13-834-004FAF�TIAL FLCCF,) FLAN = AfREA 11,411
SCALE: 1/4" = 11 -0"
0
3
A-2
I I
OFFICE .
1 1
1 1
1 1
1
1 1
STORAGE 1
FNa 11
MEDICAL STAFF
OFFICE
9
WORK
AREA
AUNICATIO
ROOM )
`i
EXTERIOR SERVICE YARD
CONFERENCE
' ROOM
1
FAF�TIAL f=L0CfP-, FLAN � Afii�F?4 11511
SCALE: 1/4" = P -0"
APPLY EPDXY BONDING ADHESIVE
(*CONCRE5IVE LIQUID LPL' BY MASTER
BUILDERS, OR EQUAL) ON CLEAN DRY
SURFACE FREE OF GREASE AND OIL
CONTAMINANTS) TO A MINIMUM THICKNESS OF
15 MILS, PRIOR TO PLACING FRESH
CONCRETE. FOLLOW EPDXY MANUFACTURER'S
SURFACE PREPARATION, MIXING AND
APPLICATION RECOMMENDATIONS.
- 1/2'L (SEE
%I I .fx
EXISTING 5" THICK I I —I
CONCRETE SLAB ON
WELL COMPACTED FILL
NEW 4" THICK CONCRETE
PAD - USE 4000 PSI
POLYPROPYLENE FIBER
REINFORCED LOW SLUMP
(3') CONCRETE. PROVIDE A
LAYER OF 6X(o-W2XW2 W.W.M.
I" FROM TOP.
1 ) CONCRETE PAD DETAIL
EXISTING METAL -
STUDS to 16' O.G.
(TYPICAL)
NEW SOUND ATTENUATION
BLANKET BETWEEN STUDS
TO MATCH EXISTING.
*NEW 5/5" GYP.
WALLBOARD WITH
SPAKLING TAPE AND
JOINT COMPUND -
5ANDWET JOINTS TO
PREPARE FOR PAINTING
(TYP.)
EXISTING 5/5"
GYPSUM
WALLBOARD W/.
SOUND
ATTENUATION
BLANKET.
(TYP.J
PLAN VIEW
*NOTE. USE 5/5" GYPSUM WALLBOARD TYPE "X" ON 1
HR. FIRE RATED PARTITIONS.
3 ) PARTITION - PATCH DETAIL
C0N5Tfi;;,'UCTI0N NOTE5
OPATCH / REPAIR EXISTING CONCRETE
MASONRY OPENING W/. CONCRETE MASONRY
BLOCK - STUCCO FINISH ACCORDINGLY TO
MATCH EXISTING. SEE DETAIL "2" ON THIS
SHEET.
OEXISTING METAL LOUVER ABOVE
DOOR TO REMAIN - REPLACE
EXISTING BIRD SCREEN MESH W/.
SAME TYPE.
OOUTLINE OF NEW CONCRETE HOUSEKEEPING
3 PAD 4' -5" W. x 6' -8" L. x 6" H. FOR NEW AIR
HANDLER UNIT. SEE DETAIL "1" ON THIS
SHEET.
4 CONTRACTOR 5HALL PATCH /REPAIR ANY
UNPROTECTED WALL PENETRATION
ACCORDINGLY TO PRE5ERVE EXISTING
REQUIRED FIRE RATING.
OEX15TING ELECTRICAL PANEL TO REMAIN.
OEXISTING WALL MOUNTED PLYWOOD WITH
PANELS / BOXES / DEVICES, ETC. SHALL
REMAIN.
OALL EXISTING PIPING IN THIS ROOM HAS
NOT BEEN SHOWN FOR CLARITY. ALL TO
REMAIN AS - 15, NO CHANGES ARE
REQUIRED AS PART OF THIS PROJECT.
ONO ARCHITECTURAL WORK 15 REQUIRED IN
THI5 SPACE / ROOM EXCEPT FOR THE
REMOVAL OF THE EXISTING SUSPENDED
ACOUSTICAL CEILING AND REPLACEMENT
W/_ NEW. SEE FIRST FLOOR PARTIAL
REFLECTED CEILING PLAN ON SHEET A -3,
FOR SCOPE OF WORK.
ONFIX /PATCH FLOORING AS REQUIRED
WHERE REMOVED A/C METAL STAND
STOOD. NEW FINISHES SHALL MATCH
EXISTING.
I--
0
z
NEW 111 5 'a 8" LONG DOWEL
AT 16" O.C. SET IN CONCRETE
FILLED CELL- 4" MINIMUM
EMBEDMENT (TYP.)
f ' FILLED CELL WITH
I �v CONCRETE (TYP.)
• � ❑ 4
EXISTING MASONRY Of 'G.
EXISTING SMOOTH (VARIES)
STUCCO FINISH L NEW STUCCO - EXISTING ,5" CONC.
FINISH SHALL MASONRY BLOCK
MATCH EXISTING
EXTERIOR
PLAN VIEW
N.T.S l 2) BLOCK -UP /PATCH MASONRY OPENING
N.T.5
N.T.5
0 N AV
A 0
a r c h i
t e c t s
FLORIDA LICENSE GAA0002689
2100 Ponce de Leon Blvd Suite
1170, Cral Gables, Florida 33134
TtL I305)2aS7177
Fu, (30x)261.8435
LIRS E. NAY& ALA n AR0008063
SgJ 5
FLOOR PLAN 1__.EGE1�1�
ONE HOUR D
�■� �� ��
WALL OR PARTITION
ro
(SEE PARTITION TYPES)
ONE HC'JR F'5-,1E /SMOKE RATED
� V
WALL O*K tARTITION
(SEE F,4RTIT;CN T' _P3_S)
TWO HOUR FIRE %SMOKE RATED
WALL OR PARTITION
�
(SEE PARTITION TYPES)
O
U rn
NEW REINFORCED CONCRETE
COLUMN OR CONCRETE WALL
05EIEASCH. 4 STRUCTURAL PLANS)
r-
NEW CONCRETE BLOCK WALL
M , 0 (0
(SEE FLOOR PLANS)
NEW METAL STUD PARTITION
(SEE FLOOR PLANS AND
(PARTITION TYPE DETAILS)
-�
0) 0)
EXISTING REINFORCED CONC_
■
COLUMN OR CONCRETE WALL
(SEE FLOOR PLANS)
viLn Ln
EXISTING WALL OR
PARTITION TO REMAIN
Uo.nao
WALL OR PARTITION
� o
WITH NEW DOOR AND DOOR NUMBER
M M
(COORDINATE W/ DOOR SCHEDULE)
NOTE:
I1 %
BROKEN LINE DOOR INDICATE
DOUBLE ACTING DOOR
WALL OR PARTITION WITH
EX15TING DOOR TO REMAIN
X234
ROOM NUMBER SYMBOL
(REFER TO ROOM FINISH SCHEDULE
>
CABINET SYMBOL
A
(SEE INTERIOR ELEVATIONS
ON SHEET A -II )
vaia.)
PARTITION TYPES SYMBOL
8
(REFER TO PARTITION TYPE DTLS-
AND NOTES ON SHEET A -5 )
a, -r-
W a
INTERIOR ELEVATION SYMBOL
<2>
(SEE INTERIOR ELEVATIONS
ON SHEET A -6, A --1, AND A -10 )
ro
ELEVATION MARKS
(HATCHING DENOTES NEW)
(UNHATCHED DENOTES EXISTING)
1
SECTION SYMBOL
A
W/ DRAWING AND SHEET NUMBERS
DETAIL SYMBOL
A-
W/ DRAWING AND SHEET NUMBERS
REVISION SYMBOL
3
(REFER TO COVER SHEET
FOR REVISION INFORMATION)
a Q
OUT OF SCOPE OF WORK
NOTES:
1. NOT ALL SYMBOLS ARE APPLICABLE.
s�
!�Jcqj q Pv?iAPjj)
S Y IRli _. I I.7Ri= s
v
a)
REVISIONS
MARK: REMARKS:
Q
�z
TEL rn W
VJ
OW
=U
C�
C J
Q
W
2
rOrv^ Q
J
Job No:
412474.00
Date: 06101113
File:
Sheet Title: FLOOR PLAN,
LEGEND, DETAILS 4 NOTES.
Sheet No:
A-2
2OF3
E
ro
�
� V
�
• D
4J c
�
O
U rn
0
m
r-
0
M , 0 (0
C (ten
-�
0) 0)
Y�
t0 tO
viLn Ln
c o
Uo.nao
� o
0 In
M M
E
•
O
N U)
U (5. V
X
>
d1
c c
vaia.)
C 0 r-
a, -r-
W a
m in
„.~
ro
f
0 0 •�
• L
,v
c U)
o ro
-F�
a Q
REVISIONS
MARK: REMARKS:
Q
�z
TEL rn W
VJ
OW
=U
C�
C J
Q
W
2
rOrv^ Q
J
Job No:
412474.00
Date: 06101113
File:
Sheet Title: FLOOR PLAN,
LEGEND, DETAILS 4 NOTES.
Sheet No:
A-2