14-375R-014AIR COOLED SPLIT A/C UNIT SCHEDULE DESIGNATION : AC - 1A / CU - 1A LOCATION IT / DATA ROOM MANUFACTURER MITSUBISHI MODEL NUMBER MSZ -A09NA / MUZ- A09WNA CAPACITY - COOLING BTU /H 9000 POWER CONSUMPTION - COOLING W 690 SEER 17 COP - ELECTRICAL SERVICE AVAILABLE 115/1/60 MAXIMUM FUSE SIZE 15/15 MINIMUM CIRCUIT AMPACITY 1.0 / 12 FAN MOTOR (F.L.A.) 0.76 / 0.52 CONMPRESSOR R.L.A. / L.R.A. --- 1 9.3-47 AIRFLOW HIGH (Cl - -'150- 230 -300 -- MOISTURE (PT/ H) 2.7 SOUND LEVEL LOW -MED -HIGH / DB (A) _ 22 -33 -38 / 48 COND. DRAIN CONN.' O.D. (IN) W (IN) DIMENSIONS D (I N) H (IN) 5/8/- 31/31.5 8.25 f 11.25 11,75 f 21.625 REFRIGERANT WEIGHT (LB.) R-41 Oa 23178 NOTES: 1. ALTERNATE MANUFACTURES DAIKIN, FREIDRICH, CARRIER; MAY BE SUBMITTED FOR APPROVAL 2, THERMOSTAT MUST BE REMOTE WIRELESS TYPE BY THE UNIT MANUFACTURER. 3. UNIT MOUNTED DISCONNECT. 4, FACTORY CONTROL 5_ FACTORY MOUNTED KIT WITH CONDENSATE PUMP & CUT -OFF SW.. ( ") ARI RATINGS BASED ON OUTDOOR TEMPERATURES OF: SUMMER 80 DEGREES F. DRY BULB / 67 DEGREES F. WET BULB. WINTER: 70 DEGREES F. DRY BULB EXISTING AHU #I DATA (BEFORE DEMOLITION) AREA SERVED 6TH FLOOR LOCATION MECHANICAL ROOM AIR FLOW - CFM 23,520 OUTSIDE AIR - CFM 1,050 PRE - FILTER (PF) 30 % EFFICIENCY FINAL FILTER (FF) 95.1. EFFICIENCY SMOKE DETECTOR YES ON SUPPLY AND RETURN DUCT (EXISTING) EXISTING AHU # 1 DATA (AFTER NEW CONSTRUCTION) AREA SERVED 6TH FLOOR LOCATION MECHANICAL ROOM AIR FLOW - CFM 23,520 OUTSIDE AIR - CFM 1,335 PRE - FILTER (PF) 30 % EFFICIENCY FINAL FILTER (FF) 95 % EFFICIENCY SMOKE DETECTOR YES ON SUPPLY AND RETURN DUCT (EXISTING) NOTE: THE O/A MUST BE ADJUSTED TO OBTAIN 3,185 CFM AS SHOWN ON SCHEDULE AFTER NEW CONSTRUCTION IS FINISHED. EXISTING EF-G (BEFORE DEMOLITION) DATA AREA SERVED FIRST FLOOR LOCATION CEILING CFM 2,300 EXISTING EF -G AREA SERVED FIRST FLOOR LOCATION CEILING CFM 2,740 NOTE:. THE EXHAUST AIR MUST BE ADJUSTED TO OBTAIN 2,660 CFM AS SHOWN ON SCHEDULE AFTER THE NEW CONSTRUCTION IS FINISHED. AIR DISTRIBUTION SCHEDULE DUCT DESIGNATION A B C D E DIA METER MANUFACTURER TITUS TITUS TITUS TITUS TITUS 1" x 22 ga MODEL NO. AND/ OR 3.7 m ONE 2.75 nTn. 6.4 mm 25.4 X 0.85 mm ill'-18., 12' CATALOG NO, TDC-AA TDC-AA 50 F 50 F 300 FL 6.4 mm 25.4 X 0.85 mm LAY -IN 12' LAY IN 1/4" 1" x 22 ga 610 mm FRAME TYPE - SURFACE - SURFACE SURFACE TWO 8 ga. 3/8" 24 X 24 900 mrn 24 X 24 TWO 2.7 mm. 9.5 mm 25.4 X 1.00 mm 3711- 50" FIXED FIXED EGG CRATE EGG CRATE DOUBLE 3.7 m DEVICE TYPE ............. . .....� _. 51 " - 60" __ _ � TWO 3/8" TWO 1 " X 18 ga. LOUVERS LOUVERS 1/2 "� X 1/2 "' X 1/2 112" X 1/2" X 1/2 "' DEFECTION 61" - 84" FUNCTION SUPPLY SUPPLY RETURN RETURN / EXHAUST SUPPLY P12 = 193" UP PATTERN SEE DRAWING SEE DRAWING SEE DRAWING SEE DRAWING SEE DRAWING WEIGHT. IF HEAVIER DUCTS ARE TO BE INSTALLED, ADJUST HANGER SIZES TO BE WITHIN THEIR LOAD LIMITS. OPPOSED BLADE DAMPERS _ 180 1.0 � 55 85 1 230 TITUS DESV 302 VAV -602 2A NOTES: 1. ALTERNATE MANUFACTURERS, PRICE, METALAIRE 2. ALL AIR DEVICES SHALL BE ALL ALUMINUM CONSTRUCTION AND FULLY GASKETED, 3. UNLESS OTHERWISE NOTED, ALL AIR DEVICES FINISH SHALL BE BAKED OFF- WHITE. 4. FOR SQUARE NECK OUTLETS CONNECTED TO A ROUND FLEXIBLE OR RIGID DUCT, PROVIDE THE REQUIRED INSULATED SQUARE TO ROUND TRANSITION. MINIMUM HANGER SIZES FOR ROUND DUCTS DUCT MAXIMUM WIRE ROD STRAP DIA METER SPACING DIA METER STRAP WIRE/ROD 10 DN 12' ONE 12 ga. 1/4" 1" x 22 ga 250 mm DN 3.7 m ONE 2.75 nTn. 6.4 mm 25.4 X 0.85 mm ill'-18., 12' TWO 12 ga. OR ONES ga. 1/4" 1" x 22 ga 460 mm 3.7 m ONE 4.27 mm. 6.4 mm 25.4 X 0.85 mm 19" - 24" 12' TWO 10 ga. 1/4" 1" x 22 ga 610 mm 3.7 m TWO 3.51 mm. 6,4 mm 25.4 X 0.85 mm 25" - 36" 12' TWO 8 ga. 3/8" 1" x 20 ga 900 mrn 3.7 m TWO 2.7 mm. 9.5 mm 25.4 X 1.00 mm 3711- 50" 12' 1/2" TWO 3 /8" TWO 1" X 20 ga. 1270 mm 3.7 m CFM TWO 9.5 mm TWO 25.4 X 1.00 mm 51 " - 60" 12' 660 200 2000 TWO 3/8" TWO 1 " X 18 ga. 1520 mm 3.7 m 3/8" TWO 9.5 mm TWO 25.4 X 1.31 mm 61" - 84" 12' TITUS DESV 302 TWO 3 /8" TWO 1" X 16 ga. 2130 mm 3.7 m P12 = 193" UP TWO 9.5 mm TWO 25.4 X 1.61 mm NOTES: 1. STRAPS ARE GALVANIZED STEEL; RODS ARE UNCOATED OR GALVANIZED STEEL; WIRE IS BLACK ANNEALED, BRIGHT BASIC, OR GALVANIZED STEE-l. ALL ARE ALTERNATIVES. 2. TABLE ALLOWS FOR CONVENTIONAL WALL THICKNESS, AND JOINT SYSTEMS PLUS ONE LB /SF INSULATION WEIGHT. IF HEAVIER DUCTS ARE TO BE INSTALLED, ADJUST HANGER SIZES TO BE WITHIN THEIR LOAD LIMITS. HANGER SPACING MAY BEADJUSTED BY SPECIAL ANALYSIS. 0I eR;J. Nc. 24004 � ` � � ' • • • � CA 924 Y • � • Y r Y •'� •WY 4 4 Jc, • � LJUIS J« AGIIIRRF & kSSOCIATES P.A. �C hIGItL y ING tNGWEERS 21`50 SCI7TH D`AD `EL,4ND BLVa- Y Y SUITE 900 MIAMI, FLORIDA 33156 TEI EPHONIE- «,( 5) 670-X141 r�Y FAX ( }�)5) 670 -0 44 W wwvr1jaapas8m r W coo • uY••y EXISTING -VAV TERMINAL UNIT SCHEDULE MAXIMUM HALF OF PAIR AT 10 FT. SPACING PAIR ATE FT. SPACING PAIR AT5 FT, SPACING PAIR AT4 FT. SPACING HEATING COIL DATA STRAP WIRE/ROD STRAP WIRE/ROD STRAP CFM MIN STRAP WIREIROD P/2 = 30" 1" X 22 ga. SYMBOL SIZE DESIGN CFM 30% ASH RAE CFM MAX 1" X 22 ga. MANUF. MODEL SONES (10 (0.135) NOT REQUIRED (0.135) 1493 11 ", 12" H.P. (A =AMP W= WATTS) (2 ) 90.1-2007 1" X 18 ga. 3/8" NUMBER. 1/4" 1" X 22 ga. 1/4" 1" X 22 ga. 1/4" ENT. WATER 1" X 16 ga. EAT LAT HEATING 1" X 20 ga. 3/8" 1" X 22 ga. 1/4" P/2 = 120" 1 1/2" X 16 ga. 1/2" TEM P. GPM ( °F) ( °F) CFM 1/4" P/2 = 168" 1 1/2" X 16 ga. VAV' -602 -6 14 cp 660 200 2000 1/2" TITUS DESV 302 VAV- 602-4 14o 940 290 2000 3/8" TITUS DESV 342 VAV -602 -7 I 14o - -y 460 140 2000 - n. TITUS DESV 302 1" X 16 ga. 3/8" 1 1/2" X 16 ga. 3 /8" P12 = 193" UP SPECIAL ANALYSIS REQUIRED m ------ � NEW - V A V T E R M I N A L U N I T S C H ED U LE SINGLE HANGER MAXIMUM ALLOWABLE LOAD VAV 02 -1A 8 0 460 140 � 900 180 1.0 � 55 85 1 230 TITUS DESV 302 VAV -602 2A 100 680 205 1400 180 2.0 55 I 85 1 340 TITUS DESV 302 VAV- 602 -3A 10 680 205 1400 180 2.0 55 I 85 375 TITUS DESV 302 VAV- 602-4A _ loco _.......... __._._... 700 210 1400 _.__... 180 2 0 I 5 85 350 ! TITUS _ ( DESV 302 I REMARKS: 1, ALL UNITS TO BE PRESSURE INDEPENDENT NORMAL OPEN WITH ELECTRONIC CONTROL OPERATOR_ 2. ALL VARIABLE VOLUME BOXES SHALL BE DOUBLE WALL CONTRUCTION' WITH INSTALLED R- VALUE OF 3.5 MIN. INSULATION BETWEEN WALL 3. MAXIMUM NOISE CRITERION (25 NC), 4. MAXIMUM WATER PRESSURE DROP SHALL BE 5 FEET_ 5. DELTA WATER TEMPERATURE SHALL BE 20 °F, UNLESS OTHERWISE NOTED, 6. VV= VARIABLE VOLUME; CV= CONSTANT VOLUME. RECTANGULAR DUCT HANGERS MINIMUM SIZE MAXIMUM HALF OF PAIR AT 10 FT. SPACING PAIR ATE FT. SPACING PAIR AT5 FT, SPACING PAIR AT4 FT. SPACING DUCT PERIMETER STRAP WIRE/ROD STRAP WIRE/ROD STRAP WIREIROD STRAP WIREIROD P/2 = 30" 1" X 22 ga. ga.) 1" X 22 ga. C.F:M. 1" X 22 ga. 12 ga.) 1" X 22 ga. ga 26 ga. SONES (10 (0.135) NOT REQUIRED (0.135) 1493 11 ", 12" H.P. (A =AMP W= WATTS) (2 ) P12 = 72" 1" X 18 ga. 3/8" 1" X 20 ga. 1/4" 1" X 22 ga. 1/4" 1" X 22 ga. 1/4" P12 = 96" 1" X 16 ga. 3 /8" 1" X 1 I ga. 3/8" 1" X 20 ga. 3/8" 1" X 22 ga. 1/4" P/2 = 120" 1 1/2" X 16 ga. 1/2" 1" X 16 ga. 3/S" 1" X 18 ga. 3/8" 1" X 20 ga. 1/4" P/2 = 168" 1 1/2" X 16 ga. 1/2" 1 1/2" X 16 ga. 1/2" 1" X 16 ga. 3/8" 1" X 18 ga. 3/8" P12 = 192" NOT GIV EN 1/2" 1 1/2" X 16 ga. 1/2" 1" X 16 ga. 3/8" 1 1/2" X 16 ga. 3 /8" P12 = 193" UP SPECIAL ANALYSIS REQUIRED WHEN STRAPS ARE LAP JOINED USE 16 ga. D-20 SINGLE HANGER MAXIMUM ALLOWABLE LOAD THESE MINIMUM FASTENERS: D-26 C-26 STRAP WIRE OR ROD (DIA.) 1" X 18,20,22 ga. - TWO #10 OR ONE 1/4" BOLT 1" X 22 ga. - 260 Ibs. 0.106" - 80 Ibs. 1" X 16 ga. - TWO 1/4" DIA. BOLT 1" X 20 ga. - 320 Ibs. 0.135" - 120 Ibs. 1 1/2" X 16 ga. - TWO 3/8" DIA. BOLT 1" X 18 ga. - 420 Ibs. 0.162" - 160 Ibs. PLACE FASTENERS IN SERIES, NOT SIDE BY SIDE 1" X 16 ga. - 700 Ibs. 1/4" - 260 Ibs. E-20 F -18 F -18 G -16 NOT DESIGNED 1 1/2" X 16 ga. - 700 Ibs. 3/S" - 680 Ibs. D-26 E-24 E-24 F -22 G -20 H -20 H-18G 1­18G J -16H D-26 1/2" - 1250 Ibs. G26 C-26 5/8" - 2000 Ibs. D-26 D-26 3/4" - 3000 Ibs. NOTES: 1. DIMENSIONS OTHER THAN GAGES ARE IN INCHES. 2. TABLEALLOWS FOR DUCTWEIGHT, 1 Ib. /ft2 INSULATION WEIGHTAND NORMAL REINFORCEMENT AND TRAPEZE WEIGHT, BUT NO EXTERNAL LOADS. 3. STRAPS ARE GALVANIZED STEEL; OTHER MATERIALS ARE UNCOATED STEEL. 4. ALLOWABLE LOADS FOR P/2 ASSUME THAT DUCTS ARE 16 GA. MAXIMUM, EXCEPT THAT WHEN MAXIMUM DUCT DIMENSION (W) IS OVER 60" THAN P12 MAXIMUM IS 1.25 in. 5.12, 10, 8 ga. WIRE IS STEEL OF BLACK ANNEALED, BRIGHT BASIC, OR GALVANIZED TYPE. EXISTING F A N S C H E D U L E DESIGNATION E F -6 MANUFACTURER COOK 06 -04 -14 FAN TYPE CENTRIFUGAL CODE MODEL NUMBER 20CVR NO. LOCATION ROOF 0 AREA SERVED GENERAL EXHAUST 1 5' C.F:M. 3000 2 -1/2' E.S.P. (INCHES OF WATER) 2.5 26 ga. SONES - NOT REQUIRED R.P,M. 1493 11 ", 12" H.P. (A =AMP W= WATTS) 3 B -26 VOLT - PH - HZ 208/3/60 B -26 DRIVE BELT B -26 BACKDRAFT DAMPER YES WALL / ROOF OPENING - INCHES B-26 INTERLOCK B -26 B-26 REMARKS: 1V[0j)j1�IC ,&TIONS ONLY INTERIOR VIBE (ANY E;�'CFlUOEL N10DIC[CATIONC )Y RE4 A BfJARD AIP�AFtA r 2 1 S Revisions: RECTANGULAR DUCT REINFORCEMENT END USER 2" W.G. STATIC POS. OR NEG. NO REINFORCEMENT REQUIRED 06 -04 -14 REINFORCEMENT END USER CODE FOR DUCT GAGE NO. L REINFORCEMENT SPACING OPTIONS 0 DUCT DIM. 10' 8' 6' 1 5' 1 4' 1 3' 2 -1/2' 2' 10" dn. 26 ga. NOT REQUIRED 11 ", 12" 24 ga. B -26 B-26 B -26 B -26 B -26 B -26 B -26 13 ", 14" 22 ga. B -24 B-26 B -26 B -26 B-26 B -26 B -26 15 ", 16" 20 ga. C-22 C-24 C-24 G-26 C-26 C-26 B -26 B -26 17 ", 18" 20 ga. C-22 G24 C-24 C-26 C-26 C-26 C-26 B -26 19 ", 20" 18 ga. C-20 C-22 C-24 C-26 G26 G26 C-26 C-26 2111,2211 16 ga. D-20 D-22 D-24 D-26 C-26 G26 G26 C-26 2311,2411 16 ga, E-20 E-22 D-24 D-26 D-26 C-26 C-26 C-26 25 ", 26" E-20 F -18 F -18 G -16 NOT DESIGNED E 22 E-20 F -20 G -18 H -16 1 -16 E-24 E 22 E22 F -20 G -18 H-18 1 -16G I -16G D-26 E-24 E-24 F -22 G -20 H -20 H-18G 1­18G J -16H D-26 C-26 G26 C-26 2711,2811 D-26 D-26 G26 G26 29 ", 30" E 26 D-26 D-26 C-26 3111-3611 E 24 E-26 D-26 D-26 3711-42" F -24 E-24 E26 E-26 4311-4811 G -22 F -24 F -24 E-24 49" - 54" K20G G -24 F -24 F -24 5511-6011 H -18G G -22 G -24 F -24 61" - 72" 1 -18G H -22G H -22G H -24 7311-8411 1 -18G 1 -20G 1 -22G 1 -22G 85" - 96" J -18H 1 -18H 1 -20H 1 -22H 97" - 108" K -18H J -18H 1 -15H 10911- 120" K -181 J-181 r 2 1 S Revisions: END USER REQUEST 06 -04 -14 END USER 2 REQUEST Oi -27 -14 L 0 oN �Ln H o 0 te F- 1 W V u w c LLM O , H Ind x O gov � r pill� v� p � � 4 d �o °coa,n; . ^1 E O �V -N PC hi V V) V Q 3 V V) CONSTRUCTION DOCUMENTS DRAWN: JB CHECKED: E5 DATE: 03-12-14 SCALE: AS SHOUIN r SEAL , . - * If, x3 r \o'y 7C IA IC L k LEST S'AN7ANA P.E. LICE E"`x 60788 Sheet No. M6.00 JOB t