14-375-015Yrti• ••r �• o� •
.,or•Y
V c • ° r � V
• Y V Y Y •
••rY •r• • r r •r•• C
V • r • • M
0 get,
V • E+ • V Y V V r V
s UNDERSIDE OF Y Y r a• Y Y
EQ. r Y Y YYr YuU
EXI5TIW3 STR LICTURE
METAL STUDS.
rr•• Yr YYYr
• Y 41 0
MTL. STUDS • • r Y Y r
UNDERSIDE OF FACE OF FI 15HED WALL
W
• 1 b' O.G. Y r • *Vow r
E W r
XISTING STRUCTURE a Y r r•
(j c ACOUSTICAL •
ul
CEILING
CORNER BEAD
ACROSS SO
CEILING SUSPENSION O i FFIt.
SYSTEM TO UNDERSIDE _ ... ..... C3 -j PAINTED p
OF STRUCT. yi W b . — — 5/5' GW.B
ACOUSTICAL u
CEILING TILE r` Q
ACOUSTICAL 5 /6' G.WB.
1- QQ
J
CEILING PANEL (SEE cry iv
SPECS FOR tYPE) T
2'x2'
METAL ANGLE STRIP CEILING { 0
FIN15H TO MATCH GRID F
'1' SYSTEM
'7' RUNNER SUSPENDED ACOUSTICAL DOOR FRAME
CEILING TILE: SEE SMOKE DETECTOR OR ACOUSTICAL r Z
CEILING PLAN AND SPECS SPRINKLER HEAD
FOR TYPE O
NOTE: DO NOT SUPPORT SOFFIT
FROM FIRE RATED PARTITIONS.
AT FIRE PARTITIONS ANCHOR TO
STRUCTURE ABOVE.
1 CEILING DETAIL N.T.S. 2 CEILING DETAIL N.T.5- 3 CEILING DETAIL N -T.S- 4 CEILING DETAIL N.T.S. rj CEILING DETAIL KT -S.
I
UNDERSIDE OF
EXISTING STRUCTURE
UNDERSIDE OF FADE OF 45' MAX.
\ \ 1 EXISTING STRUCTURE STUD OR
1 FURRING
45' A 12 GA HANGER WIRE Q 48" O.G. UNISTRUT
UNDERSIDE OF 3_5/5" MTL. STUDS EA WAY TO BE ATTACHED 6 CONNECTIONS
EXISTING STRUCTURE BRACKETS • Li J
5 /5' GOB. 3-5/5' \ \ 4' -0' O.C. I. m
MAX OF 45 DEGREES, MIN OF 4 Y
MTL. STUD 5RACIW • SIDES OFF TURNS LL BRACING WIRE TYP
BRACING • \ I \ ACOUSTICAL 4' -0' Or-,
4 + -0' O.G. I s CEILING TILE
\ OR G W B. SEE 5 /8' GOB.
REF. CLG. PLAN MAX.
.
45' MAX. MAIN RUNNER 4' -O" O.C.
\ ACOUSTICAL s 45
SEE INTERIOR CEILING TILE
OO. SE
SEE INTERIOR \ \ ELEVATION OR REFLECTED E SHIM AS NEEDED
ELEVATION OR REF. CLG. PLAN CLG. PLAN ACOUSTICAL
REF. CLG. PLAN
At FIRE RATED a 9 UNIStRUT NUTS
PARTITION 15 /a' CEILING PANEL
ANCHOR MTL, 3 -5 /a' OR 15m'�O.C. AS SHOWN GE104 GRID
STUDS TO SLAB MtL. STUDS 5/5" GW.B. ---• °- PRE - FO�IED
ABOVE. SEE CABINET 114' OC.
DETAILS a `n U NOTES:
w tu I. ALL 24'X48" CEILING LIGHT FIXTURES t 24 "X24' HVAC AIR REGISTERS SHALL
COIa7ER 6EAD � BE SUPPORTED BY A MINIMUM OF (2) HANGERS + OPP051TE CORNERS. CEILING
MTL. STUDS ACROSS SOFFIT. ACOUSTICAL ( .
CABINET WORK (WHERE • Ib' bC. CEILING TILE > -s /a• METAL SYSTEM SHALL NOT SUPPORT OTHER ITEMS. NOTE.
APPLIES) SEE INT. SEE REF. CLG, PLAN a OR GWB. SEE STUD FRAMING
ELEVATIONS AND REF. z REF. CLG. PLAN VARIES /RIC " O.G.
CLG. PLAN. N (•SEE REFLECTED CLG PLAN) FLAME ALL INTERIOR WALL 4 CEILING FINISHES SHALL BE INSTALLED TO CLASS III CONTRACTOR TO PROVIDE SIGNED < SEALED
FLAME SPREAD. SHOP DRAWINGS WITH FRAMING PLAN, SECTIONS t
r
DETAILS
3. 45 DEGREE BRACE WIRES ARE TO BE PROVIDED ONLY LS FOR APPROVAL
IF REQUIRED BY LOCAL BUILDING DEPARTMENT.
SOFFIT DETAIL N.T.S. SOFFIT DETAIL N.T.5. S SOFFfT pETAIL N.T.S. 9 N.T.S. 1� TYPICAL UNISTRUT DETAIL N.T.S.
UNISTRUT TO PROVIDE SHOP DRAWINGS FOR THE TELESPAR ANCHORING
SYSTEM FOR STRUCTURAL ENGINEERS REVIEW
INTERIOR PARTITION
3 -5 /s' x 20 ga METAL STUDS
TELESPAR TUBE AT 16' O.G. SECURED TOP S' CM -U. WALL 2 x 4 WOOD BACKING=
O Q 5PRINKLER - = AND BOTTOM TYP.
_ AT TOP OF WALL CABINET
HEADS TO 0 5/8' DUROC
BE POP- CROSS BRACING O 5/$' DUROCK WALL CABINET
DOWN TYPE. AS REQUIRED, O
1 x 4 WD. BACKING I x 4 WD. P.T. BACKIN I INTERIOR PARTITION
10 0 AT 331/2' ABOVE AT 331/2' ABOVE - 3 -5 /s" x 20 ea METAL STUDS
111001 UNISTRUT CHANNELS 0- FINISH FLOOR FINISH FLOOR I AT 16" O.G.
(TO BE VERIFIED BY A
STRUCTURAL ENGINEER) FINISHED P1000 HORIZONTAL UNISTRUT 2 x 4 WOOD BACKING AT
I
WITH PRE - INSTALLED CLEAR AREA CE LING CP055 BRACE BOTTOM OF WALL CABINET
CEILING ANGLES. FOR LIGHTING
1/2" GYPSUM
WALLBOARD
111001 UNISTRUT CHANNEL --
SEE PLAN ,..-____- ._�_____= ='� - -�
331/2' ABOVE 331/2' ABOVE
NOTE: UNISTRUT CHANNEL COVERS MUST BE SUPPLIED AND INSTALLED FIN15H FLOOR FINISH FLOOR NOTE. NOTE: A MINIMUM 2 x 4 HORIZONTAL WOOD MEMBER
UNISTAUT CHANNEL COVERS TO BE SUPPLIED AND INSTALLED BY CONTRACTOR AFTER EQUIPMENT HAS BEEN MOUNTED TO THE CEILING. (FIELD ADJUST) SECURELY FASTENED TO NOT LESS THAN 2
STUDS, SHALL BE INSTALLED FOR THE ATTACHMENT
CONTRACTOR AFTER EQUIPMENT HAS BEEN MOUNTED TO CEILING,
OF EACH WALL CABINET.
THIS DETAIL SHOWS A UNIVERSAL TELESPAR DROP THAT 15 TYPICAL
�c SEE STRUCTURAL DRAWINGS FOR OF THE STRUCTURAL SUPPORT SYSTEM USED FOR CEILING MOUNTED NOTE: PROVIDE I x 4 WD. P.T. BACKING AT 331/2" ABOVE FINISHED
FRAMING, SECTIONS t DETAILS IMAGING EQUIPMENT. UNLESS OTHERWISE SPECIFIED, THE CUSTOMER/ FLOOR SHALL BE INSTALLED FOR THE ATTACHMENT OF
CONTRACTOR SHALL SUPPLY AND INSTALL ALL SUPPORT MEMBERS AND EACH WALL HUNG PLUMBING FIXTURE
THE CONTRACTOR MUST PROVIDE SHOP DRAWINGS NEEDED HARDWARE. IN THE EVENT AN EXISTING SUPPORT SYSTEM 15
* TO BE USED, IT WILL BE THE UNI5TRUT'8 RESPONSIBILITY TO VERIFY
SIGNED AND SEALED BY A STRUCTURAL ENGINEER ON THE INTEGRITY OF THAT SYSTEM. SEE THE 114' SCALE PLAN FOR
THE PROPOSED DESIGN FOR THE UNISTRUT SYSTEM. LOCATIONS AND SPACING OF P1001 UNISTRUT CHANNELS.
TYPICAL UNISTRUT DETAIL N -TS (12) TYPICAL UNISTRUT DETAIL 13 PLUM31NG FIXTURE BACKING DETAIL N "T.S. WALL CABINET 5ACKING DETAIL N.T.S. N.T.5-
11 P
Revisions:
Z
0
L
A
A
N ^s
�O
My
OV
M
F L
qty
W � H
V
E ., O
o
O�
oil
W
N M
7 C V
rn
M
vi n
O y:.i1
LIZ
V h
C
P-4 i
i
i
I A
I .
I ^
i .
o ^_
V is
4.0 9
O
w
W
W V
Az
V O
zz �
W
U
I�
U V)
U.
I
z
1 ^
a
w
CONSTRUCTION
DOCUMENTS I .
DRAWN. GAG
CHECKED: LEN
DATE: 03-12-14
SCALE: AS SHOWN
SEA1.. Pr" ',.
O... cps
10 -, J '(L
v` r F-D
Sheet No.
A -13
OF
17
JQIS # 201335