10-722-016SUPPLY AIR DUCT
TURNING VANED
NEOPRENE PAD
VIBRATION ISOLATER
PROVIDE 3 "x3"
GALVANIZED ANGG
ANGLE W / #8 SCREWS
® 6" O.C. TO DUCT
MECHANICAL ATTACHED
A.H.U. AS PER FBCR-
M 1601.6.2.2
AIR HANDLER UNIT-
FLOAT SWIM
DRAIN PAN
RETURN AIR
FL00 R--i
SUPPLY AIR
GAS LINE AND
LIQUID LINE TO
CONDENSING UNIT
,TI►G7�1:7:�G
FILTER
METAL STAND
CONDENSATE DRAIN TO
TERMINATE 6" ABOVE
GRADE, OR TO DRAIN
AHU MOUNTING DETAIL
AIR CONDITIONING SYSTEM GENERAL NOTES
(IF APPLICABLE)
1. WORK INCLUDED: PROVIDING HEAT. VENTILATION, AND AIR CONDITIONING SYSTEMS WHERE SHOWN
ON THE DRAWING, AS SPECIFIED HEREIN, AND AS NEEDED FOR A COMPLETE AND PROPER INSTALLATION
INCLUDING, BUT NOT NECESSARILY LIMITED TO
• AIR CONDITIONING SUPPLY AND RETURN DUCTWORK SYSTEM WITH GRILLES. DIFFUSERS. AND REGISTERS.
• AIR CONDITIONING UNITS, PIPING AND COMPONENTS, OPERATING AND SAFETY CONTROLS, BLOWERS,
MOTORS, FILTERS. AND RELATED ITEM.
* EXHAUST SYSTEMS INCLUDING TOILET FANS. MOTORS. DUCTWORK. FRILLES. REGISTERS. CONTROLS. AND
REGISTERS.
• TEMPERATURE CONTROL SYSTEM INCLUDING LOW VOLTAGE WIRING.
• THERMAL INSULATION OF DUCTS AND PIPING.
2.
KNAUF AIR DUCT TYPE EI -475 FIBERGLASS WITH VAPOR BARRIER. DUCT WORK BETWEEN FLOORS,
ENCLOSED ATTACHED GARAGES, UNCONDITIONED BASEMENT, UNCONDIRIONED INTERIOR SPACES, AND
ROOF WITH MIN R -12 INSULATION SHALL BE R -4.3 KNAUF AIR DUCT FIBERGLASS TYPE E1800 WITH
VAPOR BARRIER. UNLESS OTHERWISE SPECIFIED DUCTWORK SHALL BE FABRICATED AND INSTALLED IN
ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS AND ACCORDING TO " ASHRAE" AND
"NAIMA" STANDARDS, AND 2004 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION.
ALL OUTSIDE DUCTWORK SHALL BE GALVANIZED STEEL, DESIGND, CONSTRUCTED, INSTALLED AND TESTED
IN ACCORDANCE WITH LATEST EDITION OF "SMACNA ". DUCTWORK TO HAVE MANUFACTURE'S GUAGE
STAMP. PROVIDE CROSS BREAKING OR BEADING TO PREVENT FLEXING. BUT DO NOT REDUCE GUAGE OF
METAL BELOW THAT REQUIRE FOR FLAT DUCTWORKI. ALL EXTERIOR DUCTWORK SHALL BE SEALED TO 100%
CLOSURE WITH APPROVE CLOSURE SYSTEMS.
DUCTWORK ON ATTICS SPACE AND ROOF WITH LESS THAN R -12 INSULATION SHALL BE 1 -1/2" THICK R -6.5,
ALL DUCTWORK SHALL BE METAL FABRICATED AND INSTALLED IN ACCORDANCE WITH
MANUFACTURE'S SPECIFICATIONS AND ACCORDING TO ASHRAE AND SMACNA STANDARDS, AND
1993 SOUTH FLORIDA ENERGY CODE FOR BUILDING CONSTRUCTION.
SHALL COMPLY WITH "NFPA" STANDARD No. 90A AND /PR 90B DUCTWORK AND COMPONENTS S
SHALL BE CLASS 1 MATERIALS IN ACCORDANCE WITH U.L. 181 TESTS. FIBERGLASS DUCT SYSTEM STRAIGHT
SECTIONS AND FITTINGS SHALL BE REINFORCED BY EITHER OR BOTH OF THE FOLLOWING METHODS:
A) TIE ROD REINFORCEMENT AND OR B) CHANNEL REINFORCEMENT. REFER TO THE FIBROUS GLASS DUCT
CONSTRUCTION STANDARDS AND MANUFACTURER RECOMMENDATION. LOGITUDINAL SEAMS AND TRANSVERSE
JOINTS CLOSURES SHALL COMPLY WITH UL 181 A/P )PRESSURE SENSITIVE ALUMINUM FOIL TAPE) OR
181 A/H (HEAT SELLABLE ALUMINUM FOIL TAPE OR MANUFACTURER'S RECOMMENDATIONS FOR THE USE OF
GLASS FABRIC AND MASTIC. DUCT SUPPORT SHALL BE PLACED SO AS TO PROPERLY SUPPORT ALL
FITTINGS AND ACCESSORIES WITHOUT PLACING THE TAPED JOINTS UNDER STRESS.
3. COORDINATE LOCATIONS, SIZES AND OPENINGS WITH OTHER TRADES ON THE JOB. A/C CONTRACTOR SHALL
DAMPERS AS REQUIRED OR SHOWN ON THE DRAWING.
DUCT DIMENSIONS ARE IN INCHES AND CORRESPOND TO INSIDE DIMENSIONS. WITH x HEIGHT. DUCT SYSTEM
4. DIFFUSERS SHALL BE SELECTED. LOCATED AND BALANCED IN ORDER THAT THEY DELIVER THE REQUIRED CFM
TO THE ENTIRE ROOM EVENLY AND DRAFT FREE TO THE FOLLOWING DESIGN CONDITIONS.
INSIDE OUTSIDE RELATIVE HUMIDITY
COOLING - 78 dB 91 dB -79 wB 50% TO 60%
HEATING - 72 dB
5. OBJECTIONABLE SOUND WILL BE HEARD IN THE HABITABLE SPACES DUE TO AIR VELOCITY, MOTOR HUM,
VIBRATION OR MECHANICAL MOVEMENT.
PROVIDE THE COMPLETE DUCT SYSTEM WITH TURNING VANES AT ALL ELBOWS, AND INSTALLED SPLINTERS AND
6. A/C SYSTEM SHALL HAVE 1- AIR FILTERS AS SPECIFIED LOCATION AND AS REQUIRED FOR EASY ACCESSIBILITY.
7. A/C SYSTEM SHALL BE CONTROLED BY A THERMOSTAT MOUNTED 5' ABOVE FINISH FLOOR.
8. ALL GRILLES AND DIFFUSERS TO BE ALUMINUM CONSTRUCTION. ALL DIFUSERS SHALL HAVE HIDEN OPPOSED
BLADE DAMPERS. PROVIDE GASKETS ON ALL GRILLES AND DIFFUSERS.
9. UNDERCUT DOORS A.F.F. AS INDICATED
10. ALL REFRIGERANT PIPING SHALL BE COPPER HARD DRAWN TYPE - L -ACR, DEHYDRARED AND SEALED.
ALL FAN. MOTORS, COMPRESSORS, ETC. SHALL BE ISOLATED, AS REQUIRED TO OPERATE QUIETLY SO THAT NO
OF NOT LESS THAN 5% SILVER. PIPING INSULATION NOT LESS THAN 3/4" THICK "ARMAFLEX ". LIQUID
AND SUCTION LINES SHALL BE SIZED ACCORDING TO EQUIPMENT MANUFACTURER'S RECOMMENDATION
FOR EQUIVALENT LENGTH OF PIPING RUN FOR CONNECTED TONNAGE. ALL PIPING ACCESSORIES SHALL BE
CONSTRUCTED AS SUGGESTEDD BY EQUIPMENT MANUFACTURER. PROVIDE FILTER /DRYER AND SIGHT GLASS
ON LIQUID LINE. REFRIGERANT PIPING SYSTEM SHALL BE COMPLETED EVACUATED TO 26" VACUUM OF
MERCURARY GUAGE PRESSURE USING A VACUUM PUMP AND HOLD FOR A MINIMUM OF 24 HOURS.
COMPRESSORS SHALL NOT BE USED TO EVACUATED SYSTEMS. CHANGE THE OIL IN THE VACUUM PUMP
BEFORE VACUUM IS PULL. VACUUM SHALL BE BROKEN WITH THE OPENING REFRIGERANT.
11. ALL VENTILATION DUCTWORK SHALL BE SHEETMETAL INSTALLED ACCORDING TO LAST EDITION OF
"SMACNA" AND " ASHRAE" FOR LOW PRESSURE DUCT SYSTEM. FLEXIBLE DUCT SHALL BE CLASS
1 U.L. LISTED, PROVIDE FOSTER 32 -50 AT ALL SHEETMTAL DUCT CONNECTIONS.
THE CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER TRADES.
12. FITTINGS SHALL BE WROUGHT COPPER. ALL JOINTS SHALL BE MADE WITH HIGH TEMPERATURE BRAZING ALLOY
13. THE CONTRACTOR SHALL THOROUGHLY EXAMINE THE SITE, SATISFY HIMSELF TO EXISTING CONDITIONS
UNDER WHICH THE WORK IS TO BE PREFORMED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
ANY FIELD CONDITION AFFECTING HIS WORK.
14. ELECTRIC HEATERS: SHALL BE MOUNTED IN BOX CASING WITH CAPACITIES AS SHOWN IN THE SCHEDULE.
HEATERS TO BE U.L. LABELED AND LISTED FOR ZERO CLEARANCE AS A DUCT HEATER. ELEMENTS TO BE
OPEN TYPE GRADE A NICHROME WIRE. EACH HEATER ASSEMBLY SHALL BE PROVIDED WITH A HIGH
TEMPERATURE LIMIT CONTROLER LIMIT CONTROLER WITH A MANUAL RESET. AND WITH A SWITCH TO SHUT
DOWN HEATER ON NO AIR FLOW CONDITION.
15. THE WORK SHALL BE PERFORMED ACCORDING WITH ALL APPLICABLE STANDARDS AND REGULATIONS.
16. PROVIDE A CONDENSATE DRAIN RUNNING TO APPROVED DRAIN. THE CONDENSATE DRAIN SYSTEM SHALL
MEET THE LOCAL PLUMBING CODE REQUIREMENTS.
17. PROVIDE ELECTRICAL DISCONNECTS FOR THE AIR HANDLER AND CONDENSING UNIT. THE SIZE OF THE
DISCONNECT SHALL COMPLY WITH THE EQUIPMENT MANUFACTURER'S REQUIREMENT.
18. PROVIDE ALL NECESSARY INSTRUCTIONS TO THE OWNER IN THE OPERATION OF THE MECHANICAL SYSTEMS.
19. INTERLOCK ELECTRIC DUCT HEATERS WITH COMPRESSOR CIRCUIT SO THAT HEATERS DO NOT OPERATE
SIMULTANEOUSLY WITH COMPRESSORS.
AC EQUIPMENT
SCHEDULE
UNIT DESIGNATION
AHU #1
CHECKED BY:
CU #1
AREA SERVED
726 S.F.
MANUFACTURE
RHEEM OR EQUAL
MANUFACTURE
MANUFACTURING COMPANY
MANUFACTURE'S
AHU = RHLA- HM3617JA
MODEL NO.
(RCSA(L) -H M3017JA
MODEL NO.
CU - 1 4AJ M30AO 1
SEER /EER
14
TYPE
DX -SPLIT
LOCATION
GROUND
OPERATING
AHU -921bs
WEIGHT LBS
CU- 1571bs
NOMINAL TONS
2.5
NOMINAL SUPPLY
-
AIR CFM
950
OUTSIDE AIR CFM
100 (INFILTRATION)
TOTAL CAPACITY,
28,400
B.T.U.H.
-
TOTAL SENSIBLE,
20,400
B.T.U.H.
-
ENTERING AIR
76.8/61.9
TEMP DB /WB. F
-
LEAVING AIR TEMP
55.7/52.8
DB. /WB. F.
-
HEATING COIL TYPE
ELECTRIC
TOTAL HEATING
7.2
CAPACITY, KW
7.2
CAPACITY. KW
1
NUMBER OF STEPS
1
ELECTRIC SERVICES
1 PHASE 60 HZ
V /PH /HZ
208 - 230/1/60
MINIMUM CIRCUIT
AHU - 2.63
AMPAC17Y.
CU - 2.69
NUMBER OF
1
COMPRESSORS
12 -13/16
DIMENSION
AHU -16 "x22 "x45"
WXLXH IN.
CU =32 "x32 "x28"
WXLXH IN.
AMBIENT AIR
95
TEMP F.
95
TEMP F.
BLOWER MOTOR
-
HORSEPOWER (HP)
1/2
CONDENSATE RETURN &
FREON LINES UNDER SLAB
4" PVC SLEEVE 3/8
succ -1 /4w uQ. w/
114 I1�VrSULATION
2 COND. DRAIN
FLOOD ELEV.- X ZONE
C.U. PAD ELEV.-
AC EQUIPMENT
SCHEDULE
UNIT DESIGNATION
AHU #2
CHECKED BY:
CU #2
AREA SERVED
BEDROOM
MANUFACTURE
MITSUBISHI ELECTRIC
MANUFACTURE'S
AHU= MSZ- GA24NA
RPM
CU- MUZ- GA24NA
MODEL NO.
VOLTS /PH/Hz
SEER /EER
17.5
TYPE
DX -SPLIT HEAT PUMP
LOCATION
GROUND
OPERATING
AHU -221bs
WEIGHT LBS
CU -771bs
NOMINAL TONS
22,000 BTU's
NOMINAL SUPPLY
AIR CFM
-
OUTSIDE AIR CFM
-
TOTAL CAPACITY.
22,000
B.T.U.H.
TOTAL SENSIBLE.
-
B.T.U.H.
ENTERING AIR
-
TEMP DB /WB. F
LEAVING AIR TEMP
-
DB. /WB. F.
HEATING COIL TYPE
-
TOTAL HEATING
BACK DRAFT DAMPER.
7.2
CAPACITY, KW
NUMBER OF STEPS
1
ELECTRIC SERVICES
208/230v.
V /PH /HZ
1 PHASE 60 HZ
MINIMUM CIRCUIT
AHU - 60.0
AAPACITY.
CU - 30.0
NUMBER OF
1
COMPRESSORS
AHU -43- 5/16x10 -1/4 "x
12 -13/16
DIMENSION
CU -33 -1 /16 "x13%
WXLXH IN.
33 -7/16"
AMBIENT AIR
95
TEMP F.
BLOWER MOTOR
HORSEPOWER (HP)
-
UNDERGROUND -
REFRIGERANT LINE
C.U. j �
#2 I I
CONDENSING
DRAIN 6"
NOTE:
MECHANICAL CONTRACTOR WILL COORDINATE
WITH PLUMBING CONTRACTOR CONDENSATE
SYSTEM INSTALLATION (TO BE PROVIDED AND
INSTALLED BY PLUMBING CONTRACTOR)
ALL WORK SHALL BE PERFORMED IN
ACCORDANCE WITH THE FLORIDA BUILDING
CODE 2007 "MECHANICAL"
2ND FLOOR -
SEAL W /PITCH
FINISH GRADE-
ONE LENGTH OF 10"
DIA. x 24" DEEP (MI
CONCRETE PIPE -
8N
AHU- TWV036B140 u
CU- TrNO3OC100
12w
oa
n
0%4 • .
.c
4
0 0 -
`alm .
("WASHED
ROCK -)
A/C CONDENSATE DRYWELL
SCALE: N.T.S.
E PFM
22.000 BTUH CLG
b
SA
AHU
#2
BATH
No.2
BEDROOM #2
FAN SCHEDULE
YES
MANUFACTURER
DUCT SMOKE DETECTORS
CHECKED BY:
X
ELECT. SERVICE
DIMENSIONS
WEIGHT
SMOKE DAMPERS(S)
FAN #
AND MODEL NO.
RPM
HP
CFM 8" S.P.
VOLTS /PH/Hz
WxLxH (IN.)
LBS.
REMARKS ; - - -
E
BATHROOMS
GREENHECK SP -6 -QD
1500
1/20
60 0 .125"
120/ 1/ /60
DIRECT
10
4"N SM DUCT UP TO ROOF ;
CAP 26 GA ALUM. AS PER- -
FBC 2007 603.3
BACK DRAFT DAMPER.
AIR - COOLED CONDENSING
UNIT - SLAB MOUNTED
1. CONDENSING UNIT
2. COMPRESSOR ACESS PANEL
3. BACK - SEATED REFRIGERANT VALVE
4. REFRIGERANT SUCTION LINE WITH
INSULATION
5. SIGHT GLASS WITH MOISTURE
INDICATOR
6. REFRIGERANT LIQUID LINE
7. CONDUIT - POWER AND CONTROL.
8. REFRIGERANT GAUGE CONNECTION
9. CONDENSER COIL
10. COIL GUARD
11. FAN GUARD
12. CONCRETE PAD IF REQUIRED
13. REFRIGERANT SUCTION LINE
FLEX - CONNECTOR
HVAC DESIGN REQUIRES
YES
NO
DUCT SMOKE DETECTORS
CHECKED BY:
X
FIRE DAMPER(S)
03 -0010
X
SMOKE DAMPERS(S)
X
FIRE RATED ENCLOSURE
X
FIRE RATED ROOF /FLOOR
CEILING ASSEMBLY
X
FIRE STOPPING
X
SMOKE CONTROL
X
6" 0. 26 GA. DUCT
THRU ROOF 75 CFM EXHAUST
W/D
INSULATE DUCTS MIN. R -6.0
DUCT LENGTH MAX= 15' -O"
1" UNDERCUT ALL
DOORS
14. INSTALL STAINLESS STEEL
1/8- DIAM. CABLE ACROSS
CONDENSING UNIT AND
FASTEN SECURELY TO
STAND FRAME & CONC. SLAB
15. CONDENSING UNIT
TO BE ABOVE FLOOD
ELEVATION LEVEL
16. PROVIDE 1/4- CONC. SCREWS SNUG TO
BASE PAN LENGTH TO PENETRATE CONC.
1.5" MIN. 1/4" LAG SCREW SNUG TO
BASE PAN LENGTH TO PENETRATE METAL
1.5" MIN., SCREWS HAVE TO PLACED ON
THE BASE PAN AS SHOWN UNLESS
OTHERWISE SPECIFIED.
LIVING AREA
DINING
D
PROVIDE
a z ROOF ROOF CURB
o
5
BACKDRAFT DAMPER
EXHAUST FAN--x
FROM LIGHT
SWITCH
TOILET CEILING
TOILET
EXHAUST FAN DETAIL
SCALE: N.T.S.
I- --� SITTING
I 1 p" 4 17
.10" �p
0 FN
T
RA PROGRAMMABLE 12" 8 "x18" 6"
THERMOSTAT T RAG MIN.
CONDENSING
% "x 18" DRAIN
0ja!RAG /10N #1
10' Q
r9m SHEET TITLE
SDCFM a b
IGUILLERMO
RAMON
GONZALEZ
9000 S.W. 165TH AV
MIAMI. FL. 33195
(305) 484 -8171
GUILLERMO R. GONZALEZ
FL. REGIST. # AR13960
V) �.
�n
PROJECT NAME
ZASLOW
REMODELING
6200 SW 78TH ST
SOUTH MIAMI, FLA 33143
U U STE �- UNDERGROUND
REFRIGERANT LINE
KITCHEN TH MASTER BR
O
AIR CONDITIONING PLAN
SCALE: 1/409=1@-O"
sa
r2&mQ.
a INA
mil
CONDENSATE RETURN &
FREON LINES UNDER SLAB
4" PVC SLEEVE 3/4"
SUCT -5 16" UQ.
114" INSULATION
2 COND. DRAIN
MECHANICAL
FLOOR PLAN
SPECS AND
NOTES
°ate'
06/20/10
DRAWN BY:
G.G.
CHECKED BY:
G.G.
Job No.
03 -0010
SHEET NO.
M -1