Loading...
14-37R-002rrFaxcw+asr •••••••••••• CAUTION ......... OUnp Fp ® Fw�e,+aiu'eowmw POWER - LIMITED AND NON-POWER-LIMITED WIRING MUST ENTER THROUGH SEPARATE CONDUIT /SERVICE ENTRANCES AC POWER ENTRANCE INTO BACK BOX IS aw4saFieEn nenxa 000001 REQUIRED AT DESIGNATED LOCATION OF THE BACK BOX FAILURE 70 PROPERLY SEPARATE 120V NON -POWER4.IMITED WIRING FROM POWER - LIMITED nncaio+erwa�ss LOW VOLTAGE WIRING, WILL VOID THE UL LISTING FOR G% ¢.SS)fi /�Cd ^•�'u'" '� "�''' THE DEVICE AND WILL PREVENT THE INSTALLATION rxxes Fan FROM BEING CERTIFIED (SEE CHART INSTALLATION ��� UL us 4009 INSTRUCTION SHEET) ,a a` o- w,use 4010 w oa w.wnLasreo a� wx,aoewxaw FILL VOID OR CAVITY MATERIALS ion rawFawen nou.roa CLASSIFIED BY UNDERWRITERS -1228 LABORATORIES, INCE FOR USE IN System No.W -L THROUGH - PENETRATION JUne28, 2010 use, eMFAF aw ° n "� FIRESTOP SYSTEMS(XHEZ). F Rating - 1 and 2 Hr (See Item 1) my SEE CURRENT UL FIRE T Rating - 0, 1/2 and 1 Hr (See Item 3), ean�Fonrx RESiSTANCE DIRECTORY L Rating At Ambient - Less Than 1 CFM /sq ft 01-6, 00G9 4008 -8201 WIRING ENTRIES INTO BACK BOX L Rating At 400 F - 2 CFM /sq ft 4010 FACP WIRING ENTRIES INTO BACK BOX ,rxxca4aar rYFxkcouou, laGnpIFOR Lorw,anFar nwwnaiu,eowmw Fawenasa,eowmw 00000 1 00000 aananFaa A 3 anwew usarmwmw � A ,aewew �� >ti.•s r'i ,. r n,� , ate. '^ +..1: r.: -'L,?• y w •r.'ry'ckl -n_ •• 1�<'-- ., < -•.;i `� Fan FOYA:a rwnm w.wn Lnrteo .4 41000 4006/4008 2 A 2 16 �,rasu"wFOn raw Y use „raurFwFOn,aw aKY 400814008 FACP WIRING ENTRIES INTO BACK BOX SECTION A -A 41000 FACP WIRING ENTRIES INTO BACK BOX 1. Wall Assembly The 1 or 2 hr fire rated gypsum board /stud wall assembly shall be constructed of the materials and in the manner described in the Individual U400 or V400 series Wall and Partition Design in the DEVICE MOUNTING HEIGHTS UL Fire Resistance Directory and shall include the following construction features: A/C SUPPLY A. Studs- Wall framing shall consist of min 3 -5/8 in. (92 mm) wide steel channel studs spaced max 24 in. DIFFUSER (610 mm) OC. B. Gypsum Board* Thickness, type, number of layers and fasteners shall be as specified in the CEILING MOUNTED NOTE: MEASUREMENTS j individual U400 or V400 series Wall and Partition Design in the UL Fire Resistance Directory. Max area of SMOKE /HEAT 3' (MIN) CEILING 4' DETECTOR. ARE T THE CLOSEST 4 opening is 67 -1/2 sq. In. (435 sq cm) with max dimension of 22 -1/2 in. (572 mm). DETECTOR . THE \\ \\\ . The hourly F Rating of the firestop system is equal to the hourly fire rating of the wall 6" BELOW CEILING assembly in which it is Installed. 24" MIN HANDICAP BEDROOM STROBE AUDIO /VISUAL ACCEPTED HERE 4' 2. Through Penetrant One or more nom 2 in. (51 mm) clam (or smaller) rigid steel conduit or electrical VISUAL -ONLY 12' (MAX) metallic tubing (EMT) installed either concentrically or eccentrically within the firestop system. The annular DEVICES NHER space between conduits or tubing and periphery of opening shall be min 0 in. (0 mm, point contact) to max IMPORTANT NOTE HERE 1 -1/4 in. (32 mm). The space between conduits or tubing shall be min 1/4 in.(6 mm) to max 1 in. (25mm). �-) VERIFY EXACT MOUNTING Conduit or tubing to be rigidly supported on both sides of wall assembly. REQUIREMENTS WITH MANUFACTURERS DATA SHEETS 3. Fill,Void or Cavity Material* - Caulk or SeaMht 5/8 in. (16 mm) thickness of fill material applied within the annulus, flush with both surfaces of wall. Min 1/2 in. (13 mm) diam bead of caulk applied to 5' WALL MOUNTED the penetrant/gypsum board interface at the point contact location on both sides of wall. MORE THAN TWO VISIBLE SMOKE/HEA The hourly T Rating of the firestop system is 0 Hr when used in 1 Hr rated assemblies. APPLIANCES ARE NOT DOOR DETECTOR The T Rating for 2 Hr rated assemblies is 1/2 and 1 Hr for FireDam 150+ and IC 15WB and is 1 Hr for CP- PERMITTED ANY FIELD OF VIEW UNN LESS THEIR LESS 3" 25WB+ and FB -300 WT. FLASHES AS SYNCHRONIZED. .1j- NFPA 72 2007 EDITION SIDE WALL 3M COMPANY - CP 25WB+, FireDam 150 +, IC 15WB+ caulk or FB -3000 WT sealant. (SECTION 7.5.4.3.2) *Bearing the UL Classification Mark 80" MIN FIRE AANUAL 6" 96" MAX PHONE PULL NFPA 72 2007 DUCT JACK 3TA11ON EDITION DETECTOR MAGNETIC (SECTION 7.5.4.1) REMOTE TEST HOLDER * NOTE r FINISHED THIS MATERIAL WAS EXTRACTED BY 3M FIRE PROTECTION PRODUCTS FROM _ o ® WALL THE 2011 EDITION OF THE UL FIRE RESISTANCE DIRECTORY. 48" MAX (ADA 42" MIN /48" MAX (NFPA) NFPA 72 2007 FINISHED EDITION (SECTION 5,13.4) FLOOR System No.W -L -3001 G�pSSIfi /�O System No. C -A3-1044 ot,SSIP/ September 07, 2004 March 15, 2007 Gd (Formerly System No. 149) F Ratings - 2, 3, and 4 Hr (See Items 2A and 4) F Ratings - 1 and 2 Hr (See Item 1) U L Val e� T Rating - 0 Hr UL us T Ratings - 3/4, 1, 1 -1/2 and 2 Hr (See Item 2) L Rating At Ambient - 2 CFM /sq ft Val L Rating At Ambient - 15 CFM /sq ft (See Item 3) FILL VOID OR CAVITY MATERIALS L Rating At 400 F - less than 1 CFM /sq ft L Rating At 400 F - less than 1 CFM /sq ft (See Item 3) CLASSIFIED BY UNDERWRITER$ W Rating - Class I (See Item 4) FILL VOID OR CAVITY MATERIALS LABORATORIES, INC.0 FOR USE IN CLASSIFIED BY UNDERWRITERS THROUGH. PENETRATION LABORATORIES, INC.* FOR USE IN FIRESTOP SYSTEMS (XHEZ) THROUGH- PENETRATION 1 SEE CURRENT UL FIRE 2 4 FIRESTOP SYSTEMS (XHEZ) RESISTANCE DIRECTORY A SEE CURRENT UL FIRE 60L6, 90G9 4 RESISTANCE DIRECTORY 5OL6,9000 - .� 'a 3 2 A �, t SECTION A -A 1 1. Floor or Wall Assembly Lightweight or normal weight (100 -150 pcf or 1600 -2400 kg /m3) - - - concrete. Except as noted In table under Item 41 min thickness of solid concrete floor or wall assembly Is 4-1/2 In. (114 mm). Floor may also be constructed of any min 61n. (152 mm) thick UL classified hollow corerecast Concrete Units'When floor Is constructed of hollow core precast concrete units, packing material (Item 3) and caulk fill material (Rem 4) to be installed symmetrically on both sides of floor, flush with floor surface. Wail assembly may also be constructed of any UL ClasslfiEdncrete BlocWMax diam of opening Is In solid lightweight or normal weight concrete. Floor is 32 In. (813 mm). Max diam of opening In floor SECTION A -A constructed of hollow -core precast concrete units Is 7 In. (178 mm). See Concrete Blocks(CAZT) and'recast Concrete Unit(CFTV) categories In the Fire Resistance 1. Wall Assembly - The 1 or 2 hr fire -rated gypsum wallboard /stud wall assembly shall be constructed Directory for names of manufacturers. of the materials and In the manner described in the Individual U300 or U400 Series Wall or Partition 1A. Steel Sleev$Optlonal, not shown) -Max 15 In. (381 mm) ID (or smaller) Schedule 10 (or Designs In the UL Fire Resistance Directory and shall Include the following construction features: heavier) steel sleeve cast or grouted Into floor or wail assembly. Sleeve may extend a max A. Studs - Wall framing may consist of either wood studs or steel channel studs. Wood studs to In. 406 mm ID (o 2 in. (51 mm) above top 1 floor or beyond either surface of wall. Max t I . ( ) (or smaller) min 0.028 (0.71 mm) wall thickness (or heavier) galvanized steel sleeve castor consist of nom 2 by 4 in. lumber spaced 16 in. OC with nom 2 by 4 In. lumber end plates and cross grouted Into floor or wall assembly. Sleeve may extend a max of 112 In. (13 mm) beyond either braces. Steel studs to be min 3 -5/8 In. wide by 1 -3/8 In. deep channels spaced max 24 In OC. surface of floor or wall. B. Gypsum Board* - Nom 1/2 or 5/8 in. thick, 4 R wide with square or tapered edges. The gypsum wallboard type, thickness, number of layers and sheet orientation shall be as specified In the individual 2. Through Penetrants0ne metallic pipe, conduit or tubing to be Installed either concentrically Wall or Partition Design. Diann of circular through opening to be 3/8 In. to 5/8 In. larger than outside or eccentrically within the firestop system. Max annular space between pipe, conduit or tubing and edge of through opening or sleeve Is dependent on the parameters shown In Rem diam of cable or cable bundle. 4. Min annular space between pipe or conduit and edge of through opening is 0 in. (0 mm) C. Fasteners - When wood stud framing Is employed gypsum wallboard layers attached to studs rigidly supported on both sides of floor or wall with cement coated nails as specified In the individual Wall or Partition Design. When steel channel stud (point contact). Pipe conduit or tubing to be ly pipes, conduits both tubing may used: framing Is employed, gypsum wallboard attached to studs with Type S self - drilling, self - tapping assembly. The following types and sizes of rigid bugle -head Steel strews as Specified In the individual Well Or Partition Design. A. Steel Pipe- Nom 30 In. (762 mm) diam (orsmaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe - Nom 30 In. (762 mm) diam (or smaller) cast or ductile Iron pipe. The hourly F Rating of the firestop system Is equal to the hourly fire rating of the wall e. Conduit- Nom 6 in. (152 mm) diam (or smaller) rigid steel condul[. assembly in which It Is Installed. D. Condult- Nom 41n. (102 mm) clam (or smaller) steel electrical metallic tubing. E. Copper- Tubing Nom 6 in. (152 mm) dram (or smaller) Type L ( or heavier) copper tube. F. Copper Pipe -Nam 6 In. (152 mm) dram (or smaller) Regular (or heavier) nipper pipe. 2. Cables - Individual table or max 1 In. diam Cable bundle Installed In through Opening with an annular space of min 0 In. (point contact) to max 3/4 in. Cable to be rigidly supported on both sides of 3. Packing Material Polyethylene backer rod or nom 1 In. (25 mm) thickness of tightly- packed Wall assembly. The following types and sizes of cables may be used: mineral wool batt or glass fiber Insulation firmly packed Into opening as a permanent form. Packing material to be recessed from top surface of floor or from both surfaces of wall A. Max 150 pair No. 24 AWG copper conductor telephone cable with polyvinyl chloride (PVC Insulation as required to accommodate the required thickness of caulk fill material (Item 4). and jacket materials. When max 25 pair telephone Cable Is Used, 4. FlII,Void or Cavity Material' - Caulk or SealApplled to fill the annular space flush with top surface of floor. In wall assemblies, required caulk thickness to be Installed symmetrically on T Rating Is 2 hr.When 50 to 150 pair telephone cable Is used In 1 hr fire rated wall, I 2 hr fir rated wall T both sides of wall, Rush with wall surface. At point contact location between penetrant and T Rating Is 3/4 hr.When 50 to 150 pair telephone cable Is used n e , sleeve or between penetrant and concrete, a min 1/4 in. (6 mm) diam bead of caulk shall be Rating Is 1 hr. applied at top surface of floor and at both surfaces of wall. The hourly F Ratings and the min required caulk thicknesses are dependent upon a number of parameters, as shown In the 10 AVIS multiple materialsPer conductor Type NM ( "ROmex ")nonmetallic sheathed cable with following table: PVC Insulation and Jacket Min Floor or Wall Thins In. (mm) Nom Pipe Tube or ondult clam In. (mm) Max Annular Space In. (mm) Min Caulk kns In. (mm: F Rating 2 -1/2 (64) 1/2.12 (13.305) 1 -3/8 (35) 1/2 (13) 2 2 -1/2 (64) 1/2 -12 (13.305) 3 -1/4 (83) 1 (25) 2 4 -1/2 (114) 1/2 -6 (13 -152) 1 -3/8 (35) 1/4 (6)(a) 2 4.1/2 (114) 1/2-12 (13 -305) 1 -1/4 (32) 1/2 (13) 3 4-1/2 (114) 1/2 -20 (13 -508) 2 (51) 1 (25) 3 4 -1/2 (114) 1/2 -20 (13 -508) 2 (51) 1 (25) 3 4 -1/2 (114) 1/2 -12 (13 -305) 3 -1/4 (83) 1 (25) 3 4 -1/2 (114) 22-30 (558 -762) 2 (51) 2 (51) 3 5 -1/2 (140) 1/2 -6 (13 -152) 1 -3/8 (35) 1 (25)(b) 4 When Type NM cable Is used, max T Rating is 1 -1/2 hr. C. Multiple fiber optical communication cable Jacketed with PVC and having a max outside diam of 5/8 in. When fiber optic cable is used, max T Rating Is 2 hr. D. Max 12 AWG multi conductor (max seven conductors) Dower /control cable with cross - linked polyethylene (XLPE) insulation and XLPE or PVC Jacket materials. When multi conductor power /control cable is used, max T Rating Is 2 hr. E. Max four conductor with ground No. 2 AWG (or smaller) aluminum SER cables with polyvinyl chloride insulation and Jacket materials. 3. FIII,Void or Cavity Materials* - Caulk, Sealant or Putty - Caulk or putty fill material Installed to completely nil annular space between cable and gypsum wallboard on both sides of wall and with a min 1/4 in. diam bead of caulk or putty applied to perimeter of cable(s) at its egress from each side of the wall. (a)Min 21n. (51 mm) thickness of mineral wool batt insulation required In annular space, (b)MIn 1 In. (25 mm) thickness of mineral wool batt Insulation required in annular space 3M COMPANY - MP+ Stix putty, CP 25WB+ caulk, FB -3000 Wi sealant or Cable Wrap putty on both sides of floor or wall assembly. Min 1 In. (25 mm) thickness of caulk to be Installed (Note: L Ratings apply only when CP 25WB+ caulk or FB -3000 WT sealant is used.) flush with each surface of floor or wall assembly. 3M COMPANY- CP 25WB+ caulk or FB -3000 WT sealant. (Note: W Rating applies only when *Bearing the UL Classification Mark FB -3000 WT sealant Is used.) •Bearing the UL Classification Marking * NOTE + NOTe THIS MATERIAL WAS EXTRACTED BY 3M FIRE PROTECTION PRODUCTS THIS MATERIAL WAS EXTRACTED BY 3M FIRE PROTECTION PRODUCTS FROM FROM THE 2011 EDITION OF THE UL FIRE RESISTANCE DIRECTORY. THE 2011 EDITION OF THE UL FIRE RESISTANCE DIRECTORY. NOTES \ \SGMWAII \DRAFTING \0D- 2D03W1 00 -2003 CAD DRAWINGS \SOUR( MMMI HOSPITAL (L(4SO S((E) \SMH ET BISTRO WAC 974270713 \PERNR AND DRAWINGS \CAD'S\SMH ET HEART RFMHM CENTER- 969498007.DWG DATE CREATED: November 21, 2013 DATE PLOT=: March 8, 2014 DATE SAVED: November 21, 2013 NOTES: 1. FIRE ALARM SYSTEM SHALL BE POWER LIMITED UTILIZING POWER LIMITED WIRING.. 2. WIRING SHALL BE #12 THHN, #14 THHN OR 18/2 TWISTED SHIELDED PAIR FPL TYPE CABLE. 3. INSTALLATION SHALL COMPLY WITH NFPA 1, 2009, APPLICABLE CHAPTERS. 4. INSTALLATION SHALL COMPLY WITH NFPA 72, 2007, APPLICABLE CHAPTERS. 5. INSTALLATION SHALL COMPLY WITH NFPA 101, 2009, APPLICABLE CHAPTERS. 6. INSTALLATION SHALL COMPLY WITH NEC 2008. 7. CONDUIT, AS APPLICABLE SHALL BE 1/2" MINIMUM WITH A MAXIMUM FILL OF 40 %. COMPLY WITH NEC. 8. SYSTEM SHALL BE GROUNDED PER MANUFACTURERS SPECIFICATIONS. 9. ALL DEVICES SHALL BE COMPATIBLE & SHALL BE UL LISTED FOR FIRE SERVICE USE. 10. ALL SPACES SHALL MEET THE AUDIBLE CHARACTRISTICS OF NFPA 72 AND NFPA 101. 11. SMOKE DETECTORS SHALL NOT BE LOCATED WITHIN 3' OF A/C DIFFUSERS, KITCHEN OR BATHROOM DOORS. 12. CEILING MOUNTED DEVICES SHALL BE LOCATED AT A HEIGHT OF 10' +/- ON SMOOTH FLAT CEILINGS UNLESS OTHERWISE NOTED. 13, SIGNALLING LINE CIRCUITS SHALL HAVE A MAXIMUM OF 127 POINTS PER CHANNEL. SEE FLOOR PLANS FOR QUANTITIES & TYPES OF DEVICES. 14. FIRE ALARM PANEL & ANY ASSOCIATED FIRE ALARM TRANSPONDERS SHALL BE FED BY A 120VAC, SINGLE PHASE, 20 AMP, DEDICATED BREAKER. 15. ALL INTERCONNECTED FIRE ALARM PANELS SHALL BE ARRANGED TO FUNCTION AS A SINGLE SYSTEM AND SHALL BE MONITORED FOR INTEGRITY PER NFPA 72. 16. RACKS, SHELVES AND EQUIPMENT ARE ALL LOWER THAN 80" ABOVE FINISHED FLOOR UNLESS OTHERWISE INDICATED. 17. THE DESIGN INSTALLATION COMPLIES WITH FLORIDA BUILDING CODE - 2010 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION. 18. THIS FACILITY IS FULLY SPRINKLED. 19. THIS IS A SEVEN STORY BUILDING. 20. ROOM CONTAINING FACP AND /OR BOOSTER POWER SUPPLY PANEL(S) IS MECHANICALLY VENTILATED. 21. MAXIMUM MOUNTING HEIGHT FOR ALL PANELS SHALL BE SIX FEET TO THE TOP OF THE ENCLOSURE. 22. MIMIMUM CLEAR WORKING SPACE OF THREE FEET IN FRONT OF ALL FIRE ALARM PANELS SHALL BE PROVIDED. SCOPE OF WORK: 1. PROVIDE & INSTALL FIRE ALARM SYSTEM AS SHOWN ON DRAWINGS. 2. SIGNALING LINE CIRCUIT WIRING SHALL BE STYLE 4. 3. NOTIFICATION APPLIANCE CIRCUIT WIRING SHALL BE STYLE Y. 4. THIS SYSTEM IS MONITORED BY AN EXISTING REMOTE SUPERVISORY STATION PER NFPA- 72.8.5. - - - - - - - - -- - - - - - - - - 5. ADD 2 TRIAMS TO CONTROL AND MONITOR 2 FIRE /SMOKE DAMPERS. SCOPE OF WORK FIRE ALARM SYSTEM SEQUENCE OF OPERATION TYPICAL: UPON ACTIVATION OF A MANUAL PULL STATION, ANY AUTOMATIC INITIATION DEVICE (i.e. Smoke or Heat detector). OR A FIRE SPRINKLER FLOW SWITCH THE FOLLOWING SEQUENCE OF EVENTS SHALL OCCUR: ALL AUDIO /VISUAL APPLIANCES, SPEAKERS AND STROBES WITHIN THE FLOOR WHERE THE ALARM INITIATED SHALL BE ACTIVATED. IN ADDITION, ALL AUDIOVISUAL APPLIANCES, SPEAKERS AND STROBES LOCATED ON THE FLOOR IMMEDIATELY ABOVE AND ON THE FLOOR IMMEDIATELY BELOW, SHALL ALSO BE ACTIVATED. ALL STROBES ACTIVATED UPON ALARM, WITHIN EACH SMOKE COMPARTMENT, SHALL BE SYNCHRONIZED. ALL MAGNETIC DOOR HOLDERS ASSOCIATED WITH THE DOORS LEADING INTO AND OUT OF THE SMOKE COMPARTMENT IN ALARM SHALL BE ACTIVATED TO RELEASE DOORS TO ISOLATE THE SMOKE COMPARTMENT WHERE THE ALARM INITIATED FROM. ALL AIR HANDLING UNITS AND FANS, SERVINGI THE SMOKE COMPARTMENT, FROM WHICH THE ALARM ORIGINATED FROM, SHALL BE SHUT DOWN PER NFPA 90 -A. ALL SMOKE DAMPERS ASSOCIATED WITH THE AIR CONDITIONING DUCTS PENETRATING THE RATED PARTITIONS ASSOCIATED WITH THE SMOKE COMPARTMENT WHERE THE ALARM IS ORIGINATED FROM, SHALL BE CLOSED. UPON ACTIVATION OF THE ELEVATOR LOBBY SMOKE DETECTORS (WITH THE EXCEPTION OF THE ELEVATOR LOBBY DETECTOR AT THE PRIMARY LEVEL OF EGRESS), THE FOLLOWING SHALL OCCUR IN ADDITION TO ABOVE: 1. ELEVATORS SHALL RECALL TO THE PRIMARY LEVEL OF EGRESS. 2. WARNING SIGN SHALL ILLUMINATE. UPON ACTIVATION OF THE ELEVATOR LOBBY SMOKE DETECTOR AT THE PRIMARY LEVEL OF EGRESS, THE FOLLOWING SHALL OCCUR, IN ADDITION TO ABOVE: 1. ELEVATORS SHALL RECALL TO THE ALTERNATE LEVEL OF EGRESS. 2. WARNING SIGN SHALL ILLUMINATE. UPON ACTIVATION OF THE ELEVATOR MACHINE ROOM SMOKE DETECTOR, THE FOLLOWING SHALL OCCUR, IN ADDITION TO THE ABOVE: 1. ELEVATORS SHALL RECALL TO THE PRIMARY LEVEL OF EGRESS. 2. WARNING SIGN SHALL BLINK. UPON ACTIVATION OF THE ELEVATOR TOP OF SHAFT SMOKE DETECTOR, THE FOLLOWING SHALL OCCUR: 1. ELEVATORS SHALL RECALL TO THE PRIMARY LEVEL OF EGRESS. 2. WARNING SIGN SHALL BLINK. UPON ACTIVATION OF A TAMPER SWITCH, THE FOLLOWING SHALL OCCUR. 1. A SUPERVISORY SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 2. A SUPERVISORY SIGNAL SHALL BE SENT TO THE OWNERS REMOTE STATION VIA DACT. UPON ACTIVATION OF A DUCT SMOKE DETECTOR, THE FOLLOWING SHALL OCCUR. 1. A SUPERVISORY SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 2. A SUPERVISORY SIGNAL SHALL BE SENT TO THE OWNERS REMOTE STATION VIA DACT. 3. THE AIR HANDLER UNIT ASSOCIATED WITH THAT DUCT DETECTOR SHALL SHUT DOWN. UPON ACTIVATION OF A ELEVATOR HEAT DETECTOR LOCATED IN THE SHAFT OR MACHINE ROOM THE FOLLOWING SHALL OCCUR. 1. A SUPERVISORY SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 2. A SUPERVISORY SIGNAL SHALL BE SENT TO THE OWNERS REMOTE STATION VIA DACT. 3. THE SIGNAL WILL BE SENT TO THE SHUNT SWITCH FOR POWER SHUTDOWN. UPON ACTIVATION OF A FIRE /SMOKE DAMPER MONITOR, THE FOLLOWING SHALL OCCUR. 1. REPORT STASIS OF FIRE /SMOKE DAMPER (OPEN OR CLOSE). SMOKE CONTROL SEQUENCE OF OPERATION THE AREAS COVERED UNDER THIS PROJECT ARE DESIGNED FOR A PASSIVE SMOKE CONTROL OPERATION. THE BUILDING IS DIVIDED INTO MULTIPLE SMOKE COMPARTMENTS SEPARATED BY FIRE /SMOKE BARRIERS THAT CONTAIN THE SMOKE WITH THE ZONE OF FIRE ORIGIN (ZOFO). UPON ACTIVATION OF ANY FIRE ALARM DEVICE THE FOLLOWING SEQUENCE OF OPERATION SHALL OCCUR: 1. ALL EXHAUST FANS SERVING THE ZOFO SHALL BE DE- ENERGIZED. 2. ALL AIR HANDLING UNITS SERVING ONE ZOFO SHALL BE DE- ENERGIZED. 3. ALL COMBINATION FIRE /SMOKE DAMPERS LOCATED 01`1 PERIMETER WALL OF ZOFO SHALL MODULATE TO THE CLOSE POSITION. NOTE: THE FOLLOWING EQUIPMENT SHALL BE PART OF THE SEQUENCE OF OPERATION DESCRIBED ABOVE: 1. TOILET EXHAUST FANS DEDICATED TO INDIVIDUAL TOILET ROOMS. 2. FAN COIL UNITS DEDICATED TO SERVE INDIVIDUAL ROOMS. SYMBOL LEGEND DEVICES REGISTRATION: SYMBOL SIMPLEX MODEL # DESCRIPTION NODE 7 - FACP 4100 -9111 NETWORK FIRE ALARM PANEL WITH VOICE & PHONES MINIPLEX 4100 -9600 NETWORK FIRE ALARM PANEL BASIC PANEL IRE PROTEC FATC 622 -5416 ADDR�� FIRE ALARM TERMINAL CABINET ��j 95OibE l i \$3>� r• u1Y �a Neil* M Beach, 59 • SIG FURNISHED BY ELECTRICAL CONTRACTOR _ MAAN, P.E. .S 4099 -9001 PULL STATION ADDRESSABLE O •'Q: F CV.. 0RIQ..•..� 2099 -9813 PULL STATION FLUSH TRIM SD 4098 -9792 SSD SENSOR BASE 4098 -9714 SSD PHOTO SENSOR SD 4098 -9792 SSD SENSOR BASE E 4098 -9714 SSD PHOTO SENSOR FOR ELEVATOR CAPTURE Z1 4090 -9001 INDIVIDUAL ADDRESS MODULE CONNECT TO N/O CONTACTS ONLY Z2 2190 -9161 NOTIFICATION APPLIANCE ZAM Z3 4090 -9002 RELAY IAM OCC -623 HEAT DETECTOR 135 FIXED E ELEVATOR SHUNT TRIP OPERATION O 4098 -9792 SSD SENSOR BASE 4098 -9733 SSD HEAT SENSOR SD 4098 -9756 SSD DUCTSENSOR HOUSING 2098 -9797 SAMPLING TUBE 49" OR 2098 -9806 REMOTE TEST STATION RED LED KEY SWITCH ® 4098 -9843 RELAY FORM C SPDT PAM -SD ® M 2088 -9032 RELAY SPDT W /LED MR -801/T FS FLOW DETECTOR SWITCH FURNISHED BY DIVISION 15 TS TAMPER (GATE VALVE) SWITCH FURNISHED BY DIVISION 15 �IVV- END OF LINE RESISTOR SM 4905 -9938 SMARTSYNC CONTROL MODULE 0.030 AMPS 75CD 4903 -9357 SPEAKER/STROBE75CD SYNC WALL MOUNT 0.199 AMPS S❑ 4902 -9703 SPEAKER WALL MOUNT 75CD ❑L 4904 -9332 STROBE 75CD SYNC WALL MOUNT 0.199 AMPS F 2084 -9001 FIREMAN'S PHONE JACK EWS EL -1 -SS ELEVATOR WARNING SIGN ® 2088 -9608 DOOR HOLDER CONNECTION TO AN APPROVED, DEDICATED EARTHGROUND, NFPA 70. COMPLY WITH NEC. -� 120VAC SOURCE DEDICATED BREAKER COMPLY WITH NFPA 70. ® MOTOR CONTROL CENTER BY OTHERS Plv PIV (GATE VALVE) SWITCH FURNISHED BY DIVISION 15 SD 4098 -9756 SSD DUCTSENSOR HOUSING, RETURN. R 2098 -9799 SAMPLING TUBE 97" SDS 4098 -9756 SSD DUCTSENSOR HOUSING, SUPPLY. 2098 -9799 SAMPLING TUBE 97" SDEH 4098 -9756 SSD DUCTSENSOR HOUSING, SUPPLY. 2098 -9799 SAMPLING TUBE 97" E EXISTING F FIELD LOCATED N NEW R RELOCATED W WATTS XXCD MC 4906 -9151 SPEAKER/STROBE MULTICANDELLA WALL RED 0.186 AMPS XXCD ❑L MC 4906 -9101 STROBE MULTICANDELLA WALL RED 0.186 AMPS WP S ET70 -WP SPEAKER/STROBE WEATHERPROOF, WALL, WHEELOCK 0.138 AMPS a 2099 -9138 WEATHERPROOF PULL STATION 1 N/0 SINGLE ACTION WP 2975 -9211 WEATHERPROOF RED BACK BOX © MB- GIO -24 -R MB MOTOR BELL INDOORS /OUTDOORS 0.040 AMPS ®- - •4OG9"9Q0+ --- - -HOW4CA+f6N AfaRLIA"E @+RCL*r-EX+FNDIR-R - - FSD Z7 4090 -9118 FIRE /SMOKE DAMPER FURNISHED BY OTHERS I TRAIM, CONTROUMONITOR ME T Tv SCOPE OF WORK VIIAW-OAD : F;M_ r D 5ELiPA1A1lR a: T `.i MI/ BLDG. EF : SUPPR 331 N Elf " PS DATii' '' Iv.O -'O. �CeixYFVpF. FIRE ALARM SYSTEM TO BE INSTALLED I1V ACCORDANCL•' WITH NFPA 72; 70;101 STATE: REGISTRATION: FLORIDA 59407 DISCIPLINE: PHONE: IRE PROTEC Vi 622 -5416 ADDR�� PC"lA ��j 95OibE l i \$3>� r• u1Y �a Neil* M Beach, 59 • SIG E AND SEAL _ MAAN, P.E. .S :� • .T' O •'Q: F CV.. 0RIQ..•..� LU .4 ^ �_ ^ Q J W 4 �- Im LL ^r4 ; -- \ Y Wo \ W C\I CL LO Z CMM� d C? tD "T LL M M h-• tT �� `� LIJ 1� V 02°'� U) p L0 w IL a LL U) O LIJ z U) � � a \ m J J ❑ wW z_w ERw V U) 1` F c� oa Z 0 F- Z j O � a (y) (U) 0 w W Z O m O ❑ � (n w > � m Ch < ¢ Of M CO U U M W ¢ N O ,� Z , t g I w I- U) , >_ U.1 i U O In Z U g o r, z v Of U)LL w H W ` LL N T 1 O J J W 0 Z � g a ww01 J M Z 4 L z❑ fn J O V a 0 W H F, (n �4 m W U tD iL 0. W = ¢ ¢ F- L) W U a L9 � O � W < CL di C3 W Q O O �- Z 0 Oz c) w ( r� Z w J Z d J J O L) Z Z �i w Z W o O E_-4 � 2 F- J r/l O V d O Z Co ¢ (n 0 ❑ 7 C7 Z0U) a �y IYi (H Q � U) Z W� 0o z❑ v�:j��Wyy x Z > za W OF' ❑ S W ZZ O 1r-I O 'a J D. Z 0L U1i -+-4 mrn ❑¢¢ �O DRAWN BY: DATE: CCRJR 11/21/21013 DESIGNED BY: DATE: CCRJR 11/21/2013 APPROVED BY: DATE: PROJECT NUMBER: 974270713 SHEET TITLE/ PATH: SHEET NUMBER: NOTESI SIZE D(24-x36-)