Loading...
14-375-034TX ROOM TX ROOM TX ROOM TX ROOM NO. 3 NO. 4 NO. 5 NO. 2 _..... _ - r __ 610 L-. 6.11 812 176-0-91 STAFF TOILET TX ROOM © Q • • 614 • � ON NO. 6 N N N N N 615 �' -- - - - - -� - - - -_- _ I'---- NEW 1 1/2" -- -ti �% rr - - - - -- E E - - - -- 2 1/2" - - -- -- �----------------------- -- ---- - - -- ------------------------ - E 2 1/2" i i i i i i i i i i i STORAGE O Q N Q CORRIDOR 0• O 608 N N c\1 N 613— N N I O � N I I O ' ----------------------------- 1.. N - rrr NEWS 1/2_'_ NEW 1 1/4" �L_ 1 - r r r r r r r r r. r r r r r r r _ _ _ _ _ _ _ _ _ _ _ _ —. ..—.— _ _ _ _ _ _ _ _ _ _ _ E E i E -- , E i STORAGE ' � WORK AREA 631 Q• N i 630 • QN TX ROOM F�vi ON O•N •N N NO. 1 WORK ROOM CHECK OUT SUPERVISOR'S 607 N CUBICLE 629 OFFICE CORRIDOR , `04 62a 805 � r 1 NEW 1 1/4" 1 . -------------------------- 1— - -- rrr rrrrrrr -- - - ---- ��__----------------------------- „ ��J.�, � u E E 1,. E RECEPTION 1 E QN i O 603 i i i N I VENDING IT /MEDIA •O 606 N N - 602 ©N L_. � �I N� I I I I I i 1 1/4" 1 1/4" 1 1/4" --------- - - - - -- '� _------------ - - - - -- �'�i -- ------ - - - - -� ,: - - - -- - - - - - --< ELECTRICAL E WAITING E E ROOM ROOM i 0• _._ Q O �T110 N 801 i •N •N i i i i i i i i i i CORRIDOR FT ------------ - - - -�- O N IEDICAL i ROOM I I s27 I I O N I i i I E w z CAST ROOM STEEL PIPE SIZE (IN) ONE HOUR FIRE RATED WALL OR 1 + —616 ON 11/4 TX ROOM ■ ■1 ■1 Ir■ EAII ■ (0 2 NO. 7 TWO HOUR FIRE /SMOKE RATED ■■■ ■!� �■ ! WALL OR PARTITION WAITING 61!! STRUCTURE FOR SECURITY REASONS DRYWALL BOTH SIDES - NOT RATED 617 N y N \ 21/2" E 21/2" E 1/2" - -�i i i i i i i - -- _ - - -2 - - - - - - - - - - - -- - - - - -- i I i i i N i N N , i i i i i STO i �� 625... -- O tCORRIDOR CLINICAL N 9 X-RAY O WORK 624 N CONTROL •O i Q• X26 � QN N � E E / STAFF TOILET 623 �N ("���*N E 1 1/4" 1 1/4" --------------------------- � --- -µ------------ - - ---- - - - - -- - _ - - -_ - - - -� E E JANITOR N 622 STAFF LOUNGE N 621 O N FLCOF,., FLAN = FIF.,,F Ff;;:�CTECTICN SCALE: 1/4'' = 1'-0" GENERAL NOTES 1. EXISTING BUILDING IS FULLY SPRINKLERED. CONTRACTOR IS TO RELOCATE / OFFSET EXISTING MAINS AND BRANCH PIPING AS REQUIRED TO CONNECT TO NEW SPRINKLER HEADS SHOWN ON THIS SHEET IN COORDINATION WITH THE EXISTING AND NEW SYSTEMS, DUCTWORK, ECT. LOCATED IN THE PLENUM. 2. NEW ARMOVERS SHALL BE IN ACCORDANCE WITH THE DETAILS ON SHEET FP7.00. 3. ALL SPRIKLERS SHALL BE NEW AND SPRINKLER HEADS NOT USED SHALL BE CAPPED OFF. CONCEPTUAL DESIGN ONLY FIRE PROTECTION CONTRACTOR'S WORKING PLANS AS PER NFPA 13 MUST BE SUBMITTED TO AND APPROVED BY THE AUTHORITY HAVING JURISDICTION BEFORE ANY FIRE PROTECTION SYSTEM IS INSTALLED OR REMODELED. FLOOR PLAN LEGEND STEEL PIPE SIZE (IN) ONE HOUR FIRE RATED WALL OR 1 PARTITION (SEE PARTITION TYPES) 11/4 ONE HOUR FIRE /SMOKE RATED ■ ■1 ■1 Ir■ EAII ■ WALL OR PARTITION 2 (SEE PARTITION TYPES) TWO HOUR FIRE /SMOKE RATED ■■■ ■!� �■ ! WALL OR PARTITION (SEE PARTITION TYPES) PARTITION TO UNDERSIDE OF STRUCTURE FOR SECURITY REASONS DRYWALL BOTH SIDES - NOT RATED NORTH PIPE SIZING PROCEDURES NOTE: CONTRACTOR IS TO FIELD VERIFY THE EXISTING PIPE SIZES AND SHALL REPLACE ANY PIPING AS REQUIRED TO COMPLY WITH NFPA 13 SECTION 1122 "PIPE SHEDULE METHOD ". REFER TO TABLE 14.5.2.2.1 BELOW. WHERE THE " PIPE SCHEDULE METHOD" WILL NOT BE USED, CONTRACTOR IS TO PERFORM HYDRAULIC CALCULATIONS PER NFPA SECTION 11.2.3 " HYDRAULIC CALCULATION METHODS ", NFPA 13 (2002) Table 14.5.2.2.1 LIGHT HAZARD PIPE SCHEDULES STEEL PIPE SIZE (IN) # OF SPRINKLERS 1 1 -2 11/4 3 11/2 4 -5 2 6 -10 PV( ,Nc 24 )4 924 i • u � • � u u • • • iii • W i • • • u h 6 LOUIS &- AGUIRRE b, ASSOCIATES P.A. 'C0M8ULYIwG ENWNEfHS 9150 00TH LADLL'A% Z. SITE 900 MIAMI, FLORIDA 33156 TEI[,p ENE: (305) 670 -0141 •i•. FAk:,�,° (305)�b70 -6144 • wwwdjcaL,C.com„• 4 y Kn t) xv,, .�'.7N', Xv >k A. a _ ,:. OUTPATMW XWGERY �r ... rAR�IG�� l: - ............. GARAGE ..ji ...._; J. 11 ARTS BULDIM! l if Revisions: L 0 A 0 u 0 IV H H 0� ca �x � g� s G� 0 � O V O t� 0 C� O Q a tom. C4 CONSTRUCTION DOCUMENTS DRAWN: JB CHECKED: ES DATE: 03-12-14 SCALE: y45 SHOWN SEAL-` 44 n �.' J. is 4 wr. EC3l"J�I�(�0 A ,S`LJAf�tLZ' P.E 9 ,~f SE %'64753 Sheet No. FP3.01 IJOIS * 201335 I x4