14-523-030Project 4:413508.000 , - - - - • - - - r Y•Y Y • 2121 Ponce de Leon -Moule�a & Suite 35 0 u i Y Gas Coral Galbles, FL 33134 ■ phone: 305.569.1692 PHASING UPGRADE ELECTRICAL GENERAL NOTES. � lGmurdni ftnem fax: 305.5G�.16�3 •0 0 `• r LIGHTING SYSTEM Austin - Dallas - Denver . Houston . Kansas City . rAiami• Al THE DRAWINGS ARE GENERALLY DIAGRAMMATIC AND IT IS THE INTENT AND MEANING OF THE CONTRACT DOCUMENTS THAT THE CONTRACTOR SHALL PROVIDE Nashville - Phoenix . R0 07659 . Washington J`.C.". SEQUENCE G, REFER TO ARCHITECTURAL DRAWINGS AND SPEgFICATIDNS FOR LOCATION OF ALL CEILING ELEMENTS (LIGHTS, SPRINKLERS, DIFFUSERS, ETC). ALL CEILING Eie0000�cs: AN ELECTRICAL INSTALLATION THAT IS COMPLETE WITH ALL ITEMS AND APPURTENANCES NECESSARY, REASONABLE INCIDENTAL, OR CUSTOMARILY INCLUDED, MOUNTED ITEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE ARCHITECTURAL DIMENSIONED DRAWINGS. IF LOCATION FOR AN ITEM IS NOT SHOWN ON THE EVEN THOUGH EACH AND EVERY ITEM IS NOT SPECIFICALLY CALLED OUT OR SHOWN. THE CONTRACTOR SHALL PROVIDE ALL EQUIPMENT, MATERIALS, LABOR, ARCHITECTURAL DRAWINGS, VERIFY THE EXACT LOCATION OF THE ITEM WITH THE ARCHITECT PRIOR TO INSTALLATION. THESE REQUIREMENTS APPLY TO ALL CRITICAL PHASING SYSTEM UPGRADE SEQUENCE OF INSTALLATION SUPERVISION AND SERVICE NECESSARY SO AS TO PROVIDE A COMPLETE, FUNCTIONING ELECTRICAL SYSTEM IN SAFE WORKING ORDER. CEILING TYPES IN ALL AREAS. DO NOT SCALE OR DIMENSION LOCATIONS FROM THESE DRAWINGS.Y • Yom•• THE GOAL FOR THE INSTALLATION OF THE EQUIPMENT ASSOCIATED WITH A2 SYMBOLS FOR VARIOUS ELEMENTS AND SYSTEMS ARE SHOWN ON THE DRAWINGS. SHOULD THERE BE ANY DOUBT REGARDING THE MEANING OR INTENT OF G2 XXX THE DATACENTER UPGRADE IS TO INSTALL AND MAKE READY AS MUCH OF CAPACITOR THE SYMBOLS USED, AN INTERPRETATION SHALL BE OBTAINED FROM THE ARCHITECT IN WRITING. THE DECISION OF THE ARCHITECT SHALL BE FINAL AMMETER (ANALOG) --+� -- THE NEW EQUIPMENT AS POSSIBLE BEFORE DISTURBING THE NORMAL OPERATION OF THE DATA CENTER. THE FOLLOWING IS A GENERAL A3 IT SHALL THE RESPONSIBILITY EACH CONTRACTOR TO EXAMINE THE CONTRACT DOCUMENTS CAREFULLY BEFORE SUBMITTING THEIR BID, WITH G3 LIGHT SWITCHES / OCCUPANCY SENSORS LOCATED IN A ROOM SHALL CONTROL ALL THE LIGHT FIXTURES IN THAT ROOM UNLESS NOTED OTHERWISE. CONTRACTOR SHALL GANG TOGETHER ALL SWITCHES/DIMMERS UNDER A SINGLE COVER PLATE IN ALL AREAS THAT REQUIRE MORE THAN ONE SWITCH TO SEQUENCE OF INSTALLATION TO BE USED BY THE INSTALLING CONTRACTOR AMMETER SWATCH PARTICULAR ATTENTION TO ERRORS, OMISSIONS, CONFLICTS WITH PROVISIONS OF LAWS AND CODES HAVING JURISDICTION, CONFLICTS BETWEEN DRAWINGS OR R S, INTERLOCK CONTROL ELECTRICAL DEVICES. AS A GUIDELINE IN THEIR PLANNING OF THE OVERALL PROJECT 5 5 DRAWINGS AND SPECIFICATIONS, AND AMBIGUOUS DEFINITION OF THE EXTENT OF COVERAGE BETWEEN CONTRACTS. ANY SUCH DISCREPANCY SHALL BE O VOLTMETER SWITCH INSTALLATION. THE INSTALLING CONTRACTOR SHALL USE THIS GUIDELINE MULTIFUNCTION DIGITAL BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ARCHITECT FOR CORRECTION. SHOULD ANY OF THESE ERRORS, OMISSIONS, CONFLICTS, OR AMBIGUITIES EXIST, THE CONTRACTOR SHALL HAVE THEM EXPLAINED AND ADJUSTED IN WRITING BEFORE SIGNING THE CONTRACT OR PROCEEDING WITH THE WORK; G4 IN INSTANCES WHERE A TRACK LIGHTING SYSTEM, DIMMING SYSTEM, AND /OR LIGHTING CONTROL SYSTEM IS SPECIFIED, THE CONTRACTOR SHALL COORDINATE AS A STARTING POINT FOR PREPARING THE ACTUAL INSTALLATION PLAN. COMMENCEMENT OF WORK. OTHERWISE, THE CONTRACTOR SHALL, AT THEIR OWN EXPENSE, SUPPLY THE PROPER MATERIALS AND LABOR TO MAKE GOOD ANY DAMAGE OR DEFECTS IN UNLESS OTHERWISE INDICATED, CONDUCTOR SIZES #12 AWG AND #10 AWG SHALL BE SOLID. CONDUCTOR SIZES JS AWG AND LARGER MAY BE STRANDED. ALL NECESSARY COMPONENTS OF SUCH SYSTEM(S) WITH THE MANUFACTURER PRIOR TO BID AND INCLUDE ALL NECESSARY ACCESSORIES TO INSTALL A THIS PLAN SHALL BE REVIEWED IN DETAIL WITH THE OWNER SO AS TO POTENTIAL TRANSFORMER THEIR WORK OR THE RESULTS OBTAINED THEREFROM, CAUSED BY SUCH DISCREPANCY. UTILITY METER COMPLETE AND FUNCTIONING SYSTEM. MAKE SURE EVERY PRECAUTION IS TAKEN TO AVOID ANY UNINTENDED A SEPARATE INSULATED EQUIPMENT GROUNDING CONDUCTOR SHALL BE PULLED WITH THE CIRCUIT CONDUCTORS FOR GROUNDING WHETHER OR NOT INDICATED ON THE DRAWINGS METAL RACEWAY, OR A CABLE ARMOR OR SHEATH SHALL NOT BE USED AS THE ONLY EQUIPMENT GROUNDING CONDUCTOR. TRANSIENT VOLTAGE SURGE SYSTEMS) WITHIN THE DEMOLITION AREAS (FLOORS, WALL AND CEILINGS) AS DEPICTED/NOTED ON THE DRAWINGS (ARCHITECTURAL, HVAC, PLUMBING, DISRUPTION OF THE OPERATING DATA CENTER. ONCE THE INSTALLATION A4 WHEREVER CONFLICTS OCCUR BETWEEN DIFFERENT PARTS OF THE CONTRACT DOCUMENTS, THE GREATER QUANTITY, THE BETTER QUALITY, OR LARGER SIZE G5 FOLLOW -UP SERVICE (EXTERIOR AND INTERIOR LIGHTING) STARTS TO POTENTIALLY IMPACT THE OPERATION OF THE DATA CENTER SC_ SHALL PREVAIL UNLESS THE ARCHITECT INFORMS THE CONTRACTOR OTHERWISE IN WRITING. EX mx FINAL AIMING AND ADJUSTING PERFORM ADJUSTMENTS TO ALL AIMABLE AND TRACK MOUNTED LUMINAIRES AS DIRECTED BY THE ARCHITECT TO PROVIDE THE CONTRACTOR SHALL PREPARE DETAILED METHODS OF PROCEDURES R. REQUIRED LIGHT INTENSITIES AND DISTRIBUTIONS. (MOP'S) FOR FINAL REVIEW AND APPROVAL BY THE OWNER. A5 THE SCALE OF EACH DRAWING IS RELATIVELY ACCURATE; ANY DIMENSIONS SHOWN ARE APPROXIMATE TO CENTERLINE FROM ASSUMED BUILDING PERIMETER. APPURTENANCES AND DEVICES TO REMAIN. THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL NECESSARY DEVICES. EQUIPMENT AND ACCESSORIES 1) SCHEDULING AFTER SUBSTANTIAL COMPLETION, BUT NOT MORE THAN THREE MONTHS AFTER FINAL ACCEPTANCE; AFTER DELIVERY AND PLACEMENT OF REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR LOCATION AND MOUNTING HEIGHT OF ALL WALL AND FLOOR MOUNTED ELEMENTS (OUTLETS, ED THE CONTRACTOR SHALL OBTAIN THE NECESSARY DIMENSIONS FOR ANY EXACT TAKEOFFS FROM THE ARCHITECT. NO ADDITIONAL COST TO THE OWNER WILL VARIABLE FREQUENCY DRIVE AMENITIES INCLUDING BUT NOT LIMITED TO FURNITURE, ARTWORK, PLANTINGS, AND SIGNAGE /GRAPHICS; DURING A PERIOD MUTUALLY AGREEABLE TO THE PHASE 1: BE CONSIDERED FOR FAILURE TO OBTAIN EXACT DIMENSIONS WHERE NOT CLEAR OR IN ERROR ON THE DRAWINGS. ANY DEVICE OR FIXTURE ROUGHED IN DIMENSIONED DRAWINGS IF LOCATION FOR AN ITEM IS NOT SHOWN ON THE ARCHITECTURAL DRAWINGS, VERIFY THE EXACT LOCATION OF THE ITEM WITH THE ARCHITECT AND OWNER 1. REMOVE ANY EXISTING FURNITURE, SHELVES, CABINETS ANY ITEMS RECTIFIER / INVERTER IMPROPERLY AND NOT POSITIONED ON IMPLIED CENTER -LINES OR AS REQUIRED BY GOOD PRACTICE MUST BE REPOSITIONED AT NO COST TO THE OWNER. STATIC SWITCH 2) REQUIRED EQUIPMENT: PROVIDE SCAFFOLDING, LADDERS, MOTORIZED MAN -LIFTS OR HOISTS AS REQUIRED TO REACH LUMINAIRES. THAT CAN BE REMOVED TO ACCOMMODATE THE NEW WORK. FROM THESE DRAWINGS 3) RE -LAMP: UTILIZING THE EXTRA MATERIALS FURNISHED UNDER SECTION 265100 AND 265500, RE -LAMP FIXTURES WITH NEW LAMPS HAVING DIFFERING COORDINATE WITH THE OWNER FOR FURTHER REQUIREMENTS. REFER A6 THE CONTRACTOR IS RESPONSIBLE FOR FILING AND PAYING ALL FEES AND OBTAINING NECESSARY PERMITS AND CERTIFICATES OF INSPECTION. THE CIRCUIT BREAKER BEAM- SPREADS AS DIRECTED BY THE ARCHITECT. RETURN ALL UNUSED OR MINIMALLY -USED LAMPS TO THE FACILITIES STOCK AT THE COMPLETION OF TO ARCHITECTURAL DRAWINGS FOR FURTHER REQUIREMENTS. q 1 CONTRACTOR SHALL DELIVER ALL CERTIFICATES OF INSPECTION TO OWNER /CONSTRUCTION MANAGER INCLUDING COPIES WITH MAINTENANCE MANUALS. A. THE AIMING AND ADJUSTMENT AS DIRECTED BY THE OWNER. X CIRCUIT BREAKER SPACE ONLY X G6 OPERATING ROOMS: AT LEAST HALF OF THE FIXTURES SHALL BE PROVIDED WITH BATTERY BACK UP. 2. REMOVE THE OFFICE FURNITURE AND PREPARE SPACE FOR DEMOLTION A7 ONLY EXPERIENCED CRAFTSMEN KNOWLEDGEABLE IN THEIR RESPECTIVE TRADE SHALL PERFORM THE WORK DESCRIBED IN THE CONSTRUCTION DOCUMENTS a X DRAW OUT CIRCUIT BREAKER AND RENOVATION WORK FOR NEW RAMP. COORDINATE WITH THE OWNER FOR FURTHER REQUIREMENTS. REFER TO ARCHITECTURAL AS ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST ADDITION OF NFPA STANDARD 70 (NATIONAL ELECTRICAL CODE). CONTRACTOR SHALL ALSO MECHANICAL H1 & PLUMBING CDORDINnaN REFERENCE THE MEC HANCAL AND PLUMBING DRAWINGS FOR ALL EQUIPMENT NEEDING ELECTRICAL CONNECTIONS. MAKE ALL CONNECTIONS AND PROVIDE DRAWINGS FOR FURTHER REQUIREMENTS. F5 CONFORM TO ALL APPLICABLE LOCAL CODES AND AMENDMENTS. APPROPRIATE WIRE, CONDUIT, AND OVERCURRENT PROTECTION FOR ALL EQUIPMENT. 3. INSTALL NEW POWER DISTRIBUTION TRANSFORMERS AND AS UNLESS OTHERWISE INDICATED, ALL EQUIPMENT AND MATERIALS SHALL BE NEW AND SHALL MEET NEMA AND ANSI STANDARDS. THEY SHALL ALSO BE H2 VERIFY EXACT LOCATION OF ALL POWER CONNECTIONS AND CONTROL DEVICES WITH OTHER TRADES AND MANUFACTURERS SHOP DRAWINGS BEFORE UNINTERRUPTED POWER SYSTEMS (TRANSFORMERS 'T- 21TCLA', UPS -A, X LIS TED /LABELED BY AN NATIONALLY RECOGNIZED LABORATORY IN ACCORDANCE WITH NFPA 70. EQUIPMENT AND MATERIALS SF41 BE INSTALLED IN F6 CONSTRUCTION. COORDINATE ALL REQUIRED ENERGY MANAGEMENT SYSTEM POINTS AND CONTACT CONNECTIONS TO ENSURE THE COMPLETE AND PROPER MAINTENANCE BYPASS PANEL AND PANDLBOARD 21TCLA REFER TO i SWITCH RATING AT FUSE RATING ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, AND WITHIN THEIR LISTING /LABELING REQUIREMENTS AND RESTRICTIONS. CIRCUIT BREAKER OPERATION OF ALL SYSTEMS. ONE -LINE DIAGRAM FOR FURTHER REQUIREMENTS) ALL EQUIPMENT AID PROVIDE SHOP DRAWINGS FOR ENGINEER'S RENEW FOR ALL ELECTRICAL EQUIPMENT, DEVICES, AND MATERIALS PROPOSED TO BE PROVIDED UNDER THIS H3 ALL FUSED SWITCH AND /OR CIRCUIT BREAKERS SERVING EQUIPMENT SHALL HAVE PROVISIONS FOR HANDLE LOCKS. SHALL BE INSTALLED AND FEEDERS RUN AND TERMINATED AT THEIR LSIG ELECTRONIC TRIP CONTRACT. ANY DEVIATIONS FROM ITEMS SPECIFIED SHALL BE CLEARLY IDENTIFIED AND SEPARATELY SUBMITTED WITH A FORMAL SUBSTITUTION REQUEST AT =TRIP RATING RESPECTIVE SOURCE PROVIDE NEW CONDUIT AND RECEPTACLE REFER TO SPECIFICATIONS (PROJECT MANUAL) FOR REQUIREMENTS. H4 ALL CIRCUIT BREAKERS SERVING MECHANICAL EQUIPMENT SHALL BEAR AN 'HACR' RATING. UNDER RAISED FLOOR FOR EACH RACK. WORK SHALL BE DONE ONE 12 REQUIREMENTS OF LOCAL UTILITY COMPANY CIRCUIT BREAKER RACK AT A TIME TO ENSURE THE MOST MINIMAL DOWN TIME AS All CONTRACTOR SHALL CONNECT ALL MV VALVES, BACKFLOW PREVENTERS, AND FLOW AND TAMPER SWITCHES TO THE NEW FIRE ALARM SYSTEM. H5 ALL DISCONNECTS DOWN STREAM OF VFD: SHALL BE PROVIDED WITH AUXILIARY CONTACTS TO SHUT DOWN UPSTREAM VFD WHEN SWITCH IS OPENED. POSSIBLE. TRIP R� CONTRACTOR SHALL PROVIDE AN AUDIBLE AND VISUAL ALARM RIGHT OUTSIDE THE FIRE PUMP ROOM AND INTERCONNECT WITH FIRE ALARM SYSTEM. REFER REFER TO DESCRIPTION X TO FIRE PROTECTION AND CIVIL DRAWINGS FOR QUANTITY AND LOCATION OF DEVICES H` COORDINATE BETWEEN TRADES AND PROVIDE CONTROL POWER FOR ALL VAV BOXES/DAMPERS/ETC, AS REQUIRED TO ENSURE A COMPLETE, FULLY 4. PRIOR TO REMOVAL OF THE CEILING THE FM 200 NEEDS TO BE 17. BUILDING CODE: FLORIDA BUILDING CODE (2007) FUNCTIONS FUNCTIONAL HVAC SYSTEM. SHOULD AN EXACT CIRCUIT NUMBER NOT BE INDICATED ON ELECTRICAL DRAWINGS, CONTRACTOR SHALL UTILIZE AVAILABLE UPGRADED AND FULLY OPERATIONAL TO ENSURE PROPER COVERAGE Al2 DISCONNECT SWITCHES ARE SHOWN FOR REFERENCE PURPOSES ONLY. REFER TO MECHANICAL DRAWINGS, MECHANICAL SPECIFICATIONS AND RESPONSIBILITY 2OA /1P SPACE FROM THE NEAREST 208V/120V PANEL OR FROM BUILDING CONTROL POWER DISTRIBUTION SYSTEM. FOR THE ADDITIONAL VOLUME ADDED TO THE ROOM. MATRIX FOR ADDITIONAL INFORMATION. ALSO, REFER TO NOTE A4 ABOVE. AUTOMATIC TRANSFER 5. REMOVE THE CEILING TILE AND GRID. REFER TO ARCHITECTURAL A13 CONTRACTOR TO PROVIDE TEMPORARY EMERGENCY CRITICAL POWER TO ALL NEGATIVE AIR MACHINES DEMOLITION NOTES: DRAWINGS FOR FURTHER REQUIREMENTS PROVIDE TEMPORARY B. CODES AND STANDARDS REFERRED TO ARE MINIMUM. WHERE THE REQUIREMENTS OF THE DRAWINGS OR SPECIFICATIONS EXCEED THOSE OF THE CODES SWITCH W/O BYPASS SUPPORT FOR ANY CABLING THAT IS EXISTING TO REMAIN WITHIN ELJ_CTRICLL EQUIPMENT A. CONTRACTOR SHALL UPDATE ALL ELECTRICAL PANEL SCHEDULES AFFECTED BY THIS DEMOLITION. HAND WRITTEN SCHEDULES ARE NOT ACCEPTED. CEILING SPACE 11 PROVIDE AN IDENTIFICATION NAMEPLATE FOR EACH ELECTRICAL EQUIPMENT, APPURTENANCE DEPICTING THE DESIGNATION INDICATED ON THE DRAWINGS SCHEDULES SHALL BE TYPED OR COMPUTER GENERATED. REFER TO SPECIFICATIONS FOR FURTHER REQUIREMENTS 6. UPGRADE OF THE STORM DRAIN PIPE SHALL BE DONE REFER TO B. ALL CIRCUITS SHOWN ARE FOR REFERENCE PURPOSES ONLY. CONTRACTOR SHALL VERIFY ALL CIRCUITS TO BE REMOVED PRIOR TO COMMENCEMENT P2.02 FOR FURTHER REQUIREMENTS. 12 WEATHERPROOF ENCLOSURES SHALL BE PROVIDED FOR ALL ELECTRICAL EQUIPMENT, DEVICES AND APPURTENANCES (ALL SYSTEMS) INSTALLED OUTDOORS. OF WORK, 7. INSTALL THE NEW CABLE TRAY REFER TO CM DRAWINGS FOR FURTHER 13 COORDINATE AND SCHEDULE ALL POWER OUTAGES WITH OWNER. REFER TO SPECIFICATIONS FOR FURTHER REQUIREMENTS C. THE CONTRACT DOCUMENTS DO NOT PROPOSE TO SHOW ALL EXISTING SYSTEMS, MATERIAL OR EQUIPMENT. IT IS THE RESPONSIBILITY OF THE REQUIREMENTS. SUPPPORT LOW VOLTAGE CABLING TO REMAIN FROM ELECTRICAL CONTRACTOR TO OBTAIN DATA RELATED TO EXISTING CONDITIONS FROM EXISTING DOCUMENTS, NOTATIONS, PHOTOGRAPHS, SURVEYS NEW CABLE TRAY. B4 .SPACE ALLOCATIONS FOR MATERIALS, EQUIPMENT AND DEVICES HAVE BEEN MADE ON THE BASIS OF PRESENT AND KNOWN FUTURE REQUIREMENTS AND THE AND OTHER OBSERVATIONS AT THE SITE. DIMENSIONS OF ITEMS OF EQUIPMENT OR DEVICES OF A PARTICULAR MANUFACTURER. THE CONTRACTOR SHALL VERIFY THAT ALL MATERIALS, EQUIPMENT S. WHEN INSTALLING NEW BREAKERS ASSOCIATED WITH AC -1 AND CU -1, AND DEVICES PROPOSED FOR USE ON THIS PROJECT ARE WITHIN THE CONSTRAINTS OF THE ALLOCATED SPACE. D. REMOVE EXISTING WIRE, CONDUIT, EQUIPMENT, FIXTURES AND OTHER ITEMS TO PROVIDE ACCESS FOR WORK IN EXISTING FACILITIES. REINSTALL AND PROVIDE SPOT COOLERS AS REQUIRED TO PREVENT UPS ROOMS AND B5 DO NOT USE PERMANENT INK WHEN MAKING FIELD MARKINGS OR TEMPORARY CIRCUIT LABELS ON PANELS. CONTRACTOR SHALL USE REMOVABLE TAPE/TAGS REFINISH ITEMS REMOVED, OR OTHERWISE DAMAGED, TO MATCH EXISTING AT NO ADDITIONAL COST TO OWNER. SERVER ROOMS FROM OVER HEATING. THE INTENT IS TO INSTALL THE NEW AC -1 AND CU -1 PRIOR TO REMOVING THE EXISTING UEBERT FOR ALL TEMPORARY MARKINGS AND SHALL REMOVE THESE TEMPORARY MARKINGS AT THE CONCLUSION OF THIS PROJECT. E WHERE EXISTING FUNCTIONS TO REMAIN IN USE ARE DISRUPTED, THEY SHALL BE FULLY RESTORED AFTER DISRUPTION, IN FULL COMPLIANCE WITH UNIT. COORDINATE SHUT DOWN OF LIEBE RT UNIT AND TRANE UNIT SIM-= APPLICABLE CODES AND STANDARDS WITH OWNER. Cl COORDINATE WITH THE SITE WORK FOR THE LOCATION, DIMENSIONS AND ELEVATION OF ALL DUCTBANKS /SERVICE CONDUITS EXTERNAL TO THE BUILDING F. MODIFY REMOVE, OR RELOCATE MATERIALS AND ITEMS INDICATED ON THE DRAWINGS OR REQUIRED DUE TO THE DEMOLITION WORK. Q. UPON COMPLETION OF THE ABOVE MENTIONED WORK AN MCA PRIOR TO INSTALLATION OF ALL DUCTBANKS/SERNCE CONDUITS INTERNAL TO THE BUILDING. , INSPECTION SHALL BE SCHEDULED. C2 COORDINATE ALL ELECTRICAL UTILITY SERVICE REQUIREMENTS WITH UTILITIES REPRESENTATIVE PRIOR TO COMMENCING ANY ELECTRICAL SITE WORK. G. WORK JOINTLY WITH THE ARCHITECT, ESTABLISH AND MARK SALVAGE AND DEMOLITION ITEMS BEFORE COMMENCING WORK; REPORT ITEMS SCHEDULE CONTRACTOR SHALL SCHEDULE ALL NECESSARY MEETINGS BETWEEN UTILITY COMPANIES CONSTRUCTION FOREMAN, ELECTRICAL SUBCONTRACTORS, AND FOR RELOCATION, REINSTALLATION OR REUSE, WHICH ARE FOUND TO BE IN DAMAGED CONDITION; AWAIT FURTHER INSTRUCTIONS FROM THE PHASEZ-, VARIOUS SUBCONTRACTORS RESPONSIBLE FOR SITE CONSTRICTION PRIOR TO ELECTRICAL ROUGH -IN. ARCHITECT BEFORE COMMENCING WITH WORK. 1. THE RACK RELOCATION AND /OR NEW INSTALLATION CAN COMMENCE FOR FURTHER REQUIREMENTS AND PROVIDE COORDINATE WITH OWNER FOR CONDUIT RACEWAY RACEWAY H. DEMOLITION EQUIPMENT, DEVICES AND MATERIAL SHALL BE REMOVED FROM THE SITE AND DISPOSED OF BY THE CONTRACTOR. SALVAGED EQUIPMENT A MINIMUM OF 14 DAYS NOTICE PHASE THE RACK AS NECESSARY D1 ALL WORK SHALL BE COORDINATED SO THAT INTERFERENCES ARE AVOIDED. PROVIDE ALL NECESSARY OFFSETS IN CONDUITS, RACEWAYS, ETC., REQUIRED AND DEVICES SHALL BE THE PROPERTY OF THE OWNER UNLESS NOTED OTHERWISE. AND REQUIRED TO ENSURE NO DOWN TIME TO PROPERLY INSTALL THE WORK. EXPOSED WORK MUST BE KEPT AS CLOSE AS POSSIBLE TO WALLS, CILINGS, COLUMNS, ETC., SO AS TO TAKE UP MINIMUM AMOUNT OF SPACE; ALL OFFSETS, FITTINGS, ETC., REQUIRED SHALL BE PROVIDED WITHOUT ADDITIONAL EXPENSE TO THE OWNER. WORK SHALL BE 1. MAKE RELOCATION NECESSITATED BY THE CONDITIONS AT THE SITE OR AS DIRECTED BY THE ARCHITECT, WITHOUT ADDITIONAL COST TO THE OWNER. 2. REMOVE ANY EXISTING CONDUITS, RECEPTACLES, LOW VOLTAGE WIRING, COORDINATED WITH OTHER TRADES. REPAIR, REPLACE AND /OR RESTORE TO GOOD FUNCTIONAL CONDITION, EQUIPMENT, MATERIAL AND ITEMS SCHEDULE FOR RELOCATION, WHICH ARE HVAC EQUIPMENT (LIEBERT UNIT) AND ASSOCIATED DISCONNECTS DAMAGED DURING DISMANTLING OR REASSEMBLE OPERATIONS. PROVIDE NEW MATERIALS, FITTINGS AND APPURTENANCES REQUIRED TO COMPLETE THE THAT CAN BE DEMOLISHED BASED ON THE PHASE 1 COMPLETION. D2 CONDUIT RUNS ARE DIAGRAMMATIC IN NATURE CONTRACTOR IS RESPONSIBLE FOR SIZING AND LOCATING PULL BOXES PER NFPA 70 AND FOR RELOCATION AND TO RESTORE TO GOOD OPERATING ORDER. PERFORM THE RELOCATION WORK IN ACCORDANCE TO APPLICABLE CODES ASD THERE SHALL BE NO DOWNTIME DUE TO THIS DEMOLTION. COORDINATION WITH OTHER DISCIPLINES STANDARDS, USING SKILLED WORKERS. 3. ONCE ALL THE RACKS HAVE BEEN RELOCATED AND /OR NEW RACKS D3 PENETRATIONS OF WALLS, FLOORS, AND ROOFS FOR THE PASSAGE OF ELECTRICAL RACEWAYS SHALL BE APPROVED BY THE STRUCTURAL ENGINEER OF J. RELOCATING DEVICES: REMOVE AND REINSTALL IN LOCATIONS DESIGNATED BY THE ARCHITECT, TEMPERATURE CONTROL SYSTEM DEVICES, RELAYS, INSTALLED IN THEIR FINAL OPERATIONAL POSITION (ELECTRICAL AND RECORD PRIOR TO THE COMMENCEMENT OF WORK. ALL SUCH PENETRATIONS SHALL BE PROPERLY SEALED OFF AFTER INSTALLATION OF RACEWAY SO AS TO MAINTAIN THE STRUCTURAL, WATER PROOF, AND FIRE PROOF INTEGRITY OF THE WALL, FLOOR, OR ROOF SYSTEM PENETRATED. WIRE CONDUIT, FIXTURES, EQUIPMENT AND OTHER DEVICES REQUIRED FOR THE OPERATION OF THE VARIOUS SYSTEMS THAT ARE INSTALLED IN LOW VOLTAGE CONNECTED) REMOVE PANELBOARDS UPS -B, C AND EXISTING TO BE REMOVED CONSTRUCTION. A -IT RECESSED IN COLUMN). ( ) D4 SEAL ALL CONDUITS THAT PENETRATE THE BASEMENT FLOOR SW TO MAKE THEM WATER TIGHT. THE CONDUITS SHALL BE DRIED PRIOR TO INSTALLATION K. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SUPPORTING OF EXISTING CONDUITS AND WIRING ABOVE CEILING SPACES WITHIN THE SCOPE OF OF WIRE /CABLE AND SHALL BE SEALED AT TERMINATIONS. THE PROJECT TO COMPLY WITH CURRENT CODES, PROVIDE AN ALLOWANCE FOR 110,000.00 FOR SUCH RESUPPORTING. ALL LABOR AND MATERIALS 4. INSTALL NEW POWER DISTRIBUTION TRANSFORMERS AND UNINTERRUPTED POWER SYSTEMS (PANELBOARD 21TCLB AND PRIMARY D5 ALL PENETRATIONS THROUGH FIRE RATED WALLS OR PARTITIONS SHALL BE MADE IN ACCORDANCE WITH U.L "FIRE RESISTANCE DIRECTORY. PENETRATIONS TO BE CHARGED TO ALLOWANCE SHALL BE DOCUMENTED AND APPROVED BY ENGINEER OR ARCHITECT PRIOR TO WORK. ANY ALLOWANCE NOT USED FEEDERS TO 480 VOLT DISCONNECT (REFER TO ONE -LINE DIAGRAM SHALL BE SLEEVED AND SEALED WITH A UL APPROVED FIRE RATED SEALANT. REFER TO ARCHITECTURAL PLANS FOR FIRE RATED WAILS SHALL BE CREDITED TO OWNER. FOR FURTHER REQUIREMENTS) ALL EQUIPMENT SHALL BE INSTALLED D` ALL EMPTY CONDUIT SYSTEMS SHALL CONTAIN A PULL TAPE FOR FUTURE PUWNG OF CONDUCTORS. L ANY EXISTING JUNCTION BOXES OR RACEWAYS WHICH WILL REMAIN AFTER DEMOUTION, SHALL IDENTIFY CIRCUIT AND BE COLOR CODED PER AND FEEDERS RUN AND TERMINATED AT THEIR RESPECTIVE SOURCE. SPECIFICATIONS PROVIDE COVER PLATED AS REQUIRED THROUGHOUT. PROVIDE NEW CONDUIT AND RECEPTACLE UNDER RAISED FLOOR FOR D7 ALL CONDUT SHALL RE RUN PARAI 1 M AND PE WOMILAR 70 WWA FLOOR AND OYMEAD, EACH RACK. M. ALL EXISTING COVER PLATES FOR RECEPTACLES AND SWITCHES REMAINING IN THE SCOPE OF WORK AREA AFTER DEMOLITION SHALL BE REPLACED DI AL PWMATIONS ARE TO BE AT RIGHT ANGLES WITH THE SAME COVER PLATES BEING USED FOR NEW WORK. PROVIDE ENGRAVING PER SPECIFICATIONS. 5. INSTALL NEW AC -2 AND CU -2, COORDINATE SHUT DOWN OF UENERT ONE -LINE DIAGRAM & RISER SYMBOLS LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION CIRCUITING IS SHOWN DIAGRAMMATICALLY. HOMERUNS SHALL BE COMBINED WHERE POSSIBLE IN ACCORDING TO NFPA 70. CAPACITOR O AMMETER (ANALOG) --+� -- CONTACTOR O VOLTMETER (ANALOG) UNLESS OTHERWISE INDICATED, ALL CIRCUITS 100' OR LESS SHALL BE MINIMUM 110 AWG WIRE SIZE. CIRCUITS OVER 100' BUT LESS THAN 200' SHALL BE ELECTRIC KIRK KEY AS AMMETER SWATCH MINIMUM #10 AWG WIRE SIZE CIRCUITS OVER 200' BUT LESS THAN 300' SHALL BE MINIMUM iA AWG WIRE SIZE INTERLOCK 5 5 CURRENT TRANSFORMER O VOLTMETER SWITCH DPM CM MULTIFUNCTION DIGITAL ## INSTRUMENT RELAY DEVICE METERING MONITOR COMMENCEMENT OF WORK. H DENOTES DEVICE TYPE UNLESS OTHERWISE INDICATED, CONDUCTOR SIZES #12 AWG AND #10 AWG SHALL BE SOLID. CONDUCTOR SIZES JS AWG AND LARGER MAY BE STRANDED. WATT HOUR METER "" POTENTIAL TRANSFORMER ® UTILITY METER THE CONTRACTOR SHALL REMOVE ALL ELECTRICAL APPURTANANCES, DEVICES AND ACCESSORIES (POWER, LIGHTING, COMMUNICATIONS, AND TVSS A SEPARATE INSULATED EQUIPMENT GROUNDING CONDUCTOR SHALL BE PULLED WITH THE CIRCUIT CONDUCTORS FOR GROUNDING WHETHER OR NOT INDICATED ON THE DRAWINGS METAL RACEWAY, OR A CABLE ARMOR OR SHEATH SHALL NOT BE USED AS THE ONLY EQUIPMENT GROUNDING CONDUCTOR. TRANSIENT VOLTAGE SURGE SYSTEMS) WITHIN THE DEMOLITION AREAS (FLOORS, WALL AND CEILINGS) AS DEPICTED/NOTED ON THE DRAWINGS (ARCHITECTURAL, HVAC, PLUMBING, STRUCTURAL AND ELECTRICAL). ALL OTHER AREAS SHALL REMAIN -AS ISM AND ALL ELECTRICAL APPURTENANCES, DEVICES AND ACCESSORIES SHALL SUPPRESSION DEVICE HOMERUN CIRCUITS FOR ISOLATED GROUND RECEPTACLES SHALL BE SEPARATED FROM OTHER CIRCUITS, EACH CIRCUIT SHALL HAVE ITS OWN NEUTRAL FEEDER TAG. REFER TO SC_ NEUTRAL REMOVABLE LANK EX mx FEEDER SCHEDULE FOR R. THE CONTRACTOR SHALL VEEdFY THAT EXISTING CIRCUIT WIRING TO BE REMOVED DO NOT DISRUPT SERVICE TO EXISTING ELECTRICAL WRING DEICES NUMBER AND SIZE OF APPURTENANCES AND DEVICES TO REMAIN. THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL NECESSARY DEVICES. EQUIPMENT AND ACCESSORIES CONDUCTORS AND CONDUIT. REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR LOCATION AND MOUNTING HEIGHT OF ALL WALL AND FLOOR MOUNTED ELEMENTS (OUTLETS, ED REQUIRED TO MAINTAIN SERVICE TO ALL EXISTING TO REMAIN ELECTRICAL APPURTENANCES, DEVICES AND EQUIPMENT. VARIABLE FREQUENCY DRIVE T BATTERY MOV DIMENSIONED DRAWINGS IF LOCATION FOR AN ITEM IS NOT SHOWN ON THE ARCHITECTURAL DRAWINGS, VERIFY THE EXACT LOCATION OF THE ITEM WITH THE SURGE ARRESTER THE CONTRACTOR SHALL REMOVE ALL CONDUIT AND WIRES ASSOCIATED WITH DEVICES AND EQUIPMENT TO BE REMOVED, BACK TO SOURCE RECTIFIER / INVERTER ARCHITECT PRIOR TO INSTALLATION. THESE REQUIREMENTS APPLY TO ALL WALL/FLOOR TYPES IN ALL AREAS. DO NOT SCALE OR DIMENSION LOCATIONS STATIC SWITCH FROM THESE DRAWINGS TRANSFORMER COORDINATE THE LOCATION AND INSTALLATION DETAIL OF OUTLETS IN MILLWORK WITH ARCHITECTURAL DRAWINGS (WALL ELEVATIONS, MILLWORK DETAILS, GROUNDING ELECTRODE v X CIRCUIT BREAKER FUSE q 1 AT = TRIP RATING A. THE SCOPE OF THE WORK SHALL INCLUDE THE FURNISHING AND INSTALLATION OF THE NECESSARY MATERIAL AND LABOR TO ACCOMPLISH THE WORK X CIRCUIT BREAKER SPACE ONLY X SWITCH - NON FUSED �•+ % X i X AL FRAME RATING -- X = SWITCH RATING a X DRAW OUT CIRCUIT BREAKER X FUSED SWITCH X AE FRAME RATING X i SWITCH RATING AT FUSE RATING F5 AT TRIP RATING 4. UNDERWRITERS LABORATORIES, INC. PUBLICATIONS (UL) X CIRCUIT BREAKER W/ R X FUSED SWITCH W/ X THERMAL OVERLOAD DEVICE X GROUND FAULT RELAY F6 ff- FRAME RATING AT TRIP RATING i SWITCH RATING AT FUSE RATING CIRCUIT BREAKER b & INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE) \ X X J X AE FRAME RATING AT TRIP RATING X � rF CIRCUIT BREAKER W/ EXTERNAL GROUND FAULT MODULE X X LSIG ELECTRONIC TRIP AT =TRIP RATING FUNCTIONS 11. NATIONAL ELECTRICAL SAFETY CODE (NIS Hsn&o& 81) DRAW OUT 12 REQUIREMENTS OF LOCAL UTILITY COMPANY CIRCUIT BREAKER 13. FLORIDA ADMINISTRATIVE CODE 59A -3, (Mwdi 2003) X AT ATING� TRANSFER SWITCH X TRIP R� REFER TO DESCRIPTION X FOR FEATURES LSIG ELECTRONIC TRIP 17. BUILDING CODE: FLORIDA BUILDING CODE (2007) FUNCTIONS WITH 2008 AND 2009 REVISIONS AUTOMATIC TRANSFER AUTOMATIC TRANSFER • 20. FIRE MARSHALL'S RULE 4A3.012 F.A.C. adopted January 1, 2001 SWITCH W/ B. CODES AND STANDARDS REFERRED TO ARE MINIMUM. WHERE THE REQUIREMENTS OF THE DRAWINGS OR SPECIFICATIONS EXCEED THOSE OF THE CODES SWITCH W/O BYPASS AND REGULATIONS, THE DRAWINGS AND SPECIFICATIONS GOVERN. BYPASS ISOLATION ISOLATION UNIT AND TRANS UNIT WITH OWNER. BRANCH CIRCUITS-Aw FEEDERS - N. CONTRACTOR SHALL MAINTAIN Inc. INTEGId1Y OF THE LA51ING FIRE ALARM SYSTEM DURING CoN31RUC110N. El CIRCUITING IS SHOWN DIAGRAMMATICALLY. HOMERUNS SHALL BE COMBINED WHERE POSSIBLE IN ACCORDING TO NFPA 70. 6. UPON COMPLETION OF THE ABOVE MENTIONED WORK AN MCA L Z 0. ANY DATA/TELEPHONE OUTLET THAT WILL REMAIN AFTER DEMOLITION IN THE SCOPE OF WORK AREA SHALL BE REPLACED WITH TYPE USED FOR INSPECTION SHALL BE SCHEDULED. E2 UNLESS OTHERWISE INDICATED, ALL CIRCUITS 100' OR LESS SHALL BE MINIMUM 110 AWG WIRE SIZE. CIRCUITS OVER 100' BUT LESS THAN 200' SHALL BE NEW WORK. REFER TO SPECIFICATIONS. LL. MINIMUM #10 AWG WIRE SIZE CIRCUITS OVER 200' BUT LESS THAN 300' SHALL BE MINIMUM iA AWG WIRE SIZE z R THE CONTRACTOR SHALL FIELD VERIFY ALL EXISITING CONDITIONS WITHIN THE DEMOUTION AREAS DEPICTED IN THE DEMOUTION DRAWINGS AND E2 UNLESS OTHERWISE INDICATED, ALL CONDUCTORS SHALL BE COPPER, 91% CONDUCTIVITY CONTINUOUS FROM OUTLET TO OUTLET. SHALL ASCERTAIN THE EXTENT OF WORK REQUIRED WITHIN THE DEMOLITION AND EXISTING TO REMAIN AREAS PRIOR TO PRICING AND COMMENCEMENT OF WORK. E3 UNLESS OTHERWISE INDICATED, CONDUCTOR SIZES #12 AWG AND #10 AWG SHALL BE SOLID. CONDUCTOR SIZES JS AWG AND LARGER MAY BE STRANDED. Q. THE CONTRACTOR SHALL REMOVE ALL ELECTRICAL APPURTANANCES, DEVICES AND ACCESSORIES (POWER, LIGHTING, COMMUNICATIONS, AND E4 A SEPARATE INSULATED EQUIPMENT GROUNDING CONDUCTOR SHALL BE PULLED WITH THE CIRCUIT CONDUCTORS FOR GROUNDING WHETHER OR NOT INDICATED ON THE DRAWINGS METAL RACEWAY, OR A CABLE ARMOR OR SHEATH SHALL NOT BE USED AS THE ONLY EQUIPMENT GROUNDING CONDUCTOR. SYSTEMS) WITHIN THE DEMOLITION AREAS (FLOORS, WALL AND CEILINGS) AS DEPICTED/NOTED ON THE DRAWINGS (ARCHITECTURAL, HVAC, PLUMBING, STRUCTURAL AND ELECTRICAL). ALL OTHER AREAS SHALL REMAIN -AS ISM AND ALL ELECTRICAL APPURTENANCES, DEVICES AND ACCESSORIES SHALL E5 HOMERUN CIRCUITS FOR ISOLATED GROUND RECEPTACLES SHALL BE SEPARATED FROM OTHER CIRCUITS, EACH CIRCUIT SHALL HAVE ITS OWN NEUTRAL REMAIN OPERATIONAL CONDUCTOR AND EACH HOMERUN SHALL CONTAIN AN ISOLATED AND EQUIPMENT GROUND CONDUCTOR. R. THE CONTRACTOR SHALL VEEdFY THAT EXISTING CIRCUIT WIRING TO BE REMOVED DO NOT DISRUPT SERVICE TO EXISTING ELECTRICAL WRING DEICES APPURTENANCES AND DEVICES TO REMAIN. THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL NECESSARY DEVICES. EQUIPMENT AND ACCESSORIES F1 REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR LOCATION AND MOUNTING HEIGHT OF ALL WALL AND FLOOR MOUNTED ELEMENTS (OUTLETS, REQUIRED TO MAINTAIN SERVICE TO ALL EXISTING TO REMAIN ELECTRICAL APPURTENANCES, DEVICES AND EQUIPMENT. LIGHT SWITCHES, CONTROLLERS, POKE -THRU, ETC). ALL WALL/FLOOR MOUNTED ITEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE ARCHITECTURAL DIMENSIONED DRAWINGS IF LOCATION FOR AN ITEM IS NOT SHOWN ON THE ARCHITECTURAL DRAWINGS, VERIFY THE EXACT LOCATION OF THE ITEM WITH THE S. THE CONTRACTOR SHALL REMOVE ALL CONDUIT AND WIRES ASSOCIATED WITH DEVICES AND EQUIPMENT TO BE REMOVED, BACK TO SOURCE ARCHITECT PRIOR TO INSTALLATION. THESE REQUIREMENTS APPLY TO ALL WALL/FLOOR TYPES IN ALL AREAS. DO NOT SCALE OR DIMENSION LOCATIONS FROM THESE DRAWINGS F2 COORDINATE THE LOCATION AND INSTALLATION DETAIL OF OUTLETS IN MILLWORK WITH ARCHITECTURAL DRAWINGS (WALL ELEVATIONS, MILLWORK DETAILS, APPLICABLE CODES ETC.) AND NTH MILLWORK MANUFACTURER PRIOR TO ELECTRICAL ROUGH -IN. A. THE SCOPE OF THE WORK SHALL INCLUDE THE FURNISHING AND INSTALLATION OF THE NECESSARY MATERIAL AND LABOR TO ACCOMPLISH THE WORK F3 WALL AND FLOOR MOUNTED POWER RECEPTACLES SHOWN NEAR DATA OUTLETS SHALL BE LOCATED WITHIN SIX (6) INCHES OF THE DATA OUTLET. LOCATE INDICATED BY THE DRAWINGS AND HEREIN SPECIFIED. ALL WORK BY CONTRACTOR SHALL CONFORM TO ALL APPLICABLE FEDERAL, STATE AND LOCAL AT SAME MOUNTING HEIGHT UNLESS NOTED OTHERWISE BUILDING CODES AND STANDARDS INCLUDING BUT NOT LIMITED T0: F4 VERIFY THE EXACT POWER CONNECTION ME AND NEMA CONFIGURATION OF RECEPTACLES FOR EQUIPMENT FURNISHED BY THE OWNER, OTHER TRADES, OR 1. STATE OF FLORIDA 2. CITY OF MIAMI UNDER A SEPARATE SECTION OF THIS CONTRACT PRIOR TO ELECTRICAL ROUGH -IN. 3. LIFE SAFETY CODE - NFPA 101 (2006) F5 ALL RECEPTACLES LOCATED OUTSIDE THE BUILDING ENVELOPE SHALL BE HOUSED IN ENCLOSURES THAT ARE RATED 'WEATHER- PROOF - WHILE -IN -USE' AND 4. UNDERWRITERS LABORATORIES, INC. PUBLICATIONS (UL) SHALL BE EQUIPPED WITH GFCI FOR PERSONNEL PROTECTION. 5. NATIONAL FIRE PROTECTION ASSOCIATION. (NFPA) 6. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) F6 ALL GFCI RECEPTACLES SHALL BE CONNECTED SO THAT ALL DEVICES ON THE SAME CIRCUIT AS THE GFCI RECEPTACLE DO NOT DE- ENERGIZE UPON 7. NATIONAL ELECTRICAL CODE - NFPA 70 (2008) TRIPPING. ALL GFCI RECEPTACLES SHALL INCLUDE A LOCK -OUT FUNCTION TO PROTECT AGAINST THE USE OF MISWIRED DEVICES OR DEVICES THAT HAVE & INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE) BEEN DAMAGED DUE TO DISABLING SURGES. 9. NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION (NEMA) F7 ALL RECEPTACLES WITHIN 6 FT OF ANY WATER SOURCE CIE SINKS, ETC) SHALL BE OF THE GFCI TYPE 10. INTERNATIONAL POWER CABLE ENGINEER'S ASSOCIATION (IPCEA) 11. NATIONAL ELECTRICAL SAFETY CODE (NIS Hsn&o& 81) 12 REQUIREMENTS OF LOCAL UTILITY COMPANY 13. FLORIDA ADMINISTRATIVE CODE 59A -3, (Mwdi 2003) 14. NATIONAL FIRE PROTECTION ASSOCIATION 72 (2002) 15. NATIONAL FIRE PROTECTION ASSOCIATION 99 (2005) 16. THE STATE FIRE PREVENTION CODE, 4A60 (2001) 17. BUILDING CODE: FLORIDA BUILDING CODE (2007) WITH 2008 AND 2009 REVISIONS It AIA GUIDELINES (2006) 19. NFPA 110 (2005) 20. FIRE MARSHALL'S RULE 4A3.012 F.A.C. adopted January 1, 2001 B. CODES AND STANDARDS REFERRED TO ARE MINIMUM. WHERE THE REQUIREMENTS OF THE DRAWINGS OR SPECIFICATIONS EXCEED THOSE OF THE CODES AND REGULATIONS, THE DRAWINGS AND SPECIFICATIONS GOVERN. • • ... 0 0000 . •.s•r rrs f • i • (! I VWOPIS • r• 0000 -� Y 'Y •rY w • V • 0000'• 11 /J /A� \ \aru r••• f • • 4L* 0 *so Z �a RN 0< , r t A� F•I v' 00 z U.] C4 0% 4 LLJd Z �x <� <0 h� V .00.1 p PE" MEMO! as' W 0 � con W 0 oil .4.00L :164 41 0 t� AHCA STAGE 111 12/13/13 DRAMIIW CORD QHICKDe CCRD DA'1111e 12 -13 -13 13CM24 AS SWOWN Ci f 01 A Shut No. E0.01 lO # z O V L Z a �..i rLL3 V ad O LL. Lm z AHCA STAGE 111 12/13/13 DRAMIIW CORD QHICKDe CCRD DA'1111e 12 -13 -13 13CM24 AS SWOWN Ci f 01 A Shut No. E0.01 lO #