Loading...
13-834-013U.L. APPROVED FIRE RATER MINERAL WOOL BATT, 100% FILL 1/2" 1/2- THRU 12" STEEL PIPE (SCHEDULE 10 OR HEAVIER), 1/2" THRU 6" COPPER TUBE /PIPE, 1/2" THRU 12" CAST OR DUCTILE IRON PIPE, 1/2- THRU 6" RIGID STEEL CON OR 1/2" THRU 4" EMT CO CENTERED IN SLEEVE /2" MI 2" MAX. STEEL STEEL PIPE OR STEEL SHEET SLEEVE AS REQUIRED BY WgPPROSOR IC15WB+ CAULK OR FB -3000 WT SEALANT (TYPICAL EACH SIDE OF WALL) 1 /4" DIA. BEAD 3M CP25WB+ FIRE RATED SEALANT ESCUTCHEON AT ALL PIPES EXPOSED TO VIEW SYSTEM NO. W -L -1003 1 & 2 HOUR FIRE RATING U.L. BUILDING MATERIALS 2" EQ. 2" DIRECTORY - 1999 EDITION H:�Ed i� GYPSUM WALLBOARD UNINSULATED PIPE PENETRATION THROUGH 0 6NO SCALE GYPSUM -BOARD RATED PARTITION STEEL PIPE OR STEE SHEET SLEEVE AS REQUIRED BY SPECIFICATIONS 1/2' 1/2- THRU 12" STEEL OR 1/2" THRU 6" COP PIPE/TUBE CENTERED II 3/4" 1" MA APPROVED FIRE RATED ERAL WOOL BATT, 100% FILL t" DIA. BEAD 3M CP25WB+ E RATED SEALANT CP25WB+ CAULK OR -3000 WT SEALANT SYSTEM NO. W -L -5011 1 & 2 HOUR FIRE RATING LATION (MAX. 1-1/2- U.L. CERTIFICATION THICKNESS) DIRECTORY - 2007 EDITION ��..�TCHEON AT ALL STEEL STUBS- PIPES EXPOSED TO VIEW GYPSUM WALLBOARD INSULATED PIPE PENETRATION THROUGH GYPSUM -BOARD RATED PARTITION 05NO SCALE 2" EQ. 2" SYSTEM NO. C —AJ -1044 2 HOUR FIRE RATING U.L. BUILDING MATERIALS DIRECTORY — 1999 EDITION U.L. APPROVED FIRE RATED MINERAL WOOL BATT., 100% FILL U.L. APPROVED 3M CP25WB+ WATERPROOF RESILIENT FIRE RATED SEALANT (TYPICAL EACH SIDE OF WALL) ESCUTCHEON AT ALL PIPES EXPOSED TO VIEW MIN. 4 -1/2" THICK CONCRETE OR U.L. CLASSIFIED CONCRETE BLOCK WALL UNINSULATED PIPE PENETRATION THROUGH CONCRETE WALLS ABOVE GRADE 04 NO SCALE E �o v � c j 4� o o d U o) WOOD BLOCK AT CHILLED WATER PIPING ca M N M V) C OR STEEL INSULATION PROTECTION o M w ko I SADDLE AT STEAM PIPING (1 u- lD tD •° vi U) u) C -O Q) v ui ui o c SPRING ISOLATOR o o L o p0Ln ("OOMM � E (TYPICAL) a M (� v = i �� —c N rLo O oC .-i D O t X L . NcnU a22 0) c c MAXIMUM SPACING 2' -0" C TO CC ° ' n N HANGER ROD NO INSULATION o a -r It I_- a (TYPICAL) VAPOR BARRIER o, V INSULATION N m ru v c HEAVY DUTY HOCKING VAPOR BARRIER o z CLEMS HANGER INSULATION -� E aQ SUPPORT ROLLER NUT STAND REVISIONS LOCK WASHER I f9IT MARK: REMARKS: AND DOUBLE NUTS 11 H PIPE STEEL SUPPORT PIPE 16 GA STEEL SADDLE 12" LONG INSULATION WHERE 16 GAGE ZINC COATED BOLT PIPE ROLLERS TO CHANNEL SPECIFIED SHALL BUTT SHEET STEEL SADDLE AT LOCK WASHER AGAINST PIPE HANGERS LEAST 12" LONG. AND DOUBLE NUTS CLEMS HANGER CLEMS HANGER TRAPEZE HANGER SINGLE HORIZONTAL RUNS UNO VAPOR SINGLE HORIZONTAL RUNS WITH VAPOR MULTIPLE HORIZONTAL RUNS WITH OR WITHOUT VAPOR BARRIER INSULATION BARRIER INSULATION BARRIER INSULATION V 3 PIPE SUPPORTS DETAIL NO SCALE DRAIN LINE SHALL BE AT LEAST THE SAME SIZE AS THE NIPPLE ON THE DRAIN OPEN NIPPLE ABOVE PAN. TOP OF DRAIN PAN. C.O. C.O. O EVERY CHANGE IN mia DIRECTION GREATER THAN 450 AND AT MAX. OF 25 FEET INTERVALS. PITCH DOWN TOWARD DRAIN, MIN. 1/8" PER ft. T.S.P. OF FAN PLUS 1" WATER ROOF DRAIN TO TERMINATION REFER TO PLUMBING DRAIN PAN CONDENSATE DRAIN TRAP WITH SUFFICIENT TRAP SEAL TO OFFSET PRESSURE AT DRAIN PAN. no CONDENSATE DRAIN TRAP DETAIL V G NO SCALE 00 = 0. W CO ow =U �a Q[L �w Oa U.L. APPROVED 3M FS -195'+ STEEL PIPE OR STEEL SHEET SLEEVE AS REQUIRED BY SPECIFICATIONS, CAST IN WATERPROOF RESILIENT FIRE PLACE (MIN. 3 LAYERS) RATED SEALANT (TYPICAL EACH 1/2- THRU 30" STEEL PIPE j. •'' ' ►,: :+ : :: �' • •�' (SCHEDULE 10 OR HEAVIER), °'• °' °' 1/2- THRU 6" COPPER TUBE /PIPE, '•� : �' '; '; 1/2- THRU 30" CAST OR DUCTILE IRON PIPE, 1/2- THRU 6" RIGID STEEL CONDUIT, OR 1/2" THRU 4" EMT CONDUIT CENTERED IN SLEEVE — 1/2- MIN. SHEET SLEEVE AS 1 -1 /4" MAX. 2" EQ. 2" SYSTEM NO. C —AJ -1044 2 HOUR FIRE RATING U.L. BUILDING MATERIALS DIRECTORY — 1999 EDITION U.L. APPROVED FIRE RATED MINERAL WOOL BATT., 100% FILL U.L. APPROVED 3M CP25WB+ WATERPROOF RESILIENT FIRE RATED SEALANT (TYPICAL EACH SIDE OF WALL) ESCUTCHEON AT ALL PIPES EXPOSED TO VIEW MIN. 4 -1/2" THICK CONCRETE OR U.L. CLASSIFIED CONCRETE BLOCK WALL UNINSULATED PIPE PENETRATION THROUGH CONCRETE WALLS ABOVE GRADE 04 NO SCALE E �o v � c j 4� o o d U o) WOOD BLOCK AT CHILLED WATER PIPING ca M N M V) C OR STEEL INSULATION PROTECTION o M w ko I SADDLE AT STEAM PIPING (1 u- lD tD •° vi U) u) C -O Q) v ui ui o c SPRING ISOLATOR o o L o p0Ln ("OOMM � E (TYPICAL) a M (� v = i �� —c N rLo O oC .-i D O t X L . NcnU a22 0) c c MAXIMUM SPACING 2' -0" C TO CC ° ' n N HANGER ROD NO INSULATION o a -r It I_- a (TYPICAL) VAPOR BARRIER o, V INSULATION N m ru v c HEAVY DUTY HOCKING VAPOR BARRIER o z CLEMS HANGER INSULATION -� E aQ SUPPORT ROLLER NUT STAND REVISIONS LOCK WASHER I f9IT MARK: REMARKS: AND DOUBLE NUTS 11 H PIPE STEEL SUPPORT PIPE 16 GA STEEL SADDLE 12" LONG INSULATION WHERE 16 GAGE ZINC COATED BOLT PIPE ROLLERS TO CHANNEL SPECIFIED SHALL BUTT SHEET STEEL SADDLE AT LOCK WASHER AGAINST PIPE HANGERS LEAST 12" LONG. AND DOUBLE NUTS CLEMS HANGER CLEMS HANGER TRAPEZE HANGER SINGLE HORIZONTAL RUNS UNO VAPOR SINGLE HORIZONTAL RUNS WITH VAPOR MULTIPLE HORIZONTAL RUNS WITH OR WITHOUT VAPOR BARRIER INSULATION BARRIER INSULATION BARRIER INSULATION V 3 PIPE SUPPORTS DETAIL NO SCALE DRAIN LINE SHALL BE AT LEAST THE SAME SIZE AS THE NIPPLE ON THE DRAIN OPEN NIPPLE ABOVE PAN. TOP OF DRAIN PAN. C.O. C.O. O EVERY CHANGE IN mia DIRECTION GREATER THAN 450 AND AT MAX. OF 25 FEET INTERVALS. PITCH DOWN TOWARD DRAIN, MIN. 1/8" PER ft. T.S.P. OF FAN PLUS 1" WATER ROOF DRAIN TO TERMINATION REFER TO PLUMBING DRAIN PAN CONDENSATE DRAIN TRAP WITH SUFFICIENT TRAP SEAL TO OFFSET PRESSURE AT DRAIN PAN. no CONDENSATE DRAIN TRAP DETAIL V G NO SCALE 00 = 0. W CO ow =U �a Q[L �w Oa U.L. APPROVED 3M FS -195'+ U.L. APPROVED 3M CP25WB+ FIRE RATED WRAP /STRIP, 100% FILL WATERPROOF RESILIENT FIRE (MIN. 3 LAYERS) RATED SEALANT (TYPICAL EACH . ;,;. ;• % , •�.,• SIDE OF WALL) INSULATION (MAX. 3 -1/2" %'' %• %• "•�''• WALL THICKNESS) STEEL PIPE OR STEEL SHEET SLEEVE AS • REQUIRED BY JINNI 1/2" THRU 30" STEEL PIPE .�:::'� : : "' :� :; :' SPECIFICATIONS, CAST IN °� (SCHEDULE 10 OR HEAVIER), ;•; ; ; PLACE 1/2" THRU 15" CAST IRON •..; •; ' '• ESCUTCHEON AT ALL ;. °`° ��I�IfiA, L, PIPE, PIPES EXPOSED TO VIEW P?p °�F OR 1/2 THRU 4 COPPER �� PIPE CENTERED IN SLEEVE 3/4" MIN. 1" MAX.' " mECiINIICAI EQ. (1" MI .. •. EQ. (1" MIN.) ,. :.: °, :.,: :.: �e��IrdII919W��a� ' • �' • •'.• '•: MIN. 4 -1/2" THICK CONCRETE MECHANICAL %: • � OR U.L. CLASSIFIED CONCRETE ''' '' BLOCK WALL DETAILS SYSTEM NO. C -AJ -5002 2 HOUR FIRE RATING U.L. BUILDING MATERIALS DIRECTORY - 1999 EDITION INSULATED PPE PENETRATION THROUGH niCONCRETE WALLS ABOVE GRADE V I NO SCALE INTERIOR MODIFICATIONS ONLY (ANY tIffERIOR MODIFICATION IWAVREQUIRE A BOARD APPEARANCE) Job No: 412474.00 Date: File: Sheet Title: Sheet No: M7.01