Loading...
14-375R-011L f 5T OF EOIJ I F1- IENT, 5 `r5TEM5, AFFL I ANCE 5, AND INTERIOR WINDOW DETAILS ITEM PROVIDED INSTALLED REMARKS 1 TOILET MIRRORS - AT PATIENT TOILET USE LARGE DECORATIVE MIRROR ACROSS THE BACK WALL. AT STAFF TOILETS USE 505RIC SS. SM 30" X 18 ". CONTRACTOR CONTRACTOR MAT. 2. CUBICLE CABINETS - ACROSS THE BACK. CONTRACTOR CONTRACTOR CzLAZINCz 3. 504F DISPENSERS OWNER CONTRACTOR PLASTIC / AT ALL AREAS. 4. PAPER TOWEL DISPENSERS AND WASTE RECEPTACLE. CONTRACTOR CONTRACTOR PUBLIC TOILET/METAL /RECE55ED 5. TOILET PAPER DISPENSERS CONTRACTOR CONTRACTOR SS / RECESSED ALL AREAS. (o. SURFACE- MOUNTED SEAT COVER DISPENSER (505RICK 5 -221) CONTRACTOR CONTRACTOR METAL / AT ALL AREAS. 1. GARBAGE CANS OWNER OWNER RU55ER -1 S. CUBICLES /EXAM /TRIAGE SHARPS DISPOSAL BOX OWNER CONTRACTOR > CAULK (TYP ) 'B. CUBICLES /EXAM /TRIAGE SOAP DISPENSER OWNER CONTRACTOR V.0 -T- 10. CUBICLES /EXAM /TRIAGE HAND SANITIZER OWNER CONTRACTOR ACOUSTICAL CEILING 11., CUBICLE CURTAINS OWNER OWNER I 1 12. CURTAIN TRACKS OWNER OWNER CONTRACTOR COORDINATED. 13. SLAM EQUIPMENT (SPHYGANOMANOMETER SET). OWNER CONTRACTOR 606 14. GLOVES DISPENSER OWNER CONTRACTOR STANDARD STEEL 15. STAINLESS STEEL CARTS WITH WHEELS OWNER OWNER 1(o. CARD READERS AND CARD READER SYSTEM OWNER OWNER CONTRACTOR COORDINATED. 1D. NURSE CALL SYSTEM CONTRACTOR CONTRACTOR CONTRACTOR COORDINATED. IS, COPIERS OWNER OWNER OWNER - PROVIDE SPECS. 19. FAX OWNER OWNER OWNER - PROVIDE SPECS. 20. SAFE OWNER CONTRACTOR OWNER - PROVIDE SPECS. 21.1 SHREDDER OWNE}z OWNER OWNER - PROVIDE SPECS. 22- SOUND SYSTEM OWNER OWNER PER TELECOM / IT SPECS. 23. SIGNAGE OWNER OWNER - 24. EVACUATION PLANS OWNER CONTRACTOR ARCHITECT TO PREPARE. 25. FILTERED WATER DISPENSING UNITS OWNER OWNER VALVE TO BE INSTALLED BY CONTRACTOR 2(o WATER COOLERS CONTRACTOR CONTRACTOR 5EE SHEET A -2 21. REFRIGERATORS OWNER OWNER CONTRACTOR COORDINATED. 28. NOT USED A.C.T 1 8' -0' 2S. FIRE EXTINGUISHER CONTRACTOR CONTRACTOR RU15BER -1 30, NOT USED CONTRACTOR CONTRACTOR 8' -0' 31. JANITOR'S SLOP SINK - PRE -FAB. CONTRACTOR CONTRACTOR P. TILE 32. CAMERA / SECURITY SYSTEM OWNER OWNER CONTRACTOR COORDINATED. 33 TV /TV BRACKETS OWNER OWNER / VENDOR TX ROOM No. 6 34 UNDER COUNTER REFRIGERATOR OWNER OWNER CONTRACTOR COORDINATED. 35 EYE WASH UNITS CONTRACTOR CONTRACTOR ADDED TO FAUCETS, SEE PLAN 3(o METAL LOCKERS OWNER OWNER / VENDOR CONTRACTOR COORDINATED. 3 -1. NOT USED - - 38 RECEPTION COUNTER CONTRACTOR CONTRACTOR RU55ER -1 39 NOT USED - - 8' -0" 40. NOT USED _ TX ROOM No. -1 2 V.C.T. 41. GREEN MARBLE TOPS FOR TOPS WHERE SPECIFIED, CONTRACTOR CONTRACTOR A.C.T -1 42. PEG BOARD FOR CRUTCHES 4 OTHER EQUIPMENT. CONTRACTOR CONTRACTOR PAINT TO MATCH WALL COLOR 43 PAPER TOWEL DISPENSER 8 -262, CONTRACTOR CONTRACTOR STAFF TOILET t OTHER AREAS/ SURFACE MOUNTED/ S. STE 44 NOT USED - 620 45 HORIZONTAL WALL - MOUNTED / RECESSED - MOUNTED STAINLESS STEEL BABY CHANGE STATION. CONTRACTOR CONTRACTOR PUBLIC - A.G.t -1 8' -0' 621 L C- . R1r155ER -1 - - - A.C.T -1 8' -0" . ..- i • iifi• Uvu i•ii ii• i U �' GCG Y= • 4 l:4 ••V 1 • U Y r Y , W tY � 4 Y ' fu• fu• FlNle� S Goo • v 6 4 i i INTERIOR WINDOW DETAILS ROOM NO. SCHEDULED FINISH 2 , FLOOR ON '• %' GYPSUM 1 4LLOW 1 WALLS WALLBOARD GAULK METAL FRAME CEILING CONT'S STANDARD STEEL MAT. I -ICxT. MAT. HCT. 1,408 CzLAZINCz WAITING ROOM GASKET P.TILI =/TRIM CONT'S METAL /GLASS w LEAD SHIELDED. I, 3 ,.. DOUBLE 5is' 602 METAL STUDS - (20 CzASE) TYP. METAL CLASS - STOP TYPICAL �4 JAMB DETAIL (SILL SIMILAR) N.T.S. SCHEDULED FINISH ON 5is" GYPSUM WALLBOARD RECEPTION 5is' METAL STUDS RU55ER -1 w (20 GAGE) TYP. IV i/2 " > CAULK (TYP ) ALL FOUR SIDES 604 cv HOLLOW METAL FRAME V.0 -T- STANDARD STEEL ON TE5: I- WITH 1/4' CLEAR TEMPERED GLASS. 2- FOR COLOR 5EE INTERIOR DESIGN SHEETS. 1 3- SEE LEAD SHIELDING REPORT FOR GLAZING REQUIREMENTS. SUSPENDED - ACOUSTICAL CEILING �' -2' METAL GLASS 5TOP EQUAL EQUAL I 1 Iii' CLEAR TEMPERED GLASS RUBBER -1 HEAD DETAIL 1 SILL SIMILAR N.T.S. SCHEDULED FINISH ON DRYWALL METAL STUD 606 CAULK (TYP. EACH SIDE) HOLLOW METAL FRAME STANDARD STEEL I" x PT. WOOD IBLOCKING - 607 GLAZING LEAD SHIELDING SEE SHEET A -2 608 FOR THICKNESS LINE OF CERAMIC TILE WHEN OCCURS c D WINDOW JAMS /HEAD DETAIL N.T.S. -� GLAZING TX ROOM No. 2 LEAD SHIELDING RUBBER -I SEE SHEET A -2 - - FOR THICKNE55 A.G. -1 8' -0" 2 HOLLOW METAL FRAME 610 - STANDARD STEEL V.C.T. I" x PT_ WOOD IBLOCKING PAINT j CAULK (TYP. EACH 51DE) - TILE WHEN V-0' OCCURS LINE OF CERAMIC l4 7 METAL STUDS (211 TX ROOM No. 4 SCHEDULED FINISH ON RUBBER -I DRYWALL - - - A.C. -1 LEAD SHIELDING 5EE SHEET A -2 612 FOR THICKNE55 E WINDOW 5ILL DETAIL N.T.S. . ..- i • iifi• Uvu i•ii ii• i U �' GCG Y= • 4 l:4 ••V 1 • U Y r Y , W tY � 4 Y ' fu• fu• FlNle� S Goo • v 6 4 i i FLR- ROOM NO. ROOM NAME FLOOR BASE 1 WALLS WAINSCOT CEILING y v - �W. °•` ••Y v�" REMARKS • • • Y �. u • MAT. I -ICxT. MAT. HCT. 1,408 601 WAITING ROOM P. TILE P.TILI =/TRIM HINT METAL /GLASS LEAD SHIELDED. I, 3 602 NOT USED - - - - - - - I Dotty • wo•aU U Yvu u .. .. .. 603 RECEPTION V -G -T, RU55ER -1 PAINT 604 CHECK OUT CUBICL 1 4 2 V.0 -T- RUBBER -1 ON TE5: I- WITH 1/4' CLEAR TEMPERED GLASS. 2- FOR COLOR 5EE INTERIOR DESIGN SHEETS. 1 3- SEE LEAD SHIELDING REPORT FOR GLAZING REQUIREMENTS. - - - G.WB �' -2' 605 I 1 V.C.T. RUBBER -1 PAINT 606 AVE LCO - - - - 607 608 STORAGE No. 1 - - w - - 609 TX ROOM No. 2 V.C.T. RUBBER -I PAINT - - - A.G. -1 8' -0" 2 610 TX ROOM No. 3 V.C.T. RUBBER -1 PAINT - - - A.G. -1 V-0' (211 TX ROOM No. 4 V.C.T. RUBBER -I PAINT - - - A.C. -1 V- 0' 612 TX ROOM No. 5 V.C.T. RU55ER -1 PAINT - - - A.C.T 1 8' -0' 613 CORRIDOR No. 2 V.G.T. RU15BER -1 AI w - - A.G. -1 8' -0' 614 TOILET ROOM P. TILE P. TILE P. TILE - - - A.C.T -1 8' -0" 615 TX ROOM No. 6 V.G.T. W513ER -1 - - - A.C. 1 S' -0' 616 v.C.T. RU55ER -1 PAINT - - - A.G. -1 8' -0' 61'1 TX ROOM No. 1 A V.C.T. RU55ER -1 PAINT i - - - A.C.T -1 8' -0" 618 TX ROOM No. -1 2 V.C.T. RUBBER -1 PAINT - - - A.C.T -1 8' -0' 619 RUBBER -1 - - - A.G. -1 V-0' 620 DOCTOR'S WORK AREA CARPET RU55ER -1 PAINT - - - A.G.t -1 8' -0' 621 L C- . R1r155ER -1 - - - A.C.T -1 8' -0" 622 JANITOR A Q.T. Q.T. Q.T. 5' -0' EXPO - *ON TWO WALLS ONLY -SEE INTERIOR ELEVATIONS 623 STAN TOILET 1 P. TILE I P. TILE P. TILE - - - A.C.T -1 8' -0" 624 X -RAY ROOM V.C.T. R5 -1 - - - A -G- -1 8' -10' 625 STORAGE No_ 2 A V.G.T. RIB-1 PAINT - - - A.G. -1 2 26 I V.G.T. R5-1 PAINT 1 - - - A.C.T -1 8' -0' 621 MEDICATION ROOM R5-1 - - - A_C.T -1 8' -0' 628 CLINICAL WORK AREA V.C.T. RB -1 PAINT - - - A.C. -1 8' -0' 629 SUPERVISOR'S OFFICE R5 -1 I - - - A.C.t -1 8' -0' O 630 P - - C - 8' -0' U 631 NOT USED - - - - - - - - � 2 x 1 P. TILE - PORCELAIN TILE M.T. - MOSAIC TILE ACT I ° ARMSTRONG CIRRUS 500 Q T. = QUARRY TILE C. TILE = CERAMIC TILE A.C.T. - ACOUSTICAL CEILING TILE ACT 2 - ARMSTRONG DUNE 1772 A.C.T. /S - ACOUSTICAL CEILING AND SOFFIT WD. = WOOD EXP.= EXPOSED VINYL I - PROFILE RB = RUBBER BASE V.C,T. =VINYL COMPOSITION TILE CONC.= CONCRETE VINYL 2 - STRAIGHT PCT = PORCELAIN TILE. VINYL = HEET VINYL W.C. = WALL COVERING GWB. - GYPSUM WALL BOARD FlNle� S NOTEE5 - FOR INTERIOR DESIGN PATTERNS AND DETAILS, SEE FINISH SCHEDULE BY INTERIOR DESIGNER. IF THERE IS A DISCREPANCY BETWEEN THE I.D. SCHEDULE is THIS SCHEDULE THE I.D. SCHEDULE SUPERSEDES. CONTRACTOR MUST NOTIFY ARCHITECT OF DISCREPANCY. - MINIMUM INTERIOR FINISHES CLASSIFICATION CATEGORY SHALL BED - CLASS A OR CLASS B IN EXITS AND CORRIDORS TO EXIT. • CLASS A, CLASS B, OR CLASS C, IN OFFICE AREAS. - FOR DETAILS ON FINISHES, SEE INTERIOR DESIGN DRAWINGS. INTERIOR WINDOW SCHEDULE MARK DESCRIPTION SIZE MATERIAL AREA REMARKS H FIXED z' -a' 3' -5' METAL/ GLASS 1,408 1,2 FIXED 3' -8" 3' -8" METAL /GLASS LEAD SHIELDED. I, 3 7,3 ON TE5: I- WITH 1/4' CLEAR TEMPERED GLASS. 2- FOR COLOR 5EE INTERIOR DESIGN SHEETS. 1 3- SEE LEAD SHIELDING REPORT FOR GLAZING REQUIREMENTS. WINDOW ELEVATIONS w -2 FIN. FL. —1 LEAD SHIELDED INTERIOR MODIFICATIONS ONLY (ANY E7�[ERIOR MODI'rICAT[ON MAY pEQUIRE A j%OARD A�"I'EARA'�CE) c p � r• a. • 1 Revisions: AOro - 04 -14 END USER REQUEST ZL08- 2-1 -14 END USER REQUEST A 0 0 44 rn N M� a 0 x h W � x V O O 0� h O � W �N M N N h rH +� M r O � x E 0 -f■r V .Weg � •." Q � 118 iw 0 01 ft W A� W xw V A V) V) Z z LLj 00 O z a CONSTRUCTION DOCUMENTS DRAWN: C=AC CHECKEDa LEN DATE: 03-12-14 SCALE: AS SHOWN I SEAI::?, - -sir E '-� s :'4& �s rE� PSI- Sheet No. A -10 OF 17 JOd # 201335 I i