14-925-002LIFE &AF T*r PLAN LEGEND 2010 - F5C TABLE 601 FULLY SPRINKLERED OCCUPANCY CLASSIFICATION: GRouP e (eu5NE55) ONE HOUR FIRE RATED INTERIOR ALTERATION LEVEL 2 AREA= 3,-1(o0 5Q.FT_ OCCUPANT LOAD - 2010 - FFPC TA 3LE 7.312 OCCUPANT LOAD FACTOR: BU51NE55 USE 100 5Q-FT, GR055 / OCCUPANT m WALL OR PARTITION (SEE PARTITION TYPES) 5Q.6F /LOAD FACTOR FIRE ALARM PULL, STATION PS DOOR STRIKE 35.9 ONE HOUR FIRE /SMOKE RATED SD SMOKE DETECTOR IC INTERCOM SYST � I r� m WALL OR PARTITION (SEE PARTITION TYPES) h TWO HOUR FIRE /SMOKE RATED PROVIDED WALL OR PARTITION --- ---- 53' < 300' EGRESS WIDTH 0.2 x 41 = 9.4 36" (2) = 72" (SEE PARTITION TYPES) A HORN / STROBE LIGHT MIN, CORRIDOR WIDTH 44" 60" MIN. NUMBER OF EXIT 1 PER 500 PEOPLE 4-1 PEOPLE = 1 EXIT PARTITION TO UNDERSIDE OF ELEVATION MARKS F.. STRUCTURE FOR SECURITY REASON DRYWALL BOTH SIDES - NOT RATE EXIT LIGHT z REVISION SYMPOL ® NOTE - SHADED AREA INDICATES LIGHTED FACE. x (REFER TO COVER SHEET FOR REVISION INFORMATION) OD �= m aD EXIT LIGHT (DIRECTIONAL) NOTE : SHADED AREA INDICATES hjjN LIGHTED FACE. AREA NOT IN SCOPE OF WORK OD �v °o OFIRE EXTINGUISHER mH OFIRE ALARM SPEAKERS DC DRYCONTACT FIRE ALARM STROBE LIGHT PR CARD READER PAfP,MAL T�41Rp FL00F., LIFE GAFET�' FLAN SCALE: 3/16" = 1' -0" NORTH CLASS OF REH,45ILITATION (PER NFF'A 101, CHAPTER 43): MODIFICATION NUM5ER OF DOCTORS FOR TH15 FACILITY = 1 -2 THE OCCUF'ANC-T' OF TH15 PROJECT 15 BUSINESS / DOCTORS' OFFICES THIS PROJECT IS NOT AHCA REVIEWAPLE THIS PROJECT DOES NOT FALL UNDER ANY REGULATIONS PERTAINING, TO HOSPITAL, AMBULATORY SURGERY OR NURSING HOME. THE CLIENTS IN THIS FACILITY WILL BE "CAPABLE OF SELF PRESERVATION" AT ALL TIMES THERE WILL BE NO SEDATION AT ALL THAT WILL IMPEDE THE CAPACITY OF THE CLIENTS TO EVACUATE THEMSELVES IN CASE OF AN EMERGENCY. TH15 PROJECT WILL NOT INCLUDE OR REQUIRE ANY WET FILM PROCE551NG ALL IMAGING WILL BE DIGITAL, CODE CL.A551FICATION: CONSTRUCTION TYPE 115 2010 - F5C TABLE 601 FULLY SPRINKLERED OCCUPANCY CLASSIFICATION: GRouP e (eu5NE55) 2010 - FFPC CHAPTER 38 USE (PROFESSIONAL SERVICE) INTERIOR ALTERATION LEVEL 2 AREA= 3,-1(o0 5Q.FT_ OCCUPANT LOAD - 2010 - FFPC TA 3LE 7.312 OCCUPANT LOAD FACTOR: BU51NE55 USE 100 5Q-FT, GR055 / OCCUPANT WAITING USE 15 SQ.FT. GROSS / OCCUPANT AREA 5Q.6F /LOAD FACTOR No. OF PERSONS BUSINESS 3,5'30/100 35.9 WAITING 170 / 15 11 TOTAL 3,760 46.9 = 47 1" IEAN5 OF EGRE55 - 2010 - FFPC 39.2.6.2 h REQUIRED GROUP B PROVIDED MAXIMUM TRAVEL DISTANCE 300' (5PRNK) 53' < 300' EGRESS WIDTH 0.2 x 41 = 9.4 36" (2) = 72" PER PERSON A MIN, CORRIDOR WIDTH 44" 60" MIN. NUMBER OF EXIT 1 PER 500 PEOPLE 4-1 PEOPLE = 1 EXIT 2 EXITS All I I Na" PARKING GARAGE J1 C o o-U � I 0 V Y U �TPATI:ENT i?a R `o ARTS PROJECT AREA Mnmm/ 0 THIRD FLOOR S.W. 62ND AVENUE KEY PLAN N.TS. r O z F evis!'Ons: A FIRE DEPT. COMMENTS 07 -08 -14 A A 0 0 z� 0 V ¢ n i?a R `o z0 00 -µ x 4 W h � H x � 0 � o A w z� LL) V� a F.. o H z Wm OD �= m aD V) °° hjjN Lo 3 OD �v °o vi mH 4 11; o Ov/ T 4-+ Q ul iia, 16" 0 (d A 04 0zw 0 z h H � � � A w LL) a NEW SKEET 0-1 -08 -14 PERMIT SET 05/12/14 DRAWN: GAC CHECKED: LEN DATE: 03 -2& -14 SCALE: AS SHOWN E. �v 0.63 • 1- A, ......... Sheet No. LS -1 OF 1 I JOB # 201304 I