14-523-003I
a
Affiliate of Baptist Health Systems of South Hod
A-000111k, A
I.- CONTRACTOR IS BEING PROVIDED WITH COMPLETE SETS OF
DOCUMENTS. CONTRACTOR IS RESPONSIBLE F02 PROVIDING
SUBCONTRACTORS WITH COMPLETE SETS OF DRAWINGS. INTENT
IS F02 ALL SYSTEMS AND EQUIPMENT TO BE PROVIDED WITH
UTILITY CONNECTIONS AS REQUIRED F02 OPERATION.
EXAMPLE = IF A SINK IS SHOWN IN THE ARCHITECTURAL PLANS.
THE PLUMBING PLANS DO NOT SHOW A WATER 02 DRAWINGS
CONNECTION THE ENGINEER WILL PROVIDE THE DESIGN DETAILS
IN ACCO2DANCE WITH THE DESIGN CRITERIA FOR THE REST OF
THE INSTALLATIONS. CONTRACTOR IS RESPONSIBLE FOR PRO-
VIDING THE CONNECTION AT NO ADDITIONAL COST TO THE OW-
NER.
2.- CONTPACT02 IS RESPONSIBLE FOR VISITING THE SITE DURING
THE BIDDING PERIOD AND VERIFY THAT THE CONDITION ARE
AS DESCRIBED IN THE DOCUMENTS. DISCREPANCIES ARE TO
BE NOTED IN WRITING, AND NOTIFY ARCHITECT / ENGINEERS.
CONTRACTOR ACCEPTS CONDITIONS AS THEY ARE ON THE SITE,
AND MUST PROVIDE SYSTEMS AND WORK AS DESCRIBED IN THE
CONTRACT DOCUMENTS AT NO ADDITIONAL COST TO THE OWNER.
3.- DIMENSIONS PROVIDED ARE NOMINAL NOT ACTUAL. THEY TAKE
AS A BASIS EXISTING WALLS. IF DISCREPANCIES ARE FOUND,
NOTIFY ARCHITECT IMMEDIATELY FOR COORDINATION. IF CON -
TRACT02 PROCEEDS, HE DOES SO AT HIS OWN RISK AND IS
RESPONSIBLE FOR ALL EXPENSES INCURRED IF AT THE DISCRE
TION OF THE OWNER OR THE ARCHITECT THE WORK HAS TO BE
RE -DONE,
4.- SHUTDOWN OF UTILITIES! IF A SHUTDOWN 02 ANY TYPE OF INTER-
FERENCE WITH EXISTING SYSTEMS IS ANTICIPATED THE CONTRAC
TOR MUST NOTIFY THE OWNER 72 HOURS IN ADVANCE AND OBTA-
IN APPROVAL IN WRITING PRIOR TO PROCEEDING.
5.- CONTRACT02 SHALL TAKE ALL NECESSARY PRECAUTIONS AND
USE ALL APPROPRIATE CONSTRUCTION METHODS / TECHNIQUES
TO PROTECT EXISTING UTILITIES AND OTHER PROPERTY NOT
NOTED FOR REMOVAL, CONTRACTOR SHALL BE RESPONSIBLE
FOR ANY DAMAGES INCURRED DURING CONSTRUCTION AND
SHALL REPAIR ANY DAMAGES AT NO EXPENSE TO THE OWNER,
6.- IF THERE IS A DISCREPANCY BETWEEN THE DRAWINGS AND THE
SPECIFICATIONS, THE CONTRACTOR IS TO OBTAIN CLARIFICATION
DURING THE BIDDING PERIOD. IF THE DISCREPANCY COMES UP
DURING THE CONSTRUCTIONIT IS ASSUMED THE CONTRACTOR BID
THE MOST EXPENSIVE WAY AND WILL DO THE WORK AS PER THE
DIRECTION OF THE OWNER /ARCHITECT AT NO ADDITIONAL COST
TO THE OWNER.
7.- ABBREVIATIONS THROUGHOUT THE PLANS ARE THOSE IN COM-
MON USE ARCHITECT WILL DEFINE INTENT OF ANY IN QUESTION.
8.- THE CONTRACTOR SHALL PROVIDE ALL NECESSARY TEMPORARY
BARRIERS, LIGHTING, COVERINGS, FIRE PREVENTION AND OTHER
EQUIPMENT TO PROTECT THE SAFETY OF ALL PERSONS AND THE
PROPERTY THROUGHOUT THE ENTIRE PERIOD OF THE CONSTRUC _
TION CONTRACT.
9.- THE CONTRACTOR SHALL VERIFY SIZES AND LOCATIONS OF ALL
OPENINGS FOR MECHANICAL, ELECTRICAL AND PLUMBING EQUIPMENT
WITH SUBCONTRACTORS, AS WELL AS SHOP DRAWINGS AS APPROVED
BY A20HITECT, BEFORE PROCEEDING WITH THE WORK,
10.- ALL ITEMS USED IN CONSTRUCTION, BUT NOT SPECIFICALLY MENTIONED
HEREIN, SHALL CONFORM TO ALL LOCAL CODES AND STATE ORDINANCES
AS TO APPLICATION AND USE.
II.- PROVIDE ELECTRIC INSULATION BETWEEN ALL DISSIMILAR METAL
AND ALSO BETWEEN CEMENT AND METAL.
12.- THE CONTRACTOR SHALL BE RESPONSIBLE F02 OBTAINING ALL
PERMITS TO COMPLETE THE PROJECT,
13.- CONTRACTOR TO REVIEW ALL EXISTING BUILDING SYSTEMS AS TO THEIR
COMPLIANCE WITH ALL LOCAL AGENCY REQUIREMENTS AND BRING ANY
NON - CONFORMING ITEMS TO ARCHITECTS AND ENGINEER'S ATTENTION.
14.° GENERAL CONTRACTOR IS TO PROTECT EXISTING ADJACENT AREAS TO
WHERE WORK IS TO BE PERFORMED. ANY EXISTING MILLWORK,
EQUIPMENT DAMAGED DUE TO WORK PERFORMED SHALL BE REPAIRED/
REPLACED TO MATCH EXISTING (TYPICAL UNLESS OTHERWISE NOTED).
15.- DRAWINGS ARE SCHEMATIC SHOWING RELATIVE LOCATIONS AND
CONNECTIONS AND SHALL NOT BE SCALED AT ANY TIME,
16.- ALL WOOD BLOCKING WITHIN BUILDING STRUCTURE, SHALL BE FIRE -
RETARDANT TREATED AS PER SPECIFICATIONS.
17,- GENERAL CONTRACTOR SHALL INSPECT ALL EXISTING RATED WALLS /
PARTITIONS WITHIN SCOPE OF WORK AREA. CONTRACTOR SHALL UPGRADE
- EXISTING PARTITIONS AS REQUIRED TO MAINTAIN THE INTEGRITY
OF THE DESIGNATED RATING.
I8.-° ELEVATION AND LEVELS!
A. ALL NUMERICAL ELEVATIONS ARE TO TOP OF CONCRETE SLAB.
UNLESS NOTED OTHERWISE.
19.- ALL INTERIOR GYPSUM WALL BOARD IS 5/8' TYPE X G.W.B. ON METAL
STUDS OR FURRING CHANNELS UNLESS NOTED OTHERWISE, SIZES AS
DIMENSIONED ON FLOOR PLANS. SEE NOTES 9 FOR LOCATION OF
WATER RESISTANT G.W.B.
20. PROVIDE WATER RESISTANT TYPE X G.W.B. IN ALL TOILETS.
AND JANITOR'S CLOSETS.
21,- BEFORE PATCHING ANY FIRE - RATED C.M.U. PARTITION. FILL ANY
EXPOSED CELLS SOLID WITH GROUT.
22.- PROVIDE FINISH WALL UNDER AND BEHIND ALL EQUIPMENT AND CASEWORK.
23.- LOCATION AND SIZE OF CEILING AND WALL ACCESS PANELS SHALL BE
DETERMINED BY THE POSITION OF VALVES AND OTHER MECHANICAL AND
ELECTRICAL ITEMS WHICH REQUIRE ACCESS. THE CONTRACTOR SHALL
COORDINATE WITH ALL TRADES. THE ARCHITECT SHALL REVIEW AND
APPROVE ALL FINAL LOCATION OF ACCESS PANELS PRIOR TO
INSTALLATION.
24.- THERE SHALL BE NO BACK - TO BACK ELECTRICAL TELEPHONE
OR OTHER OUTLETS.
25: ALL VERTICAL PIPING AND COLUMNS, EXPOSED IN ROOMS SHALL BE
FURRED WITH METAL STUDS AND DRY WALL AND FINISHED TO MATCH
ADJACENT WALLS, UNLESS NOTED OTHERWISE, EXCEPTIONS!
A. ELECTRIC CLOSETS C. MECHANICAL ROOMS
B• TELEPHONE CLOSETS D. STAIRS
26,- WHERE "VAC 02 OTHER MECHANICAL, ELECTRICAL AND PLUMBING ITEMS
PENETRATE PARTITIONS, STUDS SHALL BE BRACED AND FRAMED TO
STRUCTURE AS REQUIRED TO PROVIDE ADEQUATE SUPPORTS, ALL
PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED TO PROVIDE
FIRE, SMOKE AND / OR ACOUSTICAL ISOLATION OF SPACES WITH
APPROPRIATE FIRE S.T.0 MATERIAL.
27.- SEE INTE2102 ELEVATIONS FOR FINISHES AND FINISH DETAILS F02 INTE21012
SPACES. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR
ACOUSTICAL TILE FINISH.
28.- SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATION OF
CEILING MOUNTED MECHANICAL, ELECTRICAL FIXTURES.
29.- STAGGER JOINTS VERTICALLY AND HORIZONTALLY IN ALL G.WB. PARTITIONS
EA. SIDE OF PARTITION, JOINTS STAGGERED MINIMUM 2'-0'.
UNLESS OTHERWISE NOTED,
30, CONTRACTOR SHALL CONFIRM THAT ALL EXISTING EXPOSED
STEEL COMPLIES WITH N.F.P.A FIRE PROTECTION REQUIRE-
MENTS. CONTRACTORSHALL PROVIDE ALL NECESSARY INSULA-
TION /FIRE PROTECTIVE COATINGS.
31. CONTRACTOR TO SUBMIT ALL SHOP DRAWING TO ARCHITECT AND
THE BUILDING DEPARTMENT F02 APPROVAL (ELEVATOR, TRUSSES,
WINDOWS, ETC.)
32. CONTRACTOR REQUIRED TO PULL SEPARATE DEMOLITION PERMIT.
6200 SW 73RD ST
(786) r 5
MIAMI ,FL* 33145
FAX: (305) 662 - 4653
AHCA STAGE III - PROJECT ID #: 23/100154 -203 -1
DECEMBER 13, 2013
(INTERIOR REMODELING ONLY)
0 A
H I
A1111k AMU
I A.M C
r h t %of
2121 Ponce de lean Blvd„ Suite 350
Coral Gables, Fl 33134 FLORIDA LICENSE #AA0002689
Professional Consulting Engineers phone, 305.569.1692
fax: 305.569.1693 2100 PONCE DE LEON BLVD. SUITE 1170, CORAL GABLES, FL 33134
Dallas * Houston * Nashville * Miami * Richmond
ccrd project number: Tel: (305)265 -7177 Faux: (305)262 -8435
EB00007658 LUIS E. MAYA, A *I *A Fl. AR0008063
PROJECT NUMBER: 201316
INDEX OF DRAWINGS
CS -1 COVER SHEET,
C ITY MAP LIFE SAFETY PLUMBING
LS--1 PARTIAL SECOND FLOOR LIFE SAFETY PLAN AND ICRA DIAGRAM. P2.02 PARTIAL 2ND FLOOR PLAN,
LS -2 PARTIAL FIRST FLOOR LIFE SAFETY PLAN.
ARCHITECTURAL FIRE PROTECTION
F2.02 PARTIAL 2ND FLOOR NEW WORK PLAN.
A -1 PARTIAL 2ND FLOOR DEMOLITION PLAN, LEGEND AND DETAILS.
A A - i PARTIAL 2ND FLOOR DEMOLITION REFLECTED CEILING PLAN.
t� o c ti c
A -2 PARTIAL 2ND FLOOR PLAN, LEGEND, NOTES AND DETAILS.
ELECTRICAL
A -3 EQUIPMENT AND REFLECTED CEILING PLAN, LEGEND AND NOTES.
A -4 PARTIAL DEMOLITION ROOF PLAN , NOTES, AND DETAILS.
1 A -4A PARTIAL ROOF PLAN - NEW WORK, NOTES AND DETAILS E0.00 GENERAL INFORMATION,
g EO.01 GENERAL INFORMATION.
A -5 PARTITION TYPES, NOTES AND DETAILS.
••. x� � ED1.02 PARTIAL 2ND FLOOR DEMOLITION PLAN,
4, Sri : c .{ a A -6 INTERIOR ELEVATIONS, DOOR SCHEDULE, NOTES AND DETAILS. E2,02 PARTIAL 2ND FLOOR NEW WORK PLAN.
- A -7 PENETRATION AND FIRE RATING DETAILS,
E3.02 PARTIAL 2ND FLOOR NEW WORK - SYSTEMS.
- A -8 PENETRATIONS AND FIRE RATING DETAILS.
" uen G,lami i F a A -9 PENETRATIONS AND FIRE RATING DETAILS, E6.01 PARTIAL ELECTRICAL ONE -LINE DIAGRAM.
4 u�� E6.02 ELECTRICAL STUDIES.
FE7.01 ELECTRICAL DETAILS.
f ' E7.02 ELECTRICAL DETAILS.
MECHANICAL E8.01 ELECTRICAL SCHEDULES.
E8.02 ELECTRICAL SCHEDULES.
¢ r
w * w •! �` 1 �,' , � M0.00 GENERAL NOTES: SCHEDULES AND DETAILS. CMD1.02 PARTIAL SECOND FLOOR DEMOLITION PLAN COMMUNICATIONS,
MD1.02 PARTIAL 2ND FLOOR DEMOLITION PLAN. CM1.02 PARTIAL SECOND FLOOR PLAN - COMMUNICATIONS.
_, 'r`TT
,��". "� � •^ w � Y . n _ .'1 M2.02 PARTIAL 2ND FLOOR NEW WORK PLAN.
Sw s M3,02 PARTIAL 2ND FLOOR NEW WORK PLAN.
M7.01 MECHANICAL DETAILS,
M -ICRA PARTIAL SECOND FLOOR ICRA PLAN.
ww3 y »I. i sAry
0, �f c"wmrf ,'u ' S:IPd tic n
.�s r3���ti
'.�. .ne:r.4:., k..�..s -a„°,7
AREA P INTERIOR MODIFICATIONS Oa� Y
(ANY FXTER IOR MODIFICATION MAY REQUIRE
A BOARD APPEARANCE)
BUILDING INFORMATION R]��TI ICON
N., / c
ORIGINAL BUILDING DESCRIPTION 03 -07 -14
�f1 FiVAC CHANGES
� �• j � \� BUILDING
s' 7aF COUNTY } ! �,,, Fr JURISDICTION : DADE, 04 -03 -14
PRIMARY USE CLASS : HEALTHCARE PERE DEPARTMENT COMMENTS
CONSTRUCTION TYPE (NFPA) : TYPE 1 (3,3,2)
CONSTRUCTION TYPE : TYPE 1, FLORIDA BUILDING CODE
S'U711MAN1110SPITAL sY ^• NUMBER OF STORIES : 7 STORIES
4aoo sov sieecl
A i I
NEW PROJECT DESCRIPTION
,� rsw ast� vt �-;,; „ a
3 is 4 r PROJECT AREA: : TOTAL: 860 SQ.FT.
n ,r SPRINKLED : TOTAL: FULLY SPRINKLED
• V
APPLICABLE CODES
• 4 m m N h �
FLORIDA BUILDING CODE 2007 EDITI WO VISION.
s h
* FLORIDA FIRE PREVENTION COD DITION.
f s xo A J * F A 0 E 0 DITION 2+
CHAP'T'ER 19 EXISTING E T E ,
• ALA GUIDELINES FOR DESIGN AND CONSTRUCTION OF
1b s W HEALTH CARE FACILITIES 2010 EDITION.
U V VUi
A EVIATION S' V yyJJ
_ JyJ�JJ
4 AND L
L ANGLE L yyyy LENGTHY
6 AT J
C CENTERING LAM,, `LAMINATEy J V V V y y y J V
O DIAMETER LAV, y r
V y LAVA eOR
" POUNIA OR NUMBER LOS POUNDS
L156/14R POUNDS PER HOUR
A LD LINEAR DIFFUSER
LP LOW POINT
A/C AIR CONDITIONING LT LIGHT
ACI AMERICAN CONCRETE INSTITUTE
ACP ASBESTOS CEMENT PIPE M
ACSC ASPHALTIC CONCRETE SURFACE COURSE
ACU AIR CONDITIONING UNIT
ACT ACOUSTICAL CEILING TILE MAIL MATERIAL
AD AREA DRAIN MAX MAXIMUM
ADJ ADJUSTABLE MC MEDICINE CABINET
A/E ARCHITECT /ENGINEER MECH MECHANICAL
AF ACCESS FLOORING MEMO MEMBRANE
AFF ABOVE FINISHED FLOOR MFR MANUFACTURER
AGGR AGGREGATE MIN MINIMUM
AHU AIR HANDLING UNIT MISC M15CELANEOUS
ALT ALTERNATE MO MASONRY OPENING
AL ALUMINUM MTD MOUNTED
ANN ANNUNCIATOR MTL METAL
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE MUL MULLION
ANT ANTENNA MULT MULTIPLE
AP ACCESS PANEL
APL ACCESS PLENUM
APROX APPROXIMATE N
ARCH ARCHITECTURAL
ASE, ASBESTOS N NORTH
ASPH ASPHALT NEC NATIONAL ELECTRIC CODE
A5TM AMERICAN SOCIETY OF TESTING d MATERIALS NIC NOT IN CONTRACT
NO NUMBER
Is ROM NOMINAL
NFL NAME PLATE
BAT BATTERY NTS NOT TO SCALE
BD 130ARD
BITUM BITUMINOUS
BLDG BUILDING
BLK5 13LOCKING
BM BEAM OA OVERALL
BOT BOTTOM 055 OBSCURE
OG ON CENTER
�* OD OUTSIDE DIAMETER DIM)
OFS OVERFLOW SCUPPER
CAB CABINET OFT, OPPOSITE
CB CATCH BASIN
CEM CEMENT P
CER CERAMIC
CFM CUBIC FEET PER MINUTE PC PRECAST CONCRETE
CG CORNER GUARD Pi PIPE JOINT
CHIP CRICKET HIGH POINT PL PLASTIC
GI CAST IRON P LAM PLASTIC LAMINATE
GIG CAST IRON COVER PLAS PLASTER
GIP CAST IRON PIPE PLYWD PLYWOOD
CJ CONTROL JOINT PNT PAINT
CLG CEILING PT POINT OR PATIENT
CL CEILING DIFFUSER PTD PAPER TOWEL DISPENCER
GLKG CAULKING PTN PARTITION
CLO CLOSET PTR PAPER TOWEL RECEPTACLE
CLIP CRICKET LOW POINT
CLIP CLOSER
Clip CORRUGATED METAL PIPE Gt
CMU CONCRETE MASONRY UNIT
CNTR COUNTER
CO CLEAN OUT QRT QUARTER
COL COLUMN QT QUARRY TILE
COMM COMMUNICATION
CONG CONCRETE
CONN CONNECTION R
CONST5 CONSTRUCTION
CONT CONTINUOUS R REAR
CPT CARPET TILE RA RETURN AIR
CT CERAMIC TILE RAD RADIUS
CTR CENTER RB REINFORCED 15EAM
CTSK COUNTERSUNK RCPT RECEPTION
RD ROOF DRAIN
RE�.p RRE NF REFERENCE
REQ REQUIRED
DBL DOUBLE RE5L RE51LIENT
DEG DEGREE RGTR REG15TER
DEPT DEPARTMENT RM ROOM
DESIG DESIGNATION RO ROUGH OPENING
DET DETAIL RWL RAIN WATER LEADER
DF DRINKING FOUNTAIN
DG DOOR GRILLE
PIA DIAMETER
DIAG DIAGRAM
DIM DIMENSION g STUCCO
DISK DISPENSER 5c SCREED CONCRETE
DO DOOR OPENING
ON DO 5CHED SCHEDULE
5EC SECOND
D5P DRY STANDPIPE 5D SMOKE DETECTOR
DWG 5 DRAWINGS D5 D SPOUT SECT SECTION
DWR DRAWER 5F SUPPLY FAN
SG SPANDREL GLASS
SGR SYNTHETIC GRADE
SHR SHOWER
EA EACH SHT SHEET
EC EPDXY COATING SIG SIGNAL
AR
EHD ELECTRIC NAND DRYER SK SINK
EL ELEVATION 5M SHEET METAL
EJ EXPANSION JOINT SMK SMOKE
ELEC ELECTRICAL SNP SOUND
ELEY ELEVATOR SPEC SPECIFICATION
EMER EMERGENCY SPKR SPEAKERS
ENCL ENCLOSURE SQ SQUARE
ENGR ENGINEER SQFT SQUARE FEET
EPNL ELECTRICAL PANEL SST STAINLESS STEEL
EQ EQUAL 5T STREET
EQPT EQUIPMENT 5TC SOUND TRANSMISSION COEFFICIENT
EST ESTIMATE STD STANDARD
ET EXPANSION TANK ST -D STORM DRAIN
EWC ELECTRIC WATER COOLER STL STEEL
EXH EXHAUST STRL STRUCTURAL
EX5T EXISTING SU5P SUSPENDED
EXT EXTERIOR SYM SYMMETRICAL
SYS SYSTEM
FA FIRE ALARM
FABL FIRE ALARM BELL T TOILET
FD FLOOR DRAIN T6 TIE BEAM
I A5
FG F BERGL 5 TC TIE COLUMN
FCO FLOOR CLEANOUT TEL TELEPHONE
FD FIRE DAMPER TEMP TEMPERATURE
FDC FIRE DEPARTMENT CONNECTOR T4G TONGUE AND GROVE
FDR RE DOOR THK THICK
FDN FOUNDATIONS TOC TOP OF CURB
FDV FIRE DEPARTMENT VALVE TOPP TOP OF PARAPET
FEC FIRE EXTINGUISHER CAE31NET TOS TOP OF SLAB
FEX FIRE EXTINGUISHER TP TOP OF PAVEMENT
FF FINISH FLOOR TRD TREAD
FH FIRE HYDRANT TS TUBULAR STEEL
FIN FINISH TSTAT THERMOSTAT
FL FLOOR TV TELEVISION
FM FACTORY MANUAL TW TOP OF WALL
FLASH FLASHING TYP TYPICAL
FLG FLANGE
FLOUR FLUORESCENT u
FOC FACE OF CONCRETE
FOF FACE OF FINISH US UNDERCUT
FOM FACE OF MASONRY UL UNDERWRITER'S LA50RATORIE5
F05 FACE OF STUD UNF UNFINISHED
FPRF FIREPROOF UON UNLESS OTHERWISE NOTED
FPM FEET PER MINUTE UOS UNLESS OTHER SPECIFIED
FRD FRENCH DRAIN UR URINAL
FS FULL SIZE UTIL UTILITY
FT FOOT OR FEET u
FTG FOOTING
FT -LB FOOT POUNDS
FURR FURRING VB VINYL BASE
FUT FUTURE VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
G VF VERIFY IN FIELD
VOL VOLUME
GA GAUGE VT VAPOR TIGHT
GAL GALLON VTR vENT THRU ROOF
GALV GALVANIZED
GB GRADE BEAM W
GEN GENERATOR
GL GLASS WR WIRE
GND GROUND W WINDOW
GLB GLA55 BLOCK W/ WITH
GR GRILLE WC WATER CLOSET
GRID GRADE WCO WALL CLEANOUT
Gwe GYPSUM WALL 50ARD WD WOOD
GYP GYPSUM WF WALL FABRIC
W/O WITHOUT
N WP WATER PROOF
WSCT WAINSCOT
WT WEIGHT
HB HOSE BIB WWF WELDED WIRE FABRIC
HC HANDICAPPED WLLM WELDED WIRE MESH
HDWD HARDWOOD
HDWE HARDWARE
HGT HEIGHT
HM HOLLOW METAL
HORIZ HORIZONTAL
HIP HIGH POINT
HR HOUR
HTR HEATER
HVAC HEATING, VENTILATION, 4 AIR CONDITIONING
HYD HYDRANT
ID INSIDE DIAMETER l DIAM)`�T �n
IN INCHES Lc
INT INTERIORX
JAN JANITOR A µ
JB JUNCTION BOXeJ
JCT JUNCTION �` l
J5K JANITORS SINK'"
JT JOINT
cd,y
K
KO KNOCK OUT
IAA11 D-.A.�0E
s