14-925-001South Miami Hospital n Affiliate of Baptist Health Systems of South Florid GENERAL NOTES I.- CONTRACTOR IS BEING PROVIDED WITH COMPLETE SETS OF DOCUMENTS. CONTRACTOR IS RESPONSIBLE FOR PROVIDING SUBCONTRACTORS WITH COMPLETE SETS OF DRAWINGS. INTENT IS FOR ALL SYSTEMS AND EQUIPMENT TO BE PROVIDED WITH UTILITY CONNECTIONS AS REQUIRED FOR OPERATION. EXAMPLE - IF A SINK IS SHOWN IN THE ARCHITECTURAL PLANS, THE PLUMBING PLANS DO NOT SHOW A WATER OR DRAWINGS CONNECTION THE ENGINEER WILL PROVIDE THE DESIGN DETAILS IN ACCORDANCE WITH THE DESIGN CRITERIA FOR THE REST OF THE INSTALLATIONS. CONTRACTOR IS RESPONSIBLE FOR PRO- VIDING THE CONNECTION AT NO ADDITIONAL COST TO THE OW- NER. 2.- CONTRACTOR IS RESPONSIBLE FOR VISITING THE SITE DURING THE BIDDING PERIOD AND VERIFY THAT THE CONDITIONS ARE AS DESCRIBED IN THE DOCUMENTS. DISCREPANCIES ARE TO BE NOTED IN WRITING, AND NOTIFY ARCHITECT / ENGINEERS. CONTRACTOR ACCEPTS CONDITIONS AS THEY ARE ON THE SITE, AND MUST PROVIDE SYSTEMS AND WORK AS DESCRIBED IN THE CONTRACT DOCUMENTS AT NO ADDITIONAL COST TO THE OWNER. 3.- DIMENSIONS PROVIDED ARE NOMINAL, NOT ACTUAL. THEY TAKE AS A BASIS EXISTING WALLS. IF DISCREPANCIES ARE FOUND, NOTIFY ARCHITECT IMMEDIATELY FOR COORDINATION. IF CON- TRACTOR PROCEEDS, HE DOES SO AT HIS OWN RISK AND IS RESPONSIBLE FOR ALL EXPENSES INCURRED, IF AT THE DISCRE _ TION OF THE OWNER OR THE ARCHITECT, THE WORK HAS TO BE RE -DONE. 4.- SHUTDOWN OF UTILITIES; IF A SHUTDOWN OR ANY TYPE OF INTER- FERENCE WITH EXISTING SYSTEMS IS ANTICIPATED, THE CONTRAC TOR MUST NOTIFY THE OWNER, 72 HOURS IN ADVANCEAND OBTA- IN APPROVAL IN WRITING PRIOR TO PROCEEDING. 5.- CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS AND USE ALL APPROPRIATE CONSTRUCTION METHODS / TECHNIQUES TO PROTECT EXISTING UTILITIES AND OTHER PROPERTY NOT NOTED FOR REMOVAL. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGES INCURRED DURING CONSTRUCTION AND SHALL REPAIR ANY DAMAGES AT NO EXPENSE TO THE OWNER. 6.- IF THERE IS A DISCREPANCY BETWEEN THE DRAWINGS AND THE SPECIFICATIONS, THE CONTRACTOR IS TO OBTAIN CLARIFICATION DURING THE BIDDING PERIOD. IF THE DISCREPANCY COMES UP DURING THE CONSTRUCTION, IT IS ASSUMED THE CONTRACTOR BID THE MOST EXPENSIVE WAY AND WILL DO THE WORK AS PER THE DIRECTION OF THE OWNER /ARCHITECT AT NO ADDITIONAL COST TO THE OWNER. 7.- ABBREVIATIONS THROUGHOUT THE PLANS ARE THOSE IN COM- MON USE, ARCHITECT WILL DEFINE INTENT OF ANY IN QUESTION. 8.- THE CONTRACTOR SHALL PROVIDE ALL NECESSARY TEMPORARY BARRIERS, LIGHTING, COVERINGS, FIRE PREVENTION AND OTHER EQUIPMENT TO PROTECT THE SAFETY OF ALL PERSONS AND THE PROPERTY THROUGHOUT THE ENTIRE PERIOD OF THE CONSTRUC _ TION CONTRACT. 9.- THE CONTRACTOR SHALL VERIFY SIZES AND LOCATIONS OF ALL OPENINGS FOR MECHANICAL, ELECTRICAL AND PLUMBING EQUIPMENT WITH SUBCONTRACTORS, AS WELL AS SHOP DRAWINGS AS APPROVED BY ARCHITECT, BEFORE PROCEEDING WITH THE WORK. 10.- ALL ITEMS USED IN CONSTRUCTION, BUT NOT SPECIFICALLY MENTIONED HEREIN, SHALL CONFORM TO ALL LOCAL CODES AND STATE ORDINANCES AS TO APPLICATION AND USE:. Ii.- PROVIDE ELECTRIC INSULATION BETWEEN ALL DISSIMILAR METAL AND ALSO BETWEEN CEMENT AND METAL. 12.- THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS TO COMPLETE THE PROJECT. I3.- CONTRACTOR TO REVIEW ALL EXISTING BUILDING SYSTEMS AS TO THEIR COMPLIANCE WITH ALL LOCAL AGENCY REQUIREMENTS AND BRING ANY NON - CONFORMING ITEMS TO ARCHITECT'S AND ENGINEER'S ATTENTION, 14.- GENERAL CONTRACTOR IS TO PROTECT EXISTING ADJACENT AREAS TO WHERE WORK IS TO BE PERFORMED. ANY EXISTING MILLWORK, EQUIPMENT DAMAGED DUE TO WORK PERFORMED SHALL BE REPAIRED/ REPLACED TO MATCH EXISTING (TYPICAL UNLESS OTHERWISE NOTED). 15.- DRAWINGS ARE SCHEMATIC SHOWING RELATIVE LOCATIONS AND CONNECTIONS AND SHALL NOT BE SCALED AT ANY TIME. 16.- ALL WOOD BLOCKING WITHIN BUILDING STRUCTURE, SHALL BE FIRE - RETARDANT TREATED AS PER SPECIFICATIONS. 17.- GENERAL CONTRACTOR SHALL INSPECT ALL EXISTING RATED WALLS / PARTITIONS WITHIN SCOPE OF WORK AREA, CONTRACTOR SHALL UPGRADE EXISTING PARTITIONS AS REQUIRED TO MAINTAIN THE INTEGRITY OF THE DESIGNATED RATING. 18.- ELEVATION AND LEVELS; A. ALL NUMERICAL ELEVATIONS ARE TO TOP OF CONCRETE SLAB. UNLESS NOTED OTHERWISE. 19 ALL INTERIOR GYPSUM WALL BOARD IS 5/8' TYPE X G.W.B. ON METAL STUDS OR FURRING CHANNELS UNLESS NOTED OTHERWISE, SIZES AS DIMENSIONED ON FLOOR PLANS. SEE NOTES 9 FOR LOCATION OF WATER RESISTANT G.W.B. 20.- PROVIDE WATER RESISTANT TYPE X G.W.B. IN ALL TOILETS, AND JANITOR'S CLOSETS, 21.- BEFORE PATCHING ANY FIRE - RATED C.M.U. PARTITION, FILL ANY EXPOSED CELLS SOLID WITH GROUT. 22.- PROVIDE FINISH WALL UNDER AND BEHIND ALL EQUIPMENT AND CASEWORK. 23.- LOCATION AND SIZE OF CEILING AND WALL ACCESS PANELS SHALL BE DETERMINED BY THE POSITION OF VALVES AND OTHER MECHANICAL AND ELECTRICAL ITEMS WHICH REQUIRE ACCESS. THE CONTRACTOR SHALL COORDINATE WITH ALL TRADES. THE ARCHITECT SHALL REVIEW AND APPROVE ALL FINAL LOCATIONS OF ACCESS PANELS PRIOR TO INSTALLATION. 24.- THERE SHALL BE NO BACK - TO BACK ELECTRICAL TELEPHONE OR OTHER OUTLETS. 25.- ALL VERTICAL PIPING AND COLUMNS, EXPOSED IN ROOMS SHALL BE FURRED WITH METAL STUDS AND DRY WALL AND FINISHED TO MATCH ADJACENT WALLS, UNLESS NOTED OTHERWISE, EXCEPTIONS: A. ELECTRIC CLOSETS C. MECHANICAL ROOMS B. TELEPHONE CLOSETS D. STAIRS 26.- WHERE HVAC OR OTHER MECHANICAL, ELECTRICAL AND PLUMBING ITEMS PENETRATE PARTITIONS, STUDS SHALL BE BRACED AND FRAMED TO STRUCTURE AS REQUIRED TO PROVIDE ADEQUATE SUPPORTS. ALL PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED TO PROVIDE FIRE, SMOKE AND / OR ACOUSTICAL ISOLATION OF SPACES WITH APPROPRIATE FIRE S.T.0 MATERIAL. 27.- SEE INTERIOR ELEVATIONS FOR FINISHES AND FINISH DETAILS FOR INTERIOR SPACES. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR ACOUSTICAL TILE FINISH. 28.- SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATION OF CEILING MOUNTED MECHANICAL, ELECTRICAL FIXTURES. 29.- STAGGER JOINTS VERTICALLY AND HORIZONTALLY IN ALL G.W.B. PARTITIONS EA. SIDE OF PARTITION, JOINTS STAGGERED MINIMUM 2' -0 ", UNLESS OTHERWISE NOTED. 30. CONTRACTOR SHALL CONFIRM THAT ALL EXISTING EXPOSED STEEL COMPLIES WITH N.F,P.A FIRE PROTECTION REQUIRE- MENTS. CONTRACTOR SHALL PROVIDE ALL NECESSARY INSULA- TION /FIRE PROTECTIVE COATINGS. 31. CONTRACTOR TO SUBMIT ALL SHOP DRAWINGS TO ARCHITECT AND THE BUILDING DEPARTMENT FOR APPROVAL. (ELEVATOR, TRUSSES, WINDOWS, ETC.) 32, CONTRACTOR REQUIRED TO PULL SEPARATE DEMOLITION PERMIT. SMH BREAST CEN R XPANSION SOUTH MIAMI HOSPITAL , MEDICAL ARTS BUILDING 6200 S.W. 72 STREET TEL: (786) 596 -8386 EB0000924 LOUIS J. AGUIRRE & ASSOCIATES P.A. CONSULTING ENGINEERS 9150 SOUTH DADELAND BLVD. SUITE 900 MIAMI, FLORIDA 33156 TELEPHONE: (305) 670 -0141 FAX: (305) 670 -0144 E -MAIL ADDRESS: GRALMAIL@LLJAAPA.COM SOUTH MIAMI, FLORIDA 33143 Fax: (786) 596 -2901 0 d 0 0 r c h i t e c t s FLORIDA LICENSE *AA0002689 2100 PONCE DE LEON BLVD. SMITE 1170, CORAL GABLES, FL 33134 Td (305)265 -7177 Fax: (305)262 -8435 LUIS E. NAPA, A.LA Fl. AR0008063 PROJECT NUMBER: 201304 (INTERIOR ALTERATION) MARCH 28, 2014 INDEX ARCHITECTURAL OF DRAWINGS A -0 COVER AND GENERAL INFORMATION. A -1 PARTIAL THIRD FLOOR DEMOLITION PLAN, LEGEND AND NOTES. A -2 PARTIAL THIRD FLOOR PLAN AND EQUIPMENT PLAN, LEGEND AND NOTES. A -3 PARTIAL THIRD FLOOR REFLECTED CEILING PLAN, LEGEND AND NOTES. A -3A INTERIOR ELEVATIONS. A -4 PARTITION TYPES, DOOR AND FINISH SCHEDULES, NOTES AND DETAILS. A -5 CABINET AND MISCELLANEOUS DETAILS. A -6 PENETRATION AND FIRE RATED DETAILS. A -7 PENETRATION AND FIRE RATED DETAILS. A -8 PENETRATION AND FIRE RATED DETAILS. MECHANICAL MO.00 SYMBOLS LEGEND AND GENERAL NOTES. M3.00 THIRD FLOOR DEMOLITION PLAN. M3.01 THIRD FLOOR PLAN. M6.00 SCHEDULES. M7.00 DETAILS. PLUMBING PO.00 SYMBOL LEGEND AND GENERAL NOTES. P3.00 THIRD FLOOR PLAN, SANITARY WASTE. P3.01 THIRD FLOOR PLAN, DOMESTIC WATER. BUILDING INFORMATION ORIGINAL BUILDING DESCRIPTION BUILDING JURISDICTION: SOUTH MIAMI, MIAMI DADE COUNTY PRIMARY USE CLASS BUSINESS NUMBER OF STORIES : 6 (EXISTING BUILDING) NEW PROJECT DESCRIPTION PROJECT AREA: THIRD FLOOR: 3,760 S.F. SPRINKLED: FULLY SPRINKLERED APPLICABLE CODES FLORIDA BUILDING CODE 2010 EDITION. FLORIDA FIRE PREVENTION CODE 2010 EDITION. NFPA 101 LIFE SAFETY CODE, 2009 EDITION. FIRE, PROTECTION FPO.00 SYMBOL, LEGEND AND GENERAL NOTES. FP3.01 THIRD FLOOR PLAN FIRE PROTECTION. FP7.00 DETAILS FIRE PROTECTION. ELECTRICAL EO.00 SYMBOL LEGEND AND GENERAL E3,00 DEMOLITION THIRD FLOOR PLAN E3.01 DEMOLITION THIRD FLOOR PLAN E3.02 NEW WORK THIRD FLOOR PLAN E3.03 NEW WORK THIRD FLOOR PLAN E6.00 PANELBOARD SCHEDULES. NOTES. - LIGHTING. - POWER & SYSTEMS. - LIGHTING. - POWER & SYSTEMS. REVISIONS Pull'm 01 0-1 ML AlWHITEGTURAL AMIREVI,4TION& WOFKWx L)WONWN 4 AND L ANGLE AT C CENTERING O DIAMETER " POUND OR NUMBER A LAVATORY A/C AIR CONDITIONING ACI AMERICAN CONCRETE INSTITUTE ACP A6bE5TOS CEMENT PIPE ACSC ASPHALTIC CONCRETE :SURFACE COURSE ACU AIR CONDITIONING UNIT ACT ACOUSTICAL CEILING TILE AD AREA DRAIN ADJ ADJUSTABLE A/E ARCHITECT/ENGINEER AF ACCESS FLOORING AFF ABOVE FINISHED FLOOR AGGR AGGREGATE AHU AIR HANDLING UNIT ALT ALTERNATE AL ALUMINUM ANN ANNUNCIATOR ANSI AMERICAN NATIONAL STANDARDS INSTITUTE ANT ANTENNA AP ACCE55 PANEL APL ACCE55 PLENUM APROX APPROXIMATE ARCH ARCHITECTURAL A55 ASBESTOS ASPH ASPHALT A5TM AMERICAN 50CIETY OF TESTING 4 MATERIALS 15 NAME PLATE RAT BATTERY BD BOARD BITUM BITUMINOUS BLDG BUILDING BLKG BLOCKING BM BEAM BOT BOTTOM C OPPOSITE GAB CABINET CB CATCH BASIN GEM CEMENT CER CERAMIC CFM CUBIC FEET PER MINUTE CCs COMER GUARD CHP CRICKET HIGH POINT CI CAST IRON GIG CAST IRON COVER GIP CAST IRON PIPE CJ CONTROL JOINT CLG CEILING CLGD CELNG DIFFUSER CLKG CAULKING CLO CLOSET CLP CRICKET LOW POINT CLR CLOSER CMP CORRUGATED METAL PIPE CMU CONCRETE MASONRY UNIT CNTR COUNTER CO CLEAN OUT COL COLUMN COMM COMMUNICATION CONC CONCRETE CONN CONNECTION CONSTS CON87RUCTICN CONT CONTINUOUS CPT CARPET TILE CT CERAMIC TILE GTR CENTER CT5K COUNTERSUNK 5 STUCCO DBL DOUBLE DEG DEGREE DEPT DEPARTMENT DE51G DESIGNATION DET DETAIL DF DRINKING FOUNTAIN DG DOOR GRILLE DIA DIAMETER DAG DIAGRAM DIM DIMENSION DSR DISPENSER DN DOWN DO DOOR OPENING DSP DRY STANDPIPE D5 DOWN SPOUT P1166 DRAWINGS DWR DRAWER E SPEAKERS EA EACH EC EPDXY COATING EHD ELECTRIC HAND DRYER EL ELEVATION EJ EXPANSION JOINT ELEC ELECTRICAL ELEV ELEVATOR EMER EMERGENCY ENCL ENCLOSURE ENGR ENGINEER EPNL ELECTRICAL PANEL FQ EQUAL EQPT EQUIPMENT EST ESTIMATE ET EXPAN5ION TANK EWC ELECTRIC WATER COOLER EXH EXHAUST EXBT EXISTING FXT EXTERIOR THK THICK FA FIRFE ALARM FABL FIRE ALARM BELL FD FLOOR DRAIN FG FIBERGLASS FCO FLOOR CLEANOUT FD FIRE DAMPER FDC FIRE DEPARTMENT CONNECTOR FDR FIRE DOOR FDN FOUNDATIONS FDV FIRE DEPARTMENT VALVE FEC FIRE EXTINGUISHER CABINET FEX FIRE EXTINGUISHER FF FINISH FLOOR FH FIRE HYDRANT FIN FIN15H FL FLOOR FM FACTORY MANUAL FLASH FLASHING FLG FLANGE FLOUR FLUORESCENT FOC FACE OF CONCRETE FOF FACE OF FINISH FOM FACE OF MASONRY F05 FACE OF STUD FPRF FIREPROOF FPM FEET PER MINUTE FRD FRENCH DRAIN F5 FULL SIZE FT FOOT OR FEET FTG FOOTING FT -LB FOOT POUNDS FURR FURRING FUT FUTURE a WOOD GA GAUGE GAL GALLON GALV GALVANIZED GB GRADE BEAM GEN GENERATOR GL GLASS GND GROUND GI-5 GLASS BLOCK GR GRILLE GRID GRADE GWB GYPSUM WALL BOARD GYP GYPSUM H HB HOSE BIB HC HANDICAPPED HDWD HARDWOOD HDWE HARDWARE HGT HEIGHT HM HOLLOW METAL HORIZ HORIZONTAL HP HIGH POINT HR HOUR HTR HEATER HVAC HEATING, VENTILATION, AND AIR CONDITIONING HYD HYDRANT I ID INSIDE DIAMETER ( DIAN ) N INCHES INT INTERIOR J JAN JANITOR JB JUNCTION BOX JCT JUNCTION J5K JANITORS SINK JT JOINT K► KO KNOCK OUT IL LENGTH LAM LAMINATE LAV LAVATORY LB5 POUNDS LBS /HR POUNDS PER HOUR LP LINEAR DIFFUSER LP LOW POINT LT LIGHT PSI MATL MATERIAL MAX MAXIMUM MC MEDICINE CABINET MECH MECHANICAL MEMB MEMBRANE MFR MANUFACTURER MIN MINIMUM M 5 MBCELANECUS MO MASONRY OPENING MTD MOUNTED MTL METAL MUL MULLION MULT MULTIPLE N N NORTH NEC NATIONAL ELECTRIC CODE NIC NOT IN CONTRACT NO NUMBER ROM NOMINAL NFL NAME PLATE NT5 NOT TO SCALE O OA OVERALL 058 OBSCURE OC ON CENTER OD OUTSIDE DIAMETER DIM) OFS OVERFLOW SCUPPER OPP OPPOSITE 10 PC PRECAST CONCRETE Pi PIPE JOINT PL PLASTIC P LAM PLASTIC LAMINATE PLAS PLASTER PLYWD PLYWOOD PNT PAINT PT POINT OR PATIENT PTD PAPER TOWEL DISPENCER PTN PARTITION PTR PAPER TOWEL RECEPTACLE 42 QRT QUARTER QT QUARRY TILE R R REAR RA RETURN AIR RAP RADIUS RB REINFORCED BEAM RCPT RECEPTION RD ROOF DRAIN REF REFERENCE REINF REINFORCED REQ REQUIRED RE5L RESILIENT R9TR REGISTER RM ROOM RO ROUGH OPENING RWL RAIN WATER LEADER a 5 STUCCO SC SCREED CONCRETE SCHED SCHEDULE 5EC SECOND BD SMOKE DETECTOR SECT SECTION SF SUPPLY FAN SG SPANDREL GLASS 5GR SYNTHETIC GRADE SHR SHOWER SHT SHEET SIG SIGNAL SIM 61MILAR SI4 SINK SM SHEET METAL SMK SMOKE SND BOUND SPEC SPECIFICATION SPKR SPEAKERS SQ SQUARE SQFT SQUARE FEET 55T STAINLESS STEEL 5T STREET 5TC SOUND TRANSMISSION COEFFICIENT STD STANDARD ST -D STORM DRAIN BTL STEEL STRL STRUCTURAL 5USP SUSPENDED SYM SYMMETRICAL SYS SYSTEM T T TOILET TB TIE BEAM TC TIE COLUMN TEL TELEPHONE TEMP TEMPERATURE T4G TONGUE AND GROVE THK THICK TOC TOP OF CURB TOPP TOP OF PARAPET T05 TOP OF BLAB TP TOP OF PAVEMENT TRD TREAD T5 TUBULAR STEEL TSTAT THERMOSTAT TV TELEVISION TW TOP OF WALL TYP TYPICAL U US UNDERCUT UL UNDERWRITER'S LABORATORIES UNF UNFINISHED UON UNLESS OTHERWISE NOTED U05 UNLESS OTHER SPECIFIED UR URINAL UTIL UTILITY Y VB VINYL BASE VCT VINYL COMPOSITION TILE VERT VERTICAL VEST VESTIBULE VF VERIFY IN FIELD VOL VOLUME VT VAPOR TIGHT VTR VENT THRU ROOF w WR WIRE W WINDOW W/ WITH WC WATER CLOSET WCO WALL CLEANOUT WD WOOD WF WALL FABRIC W/o WITHOUT WP WATER PROOF WSCT WAINSCOT WT WEIGHT WWF WWM WELDED WIRE FABRIC WELDED WIRE MESH PERMIT SET 05/12/14