14-375-005-- TYPICAL
Q
d
�o
Y
CEILING
SINGLE
ELECTRICAL
OUTLET
J -BOX FOR DATA
OUTLET DOES N01
NEED COVER
PLATE. THE
CABLE GOES
THROUGH THE
ACCESS HOLE.
F.FLOOR
(D—D'E ME CLOCK CKRONUS)
TAI L N.T.S.
11)41_L-MOUNTED
TELEPHONE DETAIL
N.T.S.
2
)OOR FRAME
IGHT SWITCH
'ELEPHONE
UNCTION BOX
�)z" x 101' PHONE
)UTL INE
/OLUME
:ONTROL
I I r /— CEILING
Y
4x4 TV
JUNCTION BOX
w
� ro'
rt
kk4x4 JUNCTION
BOX.
� �F.FLOOR
NOTE: TV OUTLET AND J -BOX 84" A.F.F.
W/. 2 -3/4" CONDUIT STUBBED UP (o'
ABOVE CEILING.
PROVIDE A 4 "x4' J -BOX 18' A.F.F. AT
WAITING AREAS
TV OUTLET DETAIL AT WAITING AREA
N.T.S.
PAi�TIAL SIXTH FLOOfR
EOJIFMENT PLAN
SCALE: 1/411 = V-0"
* FOR STAFF TOILET INTERIOR ELEVATIONS 4 DETAILS SEE SHEET A -9.
NOTES:
IN ADDITION TO THE OUTLETS SHOWN
ON THE PLANS. GENERAL CONTRACTOR
SHALL PROVIDE THE FOLLOWING
OUTLETS IN THE DESIGNATED ROOMS
AT NO ADDITIONAL COST TO THE
OWNER. FINAL LOCATION TO BE
INDICATED DURING CONSTRUCTION
- 10 ELECTRICAL OUTLETS.
- 6 STR05E6.
- 4 SPRINKLER HEADS.
- 4 EXIT SIGNS.
- 5 SMOKE DETECTORS.
- 5 FIRE ALARM SPEAKERS.
- 4 FIRE ALARM PULL STATIONS.
- 4 STROBES /BELLS.
- 2 STROBES/BELLS /PULL STATIONS.
- 3 FIRE EXTINGUISHERS.
- 20 JBOXES W/. 3/4" CONDUIT TO
CEILING. 10 FOR WIRELESS ACCESS
POINT SYSTEM (JOE HAYDEN WILL
PROVIDE LOCATION DURING
CONSTRUCTION).
NOTE:
ALL JUNCTION BOXES,
DISCONNECTS, AND ELECTRICAL
PANELS (EXCEPT AT ELECTRICAL
ROOMS) ARE TO BE RECESSED.
CONTRACTOR IS RESPONSIBLE TO
RECESS ALL BOXES. IF A BOX
DOES NOT APPEAR RECESSED IN
THE DRAWINGS, THE CONTRACTOR IS
RESPONSIBLE FOR ASKING THE
ARCHITECT IF IT SHOULD BE
RECESSED. ANY BOXES THAT ARE
INSTALLED SURFACE MOUNTED AND
THE OWNER REQUESTS IT BE
RECESSED, SHALL BE RECESSED
AT NO ADDITIONAL COST TO THE
OWNER. IF PARTITION DOES NOT
ALLOW FOR THE RECESSED
INSTALLATION, CONTRACTOR IS
RESPONSIBLE TO BRING THIS UP
BEFORE INSTALLING THE STUDS.
NORTH
y
1
OFFlCE BUILDING
J
B
O r1
N
r1 O
NJ
t8
ourPATIENT ,.
III1111111 y � SURGERY
1 PARKING
GARAGE I» fil
� ly fil
ly rl '
F-
11
p u (CAL ARTS
FIROJECT AREA
• SIXTH FLOOR &W. 62ND AVENUE
KEY PLAN
N.TS.
NOTES: W • %%
OWALL MOUNTED DIAGNOSTIC SET 5' -0" TO
CENTER LINE OF UNIT. .•. •". .W W
u • c W • o • . r u
V 4' W W r \. V V V Y•
DIGITAL WEIGHT
G� COMPUTER (DESK M011NTED),.... W.• W..•
• W W W
TELEPHONE WALL MOUN.TEP. C,t. ; ET
TYPICAL UNLESS NOTED.
OPATIENT EXAM TABLE. REQUIRES POWER -
PLUGGED TO WALL OUTLET.
OGOOSENECK LAMP. PORTABLE W/. WHEELS_
WILL BE PLUGGED TO TABLE.
NOT USED
OEKG MACHINE.
OPROVIDE LOCKS FOR ALL DOORS 4 DRAWERS
IN THE CABINETS AT EXAM 4 TREATMENT
ROOMS.
ONOT USED
ONOT USED
DESK - TOP PRINTER.
ONOT USED
ONOT USED
(O NOT USED
OP UNDER COUNTER REFRIGERATOR W/, FREEZER.
�Q NOT USED
NOT USED
ODESK -TOP SCANNER.
TO TELEPHONE DESK MOUNTED.
OCREDIT CARD MACHINE.
ODRAWERS TO LOCK.
0 SCANNER FOR ID.
(X J OUTLET FOR X -RAY VIELUER AT 4' -0' AFF.
O SAFE.
OCAMERAS/ SECURITY/ NO OUTLETS
CP CONTACT POINT.
GR CARD READER.
V SINGLE DATA OUTLET -
V'TELEPHONE WALL OUTLET AT 48' AFF
DOUBLE DATA OUTLET.
0 QUAD DATA OUTLET.
SINGLE RECEPTACLE - SPECIFIC USE.
DOUBLE RECEPTACLE.
Tv TV ELECTRICAL OUTLET W/. J -BOX FOR
COAXIAL CABLE '1' -0' A_F.F. SEE DETAIL.
JUNCTION BOX / FOR LOW VOLTAGE, UNLESS
OTHERWISE NOTED.
AA WALL SECURED TABLE OP /CI PROVIDE
BACKING.
EW NOT USED
CC NOT USED
BB KRONUS - SEE DETAIL 'I" ON THIS SHEET.
DD PROVIDE 2 - 30 AMP_ CIRCUITS ABOVE RACK
MOUNTED 40 AF_F. SEE ELECTRICAL FOR
PLUG* TYPE. SEE ELECTRICAL PLAN.
EE PROVIDE SLEEVES 2 -4' CONDUITS EXTENDING
6" TO EACH SIDE - SEAL EDGE OF CONDUIT.
COORDINATE W/. IT HOW MANY/ WHERE / SIZE.
FF OWNER PROVIDED / OWNER INSTALLED RACK
al IT ROOM.
CsG PROVIDE 2 - (8' x 4' x 4 ") PLYWOOD FOR WALL
MOUNTED SYSTEMS IN IT ROOM PAINT - FIRE
TREATED GRAY.
GNOT USED.
II AT LOUNGE 4 OTHER REFRIG, W/. ICE MAKERS,
PROVIDE A RECESSED BOX TO HOUSE THE
WATER LINE 4 BACK FLOW PREVENTER.
JJ NOT USED.
aSEMI - RECESSED DEFRIBULATOR
BOX. 48" A.F,F. TO (t OF BOX.
GWALL MOUNTED/MINITOR / COMPUTER BRACKET.
O0l.FIICArnONS ONLY
INTERIOR M vIRE
(ANY E)a A 00ARD �AYP`A OC 1Y R1�Q
0
0
0
0
io
cV ^ o
M
Ln
V oLn
O~
V _
E o gn
O
O�
O�
w
W
aidv
h ,n
rn M
VM
G
1440,
4
3y
"Pow I"'" j
c
i••)�"'
O
Y
1
E
r
0 u) I
�V
r
ii
O
a
OZ
O<
L
�z
W
V` • E
1�
rV
W
a
CONSTRUCTION
DOCUMENTS
DRAWN: GAG
CHECKED: LEN
DATE: 03-12-14
SCALE: AS SHOWN
sEAL,,=
Willi a
Sheet No.
A -3
OF
]7
JOB 9 201335 I