14-1187-004GENERAL FINISH NOTES 1. REFER TO SPECIFICATIONS FOR ALL PERFORMANCE AND QUALITY GUIDELINES AND FOR ADDITIONAL SUBMITTAL INFORMATION. 2. INTERIOR FINISH MATERIALS AND THE INSTALLATION PROCESS SHALL BE IN COMPLIANCE WITH ALL LOCAL GOVERNING CODES INCLUDING BUT NOT LIMITED TO FLAMMABILITY RATINGS AND VOLATILE ORGANIC COMPOUND REQUIREMENTS. ALL INTERIOR FINISHES SHALL MEET THE REQUIREMENTS OF NFPA 101, CHAPTER 10.2.2. 3. THE GENERAL CONTRACTOR SHALL INSPECT ALL SURFACES SCHEDULED TO RECEIVE NEW MATERIAL AND VERIFY THAT CONDITIONS ARE SUITABLE FOR APPLICATION OF FINISH MATERIAL PRIOR TO INSTALLATION INCLUDING, BUT NOT LIMITED TO, PROVIDING A SURFACE THAT IS DRY, CLEAN AND FREE OF OIL, GREASE, MILDEW, LOOSE AND FLAKING PAINT AND OR ANY OTHER FOREIGN SUBSTANCES. IF NOT, CONTACT INSIGHT DESIGN FOR DIRECTION. 4. TYPICAL PAINTED WALL FINISHES SHALL BE ONE (1) COAT LATEX PRIMER WITH MINIMUM OF THREE (3) COATS OF SPECIFIED PRODUCT, EGGSHELL FINISH. REFER TO FINISH LEGEND FOR SPECIFIC FINISH. WHERE NEW PARTITION MEETS EXISTING PARTITION IN THE SAME PLANE, THE ENTIRE PLANE SHALL BE PAINTED. CONTRACTOR SHALL SUBMITTHREE (3) 12" X 12" GYPSUM BOARD SAMPLES OF EACH SCHEDULED PAINT COLOR TO INSIGHT DESIGN FOR APPROVAL PRIOR TO APPLICATION. SAMPLE IS TO REPRESENT FINISH SHEEN, TEXTURE, AND NUMBER OF COATS OR APPLICATIONS AS SPECIFIED. EACH SAMPLE IS TO BE LABELED BY THE CORRESPONDING FINISH PLAN KEYNOTE AND PAINT SPECIFICATION. 5. THE GENERAL CONTRACTOR SHALL INSPECT PREMISES AND INCLUDE ALL FLOOR PREPARATION INCLUDING, BUT NOT LIMITED TO, FILLING, LEVELING, GRINDING, CLEANING, ETC. FOR INSTALLATION OF SPECIFIED FLOOR COVERING. 6. FLOORING TRANSITIONS SHALL OCCUR AT CENTERLINE OF DOOR OR OPENING UNLESS NOTED OTHERWISE. 7. THE GENERAL CONTRACTOR SHALL PROVIDE HARD RUBBER TRANSITION STRIP BETWEEN CARPET AND RESILIENT FLOORING. COLOR SHALL BE SELECTED BY ARCHITECT FROM MANUFACTURER'S STANDARD SELECTION. 8. THE GENERAL CONTRACTOR SHALL SUPPLY THREE (3) SAMPLES OF EACH FLOOR COVERING SPECIFIED PRIOR TO INSTALLATION. EACH SAMPLE SHALL BE LABELED WITH THE CORRESPONDING FINISH PLAN KEY NOTE AND SPECIFICATION. SAMPLES SHALL BE REPRESENTATIVE OF ALL DYE LOTS WHICH ARE TO BE USED ON THE PROJECT. 9. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR CROSS- REFERENCING FINISH NOTES BETWEEN PLANS AND ELEVATIONS. IF A DISCREPANCY IS FOUND, IMMEDIATELY NOTIFY INSIGHT DESIGN FOR INSTRUCTION. 10. THE GENERAL CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY SURFACES NOT HAVING A FINISH SPECIFIED PRIOR TO SUBMITTING FINISH BID. 11, THE GENERAL CONTRACTOR IS TO PROVIDE FLOOR LEVELING AS REQUIRED. PROVIDE FLOOR TOLERANCES ACCEPTABLE FOR FLOORING INSTALLATION AS REQUIRED BY THE FEDERAL A.D.A. LAW AND MFG. SPECIFICATIONS. 12, WALL BASE AT MILLWORK TOE KICK SPACE TO BE 4" HIGH AND TO MATCH H.P.L. ON MILLWORK U.O.N. 13. REFER TO ELEVATIONS FOR ADDITIONAL FINISH INFORMATION RELATING TO ALL MILLWORK. 14. ALL FIRE EXTINGUISHERS CABINETS TO BE PAINTED TO MATCH ADJACENT WALL. 15, THE GENERAL CONTRACTOR SHALL VERIFY THAT ALL FINISHES MATCH EXISTING FINISHES. GENERAL CONTRACTOR SHALL NOTIFY INSIGHT DESIGN IMMEDIATELY OF ANY DISCREPANCIES SHOWN ON THE FINISH PLAN AND /OR FINISH SCHEDULE. 16. CARPET SEAMING DIAGRAMS SHALL BE SUBMITTED BY THE CARPET INSTALLER TO INSIGHT DESIGN FOR REVIEW PRIOR TO INSTALLATION. 17. ALL WORK BY OTHERS SHALL BE ADEQUATELY PROTECTED AGAINST DAMAGE FROM PAINTING AND FROM THE APPLICATION OF VARIOUS ADHESIVES USED IN INSTALLING WALL COVERINGS ON COMPLETION, ALL OTHER WORK SHALL BE FREE OF DAUBS, SPOTS AND SPLATTERS OF PAINT AND ADHESIVES. 18. DO NOT BRIDGE BUILDING EXPANSION AND CONTROL JOINTS WITH STEEL FRAMING OR FURRING MEMBERS. INDEPENDENTLY FRAME BOTH SIDES OF JOINTS WITH FRAMING OR FURRING MEMBERS AS INDICATED. GYPSUM BOARD 1. GYPSUM BOARD CONSTRUCTION TERMINOLOGY: REFER TO ASTM C11 AND GA-505 FOR DEFINITIONS OF TERMS RELATED TO GYPSUM BOARD ASSEMBLIES NOT DEFINED IN THIS SECTION OR IN OTHER REFERENCED STANDARDS. 2. SOUND TRANSMISSION CHARACTERISTICS: WHERE INDICATED, PROVIDE ASSEMBLIES TESTED FOR STC RATINGS PER ASTM E 90 AND CLASSIFIED ACCORDING TO ASTM E 413 BY AN INDEPENDENT TESTING AGENCY. 3. FIRE TEST RESPONSE CHARACTERISTICS: WHERE INDICATED, PROVIDE ASSEMBLIES TESTED FOR FIRE RESISTANCE PER ASTM E 119. 4. ANY BOARD THAT HAS BECOME WET AT ANY POINT PRIOR TO THE DATE OF SUBSTANTIAL COMPLETION SHALL BE REPLACED, INCLUDING BOARD THAT HAS BEEN INSTALLED AND FINISHED. 5. PROVIDE GYPSUM BOARD OF TYPES INDICATED IN MAXIMUM LENGTHS AVAILABLE, MINIMIZING JOINTS. • THICKNESS: PROVIDE GYPSUM BOARD %" THICK TO COMPLY WITH ASTM C 840 FOR APPICATION SYSTEM AND SUPPORT SPACING INDICATED. 6. GYPSUM WALLBOARD: ASTM C 1396 AND AS FOLLOWS: • TYPE X. MR TYPE X WHERE INDICATED • EDGES: TAPERED 7. GLASS MAT WATER RESISTANT TILE BACKER: ASTM C 1178 8. INTERIOR TRIM: ASTM C 1047 9. STEEL DRILL SCREWS COMPLYING WITH ASTM C 1002 FOR THE FOLLOWING APPLICATIONS: • FASTENING GYPSUM BOARD TO STEEL MEMBERS LESS THAN 0.03" THICK. • FASTENING GYPSUM BOARD TO GYPSUM BOARD. • STEEL DRILL SCREWS COMPLYING WITH ASTM C 954 FOR FASTENING GYPSUM BOARD TO STEEL MEMBERS FROM 0.033" TO 0.112" THICK. 10. APPLYING AND FINISHING GYPSUM BOARD: COMPLY WITH ASTM C 840. 11. FORM CONTROL JOINTS AND EXPANSION JOINTS WITH SPACE BETWEEN EDGES OF ADJOINING GYPSUM PANELS, AS WELL AS SUPPORTING FRAMING BEHIND GYPSUM PANELS. • PARTITIONS: PROVIDE VERTICAL CONTROL JOINTS SPREAD NOT MORE THAN 30' -0" ON CENTER IN PARTITIONS. • CEILINGS: PROVIDE CONTROL JOINTS LIMITING AREAS TO 2500 SQUARE FEET WITH THE LONGEST DISTANCE BEING 50' -0 ". 12. LEVELS OF GYPSUM BOARD FINISH: PROVIDE THE FOLLOWING LEVELS OF GYPSUM BOARD FINISH PER GA 214. • LEVEL 0: FOR TEMPORARY CONSTRUCTION ONLY. • LEVEL 1: FOR PLENUM AREAS ABOVE CEILINGS, ATTICS AND AREAS WHERE THE ASSEMBLY IS CONCEALED. • LEVEL 2: FOR AREAS WHERE TILE BACKING BOARD (ASTM C630) IS USED AS A SUBSTRATE FOR TILE ONLY. • LEVEL 3: FOR AREAS TO RECEIVE HEAVY TEXTURED, THICK ('/8" OR GREATER) WALL COVERINGS. • LEVEL 4: FOR TEXTURED FINISHES, WALL COVERINGS AND PAINTED FINISHES. TILING 1. SUBMIT COLOR SAMPLES SHOWING THE FULL RANGE OF COLORS, TEXTURES AND PATTERNS IN ALL PRICE GROUPINGS. INCLUDE SAMPLES OF ACCESSORIES INVOLVING COLOR SELECTION. 2. STATIC COEFFICIENT OF FRICTION ON WALKWAY SURFACES: PROVIDE THE FOLLOWING VALUES AS DETERMINED BY ASTM C 1028: • FLAT SURFACES: MINIMUM 0.6 • STEP TREADS: MINIMUM 0.6 • RAMP SURFACES: MINIMUM 0.8 3. ANSI CERAMIC TILE STANDARD: PROVIDE TILE THAT COMPLIES WITH ANSI A137.1, "SPECIFICATION FOR CERAMIC TILE," FOR TYPES, COMPOSITIONS AND OTHER CHARACTERISTICS INDICATED. 4. LATEX PORTLAND CEMENT MORTAR: ANSI A118.4 • MIXTURE OF DRY MORTAR MIX AND LATEX ADDITIVE: MIXTURE OF PREPACKAGED DRY MORTAR MIX AND LIQUID ACRYLIC LATEX ADDITIVE. • FOR WALL APPLICATIONS, PROVIDE NON - SAGGING, LATEX PORTLAND CEMENT MORTAR COMPLYING WITH ANSI A118.4, SECTION F- 2.1.2. 5. STANDARD SANDED CEMENT GROUT: ANSI A118.6, FOR JOINTS Ys" OR WIDER. 6. STANDARD UN- SANDED CEMENT GROUT: ANSI A118.6, FOR JOINTS LESS THAN 78" 7. LATEX PORTLAND CEMENT GROUT: ANSI A118.6 FOR MATERIALS DESCRIBED IN SECTION H -2.4 COMPOSED AS FOLLOWS: • MIXTURE OF SANDED DRY GROUT MIX AND LATEX ADDITIVE: MIXTURE OF FACTORY PREPARED, DRY GROUT MIX AND LIQUID ACRYLIC LATEX ADDITIVE. 8. LATEX UNDER- LAYMENT: QUICK SET TYPE, AS RECOMMENDED BY MEMBRANE MANUFACTURER, AS REQUIRED TO PROVIDE POSITIVE DRAINAGE TO FLOOR DRAINS. 9. MARBLE THRESHOLDS: WHITE, HONED MARBLE COMPLYING WITH MIA GROUP "A" REQUIREMENT FOR SOUNDNESS; ASTM C 503 ABRASION RESISTANCE WHERE EXPOSED TO FOOT TRAFFIC, A MINIMUM HARDNESS OF 10 PER ASTM C 241. • MORTAR: ASTM C270, TYPE S. • ADHESIVE: LATEX MODIFIED THIN SET MORTAR. 10. EXPANSION JOINTS: IF NOT INDICATED ON THE DRAWINGS, EXPANSION JOINTS SHALL BE INSTALLED IN ACCORDANCE WITH THE TILE COUNCIL OF NORTH AMERICA, INC. HANDBOOK FOR CERAMIC TILE INSTALLATION, LATEST EDITION, AS FOLLOWS: • INTERIOR: 20' TO 25' IN EACH DIRECTION. • INTERIOR TILEWORK EXPOSED TO DIRECT SUNLIGHT OR MOISTURE: 8' TO 12' IN EACH DIRECTION. • WHERE TILEWORK ABUTS RESTRAINING SURFACES SUCH AS PERIMETER WALLS, DISSIMILAR FLOORS, CURBS, COLUMNS, PIPES, CEILINGS AND WHERE CHANGES OCCUR IN BACKING MATERIALS. • ALL EXPANSION, CONTROL, CONSTRUCTION AND COLD JOINTS IN THE STRUCTURE SHALL CONTINUE THROUGH THE TILEWORK INCLUDING SUCH JOINTS AT VERTICAL SURFACES. • JOINTS THROUGH THE TILEWORK DIRECTLY OVER STRUCTURAL JOINTS SHALL NEVER BE NARROWER THAN THE STRUCTURAL JOINT. • JOINTS AT PERIMETER OF EACH SPACE WHERE NO FIELD JOINTS ARE DETAILED. 11. CLEAVAGE MEMBRANE: ASPHALT FELT, ASTM D 226, TYPE 1(NO.15) WITH 3 OVERLAPS AT ALL SEAMS. INSTALL CLEAVAGE MEMBRANE UNDER 100% OF TILE ON SLAB -ON- GRADE. 12. CLEAN ROUGH CONCRETE SLAB SURFACE OF DRIPPINGS AND OTHER DEBRIS. ROUGHEN SURFACE IF NECESSARY. WASH THOROUGHLY WITH CLEAN WATER PERMITTING CONCRETE TO BECOME SATURATED. SLUSH WITH NEAT CEMENT GROUT TO INSURE GOOD BOND. • NEUTRALIZE ANY TRACE OF STRONG ACID OR ALKALI (PH LEVEL 7 TO 9). 13. WHEN NECESSARY BECAUSE OF UNEVENNESS OR ROUGHNESS OF BASE, OR TO BRING TILE TO PROPER FLATNESS, INSTALL LEVELING COAT AND PERMIT TO SET AND HARDEN, WET CURE. 14. PROVIDE TAPE REINFORCEMENT AT JOINTS INCLUDING INSIDE CORNERS AND OUTSIDE CORNERS. 15. JOINT WIDTH: 1/8" WIDE, U.O.N. 16. COMPLY WITH PARTS OF ANSI A 108 SERIES OF TILE INSTALLATION STANDARDS IN "SPECIFICATIONS FOR INSTALLATION OF CERAMIC TILE" THAT APPLY TO TYPES OF SETTING AND GROUTING MATERIALS AND TO METHODS INDICATED IN CERAMIC TILE INSTALLATION SCHEDULES. • CONCRETE SUB - FLOORS: NEW SLABS ON GRADE (THIN SET METHOD): TCNA F113 DRY SET MORTAR WITH TILE INSTALLATION SPECIFICATION ANSI A108.5. • WALLS: GYPSUM BOARD (THIN SET METHOD): TCNA W223 ORGANIC ADHESIVE; WITH TILE INSTALLATION SPECIFICATION ANSI A108.4. 17. SOUND EACH TILE AFTER SET. REPLACE ALL TILES SOUNDING HOLLOW. 18. INSTALL STONE THRESHOLDS AT LOCATIONS INDICATED; SET IN SAME TYPE OF SETTING BED AS ABUTTING FIELD TILE. USE LATEX PORTLAND CEMENT MORTAR FOR LOCATIONS WHERE MORTAR BED WOULD OTHERWISE BE EXPOSED ABOVE ADJACENT NON -TILE FLOOR FINISH. PAINTING 1. SUBMIT A COMPLETE CURRENT COLOR CHIP CATALOG FOR COLOR SELECTION. 2. ATTIC STOCK: ONE UNOPENED GALLON OF EACH COLOR USED. 3. MEASURE MOISTURE CONTENT OF SURFACES. DO NOT APPLY FINISHES UNLESS SURFACES ARE BELOW MAXIMUMS RECOMMENDED. ABBREVIATIONS ADDL. ADDITIONAL F.A. FIRE ALARM O.C. ON CENTER A.F.F. ABOVE FINISHED F. D. FLOOR DRAIN O.D. OUTSIDE DIAMETER FLOOR F.E.C. FIRE EXTINGUISHER OFF. OFFICE A.P. ACCESS PANEL Ln CABINET O.H. OVERHEAD APPROX. APPROXIMATE F. F. FINISH FLOOR OPP. OPPOSITE ARCH. ARCHITECTURAL F.H.C. FIRE HOSE CABINET M A.V. AUDIOVISUAL PL. PLATE N � [0 � FIN. FINISH PLAS. PLASTER BLK'G BLOCKING FIXT. FIXTURE PLY. PLYWOOD BLDG BUILDING FL. FLOOR PT. PAINT FLOUR. FLUORESCENT BLK BLOCK FOLD. FOLDING REF. REFRIGERATOR BM. BEAM F.P. FIRE PROOF R.B. RUBBER BASE BOT. BOTTOM FR. FRAME REC. RECESSED CAB. CABINET FSC. FASCIA REINF. REINFORCED CEM. CEMENT FUR. FURRING REQ'D. REQUIRED C.J. CONTROLJOINT RM. ROOM CENTER LINE GA. GAUGE CLG. CEILING G.B. GRAB BAR SDP. SOUND PROOF CLR. CLEARANCE G.C. GENERAL CONTRACTOR SECT. SECTION C.M.U. CONCRETE MASONRY GL. GLASS SPEC. SPECIFICATION UNIT GR. GRILLE SPK. SPEAKER CONC. CONCRETE G.W.B. GYPSUM WALL BOARD SPRKL. SPRINKLER COL. COLUMN S.S. STAINLESS STEEL CONN. CONNECTION H HANDICAPPED STD. STANDARD CONST, CONSTRUCTION HODW W HARDWARE STOR. STORAGE CONT. CONTINUOUS HOR. HORIZONTAL STRUC. STRUCTURAL CONTR. CONTRACTOR H.P. HIGH POINT SUSP. SUSPENDED CONY. CONVECTOR H.P.L. HIGH PRESSURE SYM. SYMMETRICAL CORR. CORRIDOR LAMINATE SHT. SHEET CPT. CARPET HR. HAND RAIL CSK. COUNTERSINK HVAC HEATING/VENTILATION TEL. TELEPHONE C.T. CERAMIC TILE AIR CONDITIONING THRSH. THRESHOLD CTR. COUNTER H.C. HUNG CEILING THK. THICK(NESS) HT. HEIGHT TK.BD. TACK BOARD DET. DETAIL T.O.S. TOP OF SLAB INSUL. INSULATION D.F. DRINKING FOUNTAIN INT. INTERIOR TYP. TYPICAL DIA. DIAMETER TEMP. TEMPERED DIFF. DIFFUSER J.C. JANITOR'S CLOSET U.O.N. UNLESS OTHERWISE DIM. DIMENSION JT. JOINT NOTED DN. DR. DOWN DOOR LAV. LAVATORY UNDERSIDE D.W. DISH WASHER L.D. LINEAR DIFFUSER VA VAR. VARIES DWG. DRAWING L.P. LOW POINT LT. LIGHT V.C.T. VINYL COMPOSITE EA. EACH TILE EL. ELEVATION MFR. MANUFACTURER VERT. VERTICAL E.C. ELECTRICAL CLOSET MAR, MARBLE VEST. VESTIBULE ENC. ENCLOSURE MAT. MATERIAL V.F. VINYL FABRIC EQ. EQUAL MAX. MAXIMUM V.I.F. VERIFY IN FIELD EQUIP. EQUIPMENT MECH. MECHANICAL E.W.C. ELECTRIC WATER MET. METAL W/ WITH COOLER MIN. MINIMUM W/O WITHOUT EXIST. EXISTING WD WOOD EXH. EXHAUST N.I.C. NOT IN CONTRACT WD.BLK WOOD BLOCKING EXP.BT. EXPANSION BOLT N.T.S. NOT TO SCALE WOM WOMEN EXT. EXTERIOR W.P. WATERPROOFING 1 `1 GENERAL DOOR & HARDWARE NOTES DOORS 1. ALL EXISTING AND EXISTING RELOCATED PAINTED GRADE DOORS NEED TO BE SANDED, PATCHED AND PREPARED TO RECEIVE NEW HARDWARE AND FINISH. REFER TO FINISH SCHEDULE. 2. DOOR OPERATION AND EXIT HARDWARE MUST COMPLY WITH FBC 2010 AND ACCESSIBILITY CODE AS FOLLOWS: • EGRESS DOORS SHALL BE READILY OPERABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. • EGRESS DOOR HARDWARE: DOOR HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES ARE REQUIRED TO BE ACCESSIBLE AND SHALL NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TO OPERATE. LEVER OPERATED MECHANISMS, PUSH -TYPE MECHANISMS AND - D E HARDWARE U SHAPED HANDLES ARE ACCEPTABLE DESIGNS. WHERE DOOR HARDWARE IS NEW TO MATCH BUILDING STANDARD, G.C. TO VERIFY THAT EXISTING MEETS THIS CRITERIA. • MANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS ARE NOT PERMITTED. ALL HARDWARE MUST BE DIRECT ACTING REQUIRING NO MORE THAN ONE OPERATION. 3. PANIC AND FIRE EXIT HARDWARE: WHERE PANIC HARDWARE AND FIRE EXIT HARDWARE IS INSTALLED, IT SHALL COMPLY WITH THE FOLLOWING: • THE ACTUATING PORTION OF THE RELEASING DEVICE SHALL EXTEND AT LEAST ONE -HALF OF THE DOOR LEAF WIDTH. • A MAXIMUM UNLATCHING FORCE OF 15 POUNDS (67N). • ALL DOORS IN I HR. RATED CORRIDOR WALLS NEED TO BE 20 MIN. RATED. G.C. TO VERIFY THAT EXISTING PUBLIC CORRIDOR DOORS MEETTHIS CRITERIA. • HARDWARE HEIGHT: A LATCH OR OTHER FASTENING DEVICE ON A DOOR SHALL BE PROVIDED WITH A RELEASING DEVICE HAVING AN OBVIOUS METHOD OF OPERATION UNDER ALL LIGHTING CONDITIONS. THE RELEASING MECHANISM FOR ANY LATCH SHALL BE LOCATED AT LEAST 34" AND NOT MORE THAN 48" A.F.F. DOORS SHALL BE OPERABLE WITH NOT MORE THAN ONE RELEASING OPERATION. • MANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS ARE NOT PERMITTED. ALL HARDWARE MUST BE DIRECT ACTING REQUIRING NO MORE THAN ONE OPERATION. • DOOR OPENING FORCE: THE MAXIMUM FORCE FOR PUSHING OR PULLING OPEN AN INTERIOR HINGED DOOR IS 5 LBS (22.2N). HARDWARE 1. ALL HARDWARE SHALL MEETTHE REQUIREMENTS OF FEDERAL, STATE AND LOCAL CODES HAVING JURISDICTION OVER THIS PROJECT, NOTWITHSTANDING ANY REAL OR APPARENT CONFLICT HEREWITH IN THESE SPECIFICATIONS. 2. ALL LOCKS AND CYLINDERS SHALL BE FACTORY GRAND MASTERKEYED TO A NEW HARDWARE SYSTEM AS DIRECTED BYTHE OWNER, EXTERIOR LOCKS AND CYLINDERS SHALL BE FURNISHED WITH REMOVABLE CORE PRIMUS LEVEL 3 CYLINDERS FURNISHED IN A CLASSIC KEYWAY DIRECTED BY THE OWNER. 3. DOOR STOPS SHALL BE FURNISHED FOR ALL DOORS TO PREVENT DAMAGE TO DOORS OR HARDWARE FROM STRIKING ADJACENT WALLS OR FIXTURES. 4. FURNISH RUBBER DOOR SILENCERS EQUAL TO IVES 20 FOR ALL NEW INTERIOR HOLLOW METAL FRAMES, (2) PER PAIR AND (3) PER SINGLE DOOR FRAME. 5. THRESHOLDS: ALUMINUM WITH NEOPRENE BULB TO PROVIDE AN AIR BARRIER SEAL. THRESHOLD TO BE ACCESSIBLE PER FBC CHAPTER 11 REQUIREMENT, U.O.N 6. ALL HARDWARE ACCESSORIES AND DEVICES TO MATCH BUILDING AND /OR TENANT STANDARD IN THE PARTICULAR DOOR TYPE, INCLUSIVE BUT NOT LIMITED TO DOOR SILENCERS, DOOR STOPS, HINGES, CLOSURES, LOCKING ETC. 7. CONTRACTOR TO COORDINATE ALL KEYING WITH OWNER. 8. CONTRACTOR TO VERIFY THAT ALL NEW AND EXISTING HARDWARE IS ADA COMPLIANT. 9. GENERAL CONTRACTOR TO SUBMIT TO ARCHITECT A FULLY DETAILED HARDWARE SCHEDULE WITH CUT SHEETS OF ALL ITEMS TO BE PROVIDED. THE SCHEDULE SHALL BE WRITTEN BY A HARDWARE DETAILING SPECIALIST AND SHALL BE COORDINATED WITH ALL RELATED ASPECTS OF THE PROJECT. FINISH OF ALL EXPOSED ITEMS SHALL BE OFFICE STANDARD. DEFINITIONS 1. "FURNISH" MEANS TO SUPPLY AND DELIVER TO THE PROJECT SITE, READY FOR UNLOADING, UNPACKING, ASSEMBLY, INSTALLATION AND SIMILAR OPERATIONS. 2. "INSTALL" DESCRIBES OPERATIONS AT THE PROJECT SITE INCLUDING THE ACTUAL UNLOADING, UNPACKING, ASSEMBLING, ERECTING, PLACING, ANCHORING, APPLYING, WORKING TO DIMENSION, FINISHING, CURING, PROTECTING, CLEANING AND SIMILAR OPERATIONS. 3. "PROVIDE" MEANS TO FURNISH AND INSTALL, COMPLETE AND READY FOR THE INTENDED USE. i 4. "SHOP DRAWINGS" AS DEFINED BY AIA DOCUMENT A201, SECTION 3.12.1: SHOP DRAWINGS ARE DRAWINGS, DIAGRAMS, SCHEDULES AND OTHER DATA SPECIALLY PREPARED FOR THE WORK BY THE CONTRACTOR OR A SUBCONTRACTOR, SUB- SUBCONTRACOR, MANUFACTURER, SUPPLIER OR DISTRIBUTOR TO ILLUSTRATE SOME PORTION OF THE WORK. 5. UNLESS THE CONTRACT DOCUMENTS INCLUDE MORE STRINGENT REQUIREMENTS, APPLICABLE INDUSTRY STANDARDS HAVE THE SAME FORCE AND EFFECT AS IF BOUND OR COPIED DIRECTLY INTO THE CONTRACT DOCUMENTS TO THE EXTENT REFERENCED. SUCH STANDARDS ARE MAD A PART OF THE CONTRACT DOCUMENTS BY REFERENCE. 6. PERMITS, LICENSES AND CERTIFICATES: FOR THE OWNER'S RECORDS, SUBMIT COPIES OF PERMITS, LICENSES, CERTIFICATIONS, INSPECTION REPORTS, RELEASES, JURISDICTIONAL SETTLEMENTS, NOTICES, RECEIPTS FOR FEE PAYMENTS, JUDGMENTS, CORRESPONDENCE, RECORDS AND SIMILAR DOCUMENTS, ESTABLISHED FOR COMPLIANCE WITH STANDARDS AND REGULATIONS BEARING ON PERFORMANCE OF THE WORK. 3ITY OF SUu i N N11AM` BUILDING DEPT- STRUC TURAL SECTIOPt • 1nslgni d e s i g n -%q,3z`N --I '. , - - ti•�J M� W Ln 4-J O +_j c: M M U o N � [0 � ._ U Lf) L_ 0 L- Q) LL U E > c- +-� o O p L D Ul O C/') Qj O = zr�4 4--J V) Mro W -- -- -- -- -- --- - - - - -- - -- REVISIONS SHEET TITLE: GENERAL NOTES PROJECT NO: 1110 -11 DRAWN BY: LC DATE: 05.12.2014 SCALE: AS NOTED SHEET NO: G -2