Loading...
14-523-0081. THIS DRAWING IS ONLY TO ASSIST IN SHOWING THE SCOPE OF DEMOLITION WORK AND IS NOT INTENDED TO INDICATE ALL DEMOLITION. CONTRACTOR SHALL REMOVE ALL EXISTING ITEMS AS REQUIRED TO COMPLETE THE JOB. 2. NOT ALL ITEMS TO BE DEMOLISHED ARE SHOWN ON THE PLAN. CONTRACTOR SHALL BE RESPONSIBLE FOR PERFORMING A WALK -THRU OF THE PROJECT PRIOR TO SUBMITTING A BID TO THE OWNER FOR IDENTIFYING POSSIBLE CRITICAL ITEMS, NOT OR INCORRECTLY ADDRESSED, WHICH REQUIRE REMOVAL/ RELOCATION. 3. PROVIDE SAFETY FEATURES DURING WORK AS CALLED FOR IN SPECIFICATIONS, APPLICABLE CODES, RULES AND REGULATIONS HAVING JURISDICTION OF THE PROJECT. 4. CUT, REMOVE, PATCH, ALTER AND REFINISH EXISTING CONSTRUCTION AS REQUIRED TO LEAVE WORK COMPLETE AND IN SATISFACTORY MANNER. 5. CONTRACTOR IS TO PROTECT ALL UNDER - GROUND OR OTHER CONCEALED UTILITIES HE IS TO INSPECT CEILING AND CHASES TO ASSURE PROPER IDENTIFICATION OF UTILITIES. MECHANICAL AND /OR ELECTRICAL CONTRACTOR ARE TO CAP THEM AS REQUIRED. 6, OPENINGS LEFT THROUGH RATED AND SMOKE PARTITIONS DUE TO REMOVAL OF DUCTWORK CONDUIT SHALL BE CLOSED (BOTH SIDES) AS PER A.H.C.A. PENETRATION DETAILS. "L REMOVE ALL EXISTING ACOUSTICAL TILE CEILING AND SUSPENDED SYSTEMS IN THE RENOVATION AREA AS REQUIRED FOR INSTALLATION OF WORK TO BE DONE. COORDINATE REMOVAL WITH ELECTRICAL CONTRACTOR REGARDING EXISTING LIGHTING FIXTURES ETC. REPLACE CEILING ACCORDINGLY AFTER COMPLETION OF WORK. 8. CONTRACTOR IS TO WET SAW -CUT ALL OPENINGS IN CONCRETE BLOCK WALLS IF REQUIRED. CONTRACTOR SHALL NOT DEMOLISH OPENINGS WITH SLEDGE HAMMER UNTIL OUTLINES HAVE BEEN CUT. GENERAL. DEMOLITION NOTES g. RENOVATION WORK MAY ENTAIL INTERVENTIONS IN AREAS OUTSIDE OF THE IMMEDIATE SCOPE OF WORK, INCLUDING WORK ABOVE AND /OR BELOW THE FLOOR LEVEL WITHIN THE SCOPE. IT MAY REQUIRE WORK INVOLVING REMOTE PLUMBING, COMMUNICATIONS). ANY WORK IN AREAS OUTSIDE OF THE IMMEDIATE SCOPE OF WORK SHALL BE ALL - INCLUSIVE, PROVIDING ALL STRUCTURES, UTILITIES, FINISHES AND EQUIPMENT REQUIRED TO RESTORE THE AREA TO FULLY OPERATIONAL CONDITIONS, TO FULLY COMPLYING RATING INTEGRITY, AND TO MEET OWNER'S APPROVAL ALL WORK AS DESCRIBED IN THIS NOTE IS TO BE PART OF THE BASE CONTRACT PRICE, OR CONTRACT CONTINGENCY ALLOWANCE FOR SUCH WORK 10. CONTRACTOR IS TO COORDINATE DEMOLITION WORK WITH ADMINISTRATION AND IS TO GIVE SUFFICIENT ADVANCE NOTICE OF THE BEGINNING OF WORK IN EACH EXISTING FLOOR TO (12 HOUR MINIMUM). SHUT DOWN REQUESTS BY THE CONTRACTOR SHALL BE PROCESSED BY SMH'S PROJECT MANAGER. I1. CONTRACTOR SHALL VERIFY EXACT LOCATION OF EXISTING CONCRETE C01,UMN5 IN AREAS WHERE WALLS ARE BEING REMOVED AND INFORM ARCHITECT OF ANY CONFLICTS BEFORE ANY WALLS ARE REMOVED SO THAT A/E CAN INSPECT THEM FOR CLARIFICATION PRIOR TO PROCEEDING WITH WORK. 12. PATCH AND REPAIR ALL EXISTING SURFACES DAMAGED BY DEMOLITION AND /OR INSTALLATION OF NEW ELECTRICAL CONDUITS, GAS PIPING, ETC. AS REQUIRED TO MATCH ADJACENT SURFACES AND /OR AS REQUIRED FOR NEW SCHEDULED FINISHES. 13. DEMOLITION IS DENOTED BY BROKEN LINES. 14. FOR REMOVAL OF FIXTURES AND EQUIPMENT, SEE ARCHITECTURAL, PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS. 15. PREPARE EXISTING CONCRETE SLAB A5 REQUIRED BY GRINDING, LEVELING WITH ARDEX LEVELER AS PER MANUFACTURER'S SPECIFICATIONS. MATCH EXISTING SLAB ELEVATION AS REQUIRED TO RECEIVE NEW SCHEDULED FLOORING MATERIAL. Iro. VERIFY WITH CIVIL, PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS ITEMS TO BE REMOVED /RELOCATED IN CASE OF CONFLICT. 11 DESTINATION OF ALL EXISTING EQUIPMENT, PLUMBING FIXTURES, DOORS AND FRAMES, ETC. TO BE REMOVED SHALL BE COORDINATED WITH THE OWNER, IS. CONTRACTOR TO SURVEY PROJECT AREA PRIOR TO COMMENCEMENT OF WORK. NOTE AND REPAIR ANY DAMAGE TO AREAS WHERE WORK 15 GOING TO BE PERFORMED. NOTIFY OWNER AND ARCHITECT WITH A LIST OF WORK PRIOR TO CONTRACT. 19, THIS SET OF DRAWINGS 15 TO BE USED AS A UNIT, CONTRACTOR 15 RESPONSIBLE FOR ALL DISCIPLINES AND SHOULD INCLUDE EVERYTHING THAT 15 NEEDED FOR MAKING ALL SYSTEMS WORK. EXAMPLE: IF A SINK IS SHOWN IN THE ARCHITECTURAL PLANS, IT 15 ASSUMED THAT THE GENERAL CONTRACTOR IS PROVIDING EVERYTHING NEEDED, A/E WILL PROVIDE THEM WITH THE UNDERSTANDING THAT THERE WILL BE NO ADDITIONAL COST TO OWNER 20. ALL ITEMS THAT ARE SCHEDULED TO BE REMOVED TEMPORARILY AND RE- INSTALLED SHALL BE STORED IN A DUST -FREE, CLEAN AND SAFE LOCATION BY THE CONTRACTOR IN COORDINATION WITH THE OWNER IF ITEMS ARE DAMAGED IN ANY WAY, THE CONTRACTOR SHALL REPLACE THEM TO MATCH EXISTING AT NO ADDITIONAL C05T TO THE OWNER. 21. PRIOR TO THE REMOVAL OF ANY EXISTING SECURITY DEVICE AND EXISTING WIRING, THE CONTRACTOR 15 TO COORDINATE THIS IN ADVANCE WITH THE 'SOUTH MIAMI HOSPITAL PROJECT MANAGER. FAF,TIAL_ 5ECOND FLOOf' DEMOLITION FLAN SC:ALF: 1/4' = 1' -0' NOTE: 0 ALL AS SHOWN 15 EXISTING TO REMAIN UNLESS OTHERWISE NOTED (U.O.N) • SEE M.E.P. DRAWINGS TO CONFIRM REQUIRED SCOPE OF WORK. 0 FOR REQUIRED PRESSURIZATION BETWEEN CONSTRUCTION AREA AND ADJACENT AREA OUT OF SCOPE OF WORK SEE MECHANICAL DRAWINGS. • CONTRACTOR 15 RESPONSIBLE FOR MAINTAINING OR IMMEDIATELY RESTORING FIRE / SMOKE 2 RATED CONSTRUCTION / SAFING. lcfR ANOTE&: FRO CON IN DUOUS ALL AROUND AND PROVIDE EZ DUCT TAPE PPER ENTRANCE A5 REQUIRED. PROVIDE 'DUST -PROOF BARRIER' VIZQUEEN ((o MIL. POLY) SEALED WITH DUCT TAPE CONTINUOUS ALL AROUND r•.�; •y" DEMOLITION FLAN L`EGE -NI-D w y r U •rr rww r D r WALL OR PARTITION (SEE PA TITION TYPES! ONE HOUR EIRE /SMOKk; m i ■ i ww w i w WALL OR PARTITION • • • (SEE PARTITION TYPEi)• •• TWO HOUR FIRE /SMOKE RATED WALL OR PARTITION (SEE I=ARTTION TYP EJ, . • r.. EXISTING REINFORC!5P ,�ONC. • a COLUMN OR CONCRcTE MALL • ',wocr` (SEE FLOOR LANS • ••e ww EXISTING WALL OR PARTITION TO REMAIN — — — -- --- EX15TING WALL OR — — i PARTITION TO 15E REMOVED WALL OR PARTITION WITH .._ EXISTING DOOR TO BE REMOVED DEMOLITION SYMBOL (SEE DEMOLITION LEGEND) OUT OF SCOPE OF WORK DEMOLITION NOTEe O REMOVE EXISTING DOOR AND FRAME - RETURN TO OWNER INCLUDING HARDWARE. O EXISTING FINISHES ON WALLS SHALL BE REMOVED AND PREPARED TO RECEIVE NEW PAINT FINISH. 0 ALL EXISTING ACCESS RAISED FLOOR METAL FRAMING AND TILES SHALL BE REMOVED. (9 REMOVE EXISTING V.G.T. FLOORING UNDER EXISTING RAISED ACCESS FLOOR SYSTEM. ASBESTOS ABATEMENT WORK SHALL BE COORDINATED WITH CONTRACTOR AND OWNER. O ALL EXISTING= SUSPENDED ACOUSTICAL CEILING SYSTEM SHALL BE REMOVED INCLUDING LIGHTING FIXTURES. O REMOVE PLYWOOD ENCL05URE5 FOR EXISTING FIRE SUPPRESSION TANK AND SUPPLY LINE. V FOR SCOPE OF WORK RELATING TO THE EXISTING FIRE SUPPRESSION SYSTEM SEE M.E.P DRAWINGS, O REMOVE ALL EXISTING FURNISHINGS (LOCKERS, WALL CLOCK, ETC.) AND RETURN TO OWNER (U.ON). O EXISTING CABINETS TO BE REMOVED AND RETURNED TO OWNER O EXISTING WALL MOUNTED FIRE EXTINGUISHER. 10 REMOVE EXISTING WINDOW - PATCH OPENING TO MATCH EXISTING. 11 PROVIDE NEW ROUGH OPENING FOR NEW PAIR OF DOORS. SIZE SHALL BE: (1) 3' -0' X "I' -0' X I ;' AND (1) 2' -4' X 1' -0' X 1 4' (BOTTOM OF NEW DOOR SHALL BE FLUSH WITH TOP OF EXISTING RAISED FLOOR). 12 EXISTING 1' d BLAGK PIPE FOR FIRE SUPPRESSION SYSTEM - SEE M.E.P. DRAWINGS FOR SGOPE OF WORK 13 REMOVE EXISTING PRE -FAB MODULAR OFFICE FURNITURE INCLUDING LOW HEIGHT PARTITION AND WALL MOUNTED CABINETS (BY OWNER). 14 EXISTING AREA TO BE REMODELED FOR THE INSTALLATION OF A NEW ACCE55 RAMP, 15 EXISTING AREA AS SHOWN TO REMAIN U_ON. VERIFY W/ OWNER ITEMS TO BE REMOVED. 16 EXISTING VCT FLOORING TO REMAIN U.O.N. I`I SEE M.E.P. DRAWING=S FOR ADDITIONAL DEMOLITION WORK. 18 SEE SHEET A -IA FOR REQUIRED DEMOLITION WORK ON EXISTING REFLECTED CEILING PLAN. I� EXISTING ELECTRICAL PANEL TO BE REMOVED - SEE ELECTRICAL DRAWINGS. 20 REMOVE EXISTING PARTITION AS SHOWN - CONTRACTOR TO VERIFY IF ANY SERVICE LINES ARE INSIDE THIS CHASE, IF ANY ARE FOUND, NOTIFY ARCHITECT AT ONCE AND PUT DEMOLITION WORK ON HOLD. 21 SEE ELECTRICAL DRAWINGS TO VERIFY THE REMOVAL OF DESIGNATED RACKS, 5ERVER5, ETC. AND PHASING. 22 REMOVE EXISTING A/C UNITS - SEE MEP DRAWINGS FOR DEMOLITION NOTES. MODIFICATIONS ONLY INTERIOR (ANY EXTERIOR MODIFICATION MAY REQUIRF, A BOARD APPEARANCE) ®I Reuiall�n «:� . b4- �3 -14� r r • • wwr • Q• • r • r • oa 4a" 00 wx �c �c �w J.-W w w� ux H 40 o0 0 U �V 0 I Z 0 La] 0 La < zW Q 0 CIA 0 cw/iz< O W � � H z a w A: AHCA STAGE III W13/13 In>RAVM R.G. CIIECK,ECh LEN. DATL 12 -13 -13 SCALF- AS SHOWN Sheet No. A -1 OF 11 I JOB 0 201316 I