Loading...
13-834R-019FIRST FLOOR RCP AND ELECTRICAL PLAN - ELECTCAL ol sCa� v. -.-0" GENERAL NOTES A. CONTRACTOR SHALL PROVIDE ALL EQUIPMENT AND MATERIAL NECESSARY FOR A COMPLETE AND OPERATIONAL INSTALLA110N. B. CONTRACTOR SHALL NOT DISRUPT POWER TO ELECTRICAL APPURTENANCES TO REMAIN. C. ALL EXISTING CEILING MOUNTED EQUIPMENT INCLUDING BUT NOT LIMITED TO; LIGHT FIXTURES, SPEAKERS, CAMERAS, MICROPHONES, MODULES, ETC. ARE EXISTING TO REMAIN UNLESS OTHER WISE INDICATED. CONTRACTOR SHALL EXERCISE EXTREME CAUTION DURING DUCT WORK INSTALLATION AND MAKE ANY RELOCATION, REMOVAL, AND MODIFICATIONS NECESSARY IN ORDER FOR THE CONTRACTOR TO ARCHIVE ALL DUCT WORK INSTALLATION. AT THE END OF THE PROJECT, IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO INSTALL/PLACE BACK ALL CEILING MOUNTED DEVICES TO ITS ORIGINAL LOCATION. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO REPLACE ANY DAMAGE TILES, LIGHT FIXTURES, MICROPHONES, ETC IN THE EVENT OF DAMAGE, AT NO ADDITIONAL COST TO THE OWNER. D. ALL CEILING MOUNTED DEVICES ARE SHOWN FOR REFERENCE PURPOSES ONLY. NOT ALL DEVICES HAVE BEEN SHOWN. THE CONTRACTOR SHALL VISIT THE SITE AND ASCERTAIN ALL EXISTING CONDITIONS PRIOR TO BID AND COMMENCEMENT OF WORK. E REFER TO LIFE SAFETY PLAN FOR ADDITIONAL CEILING MOUNTED DEVICES. LEGEND NOTES OCONTRACTOR SHALL REMOVE EXISTING 4, 2 LAMP CEILING MOUNTED FLUORESCENT LIGHTING AND PROVIDE NEW AS INDICATED. CONNECT NEW LIGHT FIXTURES TO EXISTING CIRCUIT WITH 2#I2, 1#12G IN 3/4'C. OLITHONIA DWM- 232- MVOLT- EBIOPS OLITHONIA 2G18- 332- A12125- MVOLT- 1 /3EB1OPS OEXISTING AHU TO BE DISCONNECTED AND REMOVED. REMOVE ALL CONDUIT AND WIRE BACK TO PANEL BREAKER IN PANEL SHALL REMAIN AS SPARE. OEXISTING EXHAUST FAN TO BE DISCONNECTED AND REMOVED, REMOVE ALL CONDUIT AND MIRE BACK TO PANEL BREAKER IN PANEL SHALL REMAIN AS SPARE. OCONTRACTOR SHALL RELOCATE ALL EXISTING DISCONNECT SWITCHES, AND JUNCTION BOXES IN THIS AREA TO AVOID CONFLICT WITH NEW AHU. EXTEND CONDUIT AND WIRE TO NEW LOCATION. 7O NEW LOCATION OF RELOCATED JUNCTION BOXES AND DISCONNECT SWITCHES. dALL 314" CONDUITS IN THIS AREA RUNNING FROM NORTH/SOUTH SHALL BE RELOCATED TO THE UNDERSIDE OF THE SLAB CEILING. CONTRACTOR SHALL EXTEND ALL CONDUIT AND WIRE AS NECESSARY AND REQUIRED FOR A COMPLETE AND OPERATIONAL INSTALLATION. OCONTRACTOR TO VERIFY EXACT LOCATION OF VAV BOXES PRIOR TO INSTALLATION AND ROUGH IN WORK. REFER TO MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION. 10 RECEPTACLE FOR CONDENSATE PUMP. COORDINATE EXACT LOCATION PRIOR TO INSTALLATION AND ROUGH IN WORK. FIRST FLOOR PLAN DEMO - ELECTRICAL (D O V- n N d' zw V N O L L N O 14- m ro N m Q) M J J G'i 0-) q) LL- -,D 1,D -O LQ LQ N L!-1 Lf'1 U — LD O E O - M M (6 a Lc) C7 ai ,-i N �-' L O X 1 :3 O N U) U 0- E c..i T � O U c)) cu Ln U) C � E -0 O c O E O � _ u b eC L N } X -^ C C (D Q) Q O (n 8 — v f6 —_ n > C In m U) 7 4 REVISIONS MARK: REMARKS: 2 OWNER REQUESTED CHANGES 10 109 12013 3 OWNER REQUESTED CHANGES 12/9/13 J � W =U Q(L �w z Oa „4 T. G ,' T. x0 , �'' +'�a" FIRST FLOOR RCP PLAN ELECTRICAL Job No: 412474.00 Date: File: Sheet Title: Sheet No: E2.01