14-523-004Affiliate of Baptist Health Systems of South Flori
GENERAL NOTES
I.- CONTRACTOR IS BEING PROVIDED WITH COMPLETE SETS OF
DOCUMENTS. CONTRACTOR IS RESPONSIBLE FOR PROVIDING
SUBCONTRACTORS WITH COMPLETE SETS OF DRAWINGS. INTENT
IS FOR ALL SYSTEMS AND EQUIPMENT TO BE PROVIDED WITH
UTILITY CONNECTIONS AS REQUIRED FOR OPERATION.
EXAMPLE = IF A SINK IS SHOWN IN THE ARCHITECTURAL PLANS,
THE PLUMBING PLANS DO NOT SHOW A WATER OR DRAWINGS
CONNECTION THE ENGINEER WILL PROVIDE THE DESIGN DETAILS
IN ACCORDANCE WITH THE DESIGN CRITERIA FOR THE REST OF
THE INSTALLATIONS, CONTRACTOR IS RESPONSIBLE FOR PRO-
VIDING THE CONNECTION AT NO ADDITIONAL COST TO THE OW-
NER.
2.- CONTRACTOR IS RESPONSIBLE FOR VISITING THE SITE DURING
THE BIDDING PERIOD AND VERIFY THAT THE CONDITION ARE
AS DESCRIBED IN THE DOCUMENTS. DISCREPANCIES ARE TO
BE NOTED IN WRITING, AND NOTIFY ARCHITECT / ENGINEERS.
CONTRACTOR ACCEPTS CONDITIONS AS THEY ARE ON THE SITE,
AND MUST PROVIDE SYSTEMS AND WORK AS DESCRIBED IN THE
CONTRACT DOCUMENTS AT NO ADDITIONAL COST TO THE OWNER.
3.- DIMENSIONS PROVIDED ARE NOMINAL NOT ACTUAL, THEY TAKE
AS A BASIS EXISTING WALLS. IF DISCREPANCIES ARE FOUND,
NOTIFY ARCHITECT IMMEDIATELY FOR COORDINATION. IF CON-
TRACTOR PROCEEDS, HE DOES SO AT HIS OWN RISK AND IS
RESPONSIBLE FOR ALL EXPENSES INCURRED IF AT THE DISCRE
TION OF THE OWNER OR THE ARCHITECT THE WORK HAS TO BE
RE -DONE.
4.- SHUTDOWN OF UTILITIES: IF A SHUTDOWN OR ANY TYPE OF INTER-
FERENCE WITH EXISTING SYSTEMS IS ANTICIPATED THE CONTRAC
TOR MUST NOTIFY THE OWNER 72 HOURS IN ADVANCE AND OBTA-
IN APPROVAL IN WRITING PRIOR TO PROCEEDING.
5.- CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS AND
USE ALL APPROPRIATE CONSTRUCTION METHODS / TECHNIQUES
TO PROTECT EXISTING UTILITIES AND OTHER PROPERTY NOT
NOTED FOR REMOVAL. CONTRACTOR SHALL BE RESPONSIBLE
FOR ANY DAMAGES INCURRED DURING CONSTRUCTION AND
SHALL REPAIR ANY DAMAGES AT NO EXPENSE TO THE OWNER.
6.- IF THERE IS A DISCREPANCY BETWEEN THE DRAWINGS AND THE
SPECIFICATIONS, THE CONTRACTOR IS TO OBTAIN CLARIFICATION
DURING THE BIDDING PERIOD. IF THE DISCREPANCY COMES UP
DURING THE CONSTRUCTION,IT IS ASSUMED THE CONTRACTOR BID
THE MOST EXPENSIVE WAY AND WILL DO THE WORK AS PER THE
DIRECTION OF THE OWNER /ARCHITECT AT NO ADDITIONAL COST
TO THE OWNER,
7.- ABBREVIATIONS THROUGHOUT THE PLANS ARE THOSE IN COM-
MON USE ARCHITECT WILL DEFINE INTENT OF ANY IN QUESTION.
8.- THE CONTRACTOR SHALL PROVIDE ALL NECESSARY TEMPORARY
BARRIERS, LIGHTING, COVERINGS, FIRE PREVENTION AND OTHER
EQUIPMENT TO PROTECT THE SAFETY OF ALL PERSONS AND THE
PROPERTY THROUGHOUT THE ENTIRE PERIOD OF THE CONSTRUC _
TION CONTRACT.
9.- THE CONTRACTOR SHALL VERIFY SIZES AND LOCATIONS OF ALL
OPENINGS FOR MECHANICAL, ELECTRICAL AND PLUMBING EQUIPMENT
WITH SUBCONTRACTORS, AS WELL AS SHOP DRAWINGS AS APPROVED
BY ARCHITECT, BEFORE PROCEEDING WITH THE WORK.
IO.- ALL ITEMS USED IN CONSTRUCTION, BUT NOT SPECIFICALLY MENTIONED
HEREIN, SHALL CONFORM TO ALL LOCAL CODES AND STATE ORDINANCES
AS TO APPLICATION AND USE.
II.- PROVIDE ELECTRIC INSULATION BETWEEN ALL DISSIMILAR METAL
AND ALSO BETWEEN CEMENT AND METAL.
12:- THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL
PERMI'T'S TO COMPLETE THE PROJECT.
13.- CONTRACTOR TO REVIEW ALL EXISTING BUILDING SYSTEMS AS TO THEIR
COMPLIANCE WITH ALL LOCAL AGENCY REQUIREMENTS AND BRING ANY
NON - CONFORMING ITEMS TO ARCHITECTS AND ENGINEER'S ATTENTION.
14.- GENERAL CONTRACTOR IS TO PROTECT EXISTING ADJACENT AREAS TO
WHERE WORK IS TO BE PERFORMED. ANY EXISTING MILLWORK,
EQUIPMENT DAMAGED DUE TO WORK PERFORMED SHALL BE REPAIRED/
REPLACED TO MATCH EXISTING (TYPICAL UNLESS OTHERWISE NOTED).
15.- DRAWINGS ARE SCHEMATIC SHOWING RELATIVE LOCATIONS AND
CONNECTIONS AND SHALL NOT BE SCALED AT ANY TIME.
16.- ALL WOOD BLOCKING WITHIN BUILDING STRUCTURE, SHALL BE FIRE -
RETARDANT TREATED AS PER SPECIFICATIONS.
IT- GENERAL CONTRACTOR SHALL INSPECT ALL EXISTING RATED WALLS /
PARTITIONS WITHIN SCOPE OF WORK AREA. CONTRACTOR SHALL UPGRADE
EXISTING PARTITIONS AS REQUIRED TO MAINTAIN THE INTEGRITY
OF THE DESIGNATED RATING.
18.- ELEVATION AND LEVELS:
A. ALL NUMERICAL ELEVATIONS ARE TO TOP OF CONCRETE SLAB.
UNLESS NOTED OTHERWISE.
19.- ALL INTERIOR GYPSUM WALL BOARD IS 5/8" TYPE X G.W.B. ON METAL
STUDS OR FURRING CHANNELS UNLESS NOTED OTHERWISE, SIZES AS
DIMENSIONED ON FLOOR PLANS. SEE NOTES 9 FOR LOCATION OF
WATER RESISTANT G.W.B.
20,- PROVIDE WATER RESISTANT TYPE X G.W.B, IN ALL TOILETS.
AND JANITOR'S CLOSETS.
21.- BEFORE PATCHING ANY FIRE - RATED C.M.U. PARTITION. FILL ANY
EXPOSED CELLS SOLID WITH GROUT.
22.- PROVIDE FINISH WALL UNDER AND BEHIND ALL EQUIPMENT AND CASEWORK.
23.- LOCATION AND SIZE OF CEILING AND WALL ACCESS PANELS SHALL BE
DETERMINED BY THE POSITION OF VALVES AND OTHER MECHANICAL AND
ELECTRICAL ITEMS WHICH REQUIRE ACCESS. THE CONTRACTOR SHALL
COORDINATE WITH ALL TRADES. THE ARCHITECT SHALL REVIEW AND
APPROVE ALL FINAL LOCATION OF ACCESS PANELS PRIOR TO
INSTALLATION.
24.- THERE SHALL BE NO BACK - TO BACK ELECTRICAL TELEPHONE
OR OTHER OUTLETS.
25,- ALL VERTICAL PIPING AND COLUMNS, EXPOSED IN ROOMS SHALL BE
FURRED WITH METAL STUDS AND DRY WALL AND FINISHED TO MATCH
ADJACENT WALLS, UNLESS NOTED OTHERWISE, EXCEPTIONS:
A. ELECTRIC CLOSETS C, MECHANICAL ROOMS
B. TELEPHONE CLOSETS D. STAIRS
26.° WHERE HVAC OR OTHER MECHANICAL, ELECTRICAL AND PLUMBING ITEMS
PENETRATE PARTITIONS, STUDS SHALL BE BRACED AND FRAMED TO
STRUCTURE AS REQUIRED TO PROVIDE ADEQUATE SUPPORTS. ALL
PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED TO PROVIDE
FIRE, SMOKE AND / OR ACOUSTICAL ISOLATION OF SPACES WITH
APPROPRIATE FIRE S.T.0 MATERIAL.
27.- SEE INTERIOR ELEVATIONS FOR FINISHES AND FINISH DETAILS FOR INTERIOR
SPACES. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR
ACOUSTICAL TILE: FINISH.
28.- SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATION OF
CEILING MOUNTED MECHANICAL, ELECTRICAL FIXTURES.
29.- STAGGER JOINTS VERTICALLY AND HORIZONTALLY IN ALL G.W,B. PARTITIONS
EA. SIDE OF PARTITION, JOINTS STAGGERED MINIMUM 2' -0".
UNLESS OTHERWISE NOTED.
30. CONTRACTOR SHALL CONFIRM THAT ALL EXISTING EXPOSED
STEEL COMPLIES WITH N.F.P.A FIRE PROTECTION REQUIRE-
MENTS. CONT12ACTORSHALL PROVIDE ALL NECESSARY INSULA-
TION /FIRE PROTECTIVE COATINGS.
31. CONTRACTOR TO SUBMIT ALL SHOP DRAWING TO ARCHITECT AND
THE BUILDING DEPARTMENT FOR APPROVAL. (ELEVATOR, TRUSSES,
WINDOWS, ETC.)
32, CONTRACTOR REQUIRED TO PULL SEPARATE DEMOLITION PERMIT.
S C> " Ir 11-4 MIAMI
6200 SW 73RD ST
TEL: (786) 662 - 4659
HOSPITAL
MIAMI ,FL. 33145
FAX: (305) 662 - 4653
AHCA STAGE III - PROJECT ID #: 23/100154 -203 -1
DECEMBER 13, 2013
(INTERIOR REMODELING ONLY)
0 A 0
FMKI I W I
* t a r c h I
e c t s
P2121 Ponce de Leon Blvd., Suite 350
Coral Gables, FL 33134 FLORIDA LICENSE #AA0002689
Professional Consulting Engineers phone: 305.569.1692
fax: 305.569.1693 2100 PONCE DE LEON BLVD. SUITE 1170, CORAL GABLES, FL 33134
Dallas • Houston • Nashville . Miami • Richmond
ccrd project number: Tel: (305)265 -7177 Fix: (305)22 ®8435
EB00007658 LUIS E. NAYA, A.I.A Fl, AR0008063
PROJECT NUMBER: 201316
INDEX OF DRAWINGS
CS -1 COVER SHEET.
C ITY M LIFE SAFETY PLUMBING
LS-1 PARTIAL SECOND FLOOR LIFE SAFE'T'Y PLAN AND ICRA DIAGRAM. P2.02 PARTIAL 2ND FLOOR PLAN.
LS -2 PARTIAL FIRST FLOOR LIFE SAFETY PLAN.
ARCHITECTURAL
PROTECTION
4 t--- TTo� &(� ; r a ARC F2.02 FAItTIAL 2ND FLOOR NEYF PORK PLAN.
A--1 PARTIAL 2ND FLOOR DEMOLITION PLAN, LEGEND AND DETAILS.
Yi r LS!-
A -1A PARTIAL 2ND FLOOR DEMOLITION REFLECTED CEILING PLAN.
A -2 PARTIAL 2ND FLOOR PLAN, LEGEND, NOTES AND DETAILS. ELECTRICAL
A -3 EQUIPMENT AND REFLECTED CEILING PLAN, LEGEND AND NOTES.
/ A -4 PARTIAL DEMOLITION ROOF PLAN, NOTES, AND DETAILS.
s 5a < EO.00 GENERAL INFORMATION.
FrM �, w,,•d A -4A PARTIAL ROOF PLAN - NEW WORK, NOTES AND DETAILS
r r A--5 PARTITION TYPES, NOTES AND DETAILS. E0.01 GENERAL INFORMATION.
E AILS. ED1.02 PARTIAL 2ND FLOOR DEMOLITION PLAN.
#`u pl -' ' A -6 INTERIOR ELEVATIONS, DOOR SCHEDULE, NOTES AND D T
a
A -7 PENETRATION AND FIRE RATING DETAILS. E2.02 PARTIAL 2ND FLOOR NEW WORK PLAN.
-��, L; • �, ��{ A -8 PENETRATIONS AND FIRE RATING DETAILS.
�tn E3.02 PARTIAL 2ND FLOOR NEW WORK - SYSTEMS.
o,s n�,tmr t.� A -9 PENETRATIONS AND FIRE RATING DETAILS. E6.01 PARTIAL ELECTRICAL ONE -LINE DIAGRAM.
E6.02 ELECTRICAL STUDIES.
rr----II^^T E7.01 ELECTRICAL DETAILS.
..GlJTHhL` AH45PIrAL �1 }
s�oasw�3sYr��r I j
s t E8.01 ELECTRICAL SCHEDULES.
f
_ MECHANICAL E7.02 ELECTRICAL DETAILS.
T ` va . E8.02 ELECTRICAL SCHEDULES.
M0.00 GENERAL NOTES, SCHEDULES AND DETAILS.
CMD1.02 PARTIAL SECOND FLOOR DEMOLITION PLAN - COMMUNICATIONS.
MD 1.02 PART 2ND FLOOR DEMOLITION PLAN. 1,02 PARTIAL SECOND FLOOR PLAN COMMUNICATIONS.
�' CM
M2.02 PARTIAL 2ND FLOOR NE W WORK PLAN.
M3.02 PARTIAL 2ND FLOOR NEW WORK PLAN.
M7.01 MECHANICAL DETAILS.
M -ICRA PARTIAL SECOND FLOOR ICRA PLAN.
w-iv 4t..�a.✓._+-F rt...o r. r.�rc.uWra'a. ...t�:air.satr..., ":. r�t"'�,h: �„ .. .'�.tGs ..�'
AREA MAP
INTERIOR MODIFICATIONS ONLY
(ANY E)CCE A BOARD A'PEARAN CF)
Fi�QUriZE
BUILDING INFORMATION REVI I�1
A
ORIGINAL BUILDING DESCRIPTION
rh Sr
BUILDING
JURISDICTION DADE, COUNTY
m 1 R' �drM
PRIMARY USE CLASS :HEALTHCARE
{" 3r �gr< CONSTRUCTION TYPE (NFPA) : TYPE 1 (3,3,2)
s -- CONSTRUCTION TYPE : TYPE 1, FLORIDA BUILDING CODE
s�uTrtMainiuosPrr�L su.= NUMBER OF STORIES : 7 STORIES
630054V r357rtEET
NEW PROJECT DESCRIPTION J/�\
sw z r� sr PROJECT AREA: : TOTAL: 860 SQ.FT.
p SPRINKLED : TOTAL: FULLY SPRINKLED
3 zr
t
APPLICABLE CODES
�/� "' • FLORIDA BUILDING CODE 2007 EDITION WITH 2000 REVISION.
�e b Fr' FLORIDA FIRE PREVENTION CODE 2007 EDITION. f
NFPA 101 LIFE SAFETY CODE; 2006 EDITION L�
(CHAPTER 18 NEW HEALTHCARE).
ALA CAREEFACILITIESSI2010 DIT EDITION.
OF f\
° U
ABBREVIAT10
u u U U V V
V U V
��/1���J�� (/��� }1 jV ,(`,], (/ J���/��y
A 'mac• iTrzc. • u ■ I/� io e:
V V V U U U
U V V u V V ��/ }��U V V V
U�l , DRAUNG V u V
JANITOR
JB
L
JCT
d AND
JSK
JANITORS SINK
UJ uv
L ANGLE
L Iv
U
LENGTH �L
LAMAMINAT
G CENTERING
LAv a
AL`ATwR r � . u u. o u
O DIAMETER
LB
POUNDS
" POUND OR NUMBELee?
LBS /HR
POUNDS PER HOUR
A
LD
LINEAR DIFFUSER
LP
LOW POINT
A/C
AIR CONDITIONING
LT
LIGHT
ACI
AMERICAN CONCRETE INSTITUTE
ACP
A55E5TOS CEMENT PIPE
ACSC
ASPHALTIC CONCRETE SURFACE COURSE
ACU
AIR CONDITIONING UNIT
ACT
ACOU5TICAL CEILING TILE
MATL
MATERIAL
AD
AREA DRAIN
MAX
MC
MAXIMUM
MEDICINE CABINET
ADJ
ADJUSTABLE
MECN
MECHANICAL
A/E
ARGWITECT /ENGINEER
MEMB
MEMBRANE
AF
ACCESS FLOORING
MFR
MANUFACTURER
AFF
ABOVE FIN15HED FLOOR
MIN
MINIMUM
AGGR
AGGREGATE
1-1150
MISCELANEOUS
AHU
AIR HANDLING UNIT
MO
MASONRY OPENING
ALT
ALTERNATE
AL
ALUMINUM
MTV
MOUNTED
ANN
ANNUNCIATOR
MTL
METAL
AN51
AMERICAN NATIONAL STANDARDS INSTITUTE
MUL
MULLION
ANT
ANTENNA
MULT
MULTIPLE
AP
ACCE55 PANEL
APL
ACCESS PLENUM
N
APROX
APPROXIMATE
ARCH
ARCHITECTURAL
A56
ASBESTOS
N
NORTH
ASPH
ASPHALT
NEC
NATIONAL ELECTRIC CODE
ASTM
AMERICAN SOCIETY OF TESTING E MATERIALS
NIC
NOT IN CONTRACT
NO
NUMBER
ROM
NOMINAL
NPL
NAME PLATE
NTS
NOT TO SCALE
BAT
BATTERY
BD
BOARD
BITUM
BITUMINOUS
O
BLDG
BUILDING
BLKG
BLOCKING
BM
BEAM
OA
OVERALL
BOT
BOTTOM
OB5
OBSCURE
OC
ON CENTER
OD
OUTSIDE DIAMETER DIM)
OFS
OVERFLOW SCUPPER
OPP
OPPOSITE
GAB
CABINET
CB
CATCH BASIN
ID
CEM
CEMENT
CER
CERAMIC
CFM
CUBIC FEET PER MINUTE
PC
PRECAST CONCRETE
GG
CORNER GUARD
PJ
PIPE JOINT
CHP
CRICKET HIGH POINT
PL
PLASTIC
CI
CAST IRON
P LAM
PLASTIC LAMINATE
GIG
CAST IRON COVER
PLA5
PLASTER
CIP
CAST IRON PIPE
PLYWD
PLYWOOD
CJ
CONTROL JOINT
PNT
PAINT
CLG
CEILING
PT
POINT OR PATIENT
CLGD
CEILING DIFFUSER
PTp
PAPER TOWEL DISPENGER
CL KG
CAULKING
PTN
PARTITION
GLO
CLOSET
PTR
PAPER TOWEL RECEPTACLE
CLP
CRICKET LOW POINT
CLR
CLOSER
Q
CMP
CORRUGATED METAL PIPE
CMU
CONCRETE MASONRY UNIT
CNTR
COUNTER
GO
CLEAN OUT
QRT
QUARTER
COL
COLUMN
QT
QUARRY TILE
COMM
COMMUNICATION
CONC
CONCRETE
CONN
CONNECTION
R
CON5T5
CONSTRUCTION
CONT
CONTINUOUS
R
REAR
CPT
CARPET TILE
RA
RETURN AIR
CT
CERAMIC TILE
RAD
RADIUS
CTR
CENTER
RB
REINFORCED BEAM
CTSK
COUNTERSUNK
RCPT
RECEPTION
RD
ROOF DRAIN
�q
REINF
REFERENCE
D
REINFORCED
REQ
REQUIRED
DBL
DOUBLE
RESL
RESILIENT
DEG
DEGREE
RGTR
P-EG15TER
DEPT
DEPARTMENT
RM
ROOM
DESIG
DESIGNATION
RO
ROUGH OPENING
DET
DETAIL
RWL
RAIN WATER LEADER
DF
DRINKING FOUNTAIN
DG
DOOR GRILLE
DIA
DAMETER
I
DIA L
DAGRAM
DIM
DIMENSION
5
STUCCO
D15R
DISPENSER
5C
SCREED CONCRETE
DN
DOWN
SCHED
SCHEDULE
pO
DOOR OPENING
G
SEC
SECOND
D5P
DRY STANDPIPE
SMOKE DETECTOR
D5
DOWN SPOUT
SECT
SECTION
DwkxS
DRAWINGS
Sr
FAN
DWR
DRAWER
SG
SPANDREL GLASS
5MR
IC GRADE
SHOWER
SHT
SHEET
EA
EACH
51G
SIGNAL
EC
EPDXY COATING
AR
EWD
ELECTRIC NAND DRYER
5K
51NIG
EL
ELEVATION
5M
5HEET METAL
EJ
EXPANSION JOINT
5MK
SMOKE
ELEC
ELECTRICAL
SND
SOUND
ELEV
ELEVATOR
5PEC
SPECIFICATION
EMER
EMERGENCY
5PKR
5PEAKER5
ENCL
ENCLOSURE
SO!
SQUARE
ENGR
ENGINEER
SQFT
SQUARE FEET
EPNL
ELECTRICAL PANEL
55T
5TAINLE55 STEEL
EQ
EQUAL
ST
STREET
EQPT
EQUIPMENT
5TC
SOUND TRANSMISSION COEFFICIENT
EST
ESTIMATE
5TD
STANDARD
ET
EXPANSION TANK
5T -D
STORM DRAIN
EW'G
ELECTRIC WATER COOLER
STL
STEEL
EXH
EXHAU5T
STRL
STRUCTURAL
EX ST
EXISTING
SU5P
5USPENDEp
EXT
EXTERIOR
SYM
SYMMETRICAL
SY5
SYSTEM
FA
FIRE ALARM
FABL
FIRE ALARM BELL
T
TOILET
FD
FLOOR DRAIN
TB
TIE BEAM
FG
FIBERGLA55
TC
TIE COLUMN
FCO
FLOOR CLEANOUT
TEL
TELEPHONE
FD
FIRE DAMPER
TEMP
TEMPERATURE
FDC
FIRE DEPARTMENT CONNECTOR
T45
TONGUE AND GROVE
FDR
FIRE DOOR
THK
THICK
FDN
FOUNDATIONS
TOC
TOP OF CURB
FDV
FIRE DEPARTMENT VALVE
TOPP
TOP OF PARAPET
FEC
FIRE EXTINGUISHER CABINET
T05
TOP OF SLAB
FEX
FIRE EXTINGUISHER
TP
TOP OF PAVEMENT
FF
FNISH FLOOR
TRIP
TREAD
FH
FIRE HYDRANT
T5
TUBULAR STEEL
FIN
FINISH
TSTAT
THERMOSTAT
FL
FLOOR
TV
TELEVISION
FM
FACTORY MANUAL
Tw
TOP OF WALL
FLASH
FLASHING
TYP
TYPICAL
FLG
FLANGE
FLOUR
FLUORESCENT
FOC
FACE OF CONCRETE
FOF
FACE OF FINISH
US
UNDERCUT
FOM
FACE OF MASONRY
UL
UNDERWRITER'5 LABORATORIES
FOS
FACE of STUD
UNF
UNFINISHED
FPRF
FIREPROOF
LION
UNLE55 OTHERWISE NOTED
U05
UNLESS OTHER SPECIFIED
FPM
FEET PER MINUTE
UR
URINAL
FRD
FRENCH DRAIN
UTIL
UTILITY
FS
FULL SIZE
FT
FOOT OR FEET
V
FTG
FOOTING
FT -LB
FOOT POUNDS
FURR
FURRING
VB
VINYL BASE
FUT
FUTURE
VCT
VINYL COMPOSITION TILE
vERT
VERTICAL
VE5T
VESTIBULE
cz
VF
VERIFY IN FIELD
VOL
VOLUME
GA
GAUGE
VT
VAPOR TIGHT
GAL
GALLON
VTR
VENT THRU ROOF
GALV
GALVANIZED
GB
GRADE BEAM
W
GEN
GENERATOR
GL
GLASS
WR
WIRE
GND
GROUND
W
WINDOW
GLB
GLA55 BLOCK
w/
WITH
GR
GRILLE
WC
WATER CLOSET
GIRD
GRADE
WCO
WALL CLEANOUT
GWB
GYP5UM WALL BOARD
wD
wooD
GYP
GYPSUM
U,F
WALL FABRIC
W/o
WITHOUT
wP
WATER PROOF
wSCT
WAINSCOT
WT
WEIGHT
W'il.F
WELDED WIRE FABRIC
HB
HOSE BIB
WUM
WELDED WIRE MESH
HC
HANDICAPPED
HDWD
HARDWOOD
HDWE
HARDWARE
HGT
HEIGHT
HM
HOLLOW METAL
HORIZ
HORIZONTAL
WP
HIGH POINT
HR
HOUR
HTR
HEATER
HVAG
HEATING, VENTILATION,.! AIR CONDITIONING
HYD
HYDRANT
ID
NSIDE DIAMETER ( PIAM 1
INCHES
AwiTnTT�
INT
NCHES
INTERIOR
C�
_ t
JAN
JANITOR
JB
JUNCTION BOX
JCT
JUNCTON
JSK
JANITORS SINK
JT
JOINT
K
KNOCK OUT