Loading...
14-815-010PRODUCT INFORMATION FEATURES: • UL LISTED • CALIFORNIA STATE FIRE MARSHAL LISTING NUMBERS: 2088 -9608 DOOR HOLDERS 3550 - 0026:232 • MOUNTING: WAU, SEMI -FLUSH • FINISH: DOUBLE PLATED CHROME SPECIFICATIONS: • VOLTAGE RANGE: OPERATES WITH 24 VDC, 24 VAC, OR 120 VAC • CURRENT: 15 mA DESCRIPTION: 2088 -9607 MAGNETIC DOOR HOLDERS HAVE A MINIMUM HOLDING FORCE OF 25 LBS. UNDER NORMAL CONDITIONS, THE ELECTROMAGNET IS ENERGIZED TO HOLD OPEN THE DOOR. IN THE EVENT OF A FIRE, THE SIMPLEX FIRE ALARM CONTROL PANEL, OR AN APPROVED PERIPHERAL APPLIANCE, WILL AUTOMATICALLY INTERRUPT THE VOLTAGE TO THE DOOR HOLDER RELEASING THE DOOR TO PREVENT THE SPREAD OF SMOKE. DOORS MAY BE MANUALLY OPENED WHEN THE DOOR HOLDER IS ENERGIZED. WIRING: • ALL WIRING TO COMPLY WITH LOCAL CODE. • MAINTAIN CORRECT POLARITY • CONDUCTORS MUST TEST FREE OF ALL GROUNDS. TO LOCATE AND MOUNT OUTLET BOX CENTER LINE OUTLET BOX DOOR I-,Y WALL UN DOOR JAMB X 2088 -9608 MAGNETIC DOOR HOLDER OPTIONAL MOUNTING ARMATURE ASSEMBLY q� THRU -BOLT MOUNTING TOP OF D00 2 5 8' BACT KRf��!}SE 1 3/4' DOOR PULL 2--1 _f OF DOOR MOU K �Lww SIICIPLEX N0. 2 I 5- HOLES 2088 -9680) O "NOT SWIVEL T��HgR�EATDEHD�POD S BALL SWIVEL TRANSFER POINT- 13 PULL SIDE OF DOOR MOUNTING ARMATURE ASSEMBLY TOP OF DOOR 2 5 ARMATURE BASE 2 110 X 1 -1/2 MOUNTING CK VIEW SCREWS HOLES 5' c /O THREADED ROD EXTENSIONS INSERT HERE TRANSFER P0�- + MAI I CWn I MOUNTING ARMATURE INSTRUCTIONS 1. WITH DOOR MAGNET SECURELY FASTENED, ALIGNED AND ENERGIZED, PROCEED WITH SWIVEL BASE ASSEMBLY. 2. ATTACH SWIVEL PORTION OF MAGNET, BEING CAREFUL TO CENTER CATCH PLATE OVER MAGNET. 3. WITH CATCH PLATE ASSEMBLY ATTACHED MAGNETICALLY TO DOOR MAGNET PEEL ADHESIVE BACKING OFF MOUNTING TEMPLATE AND SLIDE OVER CATCH PLATE, MAKING SURE ADHESIVE SIDE LACES DOOR. 4. GENTLY CLOSE DOOR AND WITH ONE HAND ADJUST BASE OF CATCH PLATE TO LIE FLIT AGAINST DOOR. 5. WHILE KEEPING SLIGHT PRESSURE ON DOOR, SLIDE MOUNTING TEMPLATE OVER CATCH PLATE TO DOOR SURFACE AND APPLY PRESSURE TO TEMPLATE IN A FEW SPOTS. 6. OPENING DOOR WILL REVEAL MOUNTING TEMPLATE. APPLY FINAL PRESSURE TO INSURE TEMPLATE DOES NOT FALL OFF WHILE ASSEMBLY TAKES PLACE. 7. INSERT ALIGNMENT TEMPLATE INTO CENTER OF MOUNTING TEMPLATE. USE TAB TO ROTATE FOR FINE ADJUSTMENT. WHILE HOLDING ALIGNMENT TEMPLATE WITH ONE WAND, REMOVE ADHESIVE BACKING OF TAB, THEN PUSH FLAT AGAINIST 8. IFUSING OPTIONAL DOOR BACK PLATE, CENTER PUNCH POINTS INDICATED ON ALIGNMENT TEMPLATE FOR EITHER HORIZONTAL OR VERTICAL MOUNTING. FOR BEST RESULTS DRILL 1/8' PILOT HOLE FIRST, THEN FOLLOW WITH 5/16' DI. DRILL, DRILL STRAIGHT THROUGH DOOR. 9. IF MOUNTING CATCH PLATE ASSEMBLY DIRECTLY TO DOOR, DRILL 1/8' DIA PILOT HOLE APPROXIMATELY 1 TO 1 1 /:L' DEEP, BEING CAREFUL NOT TO GO THROUGH DOOR. 10. ALIGN HOLES, EN INSERT FSCREWS ANDDOOR/DIRECT) ASSEMBLY FULLY. LASTLY, REMOVE MOUNTING TTEMPIATE.. SWIVEL INI CENTER 1. REFER TOO DRAWING & CHART TO LOCATE OUTLET BOX. 2. LINE 7p 5` FROMOMO OT THE HORIZONTAL CENTER FROM FACP OR HS DOOR OLDER + \\ I \MVMW1W - =SVQl 00-2003 W MWMS\WM WkW HOSMAL (MCTM - TEASMH 2ND nDOR DODR HMM 276164201\S►H=Vlca MtDE2uff6u42m.M DATE PLOTTED: June 16. 2014 DATE SAVED: Jun. 16, 2014 x O O COMMON LOW HIGH LO m e m I U SINGLE GANG BOX MINIMUM 2 1/2' DEEP - SUPPUED BY CONTRACTOR N -� TO NEXT HOLDER W IfiffsaloAlsYl.' DESCRIPTION: THE MR -800 CONTROL RELAYS OFFERS SPOT 10 AMP CONTACT WHICH MAY BE OPERATED BY ONE OF THREE INPUT VOLTAGES. A SINGLE RELAY MAY BE ENERGIZED FROM A VOLTAGE SOURCE OF 18 -35 VDC OR VAC, OR 115VAC BY WIRING TO APPROPRIATE INPUT TERMINALS. EACH RELAY CONTAINS A RED LED WHICH INDICATES THE RELAY COIL IS ENERGIZED. THESE DEVICES ARE IDEAL. FOR APPLICATIONS WHERE LOCAL CONTACTS ARE REQUIRED FOR SYSTEM STATUS, REMOTE CONTACTS FOR CONTROL OF ELECTRICAL LOADS AND GENERAL PURPOSE SWITCHING. WIRING: 1. ALL WIRING TO COMPLY WITH LOCAL CODE. 2. MAINTAIN CORRECT POLARITY 3. CONDUCTORS MUST TEST FREE OF ALL GROUNDS. PRODUCT SPECIFICATIONS: AIR PRODUCTS MR -801 SPDT CONTROL RELAY (SIMPLEX 2088 -9032) METAL ENCLOSURE SUPPLIED WITH RELAY ING HOLES TO SECURE TO WALL SPDT CONTACTS 10 AMPS 0 115 VAC POWER REQUIREMENTS: 24VDC 0 22mA, 24VAC 0 6OMc, OR 120VAC 0 26Mo PER MODULE POSITION "I I I" POLARIZED COIL INPUT(S): DC INPUTS ONLY N C 0' ENERGIZED INDICATOR: ONE RED LED PER MODULE POSITION lieliellel CONTACT RATINGS: RESISTIVE LOAD: 10A 0 120VAC. 7A 0 3OVDC /277VAC RELAY ENERGIZED LED INDUCTIVE LOAD: 25HP / .33HP 0 120VAC / 150VAC CONTACT CONSTRUCTION: DRY FORM 'C' SPDT PER MODULE POSITION AMBIET TEMPERATURE 32F TO 120E (OC TO 491C) 0 85% RH (032C) NON - CONDENSING / NON- FREEZING WIRING: SOLID OR STRANDED: 112 TO +22 AWG TERMINALS '/T' VERSION: 3.5' WIDE, LOW PROFILE SNAP TRACK PROVIDED WITH MOUNTING SCREWS /S' VERSION: ALUMINUM SPACERS PROVIDED WITH 18 X 7/8' SELF TAPPING SHEET METAL SGREWS 0 ' /C' VERSION: COVER MATERIAL: MR -801, MR -802: PLASTIC ABS 94V -0 (' /C' GREY, ' /C /R' RED) O 0 24 120 MR -B04, MR -808: CRS 18 GA (%C' GREY, 'C /R' RED) 24VDC 0 22mo - + APPROVALS: ' /S' MS '/T' VERSINS: UL RECOGNIZED COMPONENT (UL964, UOXX2), FILE jS3403 12VAC 0 60mo AC AC /C' AND 'C /R' VERSIONS: UL LISTED (UL864, UOXX), FILE IS3403 120VAC 0 26mo N Z H 'C/' AND 'C /R' VERSIONS: CSFM LISTED, 7300 - 1004:110 INPUT CONTROL 'C /R' VERSIONS: MEA ACCEPTED, 73 -92 -E VOL 29 VOLTAGE TRACK MOUNTING MOUNTING TRACK SCREW WIAA/1"DADE CO. ME DE PsAR vic.4f :i .� e u -W t• , �r r ` -� _- Yom. • +} `�n •,.. - \ •L. ,r^ V/ cc V! Z Q -/ w DO LL Q Q W C-4 Z N L9 i, N � N (p O Clr M M c`no LU J (9 Q °p° 2 ul 7-.L M CLo� M m v < ° o CO C n�Z .. o�a� w d a cn 4.+ i U Z Q En m -0 1 -1 W W > w _ O Z E W C7 U) 1` (L2 20 y Q N< � J 0¢ U Z O LL Z O N U w 0 Z O N Z O W U O 0 w U) m U U v M 0 �c O Z ►�-1 w w Uj U i Q 14 Q z W w Ly Y lL � _ w F, LL cli O -il w o OZ z it 0 ~ Q F W m z a o U) Q J W O U z ~ z O U W U U w W Ww rr < a LL WO = -, W ti U O O a w Ha U d d i Q W 0 Q1 Ho O= F- H P4 9 S z S OU W N _ a r1 co FO W 0 O -♦, �� •�(� Z 0 ZW U) z i„L�i U V) cn � J FTi %4 FLI O v c U` O Z w Z O 0 Z0 �U) � a O w O z N a cc w E� U+� C7;�g Z 0 Oa g O O �°w O ZO az 0 O n°"4 �2 mica �a Q 0¢¢ �0 DRAWN BY: DATE: DESIGNED BY: DATE: APPROVED BY: DATE: PROJECT NUMBER: ;$ 978164201 SH TITLE/ PATH: i SHEET NUMBER: TYPICAL SIZE D (24•XM1