14-925-004I.- THIS DRAWING 15 ONLY TO A5515T IN SHOWING THE
SCOPE OF DEMOLITION WORK AND 15 NOT
INTENDED TO INDICATE ALL DEMOLITION.
CONTRACTOR SHALL REMOVE ALL EXISTING
ITEMS AS REQUIRED TO COMPLETE THE JOB.
2.- NOT ALL ITEMS TO BE DEMOLISHED ARE
SHOWN ON THE PLAN. CONTRACTOR SHALL BE
RESPONSIBLE FOR PERFORMING A WALK -THRU
10 T
OF THE PROJECT PR R O T SUBMITTING A BID
TO THE OWNER FOR IDENTIFYING POSSIBLE
CRITICAL ITEMS, NOT OR INCORRECTLY
ADDRESSED, WHICH REQUIRE REMOVAL/
RELOCATION,
3.- PROVIDE SAFETY FEATURES DURING WORK AS
CALLED FOR IN SPECS, APPLICABLE CODES,
RULES AND REGULATIONS HAVING JURISDICTION
OF THE PROJECT.
4.- CUT, REMOVE, PATCH, ALTER AND REFINISH
EXISTING CONSTRUCTION AS REQUIRED TO
LEAVE WORK COMPLETE AND IN 5AT15FACTORY
I„IANNER.
a.- CONTRACTOR 15 TO PROTECT ALL UNDER-
GROUND OR OTHER CONCEALED UTILITIES. HE
15 TO INSPECT CEILING AND CHA5E5 TO
ASSURE PROPER IDENTIFICATION OF UTILITIES.
MECHANICAL AND /OR ELECTRICAL_
CONTRACTOR ARE TO CAP THEM AS
REQUIRED.
�.- OPENINGS LEFT THROUGH RATED AND SMOKE
PARTITIONS DUE TO REMOVAL OF DUCTWORK
CONDUIT SHALL BE CLOSED (BOTH SIDES)
-f.- REMOVE ALL EXISTING ACOUSTICAL TILE' CLG.
AND SUSPENDED SYSTEMS IN THE RENOVATION
AREA AS REQUIRED FOR INSTALLATION OF WORK
TO BE DONE. COORDINATE REMOVAL WITH
ELECTRICAL CONTRACTOR REGARDING EXISTING
LIGHTING FIXTURES ETC.. REPLACE CEILING
ACCORDINGLY AFTFR COMPLETION OF WORK.
GsENE iz,41_ 1D E IOL I T I ON NOTE 5:
a.- CONTRACTOR IS TO SAW -CUT ALL OPENINGS IN 10.- CONTRACTOR IS TO COORDINATE
CONCRETE B!_OCIG WALLS IF REQUIRED. CONTRACTOR DEMOLITION WORK WITH ADMINISTRATION AND
SHALL NOT DEMOL15H OPENINGS WITH SLEDGE 15 TO GIVE SUFFICIENT ADVANCE NOTICE OF
HAMMER UNTIL OUTLINES HAVE BEEN CUT. THE BEGINNING OF WORK IN FACH EXISTING
FLOOR TO ADMINISTRATION (-12 HOUR
MINIMUM)
g.- RENOVATION WORK MAY ENTAIL INTERVENTIONS IN
AREAS OUTSIDE OF THE IMMEDIATE SCOPE OF WORK,
INCLUDING WORK, A OV O
R B E AND/OR D R BEL W THE FLOOR
o0 L R
LEVEL WITHIN THE SCOPE. IT MAY REQUIRE WORK
INVOLVING REMOTE UTILITY LINES (ELECTRICAL
MECHANICAL, PLUMBING, COMMUNICATIONS). ANY
WORK IN AREAS OUTSIDE OF THE IMMEDIATE SCOPE
OF WORK SHALL BE ALL - INCLUSIVE, PROVIDING ALL
STRUCTURES, UTILITIES, FINISHES AND EQUIP.
REQUIRED TO RESTORE THE AREA TO FULLY
OPERATIONAL CONDITIONS, TO FULLY COMPLYING
RATING INTEGRITY, AND TO MEET OWNER'S
APPROVAL ALL WORK AS DESCRIBED IN THIS NOTE
15 TO BE PART OF THE BASE CONTRACT PRICE, OR
CONTRACT CONTINGENCY ALLOWANCE FOR SUCH
WORK.
II.- CONTRACTOR SHALL VERIFY EXACT LOCATION
OF EXISTING CONCRETE RE )= G OLUMNS IN AREAS
WHERE WALLS ARE BEING REMOVED AND
INFORM ARCHITECT OF ANY CONFLICTS
BEFORE ANY WALLS ARE REMOVED 50 THAT
A/E CAN INSPECT THEM FOR CLARIFICATION
PRIOR TO PROCEEDING WITH WORK.
13.- DEMOLITION IS DENOTED 5Y BROKEN
LINES.
14.- FOR REMOVAL OF FIXTURES AND EQUIPMENT
SEE ARCHITECTURAL, PLUMBING, MECHANICAL
AND ELECTRICAL DRAWINGS.
15•- PREPARE EXISTING CONCRETE SLAB AS REQ.
BY GRINDING, LEVELING WITH ARDEX LEVELER
AS PER MANUFACTU RER S S PE C I F
I GAT IONS.
MATCH EXISTING SLAB ELEVATION AS
REQUIRED TO RECEIVE NEW SCHEDULED
FLOORING MATERIAL.
16 -- VERIFY WITH CIVIL, PLUMBING, MECHANICAL AND
ELECTRICAL DRAWINGS, ITEMS TO BE
REMOVED /RELOCATED IN CASE OF CONFLICT.
12.- PATCH AND REPAIR ALL EXISTING SURFACES
DAMAGED BY DEMOLITION AND /OR INSTAL-
I _ DESTINATION OF ALL EXISTING EQUIPMENT,
LATION OF NEW ELECTRICAL CONDUITS, GAS
PIPING, ETC PLUMPING FIXTURES, DOORS AND FRAMES, ETC.
FTC— 46 REQUIRED TO MATCH
ADJACENT SURFACES AND /OR AS REQUIRED TO BE REMOVED SHALL BE COORDINATED
WITH THE OWNER.
FOR NEW SCHEDULED FINISHES.
I&.- CONTRACTOR TO SURVEY PROJECT AREA PRIOR
TO COMMENCEMENT OF WORK. NOTE AND REPAIR
ANY DAMAGE TO AREAS WHERE WORK IS GOING TO
BE PERFORMED. NOTIFY OWNER AND ARCHITECT
WITH A LIST OF WORK PRIOR TO CONTRACT.
19-- THIS SET OF DRAWINGS 15 TO BE USED AS A UNIT
CONTRACTOR 15 RESPONSIBL E FOR DISCIPLINES
R A LLD PL S E
4 SHOULD INCLUDE EVERYTHING THAT IS NEEDED FOR
MAKING ALL SYSTEMS WORK. EXAMPLE: IF A 51NK 15
SHOWN IN THE ARCHITECTURAL PLANS, IT 15 A55UMED
THAT THE G.C. 15 PROVIDING EVERYTHING NEEDED,
A/E WILL PROVIDE THEM WITH THE UNDERSTANDING
THAT THERE WILL BE NO ADDITIONAL COST TO OWNER.
CORRIDOR v
2
118G Q I
- I=
n n {'
,4,
r'.r
CE IL.ING 0
CFI I NG
FZ] EL. S' -0..
I=34fZ�T1AL
pEMOLITION
EXISTING REINFORCED CONC.
COLUMN OR CONCRETE WALL
TO REMAIN
R
GEILINC:z
NEW TEMPORARY
PARTITION
PLAN
WALL OR PARTITION WITH
EXISTING DOOR TO REMAIN
�
3RED
11
WALL OR PARTITION WITH
EXISTING DOOR TO BE REMOVED
FLOOFP,
DEMOLITION SYMBOL
(SEE DEMOLITION LEGEND)
�Ir9
SCALE: 1/4" = 1' -0"
NOTE: ALL AS SHOWN 15 EXISTING TO REMAIN UNLESS OTHERWISE NOTES (U.ON)
M
NORTH
PARTIAL THIRD FLOOR
DEMOLITION FLAN
SCALE: 1/4' = - 1' -O'
NOTE: • ALL AS SHOWN 15 EXISTING TO REMAIN UNLESS OTHERWISE NOTES (U.ON)
REFLECTED GFzILINCx PLAN DEMOLITION NOTES
REMOVE EXISTING SOFFIT AND PREPARE TO FILL IN SPACE WITH NEW GRILL AND
CEILING TILE TO MATCH EXISTING GAS SHOWN ON REFLECTED CEILING PLAN -
SEE SHEET A -3.
RELOCATE EXISTING LIGHTING FIXTURES AS SHOWN ON REFLECTED CEILING PLAN
- SEE SHEET A -3.
O NOT USED,
NOT USED.
ALL EXISTING SUSPENDED ACOUSTICAL CEILING INCLUDING LIGHTING FIXTURES,
HVAC DIFFUSER5, FIRE SPRINKLER HEADS, SMOKE [DETECTORS, SPEAKERS, F/A
DEVICES, ETC SHALL REMAIN UNLESS OTHERWISE NOTED.
NORTH
DEMOLITION FLAN L r_;;EN::)
EXISTING REINFORCED CONC.
COLUMN OR CONCRETE WALL
TO REMAIN
EXISTING WALL OR
PARTITION TO REMAIN
NEW TEMPORARY
PARTITION
WALL OR PARTITION WITH
EXISTING DOOR TO REMAIN
--- _-- — — --
— "— —
EXISTING WALL OR
PARTITION TO BF REMOVED
11
WALL OR PARTITION WITH
EXISTING DOOR TO BE REMOVED
DEMOLITION SYMBOL
(SEE DEMOLITION LEGEND)
�Ir9
PLUMBING FIXTURES
LOCATION INDICATE EXTENT AND
DEMOLITION OF EXISTING SLAB
DENOTES EXISTING AREAS
OUTSIDE THE SCOPE OF WORK
EX16TING ELECT. OUTLET
EXISTING DATA OUTLET
E
17
EXISTING TELEPHONE OUTLET
J
EXISTING JUNCTION BOX
® ® ® ®
I HR FIRE RATED WALL
OR PARTITION
F— )EMCL, ITION NOTES:
REMOVE EXISTING FLOORING AND BASE /
PREPARE FLOORING FOR NEW FLOOR FINISH.
REMOVE EXISTING SLIDING GLASS DOOR AND
FRAME (RETURN TO OWNER).
2A NOT USED.
O EXISTING LOCKERS TO REMAIN.
O REMOVE EXISTING BASE AND WALL CABINETS
RETURN TO OWNER. EXISTING SOFFITS TO
REMAIN (TYPICALLY UNLE55 OTHERWISE
NOTED).
O REMOVE EXISTING BUILT -IN CABINET AND
RETURN TO OWNER. ALSO REMOVE SOFFIT
ABOVE.
RELOCATE EXISTING AS SHOWN IN FLOOR
PLAN (SEE SHEET A -2).
O EXISTING WINDOW SHAPES TO REMAIN -
PROTECT AT ALL TIMES DURING
CONSTRUCTION.
EXISTING 5HF -LVING TO REMAIN.
O REMOVE EXISTING WALL MOUNTED SINK AND
FAUCET - RETURN TO OWNER,
I® PROVIDE NEW DOOR OPENING 3' -0" X 1' -0' -
SEE NEW FLOOR PLAN AND DOOR SCHEDULE
FOR DETAILS. REMOVE EXIST'G OUTLETS AS
REQUIRED.
II REMOVE EXISTING COUNTER TOP - PATCH /
REPAIR WALL AS REQUIRED.
12 EXISTING WALL RECESSED FIRE EXTINGUISHER
CABINET TO REMAIN.
13 REMOVE EXISTING BASE AND WALL CABINET -
EXISTING ADJACENT LOCKERS TO REMAIN,
SHALL BE PROTECTED AT ALL TIMES DURING
CONSTRUCTION.
I� EXISTING ELECTRICAL PANEL TO REMAIN -
SEE ELECTRICAL DRAWINGS FOR DETAILS.
►8 REMOVE EXISTING PARTITION AS SHOWN AND
PROVIDE NEW DOOR OPENING WITH NEW
HEADER SET AT 7' -0" A.F.F.
Ih REMOVE EXISTING CARPETING AND METAL
THRESHOLD. PATCH FLOORING AS REQUIRED.