Loading...
14-375-019ATE: THE DETAILS ON THIS SHEET AfRE GONSIDEFED T''FIC,AL AND AIRS NOT NECESS,AFIL`l C,ALLEI) OUT ON FLANS rsr• ••• r • •rr•e BOG' NOTE: ALL RATED PENETRATION DETAILS ON THIS SHT. ARE TO COMPLY WITH UNITED STATES GYPSUM COMPANY DETAILS FOR HOSPITAL ANILULIN5Th-UTIO,IAL CONS?Rl(CTIOk HANDBOOK DATED FEBRUARY ISSI, REVISED AUC%UST ISSI. EQUIVALENT DETAIL NUMBERS ARE SHOWN WHERE APPLICABLE ••au �wv�r u rd V +tice u 1 OR 2 HOUR FIRE OR SMOKE WALL .�w. +r vu �I CLIP 2' -0' (PER UL) ACOUSTICAL SEALANT - SGREW so + +�� + • BACK AND SIDES OF ro BOX AS NECESSARY © LABELED ACCESS PANEL ° • • • METAL STUD FOR SOUND RATING • 4' O.C. Y _ ONE OR TWO LAYERS OF DRYWALL - - 5 /b' TYPE 'X' - AS REQUIREp FOR WALL CONST. 1- 1/2, CRC „ � �, u • � u • + c � o r r • � u FIRE RETARDANT ACOUSTICAL SEALANT TAPE AND FINISH BEHIND CABINET FIRE RATED CEILING{ W •� v TREATED WOOD AROUND BOX PENETRATION MAXIMUM 16 50. IN. STUDS SIZED A5 REQUIRED FOR PIPIN • • • • • u c a u • • w c u v STU 5 16' O.G. 1 MAXIMUM I 00 s� TELEPHONE OR ELECTRICAL BOXES SECTION AT CEILING LAMINATE BACK PIECE TO WALLBOARD LINER PANEL :I I E -STUD � I 5HA OW FIVE 51 OX DETAIL L — — — -- =—LJ J- RUNNER SAFING REQUIRED WHERE BOX EXCEEDS 16 5Q. INCHES — — FASTEN TO E -STUpS OR AGGREGATE OF BOXES EXCEEDS 100 SO. INJ STUDS 24' D.C. CHANNEL 100 SF OF WALL AREA. VARIES © LABELED ACCESS PANEL IMPALING CLIPS - ELECTRICAL JUNCTION BOXES J- RUNNER PLAN VIEW (2) PER STUD + FASTEN TO E -STUDS SPACE WHEN A METALLIC JUNCTION BOX FOR ELECTRICAL RECEPTACLES OR SWITCHES 15 CONTAINED WITHIN ELECT. PANEL, P.H.C. OR OTHER A RATED WALL OF GYPSUM DRYWALL CONSTRUCTION AND AN OPENING IS PROVIDED FOR THE BOX IN E THE SURFACE OF THAT WALL, THE AREA OF THE OPENING MAY NOT EXCEED I6 SQUARE INCHES, UNLESS WALL MOUNTED CABINET THE JUNCTION BOX 15 ENCLOSED BY A '5 -SIDED BOX' (SEE APPROVED DETAILS). SCREWS i + + CLIP AT EACH THE AGGREGATE AREA OF ALL SUCH JUNCTION 13OXE5 IN A RATED WALL NOT ENCLOSED BY FUR WALL ABOVE AND BELOW NOTES: STUD 15 -SIC)ED BOXES' DE5CRIBEQ ABOVE SHALL NOT EXCEED 100 SQUARE INCHES IN 100 SQUARE FEET I. GYPSUM BOARD APPLIED VERTICALLY. 5 /8' TYPE 'X' OF WALL AREA AS MEASURED FROM FLOOR TO STRUCTURAL DECK OR RATED MEMBRANE. 2. JOINTS TO RECEIVE 5HEETROCK TAPE AND JOINT COMPOUND, JUNCTION BOXES WITH OPENINGS ON OPPOSITE FACES OF RATED WALLS SHALL HAVE A HORIZONTAL SEPARATION OF 24 INCHES AS A MINIMUM, REGARDLESS OF BOX SIZE, UNLESS ENCLOSED BY '5 -51DED BOXES.' LOCATIONS OF STUDS DO NOT HAVE ANY BEARING ON THE ABOVE REQUIREMENTS, NOR DOES THE USE PLAN DETAIL AT SHAFT WALL SECTION RATED PARTITION PENETRATIOS OF I -HR RATED CEILN16 A55EMBLY OF MINERAL WOOL FIRE 5AFING ALTER THESE REQUIREMENTS. REF: UL SYSTEM No. 409 EQUIV: TO SKETCH " 206, U56, HANDBOOK EQUIV: TO SKETCH 101, USG, HANDBOOK j TYPIGAL JOINT REQUIREMENTS FOR 1 HOUR WALL N.T.5. (2) RATED PARTITION PENETRATION DETAIL N.T.S. TYPICAL FIVE SIDE BOX DETAIL 4 RECESSED WALL CABINET DETAIL �j- ACCESS PANEL INSTALLATION DETAIL N.T.S. ON RATED PARTITION SECURE ANGLE FIRE RESISTIVE MATERIAL -" GREATER THAN 2' LESS THAN (o' 5RACE 1" MIN, OVERLAP METAL STUDS FIRE DAMPER ...� FLOOR OR ROOF SLAB A55EMBLY SLEEVE BREAKAWAY CONNECTION li I OPTIONAL CUT GYPSUM PANELS TO 5 /5' TYPE 'X' GYP. Bp, OPENING TO BE S MATERIAL OF RATING FIT PECK GONFIG. LINED WITH FIRE WOOD STUD EQUAL TO THAT ON ONE OR TWO LAYER GF DRYWALL NOM, GAP FILL R WITH E615TIVE THE WALL (REQUIRED BY AHCA) ALTERNATE I: BLOW -OUT ONE WITH ACOUST. SEALANT STRAPS WRAPPED AROUND SIDE OF WALL TAPE t JOINT RUNNERS - ATTACH WITH METAL STUDS MAY BE COMP. DRYWALL OR SEALANT ANCHORS 2' -0' O.G. USED ON SOME UL. FIRE RATED ACOUSTIC APPROVED FIRE DAMPER CEILING METAL RUNNERS CEILING= A55EM5LY ASSEMBLIE6 IN PLACE OF ALTERNATE 2: FIRE PAMPER ANGLE IRON FRAMES. - CHANGE OF CEILING H I HT AT T CEILING SLEEVE I FACE TO BE SEALED WITH CONTINUOUS STEEL STUDS ]'MIN, OVERLAP DRYWALL, SEALANT, OR TAPE (16" / 24' D.G.) FT 7 BREAKAWAY Y; AND JOINT COMPOUND CONNECTION NOTE: OPTIONAL LINING OF S OPENING: LOCAL OVER 1" GAP REQUIRES A SECURE WITH FIRE RESISTIVE METAL STUD AUTHORITIES MAY REQUIRE BLOW -OUT PATCH CEILING MATERIAL OF RATING OPENING TO BE LINED ACOUSTICAL SEALANT BRACE EQUAL TO THAT ON THE RUNNERS - ATTACH WITH WALL FOR SOME FIRE PACK WITH THERMAFIVER ANCHORS 2' -0' O.G. METAL STUDS DAMPER INSTALLATION. DENSITY AT MANUFACTURED WITH NO VOIDS FIN. FLOOR DAMPER REQUIRED (NOT REQ'D. BY AHCA) - I' MIN. OVERLAP OR GAPS (FIRE ONLY) FIRE DAMPER SLEEVE DUCT BREAKAWAY ---- -� �� AT��N OR 2M MAY BE USED ON EITHER SIDE OF WALL_ 5 /b' THPE "X' GYP. Bp, CONNECTION ONE HOUR WALL ONE 51DE OF PENETRATION MAY REMAIN OPEN. w. CON C RETE OR. MA50N Y ' IRE RATED SECTION CEILING ASSEMBLY NOTE: ASSEMBLY TRANSITIO SPECIFIC FRAMING REQUIREMENTS OF OPENINGS NOTES: N.T.S. NON RATED I CEILING A55EMBLY SHOULD BE PROVIDED IN THE ARCHITECTURAL . JOINTS MAY BE OPPOSITE IF SAFEING IS USED IN CAVITY. ,SST f2-0 AND STRUCTURAL DRAWINGS THAT ARE SUBMITTED REF: CEG 6-11 -53 CEG 5 -9 -54 t- 3362-T-3362-061.1 NOTE: 2 LAYERS 5 /6' TYPE 'X' DRYWALL FOR BUILDING PERMITS. 2. JOINTS IN FINISH LAYER TO RECEIVE TAPE AND JOINT COMPOUND GA-WP-1200 GA- ulr' AT 2 HOUR RATED CEILING ASSEMBLY REF: UL SYSTEM No. WL 1065 -12o0 BULKHEAD AT ONE -HOUR HORIZONTAL JOINT REQUIREMENTS I SMOKE 4 ONE -HOUR PARTITION DETAIL N.T.S. (o N.T.S. DAMPER SLEEVE INSTALLATION DETAIL N_T.5_ S MULTIPLE PIPE PENETRATION DETAIL N.T.S. 9 N.T,s. (KNIENDICULARTOpFCK) RATED CEILING ASSEMBLY ABOV SUSPEND D CEILINGS TRACK OR BLOCKING BAR JOISTS FLOOR OR ROOF SLAB ASSEMBLY STRUCTURE ABOVE _ I HR RATED r_. - MAX. 2' ^ DECK MEMBRANE NEW 5/6' TYPE "X" FILL VOIDS. SEE DETAIL "6 I f IPING AND /OR CONDUIT NEW STUD EXTEN51ON U REMOVE EXIST. Y OVER 6' UNDER V SCHEDULE DRYWALL PIPING TIGHTLY FILL VOIDS AT METAL CEILING- I u SEALANT DECK WITH SAFINGs MATERIAL - 3_5/,a' TYPE 'X" GYPSUM �' E - 4 * /CF DEN WALLBOARD AT RATED RATED CEILING A/C DUCT 2 I/2' C ON 5/S' GYPSUM BOARD RUNNERS - ATTACH WITH PARTITIONS n NOTE: ALL DRYWALL ANCHORS 2' 0' O.G. OVER 3 5/8' METAL STUDS DRYWALL JOINTS ELECTRICA S FRTW BLOCK (2x4) CEILING STAGGERED AT 5 /b' TYPE 'X' CL PARALLEL TO STRUCTURE RATED PARTITION SIDES S67 M N. 12' CONTINUOUS STEEL STUDS F.EJF. HOSE EXISTING WALL REMOVE EXIST. (16' / 24' O.G.) CABINET/ HEAD TRACK CLEA CLEA CLEA ELECTRICAL/ 5AFING AS REQUIRED TELEPHONE PANELS EXTEND EXISTING WAL)_ 2 H WA TH I H G G. A55' A/C DUCT - -- TO DECK FOR I HR WALL (SHAFT WALL SIMILER) ACOUSTICAL SEALANT PECK —RECESSED L1Cxl f FI TURE IA — RUNNERS - ATTACH WITH ��� TRACK OR BLOCKING ANCHORS 2' -0' O.G. I CLIP FIN. FLOOR EXTRA WIDE D LL 2 PER STUD BAR JOISTS r SPACE ROOM CORRIDOR ROOM - - - �— I I HR RATED Y MEMBRANE T • ---ALL DRY WALL . OVER 6' UNDER V ' 11' 5 /b' TYPE 'X' SECTION RATED WALL SEALANT N.T_S, NOTE: FURRING 2 1/2' C ON TEST REF: REFER TO VV FLOOR PLAN FOR EXACT LOCATIONS RATED CHASE WALL THRU 1 HR CFCs ASS-Y. FURRED IUALL_ FRTW BLOCK (2x4) T- 3362 -05U F_ E. CABINET T- 114 -05U BLOCKING IN WALL IS RE RATED PARTITION NOtEREQUIRED GA -WP -1200 SMOKE t ONE -HOUR PARTITION DETAIL FIRE EXTINGUISHER CABINET /ELECTRICAL/ PARTITION PENETRATION DETAIL OF N.T�_ EQUIPMENT CLEARANCE DETAIL N.T.5. �� MEMBRANE EDGE SUPPORT DETAIL N,T.5. I j N.T.S. I2 N.T.S. I3 ONE HOUR RATED MEMBRANE (rERPENDIGUL.ARTOpECIG TELEPHONE /PANELS SECTION PERPENDICULAR TO STRUCTURE c .yip a r 1(o N.TS. 1 N.T.S. 18 N.T.S. I J N.7.5. 2 N.T.5. • u u • 6 u Y uv u .u+ u Revisions: d A 0 �a i O O 0 y p� to o rl' M V CLn so O rV F. w r O r w �M M nLn O Ln t7f � M o i V F-� r� . m M � � x � Q z O �V wl 3 A Q 161 O LIJ 1 i i 0­+ LL-0 V) A uj z O r, Q W 04 z LAj CONSTRUCTION DOCUMENTS DRAWN: GAC CHECKED: LEN DATE: 03 -12 -14 SCALE: AS SHOWN i e SEA�Ir j 0;7 . 1ia ` , t'Fp..F,R I Sheet No. A -17 OF 17 ]Qa # 201335 I i I 1 i i SEA�Ir j 0;7 . 1ia ` , t'Fp..F,R I Sheet No. A -17 OF 17 ]Qa # 201335 I i I