10-722-015SANITARY SEWER AND WATER LINES 3. ALL SANITARY SEWER LINE WHICH ARE 2" MUST SLOPE 1/4- PER FOOT. (AS PER FBC R P3005.3) HOT WATER PIPE (HW) EXCEPT OTHERWISE NOTED CONDENSATE DRAIN PIPE (CD) 4. ALL SANITARY SEWER LINE WHICH ARE 3" MUST SLOPE 1/8" PER FOOT. (AS PER FBC R P3005.3) INDIRECT SAFE WASTE PIPE (" EXCEPT OTHERWISE NOTED w Pro osed Plumbic SCALE: 1 /4 " =1 * -O" r Plan 0 z PLUMBING LEGEND SYMBOL DESCRIPTION - - COLD WATER PIPE (CW) - - - - HOT WATER PIPE (HW) P-1 CONDENSATE DRAIN PIPE (CD) 7 w PRESSURE 8 TEMPERATURE RELIEF PIPE (PT) FLOOR MOUNTED. FLUSH TANK P-Z INDIRECT SAFE WASTE PIPE (" Iw w SANITARY WASTE PIPE (81W) COUNTERTOP - - - - - - - - - - SANITARY VENT PIPE (V) 2' WATER HAMMER ARRESTOR AND TYPE I I WALL CLEAN OUT (CO) I AIR ADMITTANCE VALVE (AAV) ® FLOOR CLEAN OUT (FCO) N CHECK VALVE oa GATE VALVE GATE VALVE IN VERTICAL. v i' HOSE BIBS WITH SHUTOFF VALVE & VB (HB) ® VALVE IN BOX 1 w CD WATER METER MM) lr- c- 'P TRAP C PIPE DOWN (DN) 0 PIPE UP (UP) ® ROOF DRAIN (RD) ® AREA DRAIN (AD) FLOOR DRAIN (FD) Q FLOOR SINK (FS) BACK FLOW PREVENT ER (BFP) .L TRAP PRIMER (TP) CONNECT TO EXISTING UG UNDERGROUND VB VACUUM BREAKER VTR VENT THRU ROOF RWL RAM WATER LEADER FU FDCTURE UNIT CLA CE ILMO ECT TO SEWER IN LINE TANKLESS H.W.H TITAN —SCR2, N -120 TANKLESS WATER HEATER DETAIL NOT TO SCALE PLUMBING FIXTURE CONNECTION SCHEDULE MARKS DESCRIPTION WASTE C.W. H.W. REMARIGSPECS P-1 WATER CLOSET 7 w - FLOOR MOUNTED. FLUSH TANK P-Z LAVATORY Iw w w COUNTERTOP P-3 KITCHEN SINK 2' P-4 WASHER 21 PROVIDE SUPPLY AND DRAIN IN RECESSED BOX REF REFRIGERATOR '1S CONNECT TO ICE MAKER AHU AIR HANDLING UNIT 1 w CD - - SPECIFICATIONS: 1. ALL WORK TO BE DONE IN ACCORDANCE WITH THE FLORIDA BUILDING _CODE. STATE AND LOCAL ORDINANCES. : - - - _ - 2 BUILDING DRAINAGE SYSTEM TO BE SLOPED AT IlAr PER FT. IHltlii:FALLFOR 3' FIRE AND LARGER VO PER FT. SLOPE FOR 27 PIPE SI21E AND SMALLER DEVIATIONS SHALL BE APPROVED BY ARCHITECTIENGINEER. 3. 4. PROVIDE CLEAN OUTS EVERY 75 FT. AND AT BASE OF EVERY WASTESTACK. ALL CLOSE -OUTS TO BE FLUSH MOUNTED. MATERIALS SHALL BE ALL NEW AND AS FOLLOWS: A. DRAINAGE WASTE AND VENT PIPING INCLUDING: PVC DRAINAGE WASTE AND PIPING (DWI) CONFORMING TO ASTM D -2885, UNDERGROUND NO HUB CAST IRON CISPI STANDARD 301 ABOVE GROUND AND CAST IRON HUB. PLAIN END ASTM A-74 WITH NEO- PRENE GASKETS UNDERGROUND. INSTALL PLASTIC (PVC) PIPES ONLY WHEN ITS APPROVED BY LOCAL AUTHORITIES AND NOT TO BE USED IN AIR RETURN PLENUM. B. WATER PIPING: COPPER TYPE RV ASTM B488 ABOVE GROUND AND COPPER TYPE 9C' ASTM BBB UNDERGROUND. C. CONDENSATE DRAIN PIPING: COPPER TYPE wW ASTM 8-88 INSIDE THE BUILDING AND PVC SCHEDULE 40 ABOVE ROOF AND UNDERGROUND. PROVIDE 1/2' ARMAFLEX PIPE INSULATION TO ALL CONDENSATE DRAIN PIPING. D. FLOOR CLEAN OUTS: JOSAM SERIES 68020 OR EQUAL E. WALL CLEAN OUTS: JOSAM SERIES 58750 WITH ACCESS COVER OR EQUAL F. VALVES: 125 PSI NIBCO SCOTT, STOCIWAM OR EQUAL G. HOSE BIBBS: CHICAGO 837 OR EQUAL WITH VACUUM BREAIG=R. 5. H. AIR ADMITTANCE VALVE: STUDORM MINI -VENTO OR APPROVED EQUAL. PERFORM THE FOLLOWING TEST. A. WATER PIPING SHALL BE SUBJECTED TO HYDROSTATIC PRESSURE TEST OF 100 PSIG FOR A PERIOD OF TIME SUFFICIENT TO EXAMINE ENTIRE SYSTEM BUT NOT LESS THAN ONE HOUR. B. DRAINAGE SYSTEM: BEFORE INSTALLATION OF ANY DRAINS, THE END OF THE SYSTEM SHALL BE CAPPED & ALL LINES FILLED WITH WATER TO HIGHEST POINT & ALLOWED TO STAND UNTIL INSPECTION IS MADE AND WATER LEVELS REMAIN CONSTANT. C. CORRECT ALL DEFECTS DISCLOSED BY ABOVE TESTS. D. COMPLETE SYSTEM FIXTURE & EQUIPMENT SHALL BE GIVEN AN IN- SERVICE TEST AFTER COMPLETION OF THE INSTALLATION. E. STERILIZE ALL WATER LINES WITH A MDMRE OF (2) POUNDS OF CHLORINATED LIME TO EACH 1000 gal. OF WATER (50 PPM OF AVAILABLE CHLORINE.) RETAIN 8. MDCTURE IN PIPES FOR 24 HOURS AND FLUSH THOROUGHLY WITH POTABLE WATER BEFORE PLACING IN SERVICE. PLUMBING CONTRACTOR SHALL FURNISH A WRITTEN GUARANTEE THAT ALL 7. PLUMBING WORK SHALL BE FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE. AND THAT HE WILL. AT HIS EXPENSE, REPAIR AND REPLACE ALL WORK WHICH S. BECOMES DEFECTIVE DURING GUARANTEE PERIOD. 9. CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION OF EXISTING UTILITIES AND POINTS OF CONNECTION BEFORE COMMENCING ANY WORK 10. PLUMBING CONTRACTOR SHALL PAY ALL FEES, INSPECTION AND CONNECTION CHARGES REQUIRED. 11. SUBMIT SHOP DRAWINGS TO ENGINEER FOR APPROVAL OF ALL EQUIPMENT, MATERIALS AND LAYOUTS PRIOR INSTALLATION. 12. OFFSET PIPING AS REQUIRED TO CLEAR BUILDING STRUCTURE. DUCTWORK. ETC. AS SHOWN ON DRAWINGS AND AS REQUIRED BY FIELD CONDITIONS. 18. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL A/C CONDENSATE DRAIN AND TRAP. SEE A/C PLANS FOR LOCATION OF UNITS AND DRAINS. 14. PLUMBING CONTRACTOR SHALL VERIFY ALL SPACE CONDITIONS AND DIMENSIONS 15. AT JOB SITE PRIOR TO FABRICATION AND INSTALLATION OF MATERIALS AND EQUIPMENT. 18. 17. COORDINATE WORK WITH OTHER TRADES. FURNISH AND INSTALL FIXTURES AS SPECIFIED IN PLUMBING FDCTURE SCHEDULE. EACH BATHROOM GROUP SHALL BE PROVIDE WITH WATER HAMMER ARRESTORS AS PER FBC 604.9. PROVIDE SHUTOFF VALVE FOR EACH FIXTURE, JUST BEFORE CONNECTING TO FIXTURE. WHEREVER DISSIMILAR METALS ARE TO BE JOINED, A DIELECTRIC FITTING SHALL BE PROVIDED TO CONNECT BOTH TYPES OF PIPES. IG U I LLER M O RAMON IG O N ZALEZ 9000 S.W. 16871-1 AV MIAMI, FL. -3,3195 (305) 484 -8171 GUILLERMO R. GONZALEZ FL. REGIST. # AR9 3960 vi - f PROJECT NAME ZAS LO W REMODELING 6200 SW 78TH ST SOUTH MIAMI, FLA 33143 SHEET TITLE PLUMBING FLOOR PLAN DATE: 06/20/10 DRAWN BY: G.G. CHECKED BY: G.G. JOB NO. 03 -0010 SHEET NO.