MEP Engineer of Record
Randall A. Nelson, P. E.
14817 West 95th Street
Lenexa, Kansas 66215
Phone 913 322 5150
a�
a
TA
PETCO ANIMAL MIAMI DADE ADOPTION CENTER
SUPPLIES STORES, INC. 6200 SOUTH DIXIE HWY
654RKANDF6LLSDRNE A
SAN SOUTH MIAMI, FL 33143
NTONIO, TEXAS 78245
3N
ELECTRICAL PLAN
REF.:
NOTES FOR -THIS DRAINING-_-
1. ALL DEVICES NOT SPECIFICALLY DIMENSIONED MAY BE LOCATED +/-
8" IN EITHER -D _-REr jTlnly =1N ':'I:AN _F-'ROTA -THEIR APPROPRIATE LOCATION
SHOWN (TO KE,1RFST STJD VR NE rRESi' CMU CORE). ALL
DIMENSIONS FROM INSIDE FACE OF UNFINISHED WALL.
2. VERIFY LOCATION OF" ALL DEVICES, = C NER POLES, ETC., WITH LATEST
FIXTURE PLAN.- -
3. ALL JUNCTION BOXES INSTALLED EXPOSED ON SALES FLOOR AND
WALL MOUNTED BELOW 7' -0" AFF SHALL BE DIE —CAST ALUMINUM
WEATHERPROOF JUNCTION BOXES WITH 3/4" INLETS ON
TOP /BOTTOM /BACK ONLY, BELL 5386 SERIES OR EQUAL.
4. ALL LIGHTING FIXTURES IN THE CORRIDOR CONTROLLED THROUGH THE
EMS LIGHTING CONTROL SYSTEM.
5. PROVIDE UNSWITCHED LEG FROM SAME CIRCUIT AHEAD OF
CONTACTOR FOR FIXTURES WITH EMERGENCY BALLASTS. FIXTURES TO
BE CONTROLLED BY EMS OR LOCAL SWITCH AND NOT TO BE NIGHT
LIGHTS UNLESS OTHERWISE NOTED.
6. CONNECT BRANCH CIRCUITS TO LIGHTING FIXTURES AS INDICATED ON
PLANS AND PANELBOARD SCHEDULES WITH #12 MINIMUM CONDUCTORS
IN CONCEALED RACEWAYS. CONDUCTOR SIZES AND QUANTITIES
OTHER THAN #12 AWG SHALL BE AS NOTED. ALL FINAL
CONNECTIONS TO SHALL BE WITH FLEXIBLE METAL CONDUIT.
I KEYNOTES (SYMBOLS 0, 0 ETC.) I
1. CIRCUIT NEW LIGHT FIXTURES TO EXISTING SPARE 120V, 20A CIRCUIT
IN EXISTING PANELBOARD. - CIRCUIT IS TO BE CONTROLLED VIA EMS
SYSTEM. FIELD VERIFY EXACT CIRCUIT AND PANELBOARD IN FIELD.
VERIFY CONTROL REQUIREMENTS WITH PETCO PM AND CIRCUIT VIA
EMS CONTACTOR AS REQUIRED. CIRCUIT EXIT SIGNS AND EMERGENCY
BALLASTS ON SAME CIRCUIT AS ADJACENT LIGHT FIXTURES, AHEAD
OF ANY MEANS OF CONTROL.
2. RELOCATE EXISTING LIGHTING FIXTURE /DEVICE TO THIS LOCATION.
3. DATA OUTLET IN 2 "X4 "X2" JUNCTION BOX WITH 3/4" CONDUIT AND PULL
STRING TO ABOVE CEILING.
4. TELEPHONE OUTLET IN 2 "X4 "X2" JUNCTION BOX WITH 3/4" CONDUIT AND
PULL STRING TO ABOVE CEILING.
5. EXISTING LIGHTS, EMERGENCY LIGHTS, AND EXIT SIGNS IN THIS AREA TO
REMAIN.
6. PROVIDE ONE 4X4X2 JUNCTION BOX FOR REMOTE TEST /RESET
STATION FOR SMOKE DETECTORS AT 7' -0" AFF DIRECTLY ABOVE
TEMPERATURE SENSOR FOR HVAC UNIT. REFER TO SHEET M2.1 FOR
SENSOR LOCATION. ELECTRICAL CONTRACTOR TO PROVIDE THE
5 —WIRE INTERCONNECTION BETWEEN THE TEST /RESET STATIQN",AND,
THE SMOKE DETECTOR PER MANUFACTURER'S INSTALLATI0*�•
INSTRUCTIONS.
7. PROVIDE 1" FLEXIBLE CONDUIT FROM DUCT DETECTOR POW MODULE,'
IN RTU TO SINGLE GANG JUNCTION BOX AT BAR JOIST LEVfftiFOR ' -�
FIRE ALARM RELAY MODULE.a
8. CIRCUIT NEW RECEPTACLE TO EXISTING SPARE 120V, 20A CIRCUIT
EXISTING PANELBOARD 'G1'. PROVIDE NO MORE THAN (1) RECEPTACLE
PER 20A CIRCUIT FOR DEDICATED CIRCUIT. FIELD VERIFY EXACT
CIRCUIT AND PANELBOARD.
9. CIRCUIT NEW RECEPTACLES TO EXISTING SPARE 120V, 20A CIRCUIT IN
EXISTING PANELBOARD 'G1'. PROVIDE NO MORE THAN (6)
RECEPTACLES PER 20A CIRCUIT. FIELD VERIFY EXACT CIRCUIT AN
3 PANELBOARD IN FIELD.
Fi'G1q'FIE§LD WIRE CORD KIT FOR ELECTRIC DRYER AND MATCHING
R RECEPTACLE. PROVIDE AND CIRCUIT NEW RECEPTACLE
, 208V, 2P CIRCUIT BREAKER IN EXISTING PANELBOARD
VERIFY EXACT CIRCUIT AND PANELBOAR D IN FIELD.
11. CIRCUIT NEW RTU WP /GFCI RECEPTACLE ALONG WITH THE EXISTING
TO REMAIN RTU CONVENIENCE RECEPTACLES.
12. PROVIDE 60A, 208V, 3P FUSED SWITCH WITH 60A RATED FUSE IN
EXISTING 208V DISTRIBUTION BOARD FOR NEW RTU. PROVIDE (3) #6,
(1) #10G IN 1 "C FROM 60A, 3P FUSED SWITCH IN DISTRIBUTION BOARD
TO FACTORY FURNISHED LOCAL DISCONNECT AT RTU. MAKE ALL
CONNECTIONS FOR A COMPLETE INSTALLATION. VERIFY ALL
REQUIREMENTS WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH -IN.
02 KEY PLAN 01
1/4"= V-0" REF.: I NO SCALE
DISTRIBUTION:
DATE:
DISTRIBUTION:
DATE:
DISTRIBUTION:
DATE:
DISTRIBUTION:
DATE:
AC ERTUS JOB#
99% SUBMISSION
12 -04-13
1320336
100% PERMIT SUBMISSION
12 -11 -13
PETCOP.M.JOB#
BUILDING DEPT COMMENTS
01 -27 -14
1794
ADDENDUM #1
01 -31 -14
DRAWN.
ADDENDUM #2
02 -26-14
JH /JMMITJA
CHECKED:
BJT
DRAWING TITLE: is I
ELECTRICAL
PLAN
E2.1
:2-1
I
wi