Loading...
14-62-014I _ { DEMOLITION NOTES: -- 1O. REFER TO TOMOTHERAPY EQUIPMENT INSTALLATION DOCUMENTS PROVIDED <D BY ACCURAY INCORPORATED FOR EXACT REQUIREMENTS AND LOCATION OF DEVICES. O EXISTING TOMOTHERAPY EQUIPMENT ELECTRICAL SERVICE TO BE MODIFIED RAD/ ONC Ell 0 11 1 RAID ONC. AND REUSED AS INDICATED ON PLANS. MARIA MED. DIR. ALLIE PHYS O APOLLO LASER RECEPTACLE OUTLET TO REPLACE EXISTING. REUSE AMELIA STEVEN GARCIA ASSIST/ EXISTING DEDICATED CIRCUIT FROM CURRENT INSTALLATION. CIRCUIT 11-20 -7. RODRIGUES OLSZEWSKI STAFF SERRA WORK SEE ACCURAY INC. DOCUMENTS. TOILETS O EXISTING EMERGENCY OFF BUTTON SWITCH "EO" LOCATED IN CONTROL r AREA STATION TO BE REMOVED AND REPLACED BY A NEW "EO" SWITCH AND COVER PLATE TO MATCH AVAILABLE JUNCTION BOX. REUSE EXISTING JUNCTION BOX. —E�O5 PROVIDE A NEW 480V, 3 POLE, 70A SHUNT TRIP BREAKER IN NEMA I rl ENCLOSURE TO REPLACE EXISTING 3P, 100A BREAKER LOCATED IN TOMOTHERAPY EQUIPMENT CONTROL AREA TO SERVE NEW EQUIPMENT PDU. O EXISTING 12" WIDE X 4" DEEP ELECTRICAL TROUGH WITH THREE SEPARATE DIVIDED COMPARTMENTS FROM GANTRY TO JB1 TO BE REUSED BY NEW INSTALLATION. POWER AND MISCELLANEOUS LOW VOLTAGE SYSTEMS ` CABLING SHALL RUN IN DEDICATED COMPARTMENTS PER NEC. CORRIDOR O POWER DISTRIBUTION UNIT (PDU), POWER CONDITIONER AND DATA SERVER UNIT TO BE PROVIDED BY ACCURAY, SEE INSTALLATION DOCUMENTS FOR RELEVANT INFORMATION. O8 EXISTING DOOR SWITCH, RADIATION WARNING LIGHTS, LIGHT SWITCHES, ' JUNCTION BOXES, CONDUITS AND FLOOR TROUGHS ASSOCIATED WITH ' ; CURRENT TOMOTHERAPY EQUIPMENT TO BE REMOVED SHALL BE REUSED AS r o PART OF NEW UNIT INSTALLATION. PROVIDE NEW DEVICES, COVER PLATES ' ' SEE ENLARGED ,` le,� AND WIRING AS NECESSARY. PLAN ON SHEET SOIL O9 NEW POWER DISTRIBUTION UNIT "PDU" TO REPLACE EXISTING AT THIS SAME , E5.00 UTILITY MED LOCATION. ' ROOM 10. EXISTING JUNCTION BOX #1 TO REMAIN (IN FRONT OF "PDU" TO REMAIN OPEN FOR WIRING CONNECTIONS. o 11. EXISTING JUNCTION BOX JB2 LOCATED IN FLOOR BELOW PATIENT TABLE WITH EXAM EXAM EXAM EXAM POWER / SIGNAL COMPARTMENT BARRIER. ' "- ' "- "' "'�'� DARK 12. EXISTING JUNCTION BOX JB3 LOCATED IN CEILING SPACE. CONTRACTOR TO ' MECHANICAL ROOM VERIFY LOCATION AT FIELD AND REUSE. ' ELECT. STOR. 13. EXISTING DORADO LASER LOCATIONS TO REMAIN. a 1 14. EXISTING APOLLO LASER LOCATIONS TO REMAIN. 15. EXISTING CONVENIENCE TYPE RECEPTACLES IN TOMOTHERAPY AREA TO Kz REMAIN. CONTRACTOR TO PROVIDE NEW DEVICES AND FACEPLATES TO MATCH EXISTING. CIRCUITS TO BE ENGRAVED IN FACEPLATES. 16 EXISTING 4" PHYSICS CONDUIT JUNCTION BOX IN CONTROL ROOM AREA TO REMAIN. CORRIDOR 17. EXISTING CCTV CAMERAS TO REMAIN. 14 15 15 ILE7, -I I I r 16 - - - - - -- - GFI _ LJ O I1-20-9 i 10 ' EXISTING 4' PHYSICS ILE7; II 1 6 a;;; 1 CONDUIT TO REMAIN i , 15 , !III , - - - - -- ,- 13 ------ - - - - -- .Iiiii ----- '----- � - LCJ I I .I _ 1 ` 15 I'll ILE7 -9 t ey , (TYP.) ILE7 -9 DS 1 13 (TYP.) V�i��ABOVE ---- - - - - -- --- i- - - - - -- ABOVE ,)QiV ,�.J,' BELOW ; BELOW \Jill ire 1 DEMOLITION FLOOR PLAN - ELECTRICAL E3.00 SCALE: 1/4 " =1' -0" iv; ,Tn IL20 -II (TYP.) ILE7 -9 (i IL20 -11 �_ NUR STATIC r - - - - r00NTFcOLL SIMULATC)d ARCHITECT: BERMELLO AJAMIL & PARTNERS, INC. Architecture Engineering Planning - InteriorDesign Landscape Architecture 261_ Sz)uth Bayshore Drive 10th Floor Miami, Florida 33133 (305) 859 -2050 Fax (305) 860 -3700 LOUIS J. AGUIRRE & ASSOCIATES, P.A. Consulting Engineers 9150 South Dadeland Blvd. • Suite 900 Miami • Florida 33156 • EB0000924 Telephone 305.670.0141 Facsimile 305.670.0144 www.liaal2a.com Project No.: 23075 Rw • S � L I$;cl•z2 '•QR.E. L NH`' 116.42 CONSTRUCTION DOCUMENTS REVISIONS: PROJECT NAME: SMH -Tomo Equipment Replace PROJECT ADDRESS: 7400 S.W. 62nd Ave. South Miami, Florida 33143 KEY PLAN COMM. NO. 40073.000 SCALE: AS SHOWN DATE: 11-14-2013 DRAWN: AP CHECKED: AG CADD FILE: MINSTITUTIONAL DRAWING TITLE: DEMOLITION FLOOR PLAN ELECTRICAL SHEET NO. E3.00