14-925-019SCREW" SCR�vvv IvIH i u� OMITTED IF HANGER LOOPS STRAP HANGERS UNLESS FOOT OF TRAP IS PLACED UNDER A BOTTOM REINFORCEMENT FOR LOAD TRAPEZE HANGERS SHEET METAL RUNNER TOP ANf ^TT ^" " SECURED TO DUCT WITH SHEE" SHEET METAL SINGLE THICKNESS QUARTER ROUND TURNING VANES SINGLE VANE SCHEDULE 7 SP 3A. SMALL 2" 1 \" 24 LARGE 4" 3 I " 22 DUCT TURNING VANE DETAIL NT5 UPPER ATTACHMENT PER SMACNA Al V�JKIVLLK CLOSE OPENING 45 DEGREE ENTRY = 45 TYPICAL FABRICATED SHEET METAL ELBOW SHEET METAL SINGLE THICKNESS TURNING VANES WITH FLANGED FASTENERS TOP AND BOTTOM SHEET METAL RUNNER FASTENED DUCT WITH SHEET METAL SCREW; HVAC DUCT CONSTRUCTION STANDARDS ALL DUCTWORK MUST COMPLY WITH SMACNA HVAC DUCT CONSTRUCTION STANDARD AS FOLLOWS: LOW PRESSURE DUCTWORK 2 "W.G, W.(4" MIN) TAPP -OFF WITH VOLUME DAMPER FLEXIBLE DUCT- 8' -0" MAX. 2' -0" MIN, LENGTH MAXIMUM D/8 OFFSET ALLOWED IN LAST D INCHES TO DEVICE WHERE D IS THE INTERNAL FLEX DIAMETER NECK SIZE TO MATCH FLEX DUCT SIZE INDICATED — CEILING (T -BAR SHOWN. GYP. BOARD SIMILAR) NOTES N.T.S. 0 MAX. SAG 1/2" PER FOOT DAMPER L =114 W. (4 MIN) PROJ. No. 23057 G\ X424 LOUIS J. AGUIRRE & ASSOCIATES P.A. CONSULTING ENGINEERS 9150 SOUTH DADELAND BLVD. SUITE 900 MIAMI, FLORIDA 33156 TELEPHONE: (305) 670 -0141 FAX: (305) 670 -0144 E —MAIL ADDRESS: GRALMAILQLJAAPA.COM AT CORNER CLOSE OPENING 45 DEGREE ENTRY 0 = 45 TAPP- -OFF WITH VO UME DAMPER N.T.S. BETWEEN SUPPORT POINTS — DUCT SEALER A F 45- TAKEOFF 45- TAKEOFF OR ROUND OR ROUND BEL MOUTH COLLAR BELLMOUTH COLLAR CONNECTION TO MAIN MOUNT IN SIDE OF DUCT ADJUSTABLE CLAMP SUPPY AIR DUC SADDLE 22 GUAGE GALVINIZED STEEL VOLUME DAMPER W/ LOCKING STRAP HANGER AS PER QUADRANT i 2" S ANDOFF SMACNA FIG. 3 -10 (SEE NOTE u5) ADJUSTABLE CLAMP DUCT SEALER FULLY HINGED ASKETED INSULATE TOP PANEL ACCESSDOOR FOR DAMPERS OF DIFFUSER OR GRILLE IN NON- ACCESSI LE CEILINGS ` AIR DISTRIBUTION DEVICE LAYIN SHOWN. SURFACE MOUNT SIMILAR I. FLEXIBLE DUCTS SHALL BE ONE PIECE AND SHALL NOT BE SPLICED TOGETHER, 2. EXTEND FLEXIBLE DUCT INSULATION TO DUCT /DIFFUSER PANEL INSULATION AND SEAL WITH MASTIC. 3. FLEXIBLE AIR DUCT SHALL NOT EXCEED 8 FT. WHEN EXTENDED . ELBOW RADIUS SIZED FOR NO LESS THAN R / D = 1.0. 4. 24 INCH ORANGE SURVEY TAPE SHALL BE PROVIDED ON ALL DUCT QUADRANT LOCKING LEVERS DIRECTLY ABOVE THE ACCESS PANEL. 5, MINIMUM 1 1/2" WIDE 22 GALVANIZED STRAP HANGER WITH HEMMED EDGES. (FBMC 2004 603,5.6.6) FLEXIBLE DUCT TAKEOFF DETAIL NTS Re�aisi4ns; 0 U A 0 0 a d< A4 r_ w z ° V0 h� 4 o Q u�9�� o W x A PERMIT SET 05/12/14 DRAWN: J_E,_ DATE: 03 -28 -14 SCALL AS NOTED , y1 HANICAD',, UARDO A SUA.REF_j ''��ICENSE ��`64159 Sheet No. M7.00 JOB 201304 I