14-523-003I a Affiliate of Baptist Health Systems of South Hod A-000111k, A I.- CONTRACTOR IS BEING PROVIDED WITH COMPLETE SETS OF DOCUMENTS. CONTRACTOR IS RESPONSIBLE F02 PROVIDING SUBCONTRACTORS WITH COMPLETE SETS OF DRAWINGS. INTENT IS F02 ALL SYSTEMS AND EQUIPMENT TO BE PROVIDED WITH UTILITY CONNECTIONS AS REQUIRED F02 OPERATION. EXAMPLE = IF A SINK IS SHOWN IN THE ARCHITECTURAL PLANS. THE PLUMBING PLANS DO NOT SHOW A WATER 02 DRAWINGS CONNECTION THE ENGINEER WILL PROVIDE THE DESIGN DETAILS IN ACCO2DANCE WITH THE DESIGN CRITERIA FOR THE REST OF THE INSTALLATIONS. CONTRACTOR IS RESPONSIBLE FOR PRO- VIDING THE CONNECTION AT NO ADDITIONAL COST TO THE OW- NER. 2.- CONTPACT02 IS RESPONSIBLE FOR VISITING THE SITE DURING THE BIDDING PERIOD AND VERIFY THAT THE CONDITION ARE AS DESCRIBED IN THE DOCUMENTS. DISCREPANCIES ARE TO BE NOTED IN WRITING, AND NOTIFY ARCHITECT / ENGINEERS. CONTRACTOR ACCEPTS CONDITIONS AS THEY ARE ON THE SITE, AND MUST PROVIDE SYSTEMS AND WORK AS DESCRIBED IN THE CONTRACT DOCUMENTS AT NO ADDITIONAL COST TO THE OWNER. 3.- DIMENSIONS PROVIDED ARE NOMINAL NOT ACTUAL. THEY TAKE AS A BASIS EXISTING WALLS. IF DISCREPANCIES ARE FOUND, NOTIFY ARCHITECT IMMEDIATELY FOR COORDINATION. IF CON - TRACT02 PROCEEDS, HE DOES SO AT HIS OWN RISK AND IS RESPONSIBLE FOR ALL EXPENSES INCURRED IF AT THE DISCRE TION OF THE OWNER OR THE ARCHITECT THE WORK HAS TO BE RE -DONE, 4.- SHUTDOWN OF UTILITIES! IF A SHUTDOWN 02 ANY TYPE OF INTER- FERENCE WITH EXISTING SYSTEMS IS ANTICIPATED THE CONTRAC TOR MUST NOTIFY THE OWNER 72 HOURS IN ADVANCE AND OBTA- IN APPROVAL IN WRITING PRIOR TO PROCEEDING. 5.- CONTRACT02 SHALL TAKE ALL NECESSARY PRECAUTIONS AND USE ALL APPROPRIATE CONSTRUCTION METHODS / TECHNIQUES TO PROTECT EXISTING UTILITIES AND OTHER PROPERTY NOT NOTED FOR REMOVAL, CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGES INCURRED DURING CONSTRUCTION AND SHALL REPAIR ANY DAMAGES AT NO EXPENSE TO THE OWNER, 6.- IF THERE IS A DISCREPANCY BETWEEN THE DRAWINGS AND THE SPECIFICATIONS, THE CONTRACTOR IS TO OBTAIN CLARIFICATION DURING THE BIDDING PERIOD. IF THE DISCREPANCY COMES UP DURING THE CONSTRUCTIONIT IS ASSUMED THE CONTRACTOR BID THE MOST EXPENSIVE WAY AND WILL DO THE WORK AS PER THE DIRECTION OF THE OWNER /ARCHITECT AT NO ADDITIONAL COST TO THE OWNER. 7.- ABBREVIATIONS THROUGHOUT THE PLANS ARE THOSE IN COM- MON USE ARCHITECT WILL DEFINE INTENT OF ANY IN QUESTION. 8.- THE CONTRACTOR SHALL PROVIDE ALL NECESSARY TEMPORARY BARRIERS, LIGHTING, COVERINGS, FIRE PREVENTION AND OTHER EQUIPMENT TO PROTECT THE SAFETY OF ALL PERSONS AND THE PROPERTY THROUGHOUT THE ENTIRE PERIOD OF THE CONSTRUC _ TION CONTRACT. 9.- THE CONTRACTOR SHALL VERIFY SIZES AND LOCATIONS OF ALL OPENINGS FOR MECHANICAL, ELECTRICAL AND PLUMBING EQUIPMENT WITH SUBCONTRACTORS, AS WELL AS SHOP DRAWINGS AS APPROVED BY A20HITECT, BEFORE PROCEEDING WITH THE WORK, 10.- ALL ITEMS USED IN CONSTRUCTION, BUT NOT SPECIFICALLY MENTIONED HEREIN, SHALL CONFORM TO ALL LOCAL CODES AND STATE ORDINANCES AS TO APPLICATION AND USE. II.- PROVIDE ELECTRIC INSULATION BETWEEN ALL DISSIMILAR METAL AND ALSO BETWEEN CEMENT AND METAL. 12.- THE CONTRACTOR SHALL BE RESPONSIBLE F02 OBTAINING ALL PERMITS TO COMPLETE THE PROJECT, 13.- CONTRACTOR TO REVIEW ALL EXISTING BUILDING SYSTEMS AS TO THEIR COMPLIANCE WITH ALL LOCAL AGENCY REQUIREMENTS AND BRING ANY NON - CONFORMING ITEMS TO ARCHITECTS AND ENGINEER'S ATTENTION. 14.° GENERAL CONTRACTOR IS TO PROTECT EXISTING ADJACENT AREAS TO WHERE WORK IS TO BE PERFORMED. ANY EXISTING MILLWORK, EQUIPMENT DAMAGED DUE TO WORK PERFORMED SHALL BE REPAIRED/ REPLACED TO MATCH EXISTING (TYPICAL UNLESS OTHERWISE NOTED). 15.- DRAWINGS ARE SCHEMATIC SHOWING RELATIVE LOCATIONS AND CONNECTIONS AND SHALL NOT BE SCALED AT ANY TIME, 16.- ALL WOOD BLOCKING WITHIN BUILDING STRUCTURE, SHALL BE FIRE - RETARDANT TREATED AS PER SPECIFICATIONS. 17,- GENERAL CONTRACTOR SHALL INSPECT ALL EXISTING RATED WALLS / PARTITIONS WITHIN SCOPE OF WORK AREA. CONTRACTOR SHALL UPGRADE - EXISTING PARTITIONS AS REQUIRED TO MAINTAIN THE INTEGRITY OF THE DESIGNATED RATING. I8.-° ELEVATION AND LEVELS! A. ALL NUMERICAL ELEVATIONS ARE TO TOP OF CONCRETE SLAB. UNLESS NOTED OTHERWISE. 19.- ALL INTERIOR GYPSUM WALL BOARD IS 5/8' TYPE X G.W.B. ON METAL STUDS OR FURRING CHANNELS UNLESS NOTED OTHERWISE, SIZES AS DIMENSIONED ON FLOOR PLANS. SEE NOTES 9 FOR LOCATION OF WATER RESISTANT G.W.B. 20. PROVIDE WATER RESISTANT TYPE X G.W.B. IN ALL TOILETS. AND JANITOR'S CLOSETS. 21,- BEFORE PATCHING ANY FIRE - RATED C.M.U. PARTITION. FILL ANY EXPOSED CELLS SOLID WITH GROUT. 22.- PROVIDE FINISH WALL UNDER AND BEHIND ALL EQUIPMENT AND CASEWORK. 23.- LOCATION AND SIZE OF CEILING AND WALL ACCESS PANELS SHALL BE DETERMINED BY THE POSITION OF VALVES AND OTHER MECHANICAL AND ELECTRICAL ITEMS WHICH REQUIRE ACCESS. THE CONTRACTOR SHALL COORDINATE WITH ALL TRADES. THE ARCHITECT SHALL REVIEW AND APPROVE ALL FINAL LOCATION OF ACCESS PANELS PRIOR TO INSTALLATION. 24.- THERE SHALL BE NO BACK - TO BACK ELECTRICAL TELEPHONE OR OTHER OUTLETS. 25: ALL VERTICAL PIPING AND COLUMNS, EXPOSED IN ROOMS SHALL BE FURRED WITH METAL STUDS AND DRY WALL AND FINISHED TO MATCH ADJACENT WALLS, UNLESS NOTED OTHERWISE, EXCEPTIONS! A. ELECTRIC CLOSETS C. MECHANICAL ROOMS B• TELEPHONE CLOSETS D. STAIRS 26,- WHERE "VAC 02 OTHER MECHANICAL, ELECTRICAL AND PLUMBING ITEMS PENETRATE PARTITIONS, STUDS SHALL BE BRACED AND FRAMED TO STRUCTURE AS REQUIRED TO PROVIDE ADEQUATE SUPPORTS, ALL PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED TO PROVIDE FIRE, SMOKE AND / OR ACOUSTICAL ISOLATION OF SPACES WITH APPROPRIATE FIRE S.T.0 MATERIAL. 27.- SEE INTE2102 ELEVATIONS FOR FINISHES AND FINISH DETAILS F02 INTE21012 SPACES. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR ACOUSTICAL TILE FINISH. 28.- SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATION OF CEILING MOUNTED MECHANICAL, ELECTRICAL FIXTURES. 29.- STAGGER JOINTS VERTICALLY AND HORIZONTALLY IN ALL G.WB. PARTITIONS EA. SIDE OF PARTITION, JOINTS STAGGERED MINIMUM 2'-0'. UNLESS OTHERWISE NOTED, 30, CONTRACTOR SHALL CONFIRM THAT ALL EXISTING EXPOSED STEEL COMPLIES WITH N.F.P.A FIRE PROTECTION REQUIRE- MENTS. CONTRACTORSHALL PROVIDE ALL NECESSARY INSULA- TION /FIRE PROTECTIVE COATINGS. 31. CONTRACTOR TO SUBMIT ALL SHOP DRAWING TO ARCHITECT AND THE BUILDING DEPARTMENT F02 APPROVAL (ELEVATOR, TRUSSES, WINDOWS, ETC.) 32. CONTRACTOR REQUIRED TO PULL SEPARATE DEMOLITION PERMIT. 6200 SW 73RD ST (786) r 5 MIAMI ,FL* 33145 FAX: (305) 662 - 4653 AHCA STAGE III - PROJECT ID #: 23/100154 -203 -1 DECEMBER 13, 2013 (INTERIOR REMODELING ONLY) 0 A H I A1111k AMU I A.M C r h t %of 2121 Ponce de lean Blvd„ Suite 350 Coral Gables, Fl 33134 FLORIDA LICENSE #AA0002689 Professional Consulting Engineers phone, 305.569.1692 fax: 305.569.1693 2100 PONCE DE LEON BLVD. SUITE 1170, CORAL GABLES, FL 33134 Dallas * Houston * Nashville * Miami * Richmond ccrd project number: Tel: (305)265 -7177 Faux: (305)262 -8435 EB00007658 LUIS E. MAYA, A *I *A Fl. AR0008063 PROJECT NUMBER: 201316 INDEX OF DRAWINGS CS -1 COVER SHEET, C ITY MAP LIFE SAFETY PLUMBING LS--1 PARTIAL SECOND FLOOR LIFE SAFETY PLAN AND ICRA DIAGRAM. P2.02 PARTIAL 2ND FLOOR PLAN, LS -2 PARTIAL FIRST FLOOR LIFE SAFETY PLAN. ARCHITECTURAL FIRE PROTECTION F2.02 PARTIAL 2ND FLOOR NEW WORK PLAN. A -1 PARTIAL 2ND FLOOR DEMOLITION PLAN, LEGEND AND DETAILS. A A - i PARTIAL 2ND FLOOR DEMOLITION REFLECTED CEILING PLAN. t� o c ti c A -2 PARTIAL 2ND FLOOR PLAN, LEGEND, NOTES AND DETAILS. ELECTRICAL A -3 EQUIPMENT AND REFLECTED CEILING PLAN, LEGEND AND NOTES. A -4 PARTIAL DEMOLITION ROOF PLAN , NOTES, AND DETAILS. 1 A -4A PARTIAL ROOF PLAN - NEW WORK, NOTES AND DETAILS E0.00 GENERAL INFORMATION, g EO.01 GENERAL INFORMATION. A -5 PARTITION TYPES, NOTES AND DETAILS. ••. x� � ED1.02 PARTIAL 2ND FLOOR DEMOLITION PLAN, 4, Sri : c .{ a A -6 INTERIOR ELEVATIONS, DOOR SCHEDULE, NOTES AND DETAILS. E2,02 PARTIAL 2ND FLOOR NEW WORK PLAN. - A -7 PENETRATION AND FIRE RATING DETAILS, E3.02 PARTIAL 2ND FLOOR NEW WORK - SYSTEMS. - A -8 PENETRATIONS AND FIRE RATING DETAILS. " uen G,lami i F a A -9 PENETRATIONS AND FIRE RATING DETAILS, E6.01 PARTIAL ELECTRICAL ONE -LINE DIAGRAM. 4 u�� E6.02 ELECTRICAL STUDIES. FE7.01 ELECTRICAL DETAILS. f ' E7.02 ELECTRICAL DETAILS. MECHANICAL E8.01 ELECTRICAL SCHEDULES. E8.02 ELECTRICAL SCHEDULES. ¢ r w * w •! �` 1 �,' , � M0.00 GENERAL NOTES: SCHEDULES AND DETAILS. CMD1.02 PARTIAL SECOND FLOOR DEMOLITION PLAN COMMUNICATIONS, MD1.02 PARTIAL 2ND FLOOR DEMOLITION PLAN. CM1.02 PARTIAL SECOND FLOOR PLAN - COMMUNICATIONS. _, 'r`TT ,��". "� � •^ w � Y . n _ .'1 M2.02 PARTIAL 2ND FLOOR NEW WORK PLAN. Sw s M3,02 PARTIAL 2ND FLOOR NEW WORK PLAN. M7.01 MECHANICAL DETAILS, M -ICRA PARTIAL SECOND FLOOR ICRA PLAN. ww3 y »I. i sAry 0, �f c"wmrf ,'u ' S:IPd tic n .�s r3���ti '.�. .ne:r.4:., k..�..s -a„°,7 AREA P INTERIOR MODIFICATIONS Oa� Y (ANY FXTER IOR MODIFICATION MAY REQUIRE A BOARD APPEARANCE) BUILDING INFORMATION R]��TI ICON N., / c ORIGINAL BUILDING DESCRIPTION 03 -07 -14 �f1 FiVAC CHANGES � �• j � \� BUILDING s' 7aF COUNTY } ! �,,, Fr JURISDICTION : DADE, 04 -03 -14 PRIMARY USE CLASS : HEALTHCARE PERE DEPARTMENT COMMENTS CONSTRUCTION TYPE (NFPA) : TYPE 1 (3,3,2) CONSTRUCTION TYPE : TYPE 1, FLORIDA BUILDING CODE S'U711MAN1110SPITAL sY ^• NUMBER OF STORIES : 7 STORIES 4aoo sov sieecl A i I NEW PROJECT DESCRIPTION ,� rsw ast� vt �-;,; „ a 3 is 4 r PROJECT AREA: : TOTAL: 860 SQ.FT. n ,r SPRINKLED : TOTAL: FULLY SPRINKLED • V APPLICABLE CODES • 4 m m N h � FLORIDA BUILDING CODE 2007 EDITI WO VISION. s h * FLORIDA FIRE PREVENTION COD DITION. f s xo A J * F A 0 E 0 DITION 2+ CHAP'T'ER 19 EXISTING E T E , • ALA GUIDELINES FOR DESIGN AND CONSTRUCTION OF 1b s W HEALTH CARE FACILITIES 2010 EDITION. U V VUi A EVIATION S' V yyJJ _ JyJ�JJ 4 AND L L ANGLE L yyyy LENGTHY 6 AT J C CENTERING LAM,, `LAMINATEy J V V V y y y J V O DIAMETER LAV, y r V y LAVA eOR " POUNIA OR NUMBER LOS POUNDS L156/14R POUNDS PER HOUR A LD LINEAR DIFFUSER LP LOW POINT A/C AIR CONDITIONING LT LIGHT ACI AMERICAN CONCRETE INSTITUTE ACP ASBESTOS CEMENT PIPE M ACSC ASPHALTIC CONCRETE SURFACE COURSE ACU AIR CONDITIONING UNIT ACT ACOUSTICAL CEILING TILE MAIL MATERIAL AD AREA DRAIN MAX MAXIMUM ADJ ADJUSTABLE MC MEDICINE CABINET A/E ARCHITECT /ENGINEER MECH MECHANICAL AF ACCESS FLOORING MEMO MEMBRANE AFF ABOVE FINISHED FLOOR MFR MANUFACTURER AGGR AGGREGATE MIN MINIMUM AHU AIR HANDLING UNIT MISC M15CELANEOUS ALT ALTERNATE MO MASONRY OPENING AL ALUMINUM MTD MOUNTED ANN ANNUNCIATOR MTL METAL ANSI AMERICAN NATIONAL STANDARDS INSTITUTE MUL MULLION ANT ANTENNA MULT MULTIPLE AP ACCESS PANEL APL ACCESS PLENUM APROX APPROXIMATE N ARCH ARCHITECTURAL ASE, ASBESTOS N NORTH ASPH ASPHALT NEC NATIONAL ELECTRIC CODE A5TM AMERICAN SOCIETY OF TESTING d MATERIALS NIC NOT IN CONTRACT NO NUMBER Is ROM NOMINAL NFL NAME PLATE BAT BATTERY NTS NOT TO SCALE BD 130ARD BITUM BITUMINOUS BLDG BUILDING BLK5 13LOCKING BM BEAM OA OVERALL BOT BOTTOM 055 OBSCURE OG ON CENTER �* OD OUTSIDE DIAMETER DIM) OFS OVERFLOW SCUPPER CAB CABINET OFT, OPPOSITE CB CATCH BASIN CEM CEMENT P CER CERAMIC CFM CUBIC FEET PER MINUTE PC PRECAST CONCRETE CG CORNER GUARD Pi PIPE JOINT CHIP CRICKET HIGH POINT PL PLASTIC GI CAST IRON P LAM PLASTIC LAMINATE GIG CAST IRON COVER PLAS PLASTER GIP CAST IRON PIPE PLYWD PLYWOOD CJ CONTROL JOINT PNT PAINT CLG CEILING PT POINT OR PATIENT CL CEILING DIFFUSER PTD PAPER TOWEL DISPENCER GLKG CAULKING PTN PARTITION CLO CLOSET PTR PAPER TOWEL RECEPTACLE CLIP CRICKET LOW POINT CLIP CLOSER Clip CORRUGATED METAL PIPE Gt CMU CONCRETE MASONRY UNIT CNTR COUNTER CO CLEAN OUT QRT QUARTER COL COLUMN QT QUARRY TILE COMM COMMUNICATION CONG CONCRETE CONN CONNECTION R CONST5 CONSTRUCTION CONT CONTINUOUS R REAR CPT CARPET TILE RA RETURN AIR CT CERAMIC TILE RAD RADIUS CTR CENTER RB REINFORCED 15EAM CTSK COUNTERSUNK RCPT RECEPTION RD ROOF DRAIN RE�.p RRE NF REFERENCE REQ REQUIRED DBL DOUBLE RE5L RE51LIENT DEG DEGREE RGTR REG15TER DEPT DEPARTMENT RM ROOM DESIG DESIGNATION RO ROUGH OPENING DET DETAIL RWL RAIN WATER LEADER DF DRINKING FOUNTAIN DG DOOR GRILLE PIA DIAMETER DIAG DIAGRAM DIM DIMENSION g STUCCO DISK DISPENSER 5c SCREED CONCRETE DO DOOR OPENING ON DO 5CHED SCHEDULE 5EC SECOND D5P DRY STANDPIPE 5D SMOKE DETECTOR DWG 5 DRAWINGS D5 D SPOUT SECT SECTION DWR DRAWER 5F SUPPLY FAN SG SPANDREL GLASS SGR SYNTHETIC GRADE SHR SHOWER EA EACH SHT SHEET EC EPDXY COATING SIG SIGNAL AR EHD ELECTRIC NAND DRYER SK SINK EL ELEVATION 5M SHEET METAL EJ EXPANSION JOINT SMK SMOKE ELEC ELECTRICAL SNP SOUND ELEY ELEVATOR SPEC SPECIFICATION EMER EMERGENCY SPKR SPEAKERS ENCL ENCLOSURE SQ SQUARE ENGR ENGINEER SQFT SQUARE FEET EPNL ELECTRICAL PANEL SST STAINLESS STEEL EQ EQUAL 5T STREET EQPT EQUIPMENT 5TC SOUND TRANSMISSION COEFFICIENT EST ESTIMATE STD STANDARD ET EXPANSION TANK ST -D STORM DRAIN EWC ELECTRIC WATER COOLER STL STEEL EXH EXHAUST STRL STRUCTURAL EX5T EXISTING SU5P SUSPENDED EXT EXTERIOR SYM SYMMETRICAL SYS SYSTEM FA FIRE ALARM FABL FIRE ALARM BELL T TOILET FD FLOOR DRAIN T6 TIE BEAM I A5 FG F BERGL 5 TC TIE COLUMN FCO FLOOR CLEANOUT TEL TELEPHONE FD FIRE DAMPER TEMP TEMPERATURE FDC FIRE DEPARTMENT CONNECTOR T4G TONGUE AND GROVE FDR RE DOOR THK THICK FDN FOUNDATIONS TOC TOP OF CURB FDV FIRE DEPARTMENT VALVE TOPP TOP OF PARAPET FEC FIRE EXTINGUISHER CAE31NET TOS TOP OF SLAB FEX FIRE EXTINGUISHER TP TOP OF PAVEMENT FF FINISH FLOOR TRD TREAD FH FIRE HYDRANT TS TUBULAR STEEL FIN FINISH TSTAT THERMOSTAT FL FLOOR TV TELEVISION FM FACTORY MANUAL TW TOP OF WALL FLASH FLASHING TYP TYPICAL FLG FLANGE FLOUR FLUORESCENT u FOC FACE OF CONCRETE FOF FACE OF FINISH US UNDERCUT FOM FACE OF MASONRY UL UNDERWRITER'S LA50RATORIE5 F05 FACE OF STUD UNF UNFINISHED FPRF FIREPROOF UON UNLESS OTHERWISE NOTED FPM FEET PER MINUTE UOS UNLESS OTHER SPECIFIED FRD FRENCH DRAIN UR URINAL FS FULL SIZE UTIL UTILITY FT FOOT OR FEET u FTG FOOTING FT -LB FOOT POUNDS FURR FURRING VB VINYL BASE FUT FUTURE VCT VINYL COMPOSITION TILE VERT VERTICAL VEST VESTIBULE G VF VERIFY IN FIELD VOL VOLUME GA GAUGE VT VAPOR TIGHT GAL GALLON VTR vENT THRU ROOF GALV GALVANIZED GB GRADE BEAM W GEN GENERATOR GL GLASS WR WIRE GND GROUND W WINDOW GLB GLA55 BLOCK W/ WITH GR GRILLE WC WATER CLOSET GRID GRADE WCO WALL CLEANOUT Gwe GYPSUM WALL 50ARD WD WOOD GYP GYPSUM WF WALL FABRIC W/O WITHOUT N WP WATER PROOF WSCT WAINSCOT WT WEIGHT HB HOSE BIB WWF WELDED WIRE FABRIC HC HANDICAPPED WLLM WELDED WIRE MESH HDWD HARDWOOD HDWE HARDWARE HGT HEIGHT HM HOLLOW METAL HORIZ HORIZONTAL HIP HIGH POINT HR HOUR HTR HEATER HVAC HEATING, VENTILATION, 4 AIR CONDITIONING HYD HYDRANT ID INSIDE DIAMETER l DIAM)`�T �n IN INCHES Lc INT INTERIORX JAN JANITOR A µ JB JUNCTION BOXeJ JCT JUNCTION �` l J5K JANITORS SINK'" JT JOINT cd,y K KO KNOCK OUT IAA11 D-.A.�0E s