Loading...
14-375-003i -- THIS DRAWING IS ONL ,r TO 46515T IN SHOWING THE SCOPE OF DEMOLITION WORK AND IS NOT INTENDED TO INDICATE ALL DEMOLITION. CONTRACTOR SHALL REMOVE ALL EXISTING ITEMS AS REQUIRED TO COMPLETE THE JOB. 2.- NOT ALL ITEMS TO BE DEMOLISHED ARE SHOWN ON THE PLAN. CONTRACTOR SHALL BE RESPONSIBLE FOR PERFORMING A WALK -THRU OF THE PROJECT PRIOR TO SUBMITTING A BID TO THE OWNER FOR IDENTIFYING POSSIBLE CRITICAL ITEMS, NOT OR INCORRECTLY ADDRESSED, WHICH REQUIRE REMOVAL/ RELOCATION, 3.- PROVIDE SAFETY FEATURES DURING WORK AS CALLED FOR IN SPECS, APPLICABLE CODES, RULES AND REGULATIONS HAVING JURISDICTION OF THE PROJECT. 4.- CUT, REMOVE, PATCH, ALTER AND REFINISH EXISTING CONSTRUCTION AS REQUIRED TO LEAVE WORK COMPLETE AND IN SATISFACTORY MANNER 5.- CONTRACTOR IS TO PROTECT ALL UNDER - GROUND OR OTHER CONCEALED UTILITIES. HE IS TO INSPECT CEILING AND CHASES TO ASSURE PROPER IDENTIFICATION OF UTILITIES. MECHANICAL AND /OR ELECTRICAL CONTRACTOR ARE TO CAP THEM AS REQUIRED. G.- OPENINGS LEFT THROUGH RATED AND SMOKE PARTITIONS DUE TO REMOVAL OF DUCTWORK CONDUIT SHALL BE CLOSED (BOTH SIDES) 1- REMOVE ALL EXISTING ACOUSTICAL TILE CLG. AND SUSPENDED SYSTEMS IN THE RENOVATION AREA AS REQUIRED FOR INSTALLATION OF WORK TO BE DONE. COORDINATE REMOVAL WITH ELECTRICAL CONTRACTOR REGARDING EXISTING LIGHTING FIXTURES ETC.. REPLACE CEILING ACCORDINGLY AFTER COMPLETION OF WORK. GENERAL DEMOLITION NOTES. S -- CONTRACTOR IS TO SAW -CUT ALL OPENINGS IN 10.- CONTRACTOR IS TO COORDINATI~ CONCRETE BLOCK WALLS IF REQUIRED_ CONTRACTOR DEMOLITION WORK WITH ADMINISTRATION AND SHALL NOT DEMOLISH OPENINGS WITH SLEDGE IS TO GIVE SUFFICIENT ADVANCE NOTICE OF HAMMER UNTIL OUTLINES HAVE BEEN CUT. THE BEGINNING OF WORK IN EACH EXISTING FLOOR TO ADMINISTRATION (12 HOUR MINIMUM) 9.- RENOVATION WORK MAY ENTAIL INTERVENTIONS IN AREAS OUTSIDE OF THE IMMEDIATE SCOPE OF WORK, INCLUDING WORK ABOVE AND /OR BELOW THE FLOOR LEVEL WITHIN THE SCOPE. IT MAY REQUIRE WORK INVOLVING REMOTE UTILITY LINES (ELECTRICAL MECHANICAL, PLUMBING, COMMUNICATIONS). ANY WORK IN AREAS OUTSIDE OF THE IMMEDIATE SCOPE OF WORK SHALL BE ALL - INCLUSIVE, PROVIDING ALL STRUCTURES, UTILITIES, FINISHES AND EQUIP. REQUIRED TO RESTORE THE AREA TO FULLY OPERATIONAL CONDITIONS, TO FULLY COMPLYING RATING INTEGRITY, AND TO MEET OWNER'S APPROVAL ALL WORK AS DESCRIBED IN THIS NOTE IS TO BE PART OF THE BASE CONTRACT PRICE, OR CONTRACT CONTINGENCY ALLOWANCE FOR SUCH WORK. iL- CONTRACTOR SHALL VERIFY EXACT LOCATION OF EXISTING CONCRETE COLUMNS IN AREAS WHERE WALLS ARE BEING REMOVED AND INFORM ARCHITECT OF ANY CONFLICTS BEFORE ANY WALLS ARE REMOVED SO THAT A/E CAN INSPECT THEM FOR CLARIFICATION PRIOR TO PROCEEDING WITH WORK. 13.- DEMOLITION IS DENOTED BY BROKEN LINES. 14.- FOR REMOVAL OF FIXTURES AND EQUIPMENT SEE ARCHITECTURAL, PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS. PREPARE EXISTING CONCRETE 6L4545 REQ. BY GRINDING, LEVELING WITH ARDEX LEVELER AS PER MANUFACTURERS SPECIFICATIONS. MATCH EXISTING SLAB ELEVATION AS REQUIRED TO RECEIVE NEW SCHEDULED FLOORING MATERIAL. I&.- VERIFY WITH CIVIL, PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS, ITEMS TO BE REMOVED /RELOCATED IN CASE OF CONFLICT. 12.- PATCH AND REPAIR ALL EXISTING SURFACES DAMAGED BY DEMOLITION AND /OR INSTAL- )I.- DESTINATION OF ALL EXISTING EQUIPMENT, LATION OF NEW ELECTRICAL CONDUITS, GAS PIPING, ETC.. AS REQUIRED TO MATCH PLUMBING FIXTURES, DOORS AND FRAMES, ETC. ADJACENT SURFACES AND /OR AS REQUIRED TO BE REMOVED SHALL BE COORDINATED FOR NEW SCHEDULED FINISHES, WITH THE OWNER. 18.- CONTRACTOR TO SURVEY PROJECT AREA PRIOR TO COMMENCEMENT OF WORK. NOTE AND REPAIR ANY DAMAGE TO AREAS WHERE WORK IS GOING TO BE PERFORMED. NOTIFY OWNER AND ARCHITECT WITH A LIST OF WORK PRIOR TO CONTRACT. 19•- THIS SET OF DRAWINGS IS TO BE USED AS A UNIT CONTRACTOR IS RESPONSIBLE FOR ALL DISCIPLINES t SHOULD INCLUDE EVERYTHING THAT IS NEEDED FOR MAKING ALL SYSTEMS WORK. EXAMPLE. IF A SINK IS SHOWN IN THE ARCHITECTURAL PLANS, IT IS ASSUMED THAT THE G.C. IS PROVIDING EVERYTHING NEEDED, A/E WILL PROVIDE THEM WITH THE UNDERSTANDING THAT THERE WILL BE NO ADDITIONAL COST TO OWNER. PARTIAL SIXTH FLOOR DEMOLITION PLAN SCALE: 1/4" = V -0- 606- WE Y V W V V U V Duo u Y E V DEMOLITION 13 EX15TING RFINF�-)RCED GONC,. • COLUMN 0lf, f_-C 1GRiW Tt_ WALY • ` TO REMAIN •: � � W U V G Y • EXISTING WALL OR PARTITION TO REMAIN vs• V:+wv• W v V Y • V Yu • a • • • u u W V V NEW TEI`� °C�.Af?Y • • G s v • w • • • Y Y PARTITION WALL OR PARTITION WITH EXISTING DOOR TO REMAIN — — — — — EXISTING WALL OR PARTITION TO BE REMOVED WALL OR PARTITION WITH EXISTING DOOR TO BE REMOVED DEMOLITION SYMBOL' O (SEE DEMOLITION LEGEND) =� PLUMBING FIXTURES " LOCATION INDICATE EXTENT AND DEMOLITION OF EXISTING SLAB DENOTES EXISTING AREAS OUTSIDE THE SCOPE OF WORK �E E E EXISTING ELECT. OUTLET E IV EXISTING DATA OUTLET E EX15TING TELEPHONE OUTLET E J EXISTING JUNCTION BOX I HR FIRE / SMOKE RATED WALL OR PARTITION DEMOLITION NOTES O1 REMOVE EXISTING BOARD INSULATION. Q2 EXISTING METAL TUBES / PIPES TO REMAIN - SEE MEP DRAWINGS FOR ADDITIONAL INFORMATION. 40 FIELD INSPECT ALL EXISTING WALL PENETRATIONS AND PATCH / REPAIR ANY IF REQUIRED. OEXISTING 2'x 4' LIGHTING FIXTURES SHALL BE REMOVED AND RETURNED TO OWNER. OEXISTING EXP05ED CONCRETE ROOF SLAB SHALL REMAIN. CONTRACTOR 15 TO FIELD VERIFY CONDITIONS OF EXISTING A/G DUCTS, PLUMBING LINES, FIRE SPRINKLING SYSTEM, ETC. OPROVIDE NEW DOOR ROUGH OPENING FOR A NEW DOOR 4' -0" x "I' -0" x 11/4". SEE DOOR SCHEDULE. INTERIOR MMI)IFIOATIONS ONLY (ANY EXTEFUOR MOMFICATION MAY PEQU "RE A 60AnD AF('EAP-4.NCE) OFME sUIL,DWG B 0 r ul rl H OUTPATRNT r aGAPJ SURGERYING GE 77 PROJECT AREA TMRD FLOOR S.W. 62ND AVENUE KEY PLAN - I N.TS. J Y •` L �u Revision: 0 0 0 0 D N i i h � 1 � E i o' O I lad O I i i, N I� C� C �o M N v [Ln A� O �X x F- I- w N� � M �p N n � N O V H O �V 9 r Q V) 0 z w 0 < H ``az I-za >< 0ommim V) r <0z w �w0 < A a CONSTRUCTION DOCUMENTS DRAWN: GAC CHECKED: LEN DATE: 03 -12 -14 SCALE: AS SHOWN SEAL OF F40 Sheet No. A -1 OF 17 I JOB # 201335 I A