14-1075-002
ALL CIRCUITS, 2 WIRES 0.133A 0.153A 75 d 75�cd 16 17 18 --0--0- 11 12 2 6 7 0.908 AMPS (UTILIZED) NAC CKT. 1 2.5 AMPS AVAILABLE) � U U oEr. CKT 1 13 14 15 1 -O-OO OO DIET. CKT 2 8 9 10 MANUAL RELEASE 5 M RELEASE GEMINI II CONTROL PANEL t 2 3 ALL CONDUIT TO BE Yz EMT. MINIMUM MAXIMUM OF 40 DETECTORS ALLOWED PER CIRCUIT TROUBLE (TO BLDG. FRCP) ALARM (TO BLDG. FACP) TO AC 120 VAC I I (* TIED TO BUILDING ALARM) 1 L3#12GATHHNHOT,NEUTRAL, (DEDICATED) GROUND 20A BREAKER No. 2 GEMINI II PANEL RISER DIAGRAM NOT TO SCALE Through - penetration Firestop Systems System No. C -AJ -1409 November 28, 2007 F Rating - 2 Hr T Ratings - 0, % and X Hr (See Item 2) 1. Floor or Wall Assembly -Alin 4 -1/2 in. thick reinforced lightweight or normal weight (100 - 150 pcf) concrete. Floor may also be constructed of any min 6 in. thick hollow -core Precast Concrete Units*. Wall may also be constructed of any UL Classified Concrete Blocks *. Max diam of opening is 11 -1/4 in. In hollow -core floors, max diam of opening is 7 in. See Concrete Blocks (CAZi) or Precast Concrete Units (CFTV) categories in the Fire Resistance Directory for names of manufacturers. 2. Through Penetrant - One metallic pipe, tubing or conduit installed concentrically or eccentrically within the firestop system. M annular space of min 0 in. (point contact) to a max 2 -3/4 in. is required between the penetrant and the periphery of the opening. Pipe, tubing or conduit to be rigidly supported on each side of the foor assembly. The following types and sizes of metallic pipes, tubing or conduit may be used: A Steel Pipe - Nom 8 in. diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Copper Pipe - Nom 4 in. diam (or smaller) Regular (or heavier) copper pipe. C. Copper Tubing - Nom 4 in. diam (or smaller) Type L (or heavier) copper tubing. D. Conduit - Nom 6 in. diam (or smaller) steel conduit or nom 4 in. diam (or smaller) steel electrical metallic tubing. T Rating is X hr when annular space is 1 -7/8 in. or less and min in. thickness of sealant and min 4 in. thickness of mineral wool is used. T Rating is 34 hr when annular space is 1 -7/8 in. or less, and min }( in. thickness of sealant and min 2 in. thickness of mineral wool is used. The T Rating is 0 hr for annular spaces greater than 1 -7/8 in. 3. Firestop System - The firestop system shall consist of the following: A Packing Material - Nom 2 in. or 4 in. thickness of min 4 pcf mineral wool bott insulation firmly packed into opening as a permanent form. (See Item 2 above) Packing material to be recessed from top surface of floor or from both surfaces of wall or from both surfaces of hollow -core floor as required to accommodate the required thickness of fill material. B. Fill, Void or Cavity Material* - Caulk - Min 9 in. or % in. thickness of fill material applied within the annulus, flush with top surface of floor or with both surfaces of hollow -core floor. (See Item 2 above) RECTORSEAL - MC 150+ *Bearing the UL Classification Mark SEPARATE INCOMING AND OUTGOING CONDUCTORS METHOD OF TERMINATION N,A,C, VOLTAGE DROP CALCULATIONS DC RESISTANCE FOR SOLID COPPER WIRES AT 75 DEGREES -C SIZE OHMS PER FOOT 18 0.00777 16 0.00489 14 0.00307 12 0.00193 10 0.00121 VALUES TAKEN FROM 2002 NEC CHAPTER 9 TABLE 8 FORMULA FOR CALCULATION OF VOLTAGE DROP IN DC 2 WIRE CIRCUITS VD= Rx2LxI WHERE VD = VOLTAGE DROP AT THE LAST DEVICE ON THE CIRCUIT "R" = RESISTANCE OF WIRE IN OHMS PER FOOT ( VALUES OF RESISTANCE FOR COPPER WIRE PER TABLE ABOVE) "I" = TOTAL CIRCUIT CURRENT IN AMPERES " L" = LENGTH ONE WAY OF THE CIRCUIT IN FEET NAC #1 WIRE SIZE 16 R= 0.00489 L= 80 I= 0.908 VD= 0.7104 VOLTAGE AT LAST DEVICE 19.6896 X OF VOLTAGE DROP 3.48% ACCEPTABLE V - DROP YES STARTING VOLTAGE USED IN CALCULATIONS IS 20.4 PER U.L. & NFPA REQUIREMENTS Through - penetration Firestop Systems System No. W -L -1325 December 03, 2003 F Ratings - 1 and 2 Hr (See Item 1) T Rating - 0 Hr 401i111X= BATTERY CALCULATION- F-SPC FSPC STANDBY QTY. TOTAL ALARM CURRENT CURRENT .120 1 .1 .280 QTY. 1 TOTAL .280 SMOKE DETECTOR ION. .000070 5 .00035 .000100 5 .0005 SMOKE DETECTOR PHOTO. .000070 5 .00035 .000100 5 .0005 18 GA FPL SOLID DETECTORS BROWN /BLUE © 16 GA TFN SOLID MANUAL RELEASE BELL .183 1 .183 HORN ST. 75CD .153 1 .153 STROBE 75CD .133 1 .133 TOTAL STANBY =.3207 TOTAL ALARM =.99 STANDBY: 24HRS ALARM: 5 MIN. X 1/60 = .0833 HOURS REQUIRED TOTAL STANDBY STANDBY 24 X .3207 REQUIRED REQUIRED TOTAL STANDBY AMP/HRS ALARM TIME ALARM 7.696 .0833 X .99 REQUIRED ALARM CAP. .0824 REQUIRED REQUIRED STANDBY ALARM AMP /HRS. CAP. 7.696 + .0824 TOTAL OPTIONAL REQUIRED REQUIRED SAFETY BATTERY CAP. FACTOR CAP. 7.7784 X 1.2 9.334 BATTERY SIZE: 12.0 AMP HRS COLOR CODE SCHEDULE WIRE GAUGE /TYPE COLOR QA 14 GA THHN SOLID NAC RED /BLACK © 18� GA FPL SOLID DETECTORS RED /BLACK © 2 18 GA FPL SOLID DETECTORS BROWN /BLUE © 16 GA TFN SOLID MANUAL RELEASE RED /RED 0 14 GA FPL SOLID RELEASE RED /BLUE OE 16 GA TFN SOLID ABORT YELLOW /BLACK 1. Wall Assembly - The 1 or 2 hr fire rated gypsum board /stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A Studs - Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. lumber spaced 16 in. OC. Steel channel studs to be min 3 -1/2 in. wide and spaced max 24 in. OC. B. Gypsum Board* - One or two layers of nom 5/8 in. thick gypsum board as specified in the individual Wag and Partition Design. Max diom of opening is 14-1/2 in. The hourly F Rating of the firestop system is equal to the hourly fire rating of the wag assembly. 2. Metallic Sleeve - (Optional) - Cylindrical sleeve fabricated from min No. 26 gouge gdv sheet steel and having a min 1 in. overlap along the longitudinal seam. Ends of sleeve to be flush with or extend a max 1 in. beyond each surface of wall. 3. Through Penetrants - One metallic pipe, conduit or tubing to be installed concentrically or eccentrically within the firestop system. Pipe, conduit or tubing to be rigidly supported on both sides of wag assembly. The following types and sizes of metallic pipes, conduit or tubing may be used: A Steel Pipe - Nom 12 in. diam (or smaller) Schedule 10 (or heavier) steel pipe. M annular space of 0 in. (point contact) to 1 -3/4 in. is required within the firestop system. B. Iron Pipe - Nom 12 in. diam (or smaller) Schedule 10 (or heavier) cast iron pipe. M annular space of 0 in. (point contact) to 1 -3/4 in. is required within the firestop system. C. Copper Tubing - Nom 4 in diom (or smaller) Type L (or heavier) copper tube. M annular space of 0 in. (point contact) to 1 -7/8 in. is required within the firestop system. D. Copper Pipe - Nom 4 in. diam (or smaller) Regular (or heavier) copper pipe. M annular space of 0 in. (point contact) to 1 -7/8 in. is required within the firestop system. E. Conduit - Nom 6 in. (or smaller) steel conduit or or nom 4 in. diam (or smaller) steel electrical metdra conduit. M annular space of 0 in. (point contact) to 1 -7/8 in. is required within the firestop system. 4. Firestop System - The firestop system shall consist of the following: A Packing Matedol - In 2 hr wall assemblies, foam backer rod firmly packed into opening as a permanent form. Packing material to be recessed from each surface of the wall to accommodate the required thickness of fill material. B. Fill Void or Cavity Materials* - Caulk - Min 1/2 in. thickness of fill material applied within the annulus on both surfaces of the wag assembly. When steel sleeve is not used or when steel sleeve is flush with the wall surfaces, a min 1/2 in. diam bead of caulk shall be applied to the penetrant /gypsum board interface at the point contact location on both sides of wall. When steel sleeve is used, a bead of caulk is applied to the steel sleeve /gypsum board interface on both sides of wall. RECTORSEAL - MC 150+ Caulk, Metacaulk 1000 I *Bearing the UL Classification Mark CADDY BAR CEILI� CEILING DETECTOR MOUNTING DETAIL N.T.S. CEILING 5cor� or WORK SCOPE OF WORK CONSIST OF REPIPING AN EXISTING FM =200 SYSTEM AND ADDING A CYLINDER. WE WILL INSTALL 1 PULL STATION, 1 ABORT, 10 SMOKE DETECTORS, 1 HORN STROBE, 1 STROBE LIGHT AND 1 MOTOR BELL. WE WILL INTERCONNECT THIS SYSTEM TO THE MAIN BUILDING FIRE ALARM PANEL. N0f5; 1. THESE UNITS OR DEVICES SHALL BE INSTALLED USING APPROVED MATERIALS AND WIRING PRACTICES IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE # 70 AND THE NATIONAL FIRE PROTECTION ASSOCIATION ARTICLE # 760 POWER LIMITED SECTION AND ALL APPLICABLE LOCAL WIRING ORDINANCES. 2. CONDUCTORS AND CABLES FOR USE WITH THIS POWER LIMITED FIRE ALARM SYSTEM SHALL BE INSTALLED IN ACCORDANCE TO THE NATIONAL FIRE PROTECTION ASSOCIATION ARTICLE # 760 POWER LIMITED SECTION AND SHALL BE LISTED FOR THIS USE. CONDUCTORS SHALL HAVE A MINIMUM RATING OF 300 VOLTS. 3. INITIATING CIRCUITS ARE CLASS'B' 4. NAC CIRCUITS ARE STYLE'Y' 5. THIS IS A POWER LIMITED SYSTEM. 6. ALL HORN /STROBES, MOUNTED AT 80" A.F.F. 7. ALL PULL STATION, ABORT SWITCH, MOUNTED AT 48" A.F.F. 8. ALL SMOKE DETECTORS MOUNTED MORE THAN T AWAY FROM A/C DIFFUSERS. 9. ALL CONDUIT TO BE 1/2" EMT, MINIMUM 10. CONDUIT FILL: 40% OR LESS 11. ALL EQUIPMENT TO BE U.L. LISTED AND COMPATIBLE 12. PENETRATIONS AS NOTED ON DETAIL 13. THIS IS A LOCAL FIRE ALARM SYSTEM. 14. FLEXIBLE CONDUIT SHALL BE USED TO CONNECT ALL DEVICES THAT ARE NOT MOUNTED ON THE WALLS, INCLUDING SOLENOIDS, LOW PRESSURE SWITCHES, ETC. 15. WIRE ABOVE CEILING TO BE EXPOSED FPL POWER LIMITED FIRE ALARM CABLE. 16. ROOM IS SERVED BY SELF CONTAINED LEIBERT UNIT. NO DAMPER OR EQUIPMENT SHUTDOWN. PROVIDING CONTACT FOR SHUTDOWN OF SELF CONTAINED LIEBERT UNIT ONLY. 17. SPACES ABOVE CEILING AND BELOW RAISED FLOOR ARE NOT USED TO RECIRCULATE AIR FROM OR TO OTHER PARTS OF THE BUILDING. 18. BATTERY CALCULATION @ 24 HRS STANDBY AND 5 MIN IN ALARM. 19. FIRE ALARM CONTRACTOR AND INSTALLATION ARE UL CERITIFIED NEE 000 �- " -2" MIN SMOKE DETECTOR A/C DIFUSER ANL , .... FLOURECENT LIGHT SMOKE DETECTOR MOUNTING DETAIL STROBE OR i 0 N*T*So 80" A.F.F. OR HORN / STROBE R 6" BELOW CEILING - 0 (WHICHEVER IS LOWER) RAISED FLOOR ADA HEIGHT REQUIREMENT APP; CI /PD By -` SPK J . Pti :tti�i s YVAT1lf� C`t`� -StTE ENGINEERS NAME MICHAEL 'C. GUERRERO DISCIPLINE MECHANICAL ENGINEER TELEPHONE (305) 262 -3944 Llc. FL 15235 # . ADDRESS 8230 CORAL WAY MIAMI, FL 33155 ENGINE 'S DA ED.,SEAL STEEL ANGLE VERTICAL \ II- -47.11 MOUNT 1111 • EMT TRUE FLOOR SUBFLOOR DETECTOR MOUNTING DETAIL N.T.S. FILE NAME: SMH Data Center - 2nd Floor Main Building Triangle Fire, Inc. l 7720 N.W. 53rd Street, Miami, FL 33166 (305) 592 -3011, Fax: (305) 592 -5254 SMH Data Center - 2nd Floor Main Building 7400 SW 62nd Avenue South Miami, Florida 33145 SCALE AS SHOWN DRAWN Orlando Alfonso DATE July 10, 2014 REVISED KIDDE FM 200 FIRE SUPRESSION SHEET SYSTEM W /ONE 350LB. AND ONE 2 40LB. AGENT TANK. of 3 SHEETS