14-523-028vEXrE�I0R U L SCALE, 1/4' = 1' -0' y TH i FIRE PROTECTION SYMBOLS ALL SYMBOLS SHOWN MAY NOT APPEAR IN ALL DRAWINGS. SYMBOLS ARE SHOWN SCHEMATIC AND MAY NOT BE TO SCALE. SYMBOL DESCRIPTION --- EX — EXISTING PIPING TO REMAIN -- -- -- - - EXISTING PIPING TO BE REMOVED CONNECT NEW TO EXISTING DISCONNECTION POINT ---- F --- FIRE PROTECTION (STANDPIPE, SPRINKLER, SERVICE) —DFS— DRY FIRE STANDPIPE PIPING — SP — SPRINKLER PIPING (SPRK.) --- SDR ---- SPRINKLER DRAIN RISER PIPING —DSP— DRY SPRINKLER PIPING 4-- ++- GATE VALVE 064 GLOBE GLOBE VALVE • PRESSURE REGULATION VALVE (PRV) --- CHECK VALVE WITH AUTOMATIC BALL DRIP CCU }I VALVE IN VERTICAL � OS & Y VALVE SUPERVISED (HORIZ. POSITION/VERT. POSITION) I INDICATING BUTTERFLY VALVE SUPERVISED (HORIZ. POSITTON/VERT. POSITION) -- LFLI� --- SPRINKLER SYSTEM FLOOR CONTROL ASSEMBLY - DOUBLE CHECK VALVE ASSEMBLY (D.C.V.A.) WITH OS h Y VALVES SUPERVISED - - FLOW SWITCH O X FIRE HOSE VALVE rrrrnm FIRE HOSE CABINET (SURFACE MOUNTED) -mmm3:r-- FIRE HOSE CABINET (RECESSED) 2--WAY SIAMESE FIRE DEPARTMENT CONNECTION DIRECTION OF SLOPE —�-- DIRECTION OF FLOW - ----•� CAP OUTLET OR PLUGGED OUTLET ---- UNION ABBREVIATIONS AFF MOVE FINISH FLOOR AFG MOVE FINISH GRADE A/C MOVE HUNG CEILING AP ACCESS PANEL OR DOOR BFF BELOW FINISH FLOOR STP STANDPIPE PRV PRESSURE REDUCING VALVE SFCA SPRINKLER FLOOR CONTROL VALVE ASSEMBLY Project #:413508.000 / • Y r . . / . • x, 2121 Ponce de Leon kulejarn Suite 350 W • • ! Coral Gables, FL 33134 r• phone: 305.569.1692 fax: 305.569.1693 ! • • • ! • InhYgnil GnulYry in�ItNers • Austin . Dallas . Denver . Houston . Kansas City . S`aliamio Nashville . Phoenix . Richmond . Washi4, ton o.C.V. F400007658 i• /! •!� Y / FIRE PROTECTION NOTES i 1. PROVIDE WORKING DRAWINGS FROM THE ENGINEERED CONTRACT DRAWINGS AND SPECIFICATIONS. THE DRAWINGS SHALL FEET ALL OF THE REQUIREMENTS FOR WORKING DRAWINGS PER NFPA 13 AND NFPA 2001. PROVIDE SPRINKLERS / DISCHARGE NOZZLES AND PIPING IN LOCATIONS AND CONFIGURATION INDICATED; HOWEVER, THE CONTRACTOR SHALL COORDINATE THE LOCATION AND ELEVATION OF ALL SPRINKLERS / DISCHARGE NOZZLES AND PIPING WITH ALL BUILDING COMPONENTS AND SYSTEMS. PIPE SIZES SHALL NOT BE LESS THAN INDICATED ON THE DRAWINGS. 2. OBTAIN A PERMIT FOR THE WORKING DRAWINGS IN ACCORDANCE WITH LOCAL DRAWINGS AND STATE REQUIREMENTS. WORKING DRAWINGS SHALL BE SIGNED AND SEALED BY A FLORIDA STATE REGISTERED ENGINEER. 3. MODIFY EXISTING WET -PIPE SPRINKLER SYSTEM AND THE CLEAN AGENT SYSTEM IN ACCORDANCE WITH FLORIDA BUILDING CODE, FLORIDA FIRE PREVENTION CODE, NFPA 2001, NFPA 13, NFPA 14 MANUAL -WET SYSTEM AND LOCAL REQUIREMENTS. ALL PIPING, SPRINKLERS, AND COMPONENTS TO BE UL LISTED AND FM APPROVED FOR FIRE PROTECTION, 4, COORDINATE ROUTING OF PIPING, ETC. WITH PLUMPING AND MECHANICAL (HVAC) ROUTING. PIPING SHALL NOT BE LOCATED MOVE ELECTRICAL PANELS, ETC. PER NFPA 70. 5. ALL TEST/DRAIN LINES (MORE THAN 5 GALLONS) SHALL DISCHARGE DIRECTLY TO THE EXTERIOR WITH THE APPROPRIATE SPLASH PROTECTION. AUXILIARY DRAINS MAY DISCHARGE INTO MECHANICAL ROOM FLOOR DRAINS. DRAINS SHALL BE SIZED IN ACCORDANCE WITH NFPA 13 AND NFPA 14. WORKING DRAWINGS SHALL INDICATE THE LOCATION OF ALL TEST/DRAIN VALVES AND DISCHARGE POINTS 6. ALL PIPES SERVING A SINGLE SPRINKLER ARE 1 INCH MINIMUM. PROVIDE ASTM A 53 SCHEDULE 40 STEEL PIPE FOR WELDED, THREADED, AND GROOVED FITTINGS ONLY. PROVIDE ASTM A135 OR A725 SCHEDULE 10 STEEL PIPE FOR WELDED OR ROLLED - GROOVE FITTINGS ONLY. 7. PROVIDE HANGERS IN ACCORDANCE WITH NFPA 13 AND NFPA 2001. HANGERS TYPES AND LOCATIONS IN THE CONCRETE MEMBERS MUST BE SUBMITTED TO AND APPROVED BY THE STRUCTURAL ENGINEER. A. SEE ELECTRICAL DRAWINGS FOR FIRE ALARM SYSTEM. 9, ALL FLOW AND TAMPER SWITCHES AND ALSO CLEAN AGENT SYSTEM DEVICES TO BE CONNECTED TO THE FIRE ALARM SYSTEM. 10. IF ANY EXISTING PIPING ROUTING CONFLICTS WITH NEW CEILING ELEVATION OR WITH NEW HVAC DUCT ROUTING COORDINATE WITH GENERAL CONTRACTOR THE RELOCATION OF EXISTING SYSTEMS AS REQUIRED. 11. CONTRACTOR PROVIDED INSTALLATION DRAWINGS TO SHOW THE DESIGN AND INSTALLATION OF HANGERS AND STRUCTURAL SUPPORT SYSTEMS. HANGER AND SUPPORT SYSTEMS TO BE DESIGNED AND INSTALLED PER NFPA 13 AND NFPA 2001. 12 UPON FINAL COMPLETION OF THE WORK, OBTAIN CERTIFICATES OF ACCEPTANCE FROM THE CONSTITUTED AUTHORITIES. DELIVER THE CERTIFICATES TO THE ARCHITE=CT FOR TRANSMISSION TO THE OWNER. 13. PROVIDE A FIRE WATCH IN AREAS WHERE SHUTDOWNS OF THE SPRINKLER SYSTEM / CLEAN AGENT SYSTEM IS REQUIRED WHILE WORK IS BEING PERFORMED. THE FIRE WATCH WILL BE REQUIRED IN THE AREAS THAT ARE SHUTDOWN FOR THE LENGTH OF TIME THAT THE SHUTDOWN IS REQUIRED. UPON COMPLETION OF THE AREAS, PROVIDE TEMPORARY FIRE PROTECTION AS REQUIRED UNTIL THE FINAL FINISHES AND CEILING ARE INSTALLED AND CAN BE COORDINATED WITH THE FINAL FIRE PROTECTION LAYOUT. COORDINATE WITH ARCHITECT AND GENERAL CONTRACTOR. COMPLY WITH FOC 419.4.2.10. COORDINATE REQUIREMENT OF FIRE EXTINGUISHERS WITH GENERAL CONTRACTOR. 14. COORDINATE WITH FACILITY AND REQUEST WRITTEN PERMISSION FOR SHUT - DOWNS. 15. SEE ELECTRICAL DRAWINGS FOR FIRE ALARM SYMBOLS LEGEND. CODES 1. FLORIDA BUILDING CODE 2010 EDITION 2. FLORIDA MECHANICAL CODE, 2010 EDITION 3. FLORIDA PLUMBING CODE, 2010 EDITION 4. GUIDELINES FOR DESIGN AND CONSTRUCTION OF HOSPITAL AND HEALTH CARE FACILITIES (GUIDELINES 2010 EDITION) 5. NFPA 101 (2009) LEGEND NOTES OREMOVE EXISTING KIDDE GEMINI II FM 200 CONTROL PANEL FOR RELOCATION. COORDINATE WITH OWNER AND FIRE ALARM CONTRACTOR RELOCATION AND SHUT DOWNS. OREMOVE EXISTING FM -200 SYSTEM ABORT STATION. COORDINATE WITH OWNER AND FIRE ALARM CONTRACTOR DEMOLITION AND SHUT DOWNS. O3 CONTRACTOR TO REFILL EXISTING FM 200 CYLINDER WITH THE ADDITIONAL QUANTITY REQUIRED BY THE VOLUME INCREASE CREATED IN THE ROOM BY THE REMOVAL OF THE EXISTING CEILING. IF NECESSARY REPLACE TANK WITH LARGER UNIT. COORDINATE WITH OWNER AND FIRE ALARM CONTRACTOR RELOCATION AND SHUT DOWNS. 1� - - - - -� ----- i - - - - -� 1 -r� -� EXISTING PIPING AND CLEAN AGENT DISCHARGE NOZZLES INSTALLED UNDER RAISED FLOOR TO REMAIN. CONTRACTOR TO FIN. FL. I 4 ALSO ASSURE THAT THE UNDERGROUND SMOKE DETECTORS ARE PROPERLY FUNCTIONING AND THAT THEY ARE INSTALLED PROPERLY EVEN IF THERE ARE MODIFICATIONS DONE TO THE RAISED FLOOR SYSTEM. COORDINATE WITH GENERAL O CONTRACTOR. CONTRACTOR TO VERIFY INTEGRITY OF THE SYSTEM AND REPAIR IF NECESSARY. ---- - - - - -- REMOVE EXISTING FM -200 SYSTEM SMOKE DETECTOR. COORDINATE WITH OWNER AND FIRE ALARM CONTRACTOR DEMOLITION AND SHUT DOWNS. O REMOVE EXISTING CEILING MOUNTED CLEAN AGENT DISCHARGE NOZZLE COORDINATE WITH OWNER AND FIRE ALARM \7 r W~ am ~� CONTRACTOR DEMOLITION AND SHUT DOWNS. 1 OW SrAIM (ETD) 4lrAFF. aann�af~ P r 2 �� • ! rrAWK wu STAMK w� O REMOVE EXISTING FIM -200 SYSTEM STROBE COORDINATE WITH OWNER AND FIRE ALARM CONTRACTOR DEMOLITION AND X7 SHUT DOWNS. i i O REMOVE EXISTING FM -200 SYSTEM HORN STROBE ABOVE MANUAL PULL STATION. COORDINATE WITH OWNER AND FIRE f I Copt ALARM CONTRACTOR DEMOLITION AND SHUT DOWNS. i O PROVIDE NEW SMOKE DETECTOR INSTALLED AT THE BOTTOM OF THE ROOF STRUCTURE. COORDINATE WITH KIDDE EXTERIOR REPRESENTATIVE TYPE OF DETECTORS TO BE USED. COORDINATE WITH OWNER AND FIRE ALARM CONTRACTOR NEW TYPICAL ROOM ELEVATION SYSTEMS INSTALLATION. OO O 3 N❑ SCALE 10 PROVIDE CLEAN AGENT DISCHARGE NOZZLES ON BOTH SIDES OF THE STORM DRAIN MAIN. FIELD VERIFY. SIZE PIPING ACCORDINGLY. REPLACE EXISTING PIPES IF NECESSARY. COORDINATE WITH OWNER AND FIRE ALARM CONTRACTOR NEW O V SYSTEMS INSTALLATION. INSTALL RELOCATED KIDDE FM 200 CONTROL PANEL, A NEW MANUAL PULL STATION, ABORT STATION, HORN STROBE AND 3 11 BELL NEXT TO DOOR. SEE DETAIL 03 THIS SHEET. RECONNECT TO THE CONTROL PANEL ALL FIRE ALARM DEVICES i MOUNTED BELOW THE RAISED FLOOR. COORDINATE WITH ALL OTHER DISCIPLINES AND OWNER NEW SYSTEMS INSTALLATION. 12 INSTALL NEW STAND ALONE STROBE WAFT. PROVIDE CAUTION SIGN BELOW STROBE COORDINATE WITH OWNER AND FIRE ALARM CONTRACTOR NEW SYSTEMS INSTALLATION. DO NOT INSTAU n, RE ALARM, i i�5► ._... _ 7v fs"Fa-p- Z:'n on i;*��,�rs Tim. _ I - - y I' Le uuu� 'rcr :�.�rrcul to P I; a : e CcYur,Ly Fine D - iru L ezit- i C(XN'Ti���t fO r'S l?±tlrti� PLANS SHALL BE so�e� raX Bt:�:din� l ?ez�nit only! F , - - - - -- Surllrel'1 a,.D FO�ZAIi': OVAi,TO ;p ... U MtAMI DADS COUNTY FIRE DEPtlRTPJiENT h;= 'FORE ANY SYSTEM IS INSTALLED OR REMODELED. Date �7 Z-1 r....EY 0 1 PARTIAL SECOND FLOOR PLAN FIRE PR❑TECTI ❑N DEM ❑LIT ❑N SCALE, 1/4' = 1' -0' NORTH SPRINKLER LEGEND 0E EXISTING PENDENT SPRINKLER TO REMAIN #D DEMOLISH EXISTING SPRINKLER AND ASSOCIATED PIPING i NEW BUILDING STANDARD QUICK RESPONSE PENDENT CONCEALED SPRINKLER. ARM OVER FROM EXISTING 1 1/2' MAIN OR LARGER A NEW 1/ BRANCH LINE REMOVE EXISTING SPRINKLER AND PROVIDE NEW BUILDING STANDARD QUICK • u•. RESPONSE CONCEALED PENDANT SPRINKLER. ARM OVER A 1r SPRINKLER � ! PIPE FROM REMOVED SPRINKLER LOCATION TO NEW SPRINKLER AS •rr r REQUIRED. Project #:413508.000 / • Y r . . / . • x, 2121 Ponce de Leon kulejarn Suite 350 W • • ! Coral Gables, FL 33134 r• phone: 305.569.1692 fax: 305.569.1693 ! • • • ! • InhYgnil GnulYry in�ItNers • Austin . Dallas . Denver . Houston . Kansas City . S`aliamio Nashville . Phoenix . Richmond . Washi4, ton o.C.V. F400007658 i• /! •!� Y / FIRE PROTECTION NOTES i 1. PROVIDE WORKING DRAWINGS FROM THE ENGINEERED CONTRACT DRAWINGS AND SPECIFICATIONS. THE DRAWINGS SHALL FEET ALL OF THE REQUIREMENTS FOR WORKING DRAWINGS PER NFPA 13 AND NFPA 2001. PROVIDE SPRINKLERS / DISCHARGE NOZZLES AND PIPING IN LOCATIONS AND CONFIGURATION INDICATED; HOWEVER, THE CONTRACTOR SHALL COORDINATE THE LOCATION AND ELEVATION OF ALL SPRINKLERS / DISCHARGE NOZZLES AND PIPING WITH ALL BUILDING COMPONENTS AND SYSTEMS. PIPE SIZES SHALL NOT BE LESS THAN INDICATED ON THE DRAWINGS. 2. OBTAIN A PERMIT FOR THE WORKING DRAWINGS IN ACCORDANCE WITH LOCAL DRAWINGS AND STATE REQUIREMENTS. WORKING DRAWINGS SHALL BE SIGNED AND SEALED BY A FLORIDA STATE REGISTERED ENGINEER. 3. MODIFY EXISTING WET -PIPE SPRINKLER SYSTEM AND THE CLEAN AGENT SYSTEM IN ACCORDANCE WITH FLORIDA BUILDING CODE, FLORIDA FIRE PREVENTION CODE, NFPA 2001, NFPA 13, NFPA 14 MANUAL -WET SYSTEM AND LOCAL REQUIREMENTS. ALL PIPING, SPRINKLERS, AND COMPONENTS TO BE UL LISTED AND FM APPROVED FOR FIRE PROTECTION, 4, COORDINATE ROUTING OF PIPING, ETC. WITH PLUMPING AND MECHANICAL (HVAC) ROUTING. PIPING SHALL NOT BE LOCATED MOVE ELECTRICAL PANELS, ETC. PER NFPA 70. 5. ALL TEST/DRAIN LINES (MORE THAN 5 GALLONS) SHALL DISCHARGE DIRECTLY TO THE EXTERIOR WITH THE APPROPRIATE SPLASH PROTECTION. AUXILIARY DRAINS MAY DISCHARGE INTO MECHANICAL ROOM FLOOR DRAINS. DRAINS SHALL BE SIZED IN ACCORDANCE WITH NFPA 13 AND NFPA 14. WORKING DRAWINGS SHALL INDICATE THE LOCATION OF ALL TEST/DRAIN VALVES AND DISCHARGE POINTS 6. ALL PIPES SERVING A SINGLE SPRINKLER ARE 1 INCH MINIMUM. PROVIDE ASTM A 53 SCHEDULE 40 STEEL PIPE FOR WELDED, THREADED, AND GROOVED FITTINGS ONLY. PROVIDE ASTM A135 OR A725 SCHEDULE 10 STEEL PIPE FOR WELDED OR ROLLED - GROOVE FITTINGS ONLY. 7. PROVIDE HANGERS IN ACCORDANCE WITH NFPA 13 AND NFPA 2001. HANGERS TYPES AND LOCATIONS IN THE CONCRETE MEMBERS MUST BE SUBMITTED TO AND APPROVED BY THE STRUCTURAL ENGINEER. A. SEE ELECTRICAL DRAWINGS FOR FIRE ALARM SYSTEM. 9, ALL FLOW AND TAMPER SWITCHES AND ALSO CLEAN AGENT SYSTEM DEVICES TO BE CONNECTED TO THE FIRE ALARM SYSTEM. 10. IF ANY EXISTING PIPING ROUTING CONFLICTS WITH NEW CEILING ELEVATION OR WITH NEW HVAC DUCT ROUTING COORDINATE WITH GENERAL CONTRACTOR THE RELOCATION OF EXISTING SYSTEMS AS REQUIRED. 11. CONTRACTOR PROVIDED INSTALLATION DRAWINGS TO SHOW THE DESIGN AND INSTALLATION OF HANGERS AND STRUCTURAL SUPPORT SYSTEMS. HANGER AND SUPPORT SYSTEMS TO BE DESIGNED AND INSTALLED PER NFPA 13 AND NFPA 2001. 12 UPON FINAL COMPLETION OF THE WORK, OBTAIN CERTIFICATES OF ACCEPTANCE FROM THE CONSTITUTED AUTHORITIES. DELIVER THE CERTIFICATES TO THE ARCHITE=CT FOR TRANSMISSION TO THE OWNER. 13. PROVIDE A FIRE WATCH IN AREAS WHERE SHUTDOWNS OF THE SPRINKLER SYSTEM / CLEAN AGENT SYSTEM IS REQUIRED WHILE WORK IS BEING PERFORMED. THE FIRE WATCH WILL BE REQUIRED IN THE AREAS THAT ARE SHUTDOWN FOR THE LENGTH OF TIME THAT THE SHUTDOWN IS REQUIRED. UPON COMPLETION OF THE AREAS, PROVIDE TEMPORARY FIRE PROTECTION AS REQUIRED UNTIL THE FINAL FINISHES AND CEILING ARE INSTALLED AND CAN BE COORDINATED WITH THE FINAL FIRE PROTECTION LAYOUT. COORDINATE WITH ARCHITECT AND GENERAL CONTRACTOR. COMPLY WITH FOC 419.4.2.10. COORDINATE REQUIREMENT OF FIRE EXTINGUISHERS WITH GENERAL CONTRACTOR. 14. COORDINATE WITH FACILITY AND REQUEST WRITTEN PERMISSION FOR SHUT - DOWNS. 15. SEE ELECTRICAL DRAWINGS FOR FIRE ALARM SYMBOLS LEGEND. CODES 1. FLORIDA BUILDING CODE 2010 EDITION 2. FLORIDA MECHANICAL CODE, 2010 EDITION 3. FLORIDA PLUMBING CODE, 2010 EDITION 4. GUIDELINES FOR DESIGN AND CONSTRUCTION OF HOSPITAL AND HEALTH CARE FACILITIES (GUIDELINES 2010 EDITION) 5. NFPA 101 (2009) LEGEND NOTES OREMOVE EXISTING KIDDE GEMINI II FM 200 CONTROL PANEL FOR RELOCATION. COORDINATE WITH OWNER AND FIRE ALARM CONTRACTOR RELOCATION AND SHUT DOWNS. OREMOVE EXISTING FM -200 SYSTEM ABORT STATION. COORDINATE WITH OWNER AND FIRE ALARM CONTRACTOR DEMOLITION AND SHUT DOWNS. O3 CONTRACTOR TO REFILL EXISTING FM 200 CYLINDER WITH THE ADDITIONAL QUANTITY REQUIRED BY THE VOLUME INCREASE CREATED IN THE ROOM BY THE REMOVAL OF THE EXISTING CEILING. IF NECESSARY REPLACE TANK WITH LARGER UNIT. COORDINATE WITH OWNER AND FIRE ALARM CONTRACTOR RELOCATION AND SHUT DOWNS. 1� - - - - -� ----- i - - - - -� 1 -r� -� EXISTING PIPING AND CLEAN AGENT DISCHARGE NOZZLES INSTALLED UNDER RAISED FLOOR TO REMAIN. CONTRACTOR TO FIN. FL. I 4 ALSO ASSURE THAT THE UNDERGROUND SMOKE DETECTORS ARE PROPERLY FUNCTIONING AND THAT THEY ARE INSTALLED PROPERLY EVEN IF THERE ARE MODIFICATIONS DONE TO THE RAISED FLOOR SYSTEM. COORDINATE WITH GENERAL O CONTRACTOR. CONTRACTOR TO VERIFY INTEGRITY OF THE SYSTEM AND REPAIR IF NECESSARY. ---- - - - - -- REMOVE EXISTING FM -200 SYSTEM SMOKE DETECTOR. COORDINATE WITH OWNER AND FIRE ALARM CONTRACTOR DEMOLITION AND SHUT DOWNS. O REMOVE EXISTING CEILING MOUNTED CLEAN AGENT DISCHARGE NOZZLE COORDINATE WITH OWNER AND FIRE ALARM \7 r W~ am ~� CONTRACTOR DEMOLITION AND SHUT DOWNS. 1 OW SrAIM (ETD) 4lrAFF. aann�af~ P r 2 �� • ! rrAWK wu STAMK w� O REMOVE EXISTING FIM -200 SYSTEM STROBE COORDINATE WITH OWNER AND FIRE ALARM CONTRACTOR DEMOLITION AND X7 SHUT DOWNS. i i O REMOVE EXISTING FM -200 SYSTEM HORN STROBE ABOVE MANUAL PULL STATION. COORDINATE WITH OWNER AND FIRE f I Copt ALARM CONTRACTOR DEMOLITION AND SHUT DOWNS. i O PROVIDE NEW SMOKE DETECTOR INSTALLED AT THE BOTTOM OF THE ROOF STRUCTURE. COORDINATE WITH KIDDE EXTERIOR REPRESENTATIVE TYPE OF DETECTORS TO BE USED. COORDINATE WITH OWNER AND FIRE ALARM CONTRACTOR NEW TYPICAL ROOM ELEVATION SYSTEMS INSTALLATION. OO O 3 N❑ SCALE 10 PROVIDE CLEAN AGENT DISCHARGE NOZZLES ON BOTH SIDES OF THE STORM DRAIN MAIN. FIELD VERIFY. SIZE PIPING ACCORDINGLY. REPLACE EXISTING PIPES IF NECESSARY. COORDINATE WITH OWNER AND FIRE ALARM CONTRACTOR NEW O V SYSTEMS INSTALLATION. INSTALL RELOCATED KIDDE FM 200 CONTROL PANEL, A NEW MANUAL PULL STATION, ABORT STATION, HORN STROBE AND 3 11 BELL NEXT TO DOOR. SEE DETAIL 03 THIS SHEET. RECONNECT TO THE CONTROL PANEL ALL FIRE ALARM DEVICES i MOUNTED BELOW THE RAISED FLOOR. COORDINATE WITH ALL OTHER DISCIPLINES AND OWNER NEW SYSTEMS INSTALLATION. 12 INSTALL NEW STAND ALONE STROBE WAFT. PROVIDE CAUTION SIGN BELOW STROBE COORDINATE WITH OWNER AND FIRE ALARM CONTRACTOR NEW SYSTEMS INSTALLATION. DO NOT INSTAU n, RE ALARM, i i�5► ._... _ 7v fs"Fa-p- Z:'n on i;*��,�rs Tim. _ I - - y I' Le uuu� 'rcr :�.�rrcul to P I; a : e CcYur,Ly Fine D - iru L ezit- i C(XN'Ti���t fO r'S l?±tlrti� PLANS SHALL BE so�e� raX Bt:�:din� l ?ez�nit only! F , - - - - -- Surllrel'1 a,.D FO�ZAIi': OVAi,TO ;p ... U MtAMI DADS COUNTY FIRE DEPtlRTPJiENT h;= 'FORE ANY SYSTEM IS INSTALLED OR REMODELED. Date �7 Z-1 r....EY 0 1 PARTIAL SECOND FLOOR PLAN FIRE PR❑TECTI ❑N DEM ❑LIT ❑N SCALE, 1/4' = 1' -0' NORTH Z� 3 O_d < "a 00 z ,�.• gJ4 /� ~ LLId LLL1 �x <0 N P=4 0 P=q �1 = h 1�1 � O Q V .PEN z U 94 Iti•r O c� Q Z z O O VZ� Iw < LLJ O �0 Oh0L wwi AHCA STAGE 1H 12/13/13 MAVDb CORD CNKCKC CCRD DAIL 12 -13 -13 go Alb svelf . Vilif _o- a L ao iARNIC IC � �Ita 4 ;t774. Sheet Na F2.02 JOB • h 6 C • M L� • r u u u u ♦ • • • u•. r • � ! �` � • •rr r ♦•Y .rN• ! r r V • A** *90' Z� 3 O_d < "a 00 z ,�.• gJ4 /� ~ LLId LLL1 �x <0 N P=4 0 P=q �1 = h 1�1 � O Q V .PEN z U 94 Iti•r O c� Q Z z O O VZ� Iw < LLJ O �0 Oh0L wwi AHCA STAGE 1H 12/13/13 MAVDb CORD CNKCKC CCRD DAIL 12 -13 -13 go Alb svelf . Vilif _o- a L ao iARNIC IC � �Ita 4 ;t774. Sheet Na F2.02 JOB • h