KNAUF AIR DUCT FIBERGLASS TYPE E1800 WITH VAPOR BARRIER. UNLESS OTHERWISE SPECIFIED DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS AND ACCORDING TO " ASHRAE" AND "NAIMA" STANDARDS, AND 2004 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION. ALL OUTSIDE DUCTWORK SHALL BE GALVANIZED STEEL, DESIGND, CONSTRUCTED, INSTALLED AND TESTED IN ACCORDANCE WITH LATEST EDITION OF "SMACNA ". DUCTWORK TO HAVE MANUFACTURE'S GUAGE STAMP. PROVIDE CROSS BREAKING OR BEADING TO PREVENT FLEXING. BUT DO NOT REDUCE GUAGE OF METAL BELOW THAT REQUIRE FOR FLAT DUCTWORKI. ALL EXTERIOR DUCTWORK SHALL BE SEALED TO 100% CLOSURE WITH APPROVE CLOSURE SYSTEMS. DUCTWORK ON ATTICS SPACE AND ROOF WITH LESS THAN R -12 INSULATION SHALL BE 1 -1/2" THICK R -6.5, ALL DUCTWORK SHALL BE METAL FABRICATED AND INSTALLED IN ACCORDANCE WITH MANUFACTURE'S SPECIFICATIONS AND ACCORDING TO ASHRAE AND SMACNA STANDARDS, AND 1993 SOUTH FLORIDA ENERGY CODE FOR BUILDING CONSTRUCTION. SHALL COMPLY WITH "NFPA" STANDARD No. 90A AND /PR 90B DUCTWORK AND COMPONENTS S SHALL BE CLASS 1 MATERIALS IN ACCORDANCE WITH U.L. 181 TESTS. FIBERGLASS DUCT SYSTEM STRAIGHT SECTIONS AND FITTINGS SHALL BE REINFORCED BY EITHER OR BOTH OF THE FOLLOWING METHODS: A) TIE ROD REINFORCEMENT AND OR B) CHANNEL REINFORCEMENT. REFER TO THE FIBROUS GLASS DUCT CONSTRUCTION STANDARDS AND MANUFACTURER RECOMMENDATION. LOGITUDINAL SEAMS AND TRANSVERSE JOINTS CLOSURES SHALL COMPLY WITH UL 181 A/P )PRESSURE SENSITIVE ALUMINUM FOIL TAPE) OR 181 A/H (HEAT SELLABLE ALUMINUM FOIL TAPE OR MANUFACTURER'S RECOMMENDATIONS FOR THE USE OF GLASS FABRIC AND MASTIC. DUCT SUPPORT SHALL BE PLACED SO AS TO PROPERLY SUPPORT ALL FITTINGS AND ACCESSORIES WITHOUT PLACING THE TAPED JOINTS UNDER STRESS. 3. COORDINATE LOCATIONS, SIZES AND OPENINGS WITH OTHER TRADES ON THE JOB. A/C CONTRACTOR SHALL DAMPERS AS REQUIRED OR SHOWN ON THE DRAWING. DUCT DIMENSIONS ARE IN INCHES AND CORRESPOND TO INSIDE DIMENSIONS. WITH x HEIGHT. DUCT SYSTEM 4. DIFFUSERS SHALL BE SELECTED. LOCATED AND BALANCED IN ORDER THAT THEY DELIVER THE REQUIRED CFM TO THE ENTIRE ROOM EVENLY AND DRAFT FREE TO THE FOLLOWING DESIGN CONDITIONS. INSIDE OUTSIDE RELATIVE HUMIDITY COOLING - 78 dB 91 dB -79 wB 50% TO 60% HEATING - 72 dB 5. OBJECTIONABLE SOUND WILL BE HEARD IN THE HABITABLE SPACES DUE TO AIR VELOCITY, MOTOR HUM, VIBRATION OR MECHANICAL MOVEMENT. PROVIDE THE COMPLETE DUCT SYSTEM WITH TURNING VANES AT ALL ELBOWS, AND INSTALLED SPLINTERS AND 6. A/C SYSTEM SHALL HAVE 1- AIR FILTERS AS SPECIFIED LOCATION AND AS REQUIRED FOR EASY ACCESSIBILITY. 7. A/C SYSTEM SHALL BE CONTROLED BY A THERMOSTAT MOUNTED 5' ABOVE FINISH FLOOR. 8. ALL GRILLES AND DIFFUSERS TO BE ALUMINUM CONSTRUCTION. ALL DIFUSERS SHALL HAVE HIDEN OPPOSED BLADE DAMPERS. PROVIDE GASKETS ON ALL GRILLES AND DIFFUSERS. 9. UNDERCUT DOORS A.F.F. AS INDICATED 10. ALL REFRIGERANT PIPING SHALL BE COPPER HARD DRAWN TYPE - L -ACR, DEHYDRARED AND SEALED. ALL FAN. MOTORS, COMPRESSORS, ETC. SHALL BE ISOLATED, AS REQUIRED TO OPERATE QUIETLY SO THAT NO OF NOT LESS THAN 5% SILVER. PIPING INSULATION NOT LESS THAN 3/4" THICK "ARMAFLEX ". LIQUID AND SUCTION LINES SHALL BE SIZED ACCORDING TO EQUIPMENT MANUFACTURER'S RECOMMENDATION FOR EQUIVALENT LENGTH OF PIPING RUN FOR CONNECTED TONNAGE. ALL PIPING ACCESSORIES SHALL BE CONSTRUCTED AS SUGGESTEDD BY EQUIPMENT MANUFACTURER. PROVIDE FILTER /DRYER AND SIGHT GLASS ON LIQUID LINE. REFRIGERANT PIPING SYSTEM SHALL BE COMPLETED EVACUATED TO 26" VACUUM OF MERCURARY GUAGE PRESSURE USING A VACUUM PUMP AND HOLD FOR A MINIMUM OF 24 HOURS. COMPRESSORS SHALL NOT BE USED TO EVACUATED SYSTEMS. CHANGE THE OIL IN THE VACUUM PUMP BEFORE VACUUM IS PULL. VACUUM SHALL BE BROKEN WITH THE OPENING REFRIGERANT. 11. ALL VENTILATION DUCTWORK SHALL BE SHEETMETAL INSTALLED ACCORDING TO LAST EDITION OF "SMACNA" AND " ASHRAE" FOR LOW PRESSURE DUCT SYSTEM. FLEXIBLE DUCT SHALL BE CLASS 1 U.L. LISTED, PROVIDE FOSTER 32 -50 AT ALL SHEETMTAL DUCT CONNECTIONS. THE CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER TRADES. 12. FITTINGS SHALL BE WROUGHT COPPER. ALL JOINTS SHALL BE MADE WITH HIGH TEMPERATURE BRAZING ALLOY 13. THE CONTRACTOR SHALL THOROUGHLY EXAMINE THE SITE, SATISFY HIMSELF TO EXISTING CONDITIONS UNDER WHICH THE WORK IS TO BE PREFORMED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY FIELD CONDITION AFFECTING HIS WORK. 14. ELECTRIC HEATERS: SHALL BE MOUNTED IN BOX CASING WITH CAPACITIES AS SHOWN IN THE SCHEDULE. HEATERS TO BE U.L. LABELED AND LISTED FOR ZERO CLEARANCE AS A DUCT HEATER. ELEMENTS TO BE OPEN TYPE GRADE A NICHROME WIRE. EACH HEATER ASSEMBLY SHALL BE PROVIDED WITH A HIGH TEMPERATURE LIMIT CONTROLER LIMIT CONTROLER WITH A MANUAL RESET. AND WITH A SWITCH TO SHUT DOWN HEATER ON NO AIR FLOW CONDITION. 15. THE WORK SHALL BE PERFORMED ACCORDING WITH ALL APPLICABLE STANDARDS AND REGULATIONS. 16. PROVIDE A CONDENSATE DRAIN RUNNING TO APPROVED DRAIN. THE CONDENSATE DRAIN SYSTEM SHALL MEET THE LOCAL PLUMBING CODE REQUIREMENTS. 17. PROVIDE ELECTRICAL DISCONNECTS FOR THE AIR HANDLER AND CONDENSING UNIT. THE SIZE OF THE DISCONNECT SHALL COMPLY WITH THE EQUIPMENT MANUFACTURER'S REQUIREMENT. 18. PROVIDE ALL NECESSARY INSTRUCTIONS TO THE OWNER IN THE OPERATION OF THE MECHANICAL SYSTEMS. 19. INTERLOCK ELECTRIC DUCT HEATERS WITH COMPRESSOR CIRCUIT SO THAT HEATERS DO NOT OPERATE SIMULTANEOUSLY WITH COMPRESSORS. AC EQUIPMENT SCHEDULE UNIT DESIGNATION AHU #1 CHECKED BY: CU #1 AREA SERVED 726 S.F. MANUFACTURE RHEEM OR EQUAL MANUFACTURE MANUFACTURING COMPANY MANUFACTURE'S AHU = RHLA- HM3617JA MODEL NO. (RCSA(L) -H M3017JA MODEL NO. CU - 1 4AJ M30AO 1 SEER /EER 14 TYPE DX -SPLIT LOCATION GROUND OPERATING AHU -921bs WEIGHT LBS CU- 1571bs NOMINAL TONS 2.5 NOMINAL SUPPLY - AIR CFM 950 OUTSIDE AIR CFM 100 (INFILTRATION) TOTAL CAPACITY, 28,400 B.T.U.H. - TOTAL SENSIBLE, 20,400 B.T.U.H. - ENTERING AIR 76.8/61.9 TEMP DB /WB. F - LEAVING AIR TEMP 55.7/52.8 DB. /WB. F. - HEATING COIL TYPE ELECTRIC TOTAL HEATING 7.2 CAPACITY, KW 7.2 CAPACITY. KW 1 NUMBER OF STEPS 1 ELECTRIC SERVICES 1 PHASE 60 HZ V /PH /HZ 208 - 230/1/60 MINIMUM CIRCUIT AHU - 2.63 AMPAC17Y. CU - 2.69 NUMBER OF 1 COMPRESSORS 12 -13/16 DIMENSION AHU -16 "x22 "x45" WXLXH IN. CU =32 "x32 "x28" WXLXH IN. AMBIENT AIR 95 TEMP F. 95 TEMP F. BLOWER MOTOR - HORSEPOWER (HP) 1/2 CONDENSATE RETURN & FREON LINES UNDER SLAB 4" PVC SLEEVE 3/8 succ -1 /4w uQ. w/ 114 I1�VrSULATION 2 COND. DRAIN FLOOD ELEV.- X ZONE C.U. PAD ELEV.- AC EQUIPMENT SCHEDULE UNIT DESIGNATION AHU #2 CHECKED BY: CU #2 AREA SERVED BEDROOM MANUFACTURE MITSUBISHI ELECTRIC MANUFACTURE'S AHU= MSZ- GA24NA RPM CU- MUZ- GA24NA MODEL NO. VOLTS /PH/Hz SEER /EER 17.5 TYPE DX -SPLIT HEAT PUMP LOCATION GROUND OPERATING AHU -221bs WEIGHT LBS CU -771bs NOMINAL TONS 22,000 BTU's NOMINAL SUPPLY AIR CFM - OUTSIDE AIR CFM - TOTAL CAPACITY. 22,000 B.T.U.H. TOTAL SENSIBLE. - B.T.U.H. ENTERING AIR - TEMP DB /WB. F LEAVING AIR TEMP - DB. /WB. F. HEATING COIL TYPE - TOTAL HEATING BACK DRAFT DAMPER. 7.2 CAPACITY, KW NUMBER OF STEPS 1 ELECTRIC SERVICES 208/230v. V /PH /HZ 1 PHASE 60 HZ MINIMUM CIRCUIT AHU - 60.0 AAPACITY. CU - 30.0 NUMBER OF 1 COMPRESSORS AHU -43- 5/16x10 -1/4 "x 12 -13/16 DIMENSION CU -33 -1 /16 "x13% WXLXH IN. 33 -7/16" AMBIENT AIR 95 TEMP F. BLOWER MOTOR HORSEPOWER (HP) - UNDERGROUND - REFRIGERANT LINE C.U. j � #2 I I CONDENSING DRAIN 6" NOTE: MECHANICAL CONTRACTOR WILL COORDINATE WITH PLUMBING CONTRACTOR CONDENSATE SYSTEM INSTALLATION (TO BE PROVIDED AND INSTALLED BY PLUMBING CONTRACTOR) ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 2007 "MECHANICAL" 2ND FLOOR - SEAL W /PITCH FINISH GRADE- ONE LENGTH OF 10" DIA. x 24" DEEP (MI CONCRETE PIPE - 8N AHU- TWV036B140 u CU- TrNO3OC100 12w oa n 0%4 • . .c 4 0 0 - `alm . ("WASHED ROCK -) A/C CONDENSATE DRYWELL SCALE: N.T.S. E PFM 22.000 BTUH CLG b SA AHU #2 BATH No.2 BEDROOM #2 FAN SCHEDULE YES MANUFACTURER DUCT SMOKE DETECTORS CHECKED BY: X ELECT. SERVICE DIMENSIONS WEIGHT SMOKE DAMPERS(S) FAN # AND MODEL NO. RPM HP CFM 8" S.P. VOLTS /PH/Hz WxLxH (IN.) LBS. REMARKS ; - - - E BATHROOMS GREENHECK SP -6 -QD 1500 1/20 60 0 .125" 120/ 1/ /60 DIRECT 10 4"N SM DUCT UP TO ROOF ; CAP 26 GA ALUM. AS PER- - FBC 2007 603.3 BACK DRAFT DAMPER. AIR - COOLED CONDENSING UNIT - SLAB MOUNTED 1. CONDENSING UNIT 2. COMPRESSOR ACESS PANEL 3. BACK - SEATED REFRIGERANT VALVE 4. REFRIGERANT SUCTION LINE WITH INSULATION 5. SIGHT GLASS WITH MOISTURE INDICATOR 6. REFRIGERANT LIQUID LINE 7. CONDUIT - POWER AND CONTROL. 8. REFRIGERANT GAUGE CONNECTION 9. CONDENSER COIL 10. COIL GUARD 11. FAN GUARD 12. CONCRETE PAD IF REQUIRED 13. REFRIGERANT SUCTION LINE FLEX - CONNECTOR HVAC DESIGN REQUIRES YES NO DUCT SMOKE DETECTORS CHECKED BY: X FIRE DAMPER(S) 03 -0010 X SMOKE DAMPERS(S) X FIRE RATED ENCLOSURE X FIRE RATED ROOF /FLOOR CEILING ASSEMBLY X FIRE STOPPING X SMOKE CONTROL X 6" 0. 26 GA. DUCT THRU ROOF 75 CFM EXHAUST W/D INSULATE DUCTS MIN. R -6.0 DUCT LENGTH MAX= 15' -O" 1" UNDERCUT ALL DOORS 14. INSTALL STAINLESS STEEL 1/8- DIAM. CABLE ACROSS CONDENSING UNIT AND FASTEN SECURELY TO STAND FRAME & CONC. SLAB 15. CONDENSING UNIT TO BE ABOVE FLOOD ELEVATION LEVEL 16. PROVIDE 1/4- CONC. SCREWS SNUG TO BASE PAN LENGTH TO PENETRATE CONC. 1.5" MIN. 1/4" LAG SCREW SNUG TO BASE PAN LENGTH TO PENETRATE METAL 1.5" MIN., SCREWS HAVE TO PLACED ON THE BASE PAN AS SHOWN UNLESS OTHERWISE SPECIFIED. LIVING AREA DINING D PROVIDE a z ROOF ROOF CURB o 5 BACKDRAFT DAMPER EXHAUST FAN--x FROM LIGHT SWITCH TOILET CEILING TOILET EXHAUST FAN DETAIL SCALE: N.T.S. I- --� SITTING I 1 p" 4 17 .10" �p 0 FN T RA PROGRAMMABLE 12" 8 "x18" 6" THERMOSTAT T RAG MIN. CONDENSING % "x 18" DRAIN 0ja!RAG /10N #1 10' Q r9m SHEET TITLE SDCFM a b IGUILLERMO RAMON GONZALEZ 9000 S.W. 165TH AV MIAMI. FL. 33195 (305) 484 -8171 GUILLERMO R. GONZALEZ FL. REGIST. # AR13960 V) �. �n PROJECT NAME ZASLOW REMODELING 6200 SW 78TH ST SOUTH MIAMI, FLA 33143 U U STE �- UNDERGROUND REFRIGERANT LINE KITCHEN TH MASTER BR O AIR CONDITIONING PLAN SCALE: 1/409=1@-O" sa r2&mQ. a INA mil CONDENSATE RETURN & FREON LINES UNDER SLAB 4" PVC SLEEVE 3/4" SUCT -5 16" UQ. 114" INSULATION 2 COND. DRAIN MECHANICAL FLOOR PLAN SPECS AND NOTES °ate' 06/20/10 DRAWN BY: G.G. CHECKED BY: G.G. Job No. 03 -0010 SHEET NO. M -1