13-834R-011GRAVITY INTAKE HOOD SCHEDULE __TLOCATION MARK UNIT TYPE SERVES THROAT SIZE (IN.) HOOD SIZE (IN.) CFM MAX. P.D. (IN. WG) HEIGHT (INCHES) I' MFR/MODEL _FWEIGHT LBS ( ) NOTES OUTSIDE AIR CFM ROOF 1140 1140 EXISTING TO REMAIN EF -EX - CORRIDOR /STORAGE CORRIDOR 2100 - GIH -D1A16 ROOF RTU -D1A16 12x12 31x27 1044 0.05 12 COOK/ 12X12GI 100 ALL SEE BELOW 139 - CONFERENCE CONFERENCE 734 - 15 5 0.06 119 NOTES* 1. ALUMINUM BIRDSCREEN AT HOOD PERIMETER, NOT AT THROAT. 2. ANTI - CONDENSATE COATING ON UNDERSIDE OF HOOD TOP. 3. 36" MIN HIGH ROOF CURB PROVIDED BY HOOD MANUFACTURER. BOTTOM OF OUTSIDE AIR INTAKE SHALL BE A MINIMUM OF 36" ABOVE FINISHED ROOF. 4. HOOD SHALL BE N.O.A. RATED. HOOD SHALL BE DIRECTLY FASTENED TO CURB AND BE ABLE TO WITHSTAND 186 MPH WIND LOAD VELOCITIES AS REQUIRED BY MIAMI DADE REQUIREMENTS. HOOD SHALL BE PROVIDED WITH AN N.O.A. STICKER. EXISTING AHU SCHEDULE DESIG. LOCA ON UNIT TYPE EXISTING DESIGN CFM NEW DESIGN CFM PRE FILT. FINAL FILT. MANUFACTURER/MODEL NO. NOTES: TOTAL RETURN OUTSIDE CFM CFM AIR CFM TOTAL CFM RETURN CFM OUTSIDE AIR CFM ROOF 1140 1140 EXISTING TO REMAIN EF -EX - CORRIDOR /STORAGE CORRIDOR 2100 - RTU -D1A16 ROOF PASTORAL CARE HORIZONTAL 4645 3505 1140 0 0 0 3096 N/A REMOVE EXISTING RTU TRANS EXISTING RTUI SEE BELOW 139 - CONFERENCE CONFERENCE 734 - 15 5 0.06 119 - RECEPTION NOTES: 1. REPLACE EXISTING DX PACKAGED ROOFTOP UNIT WITH A CHILLED WATER ROOFTOP UNIT. BASED ON AHU OUTSIDE AIR CALCULATIONS ASHRAE 62.1 -2004 AHU OCCUPANCY CATEGORY AREA OCCUPANT DENSITY OCCUPANTS COMBINED OA RATE AREA OA RATE OA REQUIRED OA PROVIDED CORRIDOR CORRIDOR 610 ROOF 1140 1140 EXISTING TO REMAIN EF -EX - CORRIDOR /STORAGE CORRIDOR 2100 - - - 0.06 126 - TOTAL OFFICE SPACE OFFICE 1483 - 10 5 0.06 139 - CONFERENCE CONFERENCE 734 - 15 5 0.06 119 - RECEPTION OFFICE 221 - 2 TOTAL AHU -B1A3 384 395 EXIST. EF SCHEDULE DESIG/ EXISTING DESIGN NEW DESIGN NOTES: LOCATION CFM CFM OA REQUIRED EF -1 CORRIDOR CORRIDOR 610 ROOF 1140 1140 EXISTING TO REMAIN EF -EX - OFFICE 1 OFFICE ROOF 395 395 EXISTING TO REMAIN BASED ON RTU OUTSIDE AIR CALCULATIONS ASHRAE 62.1 -2004 AHU OCCUPANCY CATEGORY AREA OCCUPANT DENSITY OCCUPANTS COMBINED OA RATE AREA OA RATE OA REQUIRED OA PROVIDED CORRIDOR CORRIDOR 610 - - - 0.06 37 - OFFICE 1 OFFICE 109 - 1 5 0.06 12 - OFFICE 2 OFFICE 111 - 1 5 0.06 12 - OFFICE 3 OFFICE 100 - 1 5 0.06 11 - RECEPTION OFFICE 221 - 2 5 0.06 23 - SANCTUARY RELIGIOUS 771 120 93 6 - 558 - STORAGE STORAGE 40 - - - 0.12 5 - STORAGE ALCOVE OFFICE 68 - 1 5 0.06 10 - WORK ROOM OFFICE 96 - 1 5 0.06 11 - 6/11 8/11 TYPE COIL HW CFM 4900 MAX. FACE YE7 MAX AIR P.D. " 500 /0.50 TOTAL RTU -D1A16 679 1140 CAV BOX W/ ELECTRIC REHEAT COIL SCHEDULE CHW AIR HANDLING UNIT SCHEDULE SUPPLY REHEAT COIL MANUFACTURER/MODEL NOTES INLET SIZE (IN) CFM RANGE COOLING MAX. S.P.D. IN. W.G. (NOTE -4) MAX. N.C. EAT. DB F I LAT. DB F MIN. MBH MAX. I KW VOLTAGE/ PHASE STAGES PASTORAL CARE MEDICAL RECORDS /OFFICES ► 3205 395 -395 CFM (DESIGN /FUTURE) 4900 3600 ADJ. 4 -WAY ESP / TSP ( "WG) 2.0/4.0 6" 75 -400 0.10 27 52 80 NOTE NOTE 277/1 1 SEE SPECIFICATIONS . ALL 8" 145 -800 0.12 31 52 80 NOTE NOTE 277/1 1 SEE SPECIFICATIONS ALL 10" 235 -1200 0.12 32 52 $0 NOTE NOTE 277/1 1 SEE SPECIFICATIONS ALL NU I tJ: U 1. REFER TO PLANS FOR COIL OPERATING KW. 2. REFER TO PLANS FOR ACTUAL COOLING CFM 3. MAX. N.C. RELATES TO DISCHARGE AT 1.0" INLET S.P. 4. NOT INCUDING COIL S.P.D. 5. MAX. N.C. INCUDING COIL 6. PROVIDE 24V CONTROL TRANSFORMER AS REQUIRED WHERE ELECTRIC /ELECTRONIC CONTROL IS SPECIFIED. iEEl AC V X KW* -MIN CFM AHU SERVING BOX BOX DESIGNATION *NOTE: 0 KW SIGNIFIES NO HEAT COIL A. ESP EQUALS SP LOSSES OF DUCTS ONLY. ISP EQUALS AHU SP LOSS WITH DIRTY FILTERS. TSP EQUALS ESP + ISP. B. FAN MOTOR NAMEPLATE HORSEPOWER SHALL NOT BE EXCEEDED AT SCHEDULED CFM AND TSP. C. IF ANY MANUFACTURER'S COOLING COIL PROMOTES MOISTURE CARRYOVER AT THE ALLOWABLE MAXIMUM FA.CE VELOCITY THEY SHALL OVERSIZE COOLING COIL FACE AREA TO PREVENT MOISTURE CARRYOVER AT THESE CONDITIONS. D. COILS: NO COATINGS E. COOLING COIL SENSIBLE HEAT RATIO TOLERANCE EQUALS PLUS OR MINUS 0.03. EXAMPLE: CSHR = 0.79 MINIMUM 0.76 MAXIMUM 0.82 FOR RTU PROVIDE VAPORTIGHT INCANDESCENT LIGHT- FIXTURE IN1 EACH ACCESSIBLE SECTION. PROVIDE 3 -WAY SWITCH WITH PILOT' LIGHT ON EACH SIDE OF AHU TO ENERGIZE ALL LIGHTS. FACTORY, WIRE ALL FIXTURES AND SWITCHES TO EXTERIOR JUNCTION BOX CONNECTION. REF ELECTRICAL DRAWINGS FOR 120V CIRCUIT. NOTES (AHU SCHEDULE): L 1. RTU -D1 A16 - HORIZONTAL DRAW -THRU. AHU -B1A3 - VERTICAL DRAW -THRU. )2. DOUBLE WALL CONSTRUCTION; R -13 FOAM INSULATION. �3. INTERNALLY ISOLATED FAN, DRIVE, AND MOTOR. 4. RTU SECTIONS AHU SECTIONS > PRE FILTER/ MIXING BOX SECTION PRE FILTER / MIXING BOX SECTION W CTION CTION I H 0 �"mc'-�65 UV LIGHTS /2\ CONTROLS SECTION 5. PROVIDE WITH SINGLE POINT ELECTRICAL CONNECTION PR VID 110 FA TOR M N IEN MI AL ' FOR 120V CIRCUIT. ROOF TOP UNIT SHALL BE FURNISHED YWTH FACTORY MOUNTED VFD WITH 'REDUNDANT VFD DRIVE AND AUTOMATIC CHANGEOVER. VFD SHALL BE PROVIDED WITH INTEGRAL OVERCURRENT PROTECTION DEVICE. MOTORS FOR USE WITH A 'VFD SHALL VOL BE INVERTER DUTY do HIGH EFFICIENCY RATED. VFD SHALL BE PRE -WRED AND FACTORY TESTED. VFD SHALL BE PROVIDED WAM FUSED DISCONNECT SWITCH. 8. HOUSING SHALL BE PAINTED TO COMPLY WITH 1,000 HOUR SALT CHAMBER TEST PER ASTM. 2 9. ROOF TOP UNIT MUST BE DIRECTLY FASTENED TO THE CURB T EET 190 MPH HIGH VELOCITY IWND LOAD. STRUCTURAL MOUNTING DETAIL CURB) TO BE SUBMITTED FOR APPROVAL FROM THE STRUCTURAL ENGINEER CONTRACTED BY CURB MANUFACTURER. ROOF TOP UNIT SHALL BE N.O.A. CERTIFIED. PROVIDE N.O.A. STICKER ON UNIT. 110. PROVIDE DOUBLE WALLANSULATED RTU CURB ADAPTER TO MATE WITH E)aSTING CURB. ADAPTER SHALL BE DESIGNED AND RATED TO MEET FBC NNND LOAD REQUIREMENTS. 11. NO OUTSIDE AIR HOOD REQUIRED. 12. PROVIDE OUTDOOR RATED UNIT MOUNTED MAGNEHEUC FILTER GAUGE FOR EACH FILTER BANK, INTERLOCKED TO THE BMS, 13. UNIT SHALL SHUT DOWN UPON FIRE ALARM. 14. ACCEPTABLE MANUFACTURERS INCLUDE TRANE, JOHNSON CONTROLS, TEMTROL 15. PROVIDE FLOAT SWITCH IN DRAIN PAN OR CONDENSATE DRAIN PIPING WIRED TO SHUT DOWN EQUIPMENT UPON DETECTION OF CONDENSATE BACK -UP. 16. PROVIDE WITH MANGEHEUC FILTER GAUGE IN FILTER BANK. 2 1 PROVIDE WITH VFD AND REDUNDANT VFD MATH AUTOMATIC CHANGEOVER. 18. PROVIDE WITH LITTLE GIANT VCL -24ULS CONDENSATE PUMP. 19. PROVIDE UNIT MIXING BOX VWTH INTERNAL OPOSED BLADE DAMPERS FOR RETURN AND OUTSIDE AIR CONNECTIONS. 20. PROVIDE UNIT WITH AIRFLOW MONITORING STATION ON OUTSIDE AIR. J\ J\ A w w w w w w w w� - - - 2 AIR BALANCE CALCULATIONS CHW AIR HANDLING UNIT SCHEDULE SUPPLY RETURN OUTSIDE EXHAUST TRANSFER RTU -D1 A16 AHU -B1 A3 RTU -D1 A16 4900 3760 1140 -1140 0 SERVES PASTORAL CARE MEDICAL RECORDS /OFFICES ► 3205 395 -395 CFM (DESIGN /FUTURE) 4900 3600 ADJ. 4 -WAY ESP / TSP ( "WG) 2.0/4.0 3.0/5.0 zQ FAN MOTOR HP (MAX) 2 05.5 ea 203.5 JPOWER SUPPLY (VOLTS/PHASE) 460/3 460/3 24 "x24" FAN WHEEL DIAMETER (INCHES) 16 14 N ' FAN WHEEL TYPE AF, CLASS 2 AF, CLASS 2 NO DRIVE DIRECT DIRECT CEILING RETURN GRILLE OO FAN RPM 2432 3310 - TYPE COIL CHW CHW E1 CFM (DESIGN/FUTURE) 4900 3600 O MAX. FACE VEL gF­PM) MAX, AIR-L " 500/1.0 500/1.0 12x12 TOTAL / SENS / (MBH) (MIN) 157.6/102.2 210.7/101.8 ° J EAT F DB/WB 76.7/66.8 75.0/69.0 YES LAT 'F DB/WB 57.2/56.2 48.6/48.6 RETURN GRILLE O 4 5 EWT 'F/I-WT 'F 45/55.7 45/55 oGPM (MAXIMUM) 29.3 41.4 � WATER PD (FT.) (MAX) 2.9 10.5 MIN. ROWS/MAX. FINS PER INCH 6/11 8/11 TYPE COIL HW CFM 4900 MAX. FACE YE7 MAX AIR P.D. " 500 /0.50 TOTAL CAPACITY 135.0 a ° EAT 'F DB/WB 64.0 v LAT F DB/WB 89.2 EWT F/LWT F 160/134.2 z GPM (MAXIMUM) 10.7 w = WATER PD (FT.) (MAX) 0.56 MIN. ROWS/MAX. FINS PER FOOT 2/6 OUTSIDE AIR CFM 1140 395 TYPE MERV 8 MERV 8 o EFFICIENCY (X) ( ASHRAE 52) 30 30 MAX. VELOCITY (FPM) 500 500 IZ P.D. (CLEAN/DIRTY) (INCHES W.G.) 0.18/1.00 0.18/1.00 MCA a ° MOCP - - SUPPLY FAN FLA 12.6 8.0 w V/PH/HZ 460/3/60 460/3/60 DIMENSIONS - LENGTH X WIDTH X HEIGHT (INCHES) l60x7Ox47.06 76.5x57x78 MANUFACTURER/MODEL NO. TEMTROL TEMTROL WEIGHT (LBS.) (INCLUDING PLENUMS) 4380 - NOTES 1 -15 1- 5,13 -20 A. ESP EQUALS SP LOSSES OF DUCTS ONLY. ISP EQUALS AHU SP LOSS WITH DIRTY FILTERS. TSP EQUALS ESP + ISP. B. FAN MOTOR NAMEPLATE HORSEPOWER SHALL NOT BE EXCEEDED AT SCHEDULED CFM AND TSP. C. IF ANY MANUFACTURER'S COOLING COIL PROMOTES MOISTURE CARRYOVER AT THE ALLOWABLE MAXIMUM FA.CE VELOCITY THEY SHALL OVERSIZE COOLING COIL FACE AREA TO PREVENT MOISTURE CARRYOVER AT THESE CONDITIONS. D. COILS: NO COATINGS E. COOLING COIL SENSIBLE HEAT RATIO TOLERANCE EQUALS PLUS OR MINUS 0.03. EXAMPLE: CSHR = 0.79 MINIMUM 0.76 MAXIMUM 0.82 FOR RTU PROVIDE VAPORTIGHT INCANDESCENT LIGHT- FIXTURE IN1 EACH ACCESSIBLE SECTION. PROVIDE 3 -WAY SWITCH WITH PILOT' LIGHT ON EACH SIDE OF AHU TO ENERGIZE ALL LIGHTS. FACTORY, WIRE ALL FIXTURES AND SWITCHES TO EXTERIOR JUNCTION BOX CONNECTION. REF ELECTRICAL DRAWINGS FOR 120V CIRCUIT. NOTES (AHU SCHEDULE): L 1. RTU -D1 A16 - HORIZONTAL DRAW -THRU. AHU -B1A3 - VERTICAL DRAW -THRU. )2. DOUBLE WALL CONSTRUCTION; R -13 FOAM INSULATION. �3. INTERNALLY ISOLATED FAN, DRIVE, AND MOTOR. 4. RTU SECTIONS AHU SECTIONS > PRE FILTER/ MIXING BOX SECTION PRE FILTER / MIXING BOX SECTION W CTION CTION I H 0 �"mc'-�65 UV LIGHTS /2\ CONTROLS SECTION 5. PROVIDE WITH SINGLE POINT ELECTRICAL CONNECTION PR VID 110 FA TOR M N IEN MI AL ' FOR 120V CIRCUIT. ROOF TOP UNIT SHALL BE FURNISHED YWTH FACTORY MOUNTED VFD WITH 'REDUNDANT VFD DRIVE AND AUTOMATIC CHANGEOVER. VFD SHALL BE PROVIDED WITH INTEGRAL OVERCURRENT PROTECTION DEVICE. MOTORS FOR USE WITH A 'VFD SHALL VOL BE INVERTER DUTY do HIGH EFFICIENCY RATED. VFD SHALL BE PRE -WRED AND FACTORY TESTED. VFD SHALL BE PROVIDED WAM FUSED DISCONNECT SWITCH. 8. HOUSING SHALL BE PAINTED TO COMPLY WITH 1,000 HOUR SALT CHAMBER TEST PER ASTM. 2 9. ROOF TOP UNIT MUST BE DIRECTLY FASTENED TO THE CURB T EET 190 MPH HIGH VELOCITY IWND LOAD. STRUCTURAL MOUNTING DETAIL CURB) TO BE SUBMITTED FOR APPROVAL FROM THE STRUCTURAL ENGINEER CONTRACTED BY CURB MANUFACTURER. ROOF TOP UNIT SHALL BE N.O.A. CERTIFIED. PROVIDE N.O.A. STICKER ON UNIT. 110. PROVIDE DOUBLE WALLANSULATED RTU CURB ADAPTER TO MATE WITH E)aSTING CURB. ADAPTER SHALL BE DESIGNED AND RATED TO MEET FBC NNND LOAD REQUIREMENTS. 11. NO OUTSIDE AIR HOOD REQUIRED. 12. PROVIDE OUTDOOR RATED UNIT MOUNTED MAGNEHEUC FILTER GAUGE FOR EACH FILTER BANK, INTERLOCKED TO THE BMS, 13. UNIT SHALL SHUT DOWN UPON FIRE ALARM. 14. ACCEPTABLE MANUFACTURERS INCLUDE TRANE, JOHNSON CONTROLS, TEMTROL 15. PROVIDE FLOAT SWITCH IN DRAIN PAN OR CONDENSATE DRAIN PIPING WIRED TO SHUT DOWN EQUIPMENT UPON DETECTION OF CONDENSATE BACK -UP. 16. PROVIDE WITH MANGEHEUC FILTER GAUGE IN FILTER BANK. 2 1 PROVIDE WITH VFD AND REDUNDANT VFD MATH AUTOMATIC CHANGEOVER. 18. PROVIDE WITH LITTLE GIANT VCL -24ULS CONDENSATE PUMP. 19. PROVIDE UNIT MIXING BOX VWTH INTERNAL OPOSED BLADE DAMPERS FOR RETURN AND OUTSIDE AIR CONNECTIONS. 20. PROVIDE UNIT WITH AIRFLOW MONITORING STATION ON OUTSIDE AIR. J\ J\ A w w w w w w w w� - - - 2 AIR BALANCE CALCULATIONS MARK SUPPLY RETURN OUTSIDE EXHAUST TRANSFER MAKE -UP PRESSURIZATION RTU -D1 A16 4900 3760 1140 -1140 0 0 (0) AHU -B1 A3 3600 3205 395 -395 0 0 (0) ADJ. 4 -WAY (J1 TITUS/TDC -AA CEILING SUPPLY DIFFUSER OO S3 SEE PLANS YES ADJ. AIR DEVICE SCHEDULE DESIG. SIZE OBD THROW NECK SIZE MANUFACTURER/MODEL NO. REMARKS/NOTES CFM 12 "0 325 -450 CFM 14 "0 451 -625 CFM S1 24 "X24" NO ADJ. 4 -WAY O1 TITUS/TDC -AA CEILING SUPPLY DIFFUSER OO S2 12 "X12" NO ADJ. 4 -WAY (J1 TITUS/TDC -AA CEILING SUPPLY DIFFUSER OO S3 SEE PLANS YES ADJ. FULL SIZE TITUS /300 SERIES SIDEWALL SUPPLY OO AIR GRILLE R1 24 "x24" NO - O1 TITUS /350F CEILING RETURN GRILLE OO R2 12 "x12" NO - O1 TITUS /350F CEILING RETURN GRILLE OO R3 SEE PLANS YES - FULL SIZE TITUS /350F RETURN GRILLE O3 4 5 E1 24x24 NO - O TITUS/35OF CEILING EXHAUST GRILLE OO E2 12x12 NO - �1 TITUS /35OF CEILING EXHAUST GRILLE OO E3 SEE PLANS YES - FULL SIZE T1TUS/350F RETURN GRILLE O 4 5 NO'S` (D6-0 020 -125 CFM 8 "0 126 -250 CFM 10 "0 251 -325 CFM 12 "0 325 -450 CFM 14 "0 451 -625 CFM 16 "0 626 -825 CFM 21x21 826 -1200 CFM O CONTRACTOR TO COORDINATE FRAME STYLE W/ ARCH. PLANS O CONTRACTOR TO COORDINATE FINAL FINISH WITH THE ARCHITECT. O LOUVER BARS ON GRILLE PARALLEL TO SHORT DIMENSIONS. O PROVIDE VOLUME DAMPER ADJUSTABLE THROUGH FACE OF DIFFUSER. REVISIONS MARK: REMARKS: 1 ADDENDUM 1 0701 2013 2 OWNER REQUESTED CHANGES 1049/2013 J Q Z v, qs O w = U aEL �w 1 D =a O E 6� °. .o > c :3 U o O d m M N M of a1 C O M l0 l0 to " u- ko ko c w w ui LO O c 00 o E +J c M M 0 fu j C = U_ r4 N N :L1 O X 0� ,-i 7 O s (li, '. • x N °o .:.. v o d w • N _ m • oo> #k � • L U o C f0 0 0 � REVISIONS MARK: REMARKS: 1 ADDENDUM 1 0701 2013 2 OWNER REQUESTED CHANGES 1049/2013 J Q Z v, qs O w = U aEL �w 1 D =a O MECHANICAL SCHEDULES Job No: 412474.00 Date: File: Sheet Title: Sheet No: M8,01 6� °. MECHANICAL SCHEDULES Job No: 412474.00 Date: File: Sheet Title: Sheet No: M8,01