14-375-003i -- THIS DRAWING IS ONL ,r TO 46515T IN SHOWING THE
SCOPE OF DEMOLITION WORK AND IS NOT
INTENDED TO INDICATE ALL DEMOLITION.
CONTRACTOR SHALL REMOVE ALL EXISTING
ITEMS AS REQUIRED TO COMPLETE THE JOB.
2.- NOT ALL ITEMS TO BE DEMOLISHED ARE
SHOWN ON THE PLAN. CONTRACTOR SHALL BE
RESPONSIBLE FOR PERFORMING A WALK -THRU
OF THE PROJECT PRIOR TO SUBMITTING A BID
TO THE OWNER FOR IDENTIFYING POSSIBLE
CRITICAL ITEMS, NOT OR INCORRECTLY
ADDRESSED, WHICH REQUIRE REMOVAL/
RELOCATION,
3.- PROVIDE SAFETY FEATURES DURING WORK AS
CALLED FOR IN SPECS, APPLICABLE CODES,
RULES AND REGULATIONS HAVING JURISDICTION
OF THE PROJECT.
4.- CUT, REMOVE, PATCH, ALTER AND REFINISH
EXISTING CONSTRUCTION AS REQUIRED TO
LEAVE WORK COMPLETE AND IN SATISFACTORY
MANNER
5.- CONTRACTOR IS TO PROTECT ALL UNDER -
GROUND OR OTHER CONCEALED UTILITIES. HE
IS TO INSPECT CEILING AND CHASES TO
ASSURE PROPER IDENTIFICATION OF UTILITIES.
MECHANICAL AND /OR ELECTRICAL
CONTRACTOR ARE TO CAP THEM AS
REQUIRED.
G.- OPENINGS LEFT THROUGH RATED AND SMOKE
PARTITIONS DUE TO REMOVAL OF DUCTWORK
CONDUIT SHALL BE CLOSED (BOTH SIDES)
1- REMOVE ALL EXISTING ACOUSTICAL TILE CLG.
AND SUSPENDED SYSTEMS IN THE RENOVATION
AREA AS REQUIRED FOR INSTALLATION OF WORK
TO BE DONE. COORDINATE REMOVAL WITH
ELECTRICAL CONTRACTOR REGARDING EXISTING
LIGHTING FIXTURES ETC.. REPLACE CEILING
ACCORDINGLY AFTER COMPLETION OF WORK.
GENERAL DEMOLITION NOTES.
S -- CONTRACTOR IS TO SAW -CUT ALL OPENINGS IN 10.- CONTRACTOR IS TO COORDINATI~
CONCRETE BLOCK WALLS IF REQUIRED_ CONTRACTOR DEMOLITION WORK WITH ADMINISTRATION AND
SHALL NOT DEMOLISH OPENINGS WITH SLEDGE IS TO GIVE SUFFICIENT ADVANCE NOTICE OF
HAMMER UNTIL OUTLINES HAVE BEEN CUT. THE BEGINNING OF WORK IN EACH EXISTING
FLOOR TO ADMINISTRATION (12 HOUR
MINIMUM)
9.- RENOVATION WORK MAY ENTAIL INTERVENTIONS IN
AREAS OUTSIDE OF THE IMMEDIATE SCOPE OF WORK,
INCLUDING WORK ABOVE AND /OR BELOW THE FLOOR
LEVEL WITHIN THE SCOPE. IT MAY REQUIRE WORK
INVOLVING REMOTE UTILITY LINES (ELECTRICAL
MECHANICAL, PLUMBING, COMMUNICATIONS). ANY
WORK IN AREAS OUTSIDE OF THE IMMEDIATE SCOPE
OF WORK SHALL BE ALL - INCLUSIVE, PROVIDING ALL
STRUCTURES, UTILITIES, FINISHES AND EQUIP.
REQUIRED TO RESTORE THE AREA TO FULLY
OPERATIONAL CONDITIONS, TO FULLY COMPLYING
RATING INTEGRITY, AND TO MEET OWNER'S
APPROVAL ALL WORK AS DESCRIBED IN THIS NOTE
IS TO BE PART OF THE BASE CONTRACT PRICE, OR
CONTRACT CONTINGENCY ALLOWANCE FOR SUCH
WORK.
iL- CONTRACTOR SHALL VERIFY EXACT LOCATION
OF EXISTING CONCRETE COLUMNS IN AREAS
WHERE WALLS ARE BEING REMOVED AND
INFORM ARCHITECT OF ANY CONFLICTS
BEFORE ANY WALLS ARE REMOVED SO THAT
A/E CAN INSPECT THEM FOR CLARIFICATION
PRIOR TO PROCEEDING WITH WORK.
13.- DEMOLITION IS DENOTED BY BROKEN
LINES.
14.- FOR REMOVAL OF FIXTURES AND EQUIPMENT
SEE ARCHITECTURAL, PLUMBING, MECHANICAL
AND ELECTRICAL DRAWINGS.
PREPARE EXISTING CONCRETE 6L4545 REQ.
BY GRINDING, LEVELING WITH ARDEX LEVELER
AS PER MANUFACTURERS SPECIFICATIONS.
MATCH EXISTING SLAB ELEVATION AS
REQUIRED TO RECEIVE NEW SCHEDULED
FLOORING MATERIAL.
I&.- VERIFY WITH CIVIL, PLUMBING, MECHANICAL AND
ELECTRICAL DRAWINGS, ITEMS TO BE
REMOVED /RELOCATED IN CASE OF CONFLICT.
12.- PATCH AND REPAIR ALL EXISTING SURFACES
DAMAGED BY DEMOLITION AND /OR INSTAL- )I.- DESTINATION OF ALL EXISTING EQUIPMENT,
LATION OF NEW ELECTRICAL CONDUITS, GAS
PIPING, ETC.. AS REQUIRED TO MATCH PLUMBING FIXTURES, DOORS AND FRAMES, ETC.
ADJACENT SURFACES AND /OR AS REQUIRED TO BE REMOVED SHALL BE COORDINATED
FOR NEW SCHEDULED FINISHES, WITH THE OWNER.
18.- CONTRACTOR TO SURVEY PROJECT AREA PRIOR
TO COMMENCEMENT OF WORK. NOTE AND REPAIR
ANY DAMAGE TO AREAS WHERE WORK IS GOING TO
BE PERFORMED. NOTIFY OWNER AND ARCHITECT
WITH A LIST OF WORK PRIOR TO CONTRACT.
19•- THIS SET OF DRAWINGS IS TO BE USED AS A UNIT
CONTRACTOR IS RESPONSIBLE FOR ALL DISCIPLINES
t SHOULD INCLUDE EVERYTHING THAT IS NEEDED FOR
MAKING ALL SYSTEMS WORK. EXAMPLE. IF A SINK IS
SHOWN IN THE ARCHITECTURAL PLANS, IT IS ASSUMED
THAT THE G.C. IS PROVIDING EVERYTHING NEEDED,
A/E WILL PROVIDE THEM WITH THE UNDERSTANDING
THAT THERE WILL BE NO ADDITIONAL COST TO OWNER.
PARTIAL SIXTH FLOOR
DEMOLITION PLAN
SCALE: 1/4" = V -0-
606-
WE
Y V W V V U V
Duo u Y E V
DEMOLITION
13
EX15TING RFINF�-)RCED GONC,. •
COLUMN 0lf, f_-C 1GRiW Tt_ WALY •
`
TO REMAIN •: � �
W U V G Y •
EXISTING WALL OR
PARTITION TO REMAIN
vs•
V:+wv• W v V Y • V
Yu • a
• • • u u
W V V
NEW TEI`� °C�.Af?Y • • G s v • w • • • Y Y
PARTITION
WALL OR PARTITION WITH
EXISTING DOOR TO REMAIN
— — — — —
EXISTING WALL OR
PARTITION TO BE REMOVED
WALL OR PARTITION WITH
EXISTING DOOR TO BE REMOVED
DEMOLITION SYMBOL'
O
(SEE DEMOLITION LEGEND)
=�
PLUMBING FIXTURES
"
LOCATION INDICATE EXTENT AND
DEMOLITION OF EXISTING SLAB
DENOTES EXISTING AREAS
OUTSIDE THE SCOPE OF WORK
�E E E
EXISTING ELECT. OUTLET
E
IV
EXISTING DATA OUTLET
E
EX15TING TELEPHONE OUTLET
E
J
EXISTING JUNCTION BOX
I HR FIRE / SMOKE RATED WALL
OR PARTITION
DEMOLITION NOTES
O1 REMOVE EXISTING BOARD INSULATION.
Q2 EXISTING METAL TUBES / PIPES TO
REMAIN - SEE MEP DRAWINGS FOR
ADDITIONAL INFORMATION.
40 FIELD INSPECT ALL EXISTING WALL
PENETRATIONS AND PATCH / REPAIR
ANY IF REQUIRED.
OEXISTING 2'x 4' LIGHTING FIXTURES
SHALL BE REMOVED AND RETURNED TO
OWNER.
OEXISTING EXP05ED CONCRETE ROOF
SLAB SHALL REMAIN. CONTRACTOR 15 TO
FIELD VERIFY CONDITIONS OF EXISTING
A/G DUCTS, PLUMBING LINES, FIRE
SPRINKLING SYSTEM, ETC.
OPROVIDE NEW DOOR ROUGH OPENING
FOR A NEW DOOR 4' -0" x "I' -0" x 11/4".
SEE DOOR SCHEDULE.
INTERIOR MMI)IFIOATIONS ONLY
(ANY EXTEFUOR MOMFICATION MAY PEQU "RE
A 60AnD AF('EAP-4.NCE)
OFME sUIL,DWG
B
0 r ul
rl
H
OUTPATRNT r
aGAPJ SURGERYING GE
77
PROJECT AREA
TMRD FLOOR S.W. 62ND AVENUE
KEY PLAN
- I
N.TS.
J
Y
•`
L
�u
Revision:
0
0
0
0
D
N
i
i
h �
1 �
E
i
o'
O
I
lad
O
I
i
i,
N
I�
C�
C
�o
M N
v
[Ln
A�
O
�X
x
F-
I-
w
N�
� M
�p N
n �
N
O
V H
O
�V
9
r
Q
V)
0 z w
0 < H
``az
I-za
>< 0ommim
V) r
<0z
w
�w0
< A
a
CONSTRUCTION
DOCUMENTS
DRAWN: GAC
CHECKED: LEN
DATE: 03 -12 -14
SCALE: AS SHOWN
SEAL
OF F40
Sheet No.
A -1
OF
17
I JOB # 201335 I
A