Loading...
14-375-025MOUNTING ANGLES FASTENED TO SLEEVE AT 6" O.C. (MIN. 2 CONNECTIONS ON EACH SIDE) VVV 1 114" CLEARANCE PER FOOT ALL AROUND BREAKAWAY CONNECTION - ANGLE SIZE E SLEEVE AS PER SMACNA STANDARDS TYPE "B" FIRE DAMPER W/ UL RATING E STAMP DUCT MANUFACTURERS SLEEVE u u FULLY HINGED GASKETED ACCESS DOOR IN DUCT - L i 14" X 14" UNLESS NOTED 6" MAX. ON ALL SIDES OTHERWISE- LABEL "FIRE DAMPER' EXTERNAL INSULATION TO NOTE: EXTEND OVER SLEEVE ALL ACCESS DOOR SHALL BE LOCATED ON SIDE OR BOTTOM OF AROUND AFTER INSPECTION OF DUCT AS APPROPRIATE TO PERMIT RESETTING OF DAMPER LINK, DAMPER INSTALLATION 2, INSTALL FIRE DAMPERS IN STRICT ACCORDANCE WITH MANUFACTURERS UL LISTED INSTALLATION INSTRUCTIONS. FIRE DAMPER DETAIL NTS FRAME 1 HINGE POS. 1 LOCK TYPE 1 SASH LOCK M e.[ It .Trl'l ^""JEL ACCESS DOOR DETAIL N.T.S. y CERAMIC FIBER BLANKET FRAME 2 HINGE POS. 2 FRAME 3 HINGE POS. 3 SYSTEM NO. W- L- -7178 F RATINGS - 1 AND 2 NR (SEE ITEM U T RATING - 3/4 HR L RATING AT AMBIENT - LESS THAN I CFM /SQ FT L RATING AT 400 F - LESS THAN I CFM /SQ FT CCU IUIN H —H NOTES: I. WALL ASSEMBLY . THE I OR 2 HR FIRE -RATED GYPSUM BOARD /STEEL STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN, THE MANNER DESCRIBED IN THE INDIVIDUAL U400 OR V400 SERIES WALL AND PARTITION DESIGN IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: A. A. STUDS. WALL FRAMING SHALL CONSIST OF MIN 3 -1/2 IN. (89 MM) WIDE STEEL CHANNEL STUDS SPACED MAX 24 IN. (610 MM) OC. - ADDITIONAL STEEL STUDS SHALL BE USED TO COMPLETELY FRAME THE OPENING. B. B. GYPSUM BOARD* - 5/8 IN. (16 MM) THICK, 4 FT (1.22 M) WIDE WITH SQUARE OR TAPERED EDGES. THE GYPSUM BOARD TYPE, THICKNESS, NUMBER OF LAYERS, FASTENER TYPE AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE INDIVIDUAL U400 OR V400 SERIES DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY. MAX AREA OF OPENING IS 540 SO IN, (0.35 M2) WITH A MAX DIM OF 30 IN. (762 MM). THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS EQUAL TO THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED. 2. STEEL DUCT - MAX 24 BY 12 IN. (610 BY 305 MM) NO. 26 GAUGE (OR HEAVIER) STEEL DUCT TO BE INSTALLED WITHIN THE FRAMED OPENING. MIN CLEARANCE BETWEEN DUCT AND EDGE OF FRAMED OPENING IN WALL IS 3 IN. (76 MM). STEEL DUCT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF THE WALL ASSEMBLY. 3. BATTS AND BLANKETS* -NOM 2 IN, (51 MM) THICK LIGHT DENSITY (MIN 3/4 PCF OR 12 KG /M3) GLASS FIBER BLANKET INSULATION JACKETED ON THE OUTSIDE WITH A FOIL -SCRIM -KRAFT FACING. LONGITUDINAL AND TRANSVERSE JOINTS SEALED WITH FOIL- SCRIM -KRAFT TAPE. NOM ANNULAR SPACE BETWEEN INSULATED STEEL DUCT AND PERIPHERY OF OPENING TO BE I IN. (25 MM). SEE BATTS AND BLANKETS (BKNV) CATEGORY IN THE BUILDING MATERIALS DIRECTORY FOR NAMES OF MANUFACTURERS, ANY BATT OR BLANKET MEETING THE ABOVE SPECIFICATIONS AND BEARING THE UL CLASSIFICATION MARKING WITH A FLAME SPREAD VALUE OF 25 OR LESS AND A SMOKE DEVELOPED VALUE OF 50 OR LESS MAY BE USED. 4. FIRESTOP SYSTEM - THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING: A. PACKING MATERIAL - (OPTIONAL, NOT SHOWN) - POLYETHYLENE BACKER ROD, MINERAL WOOL BATT INSULATION OR FIBERGLASS BATT INSULATION FRICTION FITTED INTO ANNULAR SPACE. PACKING MATERIAL TO BE RECESSED FROM BOTH SURFACES OF WALL AS REQUIRED TO ACCOMMODATE THE REQUIRED THICKNESS OF FILL MATERIAL. B. FILL, VOID OR CAVITY MATERIAL* - SEALANT - BOTH SURFACES OF THE WALL, SPECIFIED TECHNOLOGIES INC - SPECSEAL SERIESS SSS SEALANT OR SPECSEAL LCI SEALANT *BEARING THE UL CLASSIFICATION MARK DUCT ACCESS DOORS AND PANELS DOOR SIZE NO. HINGES NO, LOCKS METAL GAGE FRAME DOOR BACK 2" W.G. STATIC AND 12" X 12" 2 1-S 24 26 26 16" X 20" 2 2-S, 22 24 26 LESS 24" X 24 'm 3 2-S 22 22 26 3 " W.G. STATIC 12" X 12'" 2 1-S 22 22 26 16" X20" 2 I -S, 1 -T, I -B 20 20 26 24" X 24 " 3 2-S, 1 -T, 1 -B 20 20 24 12" X 12" 2 2 - S, 1 -T, I _ B 20 20 26 4" W.G. TO 10 " W.G, 16" X20" 3 I -S, 1 -T, I -B 20 IE 24 24 "X24" 3 2- S,2 -T,2 -B 1E 18 24 S = SIDE OPPOSITE HINGES, T= TOP, B = BOTTOM CONSTRUCTION AND AIRTIGHTNESS MUST BE SUITABLE FOR THE DUCT PRESSURE CLASS USED. THESE ILLUSTRATIONS DO NOT PRECLUDE THE USE OF OTHER METHODS AND HARDWARE. EXTERIOR BLANKET INSULATION ALL AROUND FIRE RATED WALL DUCT PENETRATION THROUGH FIRE PARTITION N.T.S. FIRE: DAMPER EXCEPTION PER FBC 607.5.3 WALL MOUNTED INDOOR AC UNIT; INSTALL ON FACTORY FURNISHED MOUNTING PLATE AS HIGH AS POSSIBLE BELOW CEILING, 1 MOUNTING PLATE 2 MOUNTING SCREW 3 ANCHOR S/A PROJ. N�'240CW4 • V • l 4 V V V ••• • V 6 � U V V r" ' W LOUIS J. ANNE & ASSOCIAT" S LA. COha 4A TIhG' FNOIINEENS-*�u 9150 SOUTH"QKDELA,,�D BLD' �1J!TE 9' 0 MIAMI, FLORIDA 33156 TELEPHONE: (305) 670 -0141 FAX: y�G5) 00000 44 •.••• `...• www.ljaap ,'com' 3 1 -1/2" X 1 -1/2" X 16 GAUGE x 10 SHEET METAL STEEL RETAINING SCREWS. (TYPICAL) ANGLES ALL SIDES ROCK (MINERAL) 3 12" LONG X 16 GAUGE WOOL BATTING ALL (MIN, STEEL SLEEVE CENTERE IN SIDES DUCT OPENING tv . 12" MIN. ourrw�xr 26 GAUGE MIN STEEL DUCT EXTERIOR BLANKET INSULATION ALL AROUND FIRE RATED WALL DUCT PENETRATION THROUGH FIRE PARTITION N.T.S. FIRE: DAMPER EXCEPTION PER FBC 607.5.3 WALL MOUNTED INDOOR AC UNIT; INSTALL ON FACTORY FURNISHED MOUNTING PLATE AS HIGH AS POSSIBLE BELOW CEILING, 1 MOUNTING PLATE 2 MOUNTING SCREW 3 ANCHOR S/A PROJ. N�'240CW4 • V • l 4 V V V ••• • V 6 � U V V r" ' W LOUIS J. ANNE & ASSOCIAT" S LA. COha 4A TIhG' FNOIINEENS-*�u 9150 SOUTH"QKDELA,,�D BLD' �1J!TE 9' 0 MIAMI, FLORIDA 33156 TELEPHONE: (305) 670 -0141 FAX: y�G5) 00000 44 •.••• `...• www.ljaap ,'com' 3 i `'` WALL O / 3 tv . ourrw�xr REFRIGERANT PIPING AND CONTROL WIRING TO CONDENSING UNIT; REFER lW Guy TO FLOOR PLANS. CONCEAL PIPING R AND WIRING AS MUCH AS POSSIBLE. 0 CONDENSATE DRAINAGE; REFER TO PLUMBING DRAWINGS, S/A NOTES: 1. THIS DETAIL IS GENERIC, REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2, AC UNIT SHALL BE PROVIDED WITH PROVISIONS FOR FINISHED FLOOR AUXILIARY DRAIN CONNECTION (AT POINT IN THE UNIT LINE HIGHER THAN PRIMARY CONDENSATE DRAIN CONNECTION). A FLOAT SWITCH THAT DE- ENERGIZES THE UNIT UPON ACTIVATION SHALL BE PROVIDED AND PIPED TO THIS AUXILIARY CONNECTION AT UNIT. WALL MOUNTED AC UNIT INSTALLATION DETAIL N.T.S. HINGE FLIP TOP ESCUTCHEONS CALK ALL AROUND (TYP ) WEATHER CAP 22 GA, GALV, SHEET METAL LIQUID SUCTION LINES -- II I DRAIN 76 OVERHANG I II DOWNTURN I CURB SECURE CURB TO ROOF USING FASTENERS AT 8" O,C, BEFORE 10" NOMINAL APPLYING ROOFING AND INSULATION (IF REQUIRED) I I FLASHING HEIGHT ROOFING I II ROOF STRUCTURE SEE ARCH /STRUCT, DRAWINGS. INSULATE VOID TO PREVENT CONDENSATION. TYPICAL REFRIGERANT PIPING PENETRATION THRU ROOF N.T.S. �l i..., I Illlill111 I, � i FAMM r,ARwrE ARTS ■IID.MM! I FI �i Revisions: a a a a a rn Q w 0P ONM N W w O� It h O� v Ct Pm O © x Q4-1 � a U It > Viol J 16" O ,V)..t V LLj x rm1 CONSTRUCTION DOCUMENTS DRAWN: JB CHECKED. ES DATE: 03 -12 -14 SCALE: AS SHOWN SEA two '•jMEQ4A l a" �Ef�111ST9 SA T NA, E. �. x .60788 Sheet No. M7,01 Joa ,r 201335 s I ourrw�xr lW Guy ARTS ■IID.MM! I FI �i Revisions: a a a a a rn Q w 0P ONM N W w O� It h O� v Ct Pm O © x Q4-1 � a U It > Viol J 16" O ,V)..t V LLj x rm1 CONSTRUCTION DOCUMENTS DRAWN: JB CHECKED. ES DATE: 03 -12 -14 SCALE: AS SHOWN SEA two '•jMEQ4A l a" �Ef�111ST9 SA T NA, E. �. x .60788 Sheet No. M7,01 Joa ,r 201335 s